Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical wavefront”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures

Alignment of two-element telescopes is a classic problem. During recent integration and test of the Space Interferometry Mission s (SIM s) Astrometric Beam Combiner (ABC), the innovators were faced with aligning two such telescope subsystems in the presence of a further complication: only two small subapertures in each telescope s pupil were accessible for measuring the wavefront with a Fizeau interferometer. This meant that the familiar aberrations that might be interpreted to infer system misalignments could be viewed only over small sub-regions of the pupil, making them hard to recognize. Further, there was no contiguous surface of the pupil connecting these two subapertures, so relative phase piston information was lost; the underlying full-aperture aberrations therefore had an additional degree of ambiguity. The solution presented here is to recognize that, in the absence of phase piston, the Zygo measurements primarily provide phase tilt in the subaperture windows of interest. Because these windows are small and situated far from the center of the (inaccessible) unobscured full aperture, any aberrations that are higher-order than tilt will be extremely high-order on the full aperture, and so not necessary or helpful to the alignment. Knowledge of the telescope s optical prescription allows straightforward evaluation of sensitivities (subap mode strength per unit full-aperture aberration), and these can be used in a predictive matrix approach to move with assurance to an aligned state. The technique is novel in every operational way compared to the standard approach of alignment based on full-aperture aberrations or searching for best rms wavefront. This approach is closely grounded in the observable quantities most appropriate to the problem. It is also more intuitive than inverting full phase maps (or subaperture Zernike spectra) with a ray-tracing program, which must certainly work in principle, but in practice met with limited success. Even if such classical alignment techniques became practical, the techniques reported here form a reassuringly transparent and intuitive check on the course of the alignment with very little computational effort.

Bloemhof, Eric E.↗

Conceptual Design of the Adaptive Optics System for the Laser Communication Relay Demonstration Ground Station at Table Mountain

The Laser Communication Relay Demonstration will feature a geostationary satellite communicating via optical links to multiple ground stations. The first ground station (GS-1) is the 1m OCTL telescope at Table Mountain in California. The optical link will utilize pulse position modulation (PPM) and differential phase shift keying (DPSK) protocols. The DPSK link necessitates that adaptive optics (AO) be used to relay the incoming beam into the single mode fiber that is the input of the modem. The GS-1 AO system will have two MEMS Deformable mirrors to achieve the needed actuator density and stroke limit. The AO system will sense the aberrations with a Shack-Hartmann wavefront sensor using the light from the communication link's 1.55 microns laser to close the loop. The system will operate day and night. The system's software will be based on heritage software from the Palm 3000 AO system, reducing risk and cost. The AO system is being designed to work at r(sub 0) greater than 3.3 cm (measured at 500 nm and zenith) and at elevations greater than 20deg above the horizon. In our worst case operating conditions we expect to achieve Strehl ratios of over 70% (at 1.55 microns), which should couple 57% of the light into the single mode DPSK fiber. This paper describes the conceptual design of the AO system, predicted performance and discusses some of the trades that were conducted during the design process.

optical communications↗

Modeling of Optical Aberration Correction using a Liquid Crystal Device

Gruneisen (sup 1-3), has shown that small, light weight, liquid crystal based devices can correct for the optical distortion caused by an imperfect primary mirror in a telescope and has discussed the efficiency of this correction. In this paper we expand on that work and propose a semi-analytical approach for quantifying the efficiency of a liquid crystal based wavefront corrector for this application.

