Search NASA⌕ Search

SEARCH · Search NASA

Results for “pattern detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

A natural view of microbial biodiversity within hot spring cyanobacterial mat communities

This review summarizes a decade of research in which we have used molecular methods, in conjunction with more traditional approaches, to study hot spring cyanobacterial mats as models for understanding principles of microbial community ecology. Molecular methods reveal that the composition of these communities is grossly oversimplified by microscopic and cultivation methods. For example, none of 31 unique 16S rRNA sequences detected in the Octopus Spring mat, Yellowstone National Park, matches that of any prokaryote previously cultivated from geothermal systems; 11 are contributed by genetically diverse cyanobacteria, even though a single cyanobacterial species was suspected based on morphologic and culture analysis. By studying the basis for the incongruity between culture and molecular samplings of community composition, we are beginning to cultivate isolates whose 16S rRNA sequences are readily detected. By placing the genetic diversity detected in context with the well-defined natural environmental gradients typical of hot spring mat systems, the relationship between gene and species diversity is clarified and ecological patterns of species occurrence emerge. By combining these ecological patterns with the evolutionary patterns inherently revealed by phylogenetic analysis of gene sequence data, we find that it may be possible to understand microbial biodiversity within these systems by using principles similar to those developed by evolutionary ecologists to understand biodiversity of larger species. We hope that such an approach guides microbial ecologists to a more realistic and predictive understanding of microbial species occurrence and responsiveness in both natural and disturbed habitats.

Review↗

RXTE Observations of A1744-361: Correlated Spectral and Timing Behavior

We analyze Rossi X-ray Timing Explorer (RXTE) Proportional Counter Array (PCA) data of the transient low mass X-ray binary (LMXB) system A1744-361. We explore the X-ray intensity and spectral evolution of the source, perform timing analysis, and find that A1744-361 is a weak LMXB, that shows atoll behavior at high intensity states. The color-color diagram indicates that this LMXB was observed in a low intensity spectrally hard (low-hard) state and in a high intensity banana state. The low-hard state shows a horizontal pattern in the color-color diagram, and the previously reported dipper QPO appears only during this state. We also perform energy spectral analyses, and report the first detection of broad iron emission line and iron absorption edge from A1744-361.

Bhattacharyya, Sudip↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

DC calibration of the strain sensitivity of a single mode optical fiber interferometer

The strain sensitivity of an optical fiber interferometer developed for the detection of pulsed ultrasonic waves in solids has been calibrated. The optical paths in both signal and reference arms of the interferometer are through similar 2 m lengths of ITT-110 single mode fibers mode stripped by index matching at both ends and attached to opposite sides of a 30 cm plexiglas bar 0.3 cm thick. Light from the output ends of both fibers was superimposed to form an interference fringe pattern that was interrogated in the far field to give a signal proportional to the differential optical fiber path length. Strain sensitivity was determined by comparing data obtained by clamping and bending the bar at different lengths to simple cantilever beam theory. Calibration indicates a minimum theoretical detectable strain of less than 10 to the -10.

Claus, R. O.↗

A technique for interpretation of multispectral remote sensor data

The author has identified the following significant results. The U.S. Army Engineer Waterways Experiment Station is engaged in a study to detect from ERTS-1 satellite data alterations to the absorption and scattering properties caused by movement of suspended particles and solutes in selected areas of the Chesapeake Bay and to correlate the data to determine the feasibility of delineating flow patterns, flushing action of the estuary, and sediment and pollutant dispersion. As a part of this study, ADP techniques have been developed that permit automatic interpretation of data from any multispectral remote sensor with computer systems which have limited memory capacity and computing speed. The multispectral remote sensor is considered as a reflectance spectrophotometer. The data which define the spectral reflectance characteristics of a scene are scanned pixel by pixel. Each pixel whose spectral reflectance matches a reference spectrum is identified, and the results are shown in a map that identifies the locations where spectrum matches were detected and spectrum that was matched. The interpretation technique is described and an example of interpreted data from ERTS-1 is presented.

