Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Anisotropy of radiation emitted from planar wire arrays

The planar wire array (PWA) is a promising load for new multi-source inertial confinement fusion (ICF) hohlraums [B. Jones et al., Phys. Rev. Lett. 104, 125001 (2010)]. The hohlraum radiation symmetry is an important issue for ICF. It was found that extreme ultraviolet and sub-keV photon emission from PWAs may have considerable anisotropy in the load azimuthal plane. This experimental result is obtained on the UNR 1–1.7 MA Zebra generator. The time-dependent anisotropy effect is detected. This feature is studied in 2D numerical simulations and can be explained by initial anisotropy of implosion of those non-cylindrical loads radiating essentially as surface sources in sub-keV quanta and also by radiation absorption in cold magnetized plasma tails forming in the direction of magnetic compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laterally patterned spin-valve superlattice: Magnetometry and polarized neutron scattering study

The magnetization reversal of magnetic multilayers with spin-valve like characteristics, patterned into an array of parallel stripes, was structurally and magnetically analyzed, in detail, via x-ray scattering, magnetometry, and polarized neutron reflectivity. Each stripe contains a multiple repetition of the layer sequence [Fe/Cr/Co/Cr]. X-ray and neutron scattering maps of the patterned multilayer show rich details resulting from the superposition of Bragg peaks representing the lateral in-plane periodicity and the out-of-plane multilayer period. Detailed analysis of specular and off-specular polarized neutron intensity was used to ascertain the antiparallel alignment of the Co and Fe magnetization within the kink region of their combined hysteresis loop between the coercive fields of Fe and Co layers. This includes also an examination of domain formation and inter- as well as intra-stripe correlation effects upon magnetization reversal. Our combined study shows that the shape induced anisotropy via patterning is capable of overriding the four-fold crystal anisotropy but is unable to eliminate the ripple domain state of the Co layers, already present in the continuous multilayer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron mobility of self-assembled and dislocation free InN nanorods grown on GaN nano wall network template

A kinetically controlled two-step growth process for the formation of an array of dislocation free high mobility InN nanorods (NRs) on GaN nanowall network (NWN) by Molecular Beam Epitaxy is demonstrated here. The epitaxial GaN NWN is formed on c-sapphire under nitrogen rich conditions, and then changing the source from Ga to In at appropriate substrate temperature yields the nucleation of a self assembled spontaneous m-plane side faceted-InN NR. By HRTEM, the NRs are shown to be dislocation-free and have a low band gap value of 0.65 eV. Hall measurements are carried out on a single InN NR along with J-V measurements that yield mobility values as high as ≈4453 cm{sup 2}/V s and the carrier concentration of ≈1.1 × 10{sup 17} cm{sup −3}, which are unprecedented in the literature for comparable InN NR diameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-BRA-06: Dose Distributions for the CivaSheet Pd-103 Directional Brachytherapy Device

Purpose: A flexible polymer membrane (CivaSheet) has been developed by CivaTech Oncology, Inc. (Research Triangle Park, NC) for permanent brachytherapy. Distributed throughout the array are small plastic disks containing Pd-103 and gold foil shielding on one side to provide a directional dose distribution and facilitate imaging. This study evaluated dosimetry for the CivaSheet. Methods: Manufacturer-provided dimensional and compositional information for the device were compared to physical samples for validation of design information, then entered into the MCNP6 radiation transport code for dosimetry simulations. Three device sizes (6×6, 6×12, or 6×18 disk-arrays) were simulated as the membrane can be custom-sized preceding surgical placement. Dose to water was estimated with 0.01 cm resolution from the surface to 10 cm on both sides of the device. Because this is a novel device with calibration methods under development, results were normalized using DVHs to provide 90% prescription coverage to a plane positioned 0.5 cm from the front surfaces. This same normalization was used for creating isodose distributions. Results: Planar dose distributions of flat CivaSheets were relatively homogeneous with acceptable dose uniformity variations. Differences in the results between the differently sized CivaSheets were not significant. At 0.5 mm, 87% of the target volume was within the therapeutic dose range. Dose hotspots on the CivaSheet forward surfaces were directly above the disks. However, dose hotspots on the rear-facing surfaces were positioned between the disks. Doses in contact with the front surface were similar to those observed for currently available brachytherapy sources. Maximum doses that occurred on the rear surface were approximately 55 times lower than the dose on the front surface. Conclusion: Monte Carlo calculations validated the directional capabilities and advantageous dosimetry of the new Pd-103 brachytherapy device. It appears feasible to re-size the CivaSheet in the operating room with an acceptable variation in prescription dose. Research was supported by CivaTech Oncology, Inc.