Xinghua, Wang↗

Characterizing Deformable Mirrors for the MagAO-X Instrument

The MagAO-X instrument is a new extreme adaptive optics system for high-contrast imaging at visibleand near-infrared wavelengths on the Magellan Clay Telescope. A central component of this system is a 2040-actuatormicroelectromechanical deformable mirror (DM) from Boston Micromachines Corp. that operates at 3.63 kHz forhigh-order wavefront control (the tweeter). Two additional DMs from ALPAO perform the low-order (the woofer)and non-common-path science-arm wavefront correction (the NCPC DM). Prior to integration with the instrument, wecharacterized these devices using a Zygo Verifire Interferometer to measure each DM surface. We present the resultsof the characterization effort here, demonstrating the ability to drive tweeter to a flat of 6.9 nm RMS surface (and 0.56nm RMS surface within its control bandwidth), the woofer to 2.2 nm root mean square (RMS) surface, and the NCPCDM to 2.1 nm RMS surface over the MagAO-X beam footprint on each device. Using focus-diversity phase retrievalon the MagAO-X science cameras to estimate the internal instrument wavefront error (WFE), we further show that theintegrated DMs correct the instrument WFE to 18.7 nm RMS, which, combined with a 11.7% pupil amplitude RMS,produces a Strehl ratio of 0.94 at H↵

Kyle Van Gorkom↗

Flight Phasemeter on the Laser Ranging Interferometer on the GRACE Follow-On Mission

As the first inter-spacecraft laser interferometer, the Laser Ranging Interferometer (LRI) on the GRACE Follow-On Mission will demonstrate interferometry technology relevant to the LISA mission. This paper focuses on the completed LRI Laser Ranging Processor (LRP), which includes heterodyne signal phase tracking at µcycle/vHz precision, differential wavefront sensing, offset frequency phase locking and Pound-Drever-Hall laser stabilization. The LRI design has characteristics that are similar to those for LISA: 1064nm NPRO laser source, science bandwidth in the mHz range, MHz-range intermediate frequency and Doppler shift, detected optical power of tens of picoWatts. Laser frequency stabilization has been demonstrated at a level below 30 Hz/vHz, better than the LISA requirement of 300 Hz/vHz. The LRP has completed all performance testing and environmental qualification and has been delivered to the GRACE Follow-On spacecraft. The LRI is poised to test the LISA techniques of tone-assisted time delay interferometry and arm-locking. GRACE Follow-On launches in 2017.

Bachman, B↗

Bessel spatial profile of a soft x-ray laser beam

We report far-field profile measurements of an optical-field-ionized high-order harmonic-seeded soft x-ray laser. We show that the beam transverse profile can be controlled between a regular Gaussian shape and a Bessel profile exhibiting several rings via the infrared laser pump intensity. These experimental data are supported by a complete numerical modeling including a two-dimensional plasma amplifier simulation and a two-level soft x-ray amplification using a Maxwell-Bloch treatment. This model takes into account the experimental high-order harmonic wavefront and intensity before it is numerically amplified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Property Requirements for Glasses, Ceramics and Plastics in Spacecraft Window Systems

This is a preliminary draft of a standard published by the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) that is intended to provide uniform window optical design requirements in support of the development of human-rated spaceflight hardware. The material covered in this standard is based on data from extensive testing by the Advanced Sensing and Optical Measurement Branch at NASA Langley Research Center, and compiled into requirements format by the NASA JSC Structural Engineering Division. At the time of this initial document release, a broader technical community has not reviewed this standard. The technical content of this standard is primarily based on the Constellation Program Orion Crew Exploration Vehicle Window Optical Properties Requirements, CxP 72407, Baseline. Unlike other optical requirements documents available for human rated spacecraft, this document includes requirements that ensure functionality for windows that contain glass/ceramic and/or plastic window substrate materials. These requirements were derived by measuring the optical properties of fused silica and aluminosilicate glass window assemblies and ensuring that the performance of any window assembly that includes a plastic pane or panes will meet the performance level of the all-glass assemblies. The resulting requirements are based upon the performance and parameter metrology testing of a variety of materials, including glass, transparent ceramics, acrylics, and polycarbonates. In general, these requirements are minimum specifications for each optical parameter in order to achieve the function specified for each functional category, A through D. Because acrylic materials perform at a higher level than polycarbonates in the optics regime, and CxP/Orion is planning to use acrylic in the Orion spacecraft, these requirements are based heavily on metrology from that material. As a result, two of the current Category D requirements for plastics are cited in such a way that will result in the screening out of polycarbonates. It is acknowledged that many polycarbonates can perform the functions of Category D, such as piloting and imagery with lens with apertures up to 25mm, without performance issues. Therefore, this forward warns users that certain requirements, such as birefringence and wavefront, for Category D plastics need to be revised to allow those polycarbonates that perform adequately in Category D to be accepted, while at the same time, screen out those materials that do not perform up to par. At the time of document release, the requirements in question have been identified by a TBD beside the proposed requirement criteria (which is based upon acrylic performance). Vehicles that are designed with acrylic materials for windowpanes are encouraged to use the values presented in this document for all requirements, in order to ensure adequate optical performance.