Williamson, A. N.↗

Cytometer on a chip

An assay technique for label-free, highly parallel, qualitative and quantitative detection of specific cell populations in a sample and for assessing cell functional status, cell-cell interactions and cellular responses to drugs, environmental toxins, bacteria, viruses and other factors that may affect cell function. The technique includes a) creating a first array of binding regions in a predetermined spatial pattern on a sensor surface capable of specifically binding the cells to be assayed; b) creating a second set of binding regions in specific spatial patterns relative to the first set designed to efficiently capture potential secreted or released products from cells captured on the first set of binding regions; c) contacting the sensor surface with the sample, and d) simultaneously monitoring the optical properties of all the binding regions of the sensor surface to determine the presence and concentration of specific cell populations in the sample and their functional status by detecting released or secreted bioproducts.

Lynes, Michael A.↗

Ion-neutral Coupling During Deep Solar Minimum

The equatorial ionosphere under conditions of deep solar minimum exhibits structuring due to tidal forces. Data from instruments carried by the Communication Navigation Outage Forecasting System (CNOFS) which was launched in April 2008 have been analyzed for the first 2 years following launch. The Planar Langmuir Probe (PLP), Ion Velocity Meter (IVM) and Vector Electric Field Investigation (VEFI) all detect periodic structures during the 20082010 period which appear to be tides. However when the tidal features detected by these instruments are compared, there are distinctive and significant differences between the observations. Tides in neutral densities measured by the Gravity Recovery and Climate Experiment (GRACE) satellite were also observed during June 2008. In addition, Broad Plasma Decreases (BPDs) appear as a deep absolute minimum in the plasma and neutral density tidal pattern. These are co-located with regions of large downward-directed ion meridional velocities and minima in the zonal drifts, all on the nightside. The region in which BPDs occur coincides with a peak in occurrence rate of dawn depletions in plasma density observed on the Defense Meterological Satellite Program (DMSP) spacecraft, as well as a minimum in radiance detected by UV imagers on the Thermosphere Ionosphere Mesosphere Energetics and Dynamics (TIMED) and IMAGE satellites

IVM↗

Aerosol pattern correlation techniques of wind measurement

This paper reviews the current status of lidar image correlation techniques of remote wind measurement. It also examines the potential use of satellite borne lidar global wind measurements using this approach. Lidar systems can easily detect spatial variations in the volume scattering cross section of naturally occurring aerosols. Lidar derived RHI, PPI and range-time displays of aerosol backscatter have been extensively employed in the study of atmospheric structure. Descriptions of this type of data can be obtained in many references including Kunkel et al. (1977), Kunkel et al. (1980), Boers et al. (1984), Uthe et al. (1980), Melfi et al. (1985) and Browell et al. (1983). It is likely that the first space-borne lidars for atmospheric studies will observe aerosol backscatter to measure parameters such as boundary layer depth and cloud height. This paper examines the potential application of these relatively simple aerosol backscatter lidars to global wind measurements.

Eloranta, Edwin W.↗

Effects of Kapton Sample Cell Windows on the Detection Limit of Smectite: Implications for CheMin on the Mars Science Laboratory Mission

The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity is an X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of providing the mineralogical and chemical compositions of rocks and soils on the surface of Mars. CheMin uses a microfocus X-ray tube with a Co target, transmission geometry, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CheMin has two different window materials used for sample cells -- Mylar and Kapton. Instrument details are provided elsewhere. Fe/Mg-smectite (e.g., nontronite) has been identified in Gale Crater, the MSL future landing site, by CRISM spectra. While large quantities of phyllosilicate minerals will be easily detected by CheMin, it is important to establish detection limits of such phases to understand capabilities and limitations of the instrument. A previous study indicated that the (001) peak of smectite at 15 Ang was detectable in a mixture of 1 wt.% smectite with olivine when Mylar is the window material for the sample cell. Complications arise when Kapton is the window material because Kapton itself also has a diffraction peak near 15 Ang (6.8 deg 2 Theta). This study presents results of mineral mixtures of smectite and olivine to determine smectite detection limits for Kapton sample cells. Because the intensity and position of the smectite (001) peak depends on the hydration state, we also analyzed mixtures with "hydrated" and "dehydrated"h smectite to examine the effects of hydration state on detection limits.