60 APPLIED LIFE SCIENCES↗

R&D of a high-performance DIRC detector for a future electron-ion collider

An Electron-Ion Collider (EIC) is proposed as the next big scientific facility to be built in the United States, costing over $1 billion in design and construction. Each detector concept for the electron/ion beam interaction point is integrated into a large solenoidal magnet. The necessity for excellent hadronic particle identification (pion/kaon/proton) in the barrel region of the solenoid has pushed research and development (R&D) towards a new, high-performance Detection of Internally Reflected Cherenkov light (DIRC) detector design. The passage of a high energy charged particle through a fused silica bar of the DIRC generates optical Cherenkov radiation. A large fraction of this light propagates by total internal reflection to the end of the bar, where the photon trajectories expand in a large volume before reaching a highly segmented photo-detector array. The spatial and temporal distribution of the Cherenkov light at the photo-detector array allows one to reconstruct the angle of emission of the light relative to the incident charged particle track. In order to reach the desired performance of 3sigma pi/K separation at 6 GeV/c particle momentum a new 3-layer spherical lens focusing optic with a lanthanum crown glass central layer was designed to have a nearly at focal plane. In order to validate the EIC DIRC simulation package, a synergistic test beam campaign was carried out in 2015 at the CERN PS with the PANDA Barrel DIRC group using a prototype DIRC detector. Along with the analysis of the CERN test beam data, measurements of the focal plane of the 3-layer lens were performed using a custom-built laser setup at Old Dominion University. Radiation hardness of the lanthanum crown glass was tested using a 160 keV X-ray source and a monochromator at the Catholic University of America. Results of these test-bench experiments and the analysis of the 2015 CERN test beam data are presented here.

43 PARTICLE ACCELERATORS↗

The Magnetic Spectrometer PRISMA Combined With Large Gamma Arrays

The large solid angle magnetic spectrometer for heavy ions PRISMA was operated at LNL in conjunction with the highly efficient CLARA set-up up to the end of March 2008. The AGATA Demonstrator is being mounted around the target area of PRISMA replacing the CLARA set-up. It will allow to carry out nuclear structure and reaction mechanism studies with better resolution and higher statistics. New detectors for light ions and slow moving heavy ions have been designed for the focal plane of the spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unconventional Superlattice Ordering in Intercalated Transition Metal Dichalcogenide V1/3NbS2

The interplay between symmetry and topology in magnetic materials makes it possible to engineer exotic phases and technologically useful properties. A key requirement for these pursuits is achieving control over local crystallographic and magnetic structure, usually through sample morphology (such as synthesis of bulk crystals versus thin films) and application of magnetic or electric fields. Here we show that V1/3NbS2 can be crystallized in two ordered superlattices, distinguished by the periodicity of out-of-plane magnetic intercalants. Whereas one of these structures is metallic and displays the hallmarks of altermagnetism, the other superlattice, which has not been isolated before in this family of intercalation compounds, is a semimetallic noncollinear antiferromagnet that may enable access to topologically nontrivial properties. This observation of an unconventional superlattice structure establishes a powerful route for tailoring the tremendous array of magnetic and electronic behaviors hosted in related materials and may expand their use in low-power spintronic or topological quantum devices.