Lynda R Estes↗

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of multilayer-reflected beam profiles and their coherence properties using beamlines ID19 (ESRF) and 32-ID (APS)

The use of multilayer mirrors is an interesting alternative for reflective X-ray monochromatization with respect to reflection from crystal optics. The increased photon flux density due to the multilayers' larger bandwidth is of crucial importance for, e.g, full-field X-ray imaging applications. Drawbacks are the introduced modifications of the reflected beam profile as well as a certain loss of coherence, summarized as wavefront degradation. Our recent work has shown that the modification of the beam profile can vary with, e.g., the material composition of the coating applied. In order to verify our findings, a beamline round-robin has been initiated, comparing the wavefront profiles after reflection by selected multilayers at beamlines 32-ID (Advanced Photon Source) and ID19 (European Synchrotron Radiation Facility) with our initial results acquired at BM05 (ESRF) [1].

43 PARTICLE ACCELERATORS↗

RISE: robust iterative surface extension for sub-nanometer X-ray mirror fabrication

Precision optics have been widely required in many advanced technological applications. X-ray mirrors, as an example, serve as the key optical components at synchrotron radiation and free electron laser facilities. They are rectangular silicon or glass substrates where a rectangular Clear Aperture (CA) needs to be polished to sub-nanometer Root Mean Squared (RMS) to keep the imaging capability of the incoming X-ray wavefront at the diffraction limit. The convolutional polishing model requires a CA to be extended with extra data, from which the dwell time is calculated via deconvolution. However, since deconvolution is very sensitive to boundary errors and noise, the existing surface extension methods can hardly fulfill the sub-nanometer requirement. On one hand, the figure errors in a CA were improperly modeled during the extension, leading to continuity issues along the boundary. On the other hand, uncorrectable high-frequency errors and noise were also extended. In this study, we propose a novel Robust Iterative Surface Extension (RISE) method that resolves these problems with a data fitting strategy. RISE models the figure errors in a CA with orthogonal polynomials and ensures that only correctable errors are fit and extended. Combined with boundary conditions, an iterative refinement of dwell time is then proposed to compensate the errors brought by the extension and deconvolution, which drastically reduces the estimated figure error residuals in a CA while the increase of total dwell time is negligible. To our best knowledge, RISE is the first data fitting-based surface extension method and is the first to optimize dwell time based on iterative extension. An experimental verification of RISE is given by fabricating two elliptic cylinders (10 mm × 80 mm CAs) starting from a sphere with a radius of curvature around 173 m using ion beam figuring. The figure errors in the two CAs greatly improved from 204.96 nm RMS and 190.28 nm RMS to 0.62 nm RMS and 0.71 nm RMS, respectively, which proves that RISE is an effective method for sub-nanometer level X-ray mirror fabrication.