Achilles, C. N.↗

Coronary Risk Factor Scoring as a Guide for Counseling

A risk factor scoring system for early detection, possible prediction, and counseling to coronary heart disease patients is discussed. Scoring data include dynamic EKG, cholesterol levels, triglycerine content, total lipid level, total phospolipid levels, and electrophoretic patterns. Results indicate such a system is effective in identifying high risk subjects, but that the ability to predict exceeds the ability to prevent heart disease or its complications.

Robert L. Fleck↗

Toward modeling a dynamic biological neural network

The organization of a mammalian macular endorgan is interpreted on physical and engineering principles. Having accomplished this task, it is possible to mathematically and symbolically model information processing by the macular neural network. A complex symbolic model is produced through use of mathematical notations that describe the functioning system. The model, consisting of six tiers, is constructed to mimic the neural system. On the basis of initial simulations, it is concluded that the network functions best when some of the detecting elements (i.e., type I hair cells) are weakly inhibitory. The simulations also illustrate the importance of disinhibition of receptors located in the third tier in shaping nerve discharge patterns at the sixth tier in the model system.

Ross, M. D.↗

Detection of CMOS bridging faults using minimal stuck-at fault test sets

The performance of minimal stuck-at fault test sets at detecting bridging faults are evaluated. New functional models of circuit primitives are presented which allow accurate representation of bridging faults under switch-level simulation. The effectiveness of the patterns is evaluated using both voltage and current testing.

Ijaz, Nabeel↗

Abnormal Canine Bone Development Associated with Hypergravity Exposure

Chronic centrifugation of 85- to 92-day-old Beagles at 2.0 x g and 2.6 x g for 26 weeks during the time of active skeletal growth caused skeletal abnormalities in the radius and the ulna of ten of 11 dogs. The pattern of change mimicked that found in naturally occurring and experimentally induced premature distal ulnar physeal closure or delayed growth at this physis. Minimal changes in bone density were detected by sensitive photon absorptiometric techniques. Skeletal abnormalities also were found in five of the six cage-control dogs, although the run-control dogs were radiographically normal.

Morgan, J. P.↗

A Study of Direct and Cloud-Mediated Radiative Forcing of Climate Due to Aerosols