Fender, Shannon S↗

HELICAL MAGNETIC FIELDS IN THE NGC 1333 IRAS 4A PROTOSTELLAR OUTFLOWS

We present Submillimeter Array polarization observations of the CO J = 3–2 line toward NGC 1333 IRAS 4A. The CO Stokes I maps at an angular resolution of ∼1″ reveal two bipolar outflows from the binary sources of NGC 1333 IRAS 4A. The kinematic features of the CO emission can be modeled by wind-driven outflows at ∼20° inclined from the plane of the sky. Close to the protostars the CO polarization, at an angular resolution of ∼2.″3, has a position angle approximately parallel to the magnetic field direction inferred from the dust polarizations. The CO polarization direction appears to vary smoothly from an hourglass field around the core to an arc-like morphology wrapping around the outflow, suggesting a helical structure of magnetic fields that inherits the poloidal fields at the launching point and consists of toroidal fields at a farther distance of outflow. The helical magnetic field is consistent with the theoretical expectations for launching and collimating outflows from a magnetized rotating disk. Considering that the CO polarized emission is mainly contributed from the low-velocity and low-resolution data, the helical magnetic field is likely a product of the wind–envelope interaction in the wind-driven outflows. The CO data reveal a PA of ∼30° deflection in the outflows. The variation in the CO polarization angle seems to correlate with the deflections. We speculate that the helical magnetic field contributes to ∼10° deflection of the outflows by means of Lorentz force.

79 ASTRONOMY AND ASTROPHYSICS↗

Grazing Incident Small Angle X-ray Scattering: A Metrology to Probe Nanopatterned Surfaces

Grazing incident small angle x-ray scattering (GISAXS) and transmission small angle x-ray scattering studies have been carried out on periodic patterns on silicon substrates in order to determine the average morphology and arrangement of the patterned features. The GISAXS pattern exhibited rods of scattering at Bragg positions, discrete and evenly spaced, in the surface plane. The scattered intensity modulations along each rod have been compared with simulated scattering from simple geometrical patterns to obtain quantitative information on the diameter, width, height, and sidewall inclination of the pillars and gratings. The results are in good agreement with real space images obtained with SEM and demonstrate that GISAXS is a powerful technique for characterizing nanoscale arrays used in patterned media, photonics structures, and electronics structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

GAMMA-RAY SIGNAL FROM EARTH-MASS DARK MATTER MICROHALOS

Earth-mass dark matter microhalos with a size of {approx}100 AU are the first structures formed in the universe, if the dark matter of the universe is made of neutralinos. Here, we report the results of ultra-high-resolution simulations of the formation and evolution of these microhalos. We found that microhalos have the central density cusps of the form {rho} {proportional_to} r {sup -1.5}, much steeper than the cusps of larger dark halos. The central regions of these microhalos survive the encounters with stars except in the very inner region of the galaxy down to the radius of a few hundreds parsecs from the galactic center. The annihilation signals from the nearest microhalos are observed as gamma-ray point sources (radius less than 1'), with unusually large proper motions of {approx}0.2 deg yr{sup -1}. Their surface brightnesses are {approx}10% of that of the galactic center. Their signal-to-noise ratios might be better if they are far from the galactic plane. Luminosities of subhalos are determined only by their mass, and they are more than one order of magnitude more luminous than the estimation by Springel et al.: a boost factor can be larger than 1000. Perturbations to the millisecond pulsars by gravitational attractions of nearby Earth-mass microhalos can be detected by the observations of Parkes Pulsar Timing Array.

79 ASTRONOMY AND ASTROPHYSICS↗

Method for Increasing the Efficiency of a Biaxial Solar Tracker with Exact Solar Orientation

Modern solar follow-up systems make it possible to increase a solar cell’s efficiency and, as a result, solar energy utilization. The paper considers modern solar follow-up methods and their operational principles. Trackers are separated onto uniaxial and biaxial according to the plane which tracking occurs. Biaxial trackers are the most efficient. The operational principles of active and passive trackers are studied. A laboratory model of a biaxial solar tracker with precise solar orientation is described, based on an algorithm for calculating the voltage with current sensors. The following are given in the paper: the current–voltage characteristic obtained for different solar array positions and using trackers; the relationships between the power and measured currents and voltages. The efficiency is calculated for different solar array positions and using a tracker.