36 MATERIALS SCIENCE↗

Integrated adaptive optics optical coherence tomography and adaptive optics scanning laser ophthalmoscope system for simultaneous cellular resolution in vivo retinal imaging

We describe an ultrahigh-resolution (UHR) retinal imaging system that combines adaptive optics Fourier-domain optical coherence tomography (AO-OCT) with an adaptive optics scanning laser ophthalmoscope (AO-SLO) to allow simultaneous data acquisition by the two modalities. The AO-SLO subsystem was integrated into the previously described AO-UHR OCT instrument with minimal changes to the latter. This was done in order to ensure optimal performance and image quality of the AO- UHR OCT. In this design both imaging modalities share most of the optical components including a common AO-subsystem and vertical scanner. One of the benefits of combining Fd-OCT with SLO includes automatic co-registration between two acquisition channels for direct comparison between retinal structures imaged by both modalities (e.g., photoreceptor mosaics or microvasculature maps). Because of differences in the detection scheme of the two systems, this dual imaging modality instrument can provide insight into retinal morphology and potentially function, that could not be accessed easily by a single system. In this paper we describe details of the components and parameters of the combined instrument, including incorporation of a novel membrane magnetic deformable mirror with increased stroke and actuator count used as a single wavefront corrector. We also discuss laser safety calculations for this multimodal system. Finally, retinal images acquired in vivo with this system are presented.

59 BASIC BIOLOGICAL SCIENCES↗

Optimizing a cleaning process for multilayer-dielectric- (MLD) diffraction gratings

An essential component for the OMEGA EP short-pulse petawatt laser system is the grating compressor chamber (GCC). This large (12,375 ft 3 ) vacuum chamber contains critical optics where laser-pulse compression is performed at the output of the system on two 40-cm-sq-aperture, IR (1054-nm) laser beams. Critical to this compression, within the GCC, are four sets of tiled multilayer-dielectric- (MLD) diffraction gratings that provide the capability for producing 2.6-kJ output IR energy per beam at 10 ps. The primary requirements for these large-aperture (43-cm × 47-cm) gratings are diffraction efficiencies greater than 95%, peak-to-valley wavefront quality of less than λ/10 waves, and laser-induced-damage thresholds greater than 2.7 J/cm 2 at 10-ps measured beam normal. Degradation of the grating laser-damage threshold due to adsorption of contaminants from the manufacturing process must be prevented to maintain system performance. In this paper we discuss an optimized cleaning process to achieve the OMEGA EP requirements. The fabrication of MLD gratings involves processes that utilize a wide variety of both organic materials (photoresist processes) and inorganic materials (metals and metal oxides) that can affect the final cleaning process. Finally, a number of these materials have significant optical absorbance; therefore, incomplete cleaning of these residues may result in the MLD gratings experiencing laser damage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Matlab based Toolkits used to Interface with Optical Design Software for NASA's James Webb Space Telescope

The viewgraph presentation provides an introduction to the James Webb Space Telescope (JWST). The first part provides a brief overview of Matlab toolkits including CodeV, OSLO, and Zemax Toolkits. The toolkit overview examines purpose, layout, how Matlab gets data from CodeV, function layout, and using cvHELP. The second part provides examples of use with JWST, including wavefront sensitivities and alignment simulations.

Howard, Joseph↗

Wavefront Controls for a Large Submillimeter-Wave Observatory

The 25-m aperture Cornell Caltech Atacama Telescope (CCAT) will have a primary mirror that is divided into 162 individual segments, each of which is equipped with 3 positioning actuators. This paper presents a mathematical description of the telescope, its actuators and sensors, and uses it to derive control laws for figure maintenance. A Kalman Filter-based Optical State Estimator is used to continuously estimate the aberrations of the telescope; these are used in a state-feedback controller to maintain image quality. This approach provides the means to correct for the optical effects of errors that occur in unactuated degrees of freedom, such as lateral translations of the segments. The control laws are exercised in Monte Carlo and covariance analysis, to bound the closed-loop performance of the telescope and to conduct control design trades.

edge sensors↗

Broadband electro-optic polarization conversion with atomically thin black phosphorus

Metasurfaces tune polarization In photonic systems, the polarization state of light is typically manipulated with bulky components based on dielectrics and liquid crystals. Active metasurfaces now provide the possibility of shrinking the size of these components to the nanoscale. Biswas et al . demonstrate an active nanophotonic structure capable of versatile electro-optic polarization conversion. Using trilayer black phosphorus sandwiched between electrical gates forming a cavity, they show that the polarization state of light across telecommunication wavelengths can be electrically switched. Such control can be useful for a number of applications in communications, imaging, and beam steering where the wavefront of the propagating light can be actively manipulated. —ISO