The Intergovernmental Panel on Climate Change (IPCC) has reported that in the southeastern US and eastern China, the general greenhouse warming due to anthropogenic gaseous emissions is dominated by the cooling effect of anthropogenic aerosols. To verify this model prediction in eastern China and southeastern US, we analyzed regional patterns of climate changes at 72 stations in eastern China during 1951- 94 (44 years), and at 52 stations in the southeastern US during 1949-94 (46 years) to detect the fingerprint of aerosol radiative forcing. It was found that the mean rates of change of annual mean daily, maximum, minimum temperatures and diurnal temperature range (DTR) in eastern China were 0.8, -0.2, 1.8, and -2.0 C/100 years respectively, while the mean rates of change of annual mean daily, maximum, minimum temperatures and DTR in the southeastern US were -0.2, -0.6, 0.2, and -0.8 C/100 years, respectively. This indicates that the high rate of increase in annual mean minimum temperature in eastern China results in a slightly warming trend of daily temperature, while the high rate of decrease in annual mean maximum temperature and low rate of increase in annual mean minimum temperature lead to the cooling trend of daily temperature in the southeastern US. We found that the warming from the longwave forcing due to both greenhouse gases and aerosols was completely counteracted by the shortwave aerosol forcing in the southeastern US in the past 46 years. A slightly overall warming trend in eastern China is evident; winters have become milder. This finding is explained by hypothesizing that increasing energy usage during the past 44 years has resulted in more coal and biomass burning, thus increasing the emission of absorbing soot and organic aerosols in eastern China. Such emissions, in addition to well-known Asia dust and greenhouse gases, may be responsible for the winter warming trend in eastern China that we have reported here. The sensitivity of aerosol radiative properties to aerosol composition, size distribution, relative humidity (RH) is examined for the following aerosol systems: inorganic and organic ions (Cl-, Br-, NO3 -, SO4 2-, Na+, NH4 +, K+, Ca2+, Mg2+, HCOO-, CH3COO-, CH3CH2COO-, CH3COCOO-, OOCCOO2-, MSA-1); water-insoluble inorganic and organic compounds (elemental carbon, n-alkanes, SiO2, Al2O3, Fe2O3 and other organic compounds). The partial molar refraction method was used to calculate the real part of the refractive index. It was found that the asymmetry factor increased by approximately 48% with the real part varying from 1.40 to 1.65, and the single scattering albedo decreased by 24% with the imaginary part varying from -0.005 to -0.1. The asymmetry factor increased by 5.4 times with the geometric standard deviation varying from 1.2 to 3.0. The radiation transmission is very sensitive to the change in size distribution; other factors are not as significant. To determine the aerosol direct radiative forcing (ADRF), the aerosol optical depth (AOD) values at the three operational wavelengths (415, 500 and 673 nm) were determined at a regionally representative site, namely, Mt. Gibbs (35.78 deg N, 82.29 deg W, elevation 2006 m) in Mt. Mitchell State Park, NC, and a site located in an adjacent valley (Black Mountain, 35.66 deg N, 82.38 deg W, elevation 951 m) in the southeastern US. The two sites are separated horizontally by 10 km and vertically by 1 km. It was found that the representative total AOD values at 500 nm at the valley site for highly polluted (HP), marine (M) and continental (C) air masses were 0.68 +/- 0.33, 0.29 +/- 0.19 and 0.10 +/- 0.04, respectively. A search-graph method was used to retrieve the columnar size distribution (number concentration N, effective radius reff and geometric standard deviation=?g) from the optical depth observations at three operational wavelengths. The ground albedo, single scattering albedo and imaginary part of the refractive index were calculated using a mathematically unique procedure involving a Mie code and a radiative transfer code in conjunction with the retrieved aerosol size distribution, AOD, and diffuse-direct irradiance ratio. It was found that N, r(eff) and sigma(g) were in the ranges of 10 to 1.7 x 10(exp 4)/cubic cm, 0.09 to 0.68 micrometers and 1.12 to 2.95, respectively. The asymmetry factor and single scattering albedo were in the ranges of 0.63 to 0.75 and 0.74 to 0.97 respectively. The ground albedo for the forested terrain and imaginary part of refractive index were found to be in the ranges of 0.06 to 0.29 and 0.005 to 0.051 respectively. On the basis of these aerosol radiative properties obtained at the research sites and computations using the Column Radiation Model (CRM) of National Center of Atmospheric Research (NCAR) Community Climate Model (CCM3), it was found that the average cloud-free 24-hour ADRF values were -13 +/- 8, -8 +/- 3, -33 +/- 16 W/square m for marine, continental, and polluted air masses, respectively. On the assumption that the fractional coverage of clouds is 0.61, it was estimated that the annual mean ADRF was 7 +/- 2 W/square m in the southeastern US. The review with respect to the current knowledge of organic acids shows that aerosol formate and acetate concentrations range from 0.02 to 5.3 nmol/cubic m and from 0.03 to 12.4 nmol/cubic m respectively, and that between 34% to 77% of formate and between 21% to 66% of acetate are present in the fine fraction of aerosols. It was found that although most (98-99%) of these volatile organic acids were present in the gas phase, their concentrations in the aerosol particles were sufficient to make them a good candidate for cloud condensation nuclei (CCN). It is hypothesized that organic acids are at least one of the primary sources of CCN in the atmosphere due to their ubiquitous presence in the troposphere, especially over the continental forested areas. The results of our measurements at Palmer Station, Antarctica show that the daily average CCN concentrations at 0.3% and 1% supersaturations ranged from 0.3 to 160/cubic cm and from 4 to 168/cubic cm, respectively, during the period from 17 January to 26 February, 1994. New evidence for substantial and definitive CCN enhancement near and within cloud has been observed at Mt. Mitchell, North Carolina. The results show that the average monthly CCN concentrations were 460 +/- 217, 386 +/- 286, 429 +/- 228 and 238 +/- 134/cubic cm for in-cloud, overcast, clear and rainy conditions, respectively. The typical CCN spectra show that there were a lot of small CCN produced and the ion concentrations (especially H+ and SO4 2-) were very high during the CCN enhancement period. The significantly positive correlation between black carbon (BC) and CCN at 1% supersaturation indicates that a percentage of the BC measured at the site may be in the form of an internal mixture and participated in the formation of CCN.