14 SOLAR ENERGY↗

DUST CONTINUUM AND POLARIZATION FROM ENVELOPE TO CORES IN STAR FORMATION: A CASE STUDY IN THE W51 NORTH REGION

We present the first high-angular resolution (up to 0.''7, {approx}5000 AU) polarization and thermal dust continuum images toward the massive star-forming region W51 North. The observations were carried out with the Submillimeter Array (SMA) in both the subcompact (SMA-SubC) and extended (SMA-Ext) configurations at a wavelength of 870 {mu}m. W51 North is resolved into four cores (SMA1 to SMA4) in the 870 {mu}m continuum image. The associated dust polarization exhibits more complex structures than seen at lower angular resolution. We analyze the inferred morphologies of the plane-of-sky magnetic field (B ) in the SMA1 to SMA4 cores and in the envelope using the SMA-Ext and SMA-SubC data. These results are compared with the B archive images obtained from the Caltech Submillimeter Observatory (CSO) and James Clerk Maxwell Telescope (JCMT). The polarization percentage is about 1% to 4%, and it is found to decrease with higher intensity in our SMA images, which is a similar trend to that previously reported in the CSO and JCMT data. A correlation between dust intensity gradient position angles ({phi}{sub {nabla}I}) and magnetic field position angles ({phi}{sub B}) is found in the CSO, JCMT, and both SMA data sets. This correlation is further analyzed quantitatively. A systematically tighter correlation between {phi}{sub {nabla}I} and {phi}{sub B} is found in the cores, whereas the correlation decreases in outside-core regions. Magnetic field-to-gravity force ratio ({Sigma}{sub B}) maps are derived using the newly developed polarization-intensity gradient method by Koch et al. We find that the force ratios tend to be small ({Sigma}{sub B} {approx}< 0.5) in the cores in all four data sets. In regions outside of the cores, the ratios increase or the field is even dominating gravity ({Sigma}{sub B} > 1). This possibly provides a physical explanation of the tightening correlation between {phi}{sub {nabla}I} and {phi}{sub B} in the cores: The more the B field lines are dragged and aligned by gravity, the tighter the correlation is. Finally, we propose a schematic scenario for the magnetic field in W51 North to interpret the four polarization observations at different physical scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonlinear development of the two-plasmon decay instability in three dimensions

Most recent experiments on the excitation of the two plasmon-decay (TPD) instability involve a three-dimensional (3D) array of overlapping laser beams. Our recent two dimensional (2D) simulations suggested that Langmuir cavitation and collapse are important nonlinear saturation mechanisms for TPD. There are important quantitative differences in the Langmuir collapse process in 2D and 3D. To address these and other issues, we have developed a 3D Zakharov code. It has been applied to study the evolution of TPD from absolute instabilities (arising from 3D laser geometries) to the nonlinear state (J. Zhang et al., Phys. Rev. Lett. (submitted)). The present paper concentrates on the nonlinear saturated state excited by the collective action of two crossed laser beams with arbitrary polarizations. Remarkable agreement between 3D and 2D simulations is found for several averaged physical quantities when the beams are polarized in their common plane. As in the previous 2D simulations, we find: (a) the collective, initially convectively unstable triad modes dominate after a sub-picosecond burst, (b) Langmuir cavitation and collapse are important nonlinearities, and (c) that the statistics of intense cavitons are characteristic of a Gaussian random process. The 3D steady-state saturated Langmuir energy level is about 30% higher than in 2D. The auto-correlation functions of the Langmuir envelope field and of the low-frequency electron density field yield the spatial shape of the strongest collapsing cavitons which are 3D ellipsoids whose orientation depends on the laser polarizations. This tilting of the caviton's strongest electric field direction away from the normal to the target surface is a major new 3D result. This tilting may deflect the hot electron flux and thereby mitigate target preheat.