Science & Technology - Other Topics↗

Category B Plastic Pane Testing for JSC 66320 Rev A Requirements Verifiable Through Acceptance Testing

JSC 66320, Revision A, Optical Property Requirements for Glasses, Ceramics, and Plastics in Spacecraft Window Systems, lists several quantitative requirements that spacecraft windowpanes must meet. Recently, we were asked to establish a capability at the Kennedy Space Center to perform these measurements on category B plastic panes, i.e., plastic panes that could be used on a spacecraft for long-focal-length photography and piloting. Two of the criteria, normal wavefront and 30-degree wavefront attributes, can be measured with existing equipment and processes (see NASA TM NESC-RP-14-00951, April 2016) and are not discussed in this document. However, the other six criteria-haze, wedge angle, birefringence, reflectance, transmittance, and color balance-required substantial development and are the subject of this document. In this document, we do not discuss the rationale behind the requirements, but we did engage in discussions with the authors of JSC 66320 in order to better understand the requirements and the verifications being imposed on windows and their testing. Accordingly, this document presents our best understanding of the requested requirements and verifications. We also present our methodology for performing each of the six measurements, along with applicable mathematics and a description, with photos, of the hardware used. In addition, we supply the results of a test on a low-quality in-house plastic window as an example of the system operation. Only requirements that can be met by acceptance test and analysis, as opposed to optical inspection, are considered in this document.

spaceflight windows↗

Speckle dynamics for dual-beam optical illumination of a rotating structure

An out-of-plane rotating object is illuminated with two spatially separated coherent beams, giving rise to fully developed speckles, which will translate and gradually decorrelate in the observation plane, located in the far field. The speckle pattern is a compound structure, consisting of random speckles modulated by a smaller and repetitive structure. Generally, these two components of the compound speckle structure will move as rigid structures with individual velocities determined by the characteristics of the two illuminating beams. Closed-form analytical expressions are found for the space- and time-lagged covariance of irradiance and the corresponding power spectrum for the two spatially separated illuminating beams. The present analysis is valid for propagation through an arbitrary ABCD system, though the focus for the experimental evaluation is far-field observations using an optical Fourier transform system. It is shown that the compound speckle structures move as two individual structures with the same decorrelation length. The velocity of the random speckles is a combination of angular and peripheral velocity, where the peripheral velocity is inversely proportional to the radius of the wavefront curvature of the incident beams. The velocity of the repetitive structure is a combination of angular and peripheral velocity, where the peripheral velocity is proportional to the ratio of the angle to the distance between the beams in the object plane. Experimental data demonstrate good agreement between theory and measurements for selected combinations of beam separation, angle between beams, and radius of wavefront curvature at the object.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modal focal adaptive optics for Bessel-focus two-photon fluorescence microscopy

Adaptive optics (AO) improves the spatial resolution of microscopy by correcting optical aberrations. While its application has been well established in microscopy modalities utilizing a circular pupil, its adaptation to systems with non-circular pupils, such as Bessel-focus two-photon fluorescence microscopy (2PFM) with an annular pupil, remains relatively uncharted. Herein, we present a modal focal AO (MFAO) method for Bessel-focus 2PFM. Measuring and correcting aberration using a spatial light modulator placed in conjugation with the focal plane of the microscope objective, MFAO employs Zernike annular polynomials — a first in AO implementation — to achieve performance on par with a previous zonal AO method, but with a notably simplified optical configuration. We validated the performance of MFAO in correcting artificial and sample-induced aberrations, as well as in in vivo imaging of zebrafish larvae and mouse brains. By expanding the application of modal AO to annular pupils as well as aberration measurement and correction to a wavefront modulator at the objective focal plane, MFAO represents a notable advancement in the implementation of AO in microscopy.

47 OTHER INSTRUMENTATION↗