Yu, Shao-Cai↗

M.I.T./Canadian vestibular experiments on the Spacelab-1 mission: 6. Vestibular reactions to lateral acceleration following ten days of weightlessness

Tests of otolith function were performed pre-flight and post-flight on the science crew of the first Spacelab Mission with a rail-mounted linear acceleration sled. Four tests were performed using horizontal lateral (y-axis) acceleration: perception of linear motion, a closed loop nulling task, dynamic ocular torsion, and lateral eye deviations. The motion perception test measured the time to detect the onset and direction of near threshold accelerations. Post-flight measures of threshold and velocity constant obtained during the days immediately following the mission showed no consistent pattern of change among the four crewmen compared to their pre-flight baseline other than an increased variability of response. In the closed loop nulling task, crewmen controlled the motion of the sled and attempted to null a computer-generated random disturbance motion. When performed in the light, no difference in ability was noted between pre-flight and post-flight. In the dark, however, two of the four crewmen exhibited somewhat enhanced performance post-flight. Dynamic ocular torsion was measured in response to sinusoidal lateral acceleration which produces a gravitionertial stimulus equivalent to lateral head tilt without rotational movement of the head. Results available for two crewmen suggest a decreased amplitude of sinusoidal ocular torsion when measured on the day of landing (R+0) and an increasing amplitude when measured during the week following the mission.

short duration↗

Apparatus and method using a holographic optical element for converting a spectral distribution to image points

A holographic optical element transforms a spectral distribution of light to image points. The element comprises areas, each of which acts as a separate lens to image the light incident in its area to an image point. Each area contains the recorded hologram of a point source object. The image points can be made to lie in a line in the same focal plane so as to align with a linear array detector. A version of the element has been developed that has concentric equal areas to match the circular fringe pattern of a Fabry-Perot interferometer. The element has high transmission efficiency, and when coupled with high quantum efficiency solid state detectors, provides an efficient photon-collecting detection system. The element may be used as part of the detection system in a direct detection Doppler lidar system or multiple field of view lidar system.

McGill, Matthew J.↗

Systematic Error Cancellation for a Four-Port Interferometric Polarimeter

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept to measure the gravitational-wave signature of primordial inflation through its distinctive imprint on the linear polarization of thecosmic microwave background (CMB). Its optical system couples a polarizing Fourier transform spectrometerto the sky to measure the differential signal between orthogonal linear polarization states from two co-pointedbeams on the sky. The double differential nature of the four-port measurement mitigates beam-related systematic errors common to the two-port systems used in most CMB measurements. Systematic errors coupling unpolarized temperature gradients to a false polarized signal cancel to first order for any individual detector. Thiscommon-mode cancellation is performed optically, prior to detection, and does not depend on the instrumentcalibration. Systematic errors coupling temperature to polarization cancel to second order when comparing signals from independent detectors. We describe the polarized beam patterns for PIXIE and assess the systematicerror for measurements of CMB polarization.

Kogut, Alan J.↗