Vu, H. X.↗

Self-assembled nanoparticle aggregates: Organizing disorder for high performance surface-enhanced spectroscopy

The coherent oscillations of the surface electron gas, known as surface plasmons, in metal nanostructures can give rise to the localization of intense electromagnetic fields at the metal-dielectric interface. These strong fields are exploited in surface enhanced spectroscopies, such as Surface Enhanced Raman Scattering (SERS), for the detection and characterization of molecules at very low concentration. Still, the implementation of SERS-based biosensors requires a high level of reproducibility, combined with cheap and simple fabrication methods. For this purpose, SERS substrates based on self-assembled aggregates of commercial metallic nanoparticles (Nps) can meet all the above requests. Following this line, we report on a combined micro-Raman and Atomic Force Microscopy (AFM) analysis of the SERS efficiency of micrometric silver Np aggregates (enhancement factors up to 10{sup 9}) obtained by self-assembly. Despite the intrinsic disordered nature of these Np clusters, we were able to sort out some general rules relating the specific aggregate morphology to its plasmonic response. We found strong evidences of cooperative effects among the NPs within the cluster and namely a clear dependence of the SERS-efficiency on both the cluster area (basically linear) and the number of stacked NPs layers. A cooperative action among the superimposed layers has been proved also by electromagnetic simulations performed on simplified nanostructures consisting of stacking planes of ordered Nps. Being clear the potentialities of these disordered self-assembled clusters, in terms of both easy fabrication and signal enhancement, we developed a specific nanofabrication protocol, based on electron beam lithography and molecular functionalization, that allowed for a fine control of the Np assemblies into designed shapes fixing their area and height. In particular, we fabricated 2D ordered arrays of disordered clusters choosing gold Nps owing to their high stability. AFM measurements confirmed the regularity in spacing and size (i.e. area and layer number) of the aggregates. Preliminary SERS measurements confirm the high signal enhancement and demonstrate a quite good reproducibility over large number of aggregates within 100×100 μm{sup 2} 2D super-structure. The availability of such a multisensor could allow a careful statistical analysis of the SERS response, thus leading to a reliable quantitative estimate of the presence of relevant molecular species even at ultra-low concentration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implementation of IMRT and VMAT using Delta4 phantom and portal dosimetry as dosimetry verification tools

In this study we analyzed and compared the dose distribution of different IMRT and VMAT plans with the intent to provide pre-treatment quality assurance using two different tools. Materials/Methods: We have used the electronic portal imaging device EPID after calibration to dose and correction for the background offset signal and also the Delta4 phantom after en evaluation of angular sensitivity. The Delta4 phantom has a two-dimensional array with ionization chambers. We analyzed three plans for each anatomical site calculated by Eclipse treatment planning system. The measurements were analyzed using γ-evaluation method with passing criteria 3% absolute dose and 3 mm distance to agreement (DTA). For all the plans the range of score has been from 97% to 99% for gantry fixed at 0° while for rotational planes there was a slightly decreased pass rates and above 95%. Point measurement with a ionization chamber were done in additional to see the accuracy of portal dosimetry and to evaluate the Delta4 device to various dose rates. Conclusions: Both Delt4 and Portal dosimetry shows good results between the measured and calculated doses. While Delta4 is more accurate in measurements EPID is more time efficient. We have decided to use both methods in the first steps of IMRT and VMAT implementation and later on to decide which of the tools to use depending on the complexity of plans, how much accurate we want to be and the time we have on the machine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-188: Commission of World 1st Commercial Compact PBS Proton System

Purpose: ProteusONE is the 1st commercial compact PBS proton system with an upstream scanning gantry and C230 cyclotron. We commissioned XiO and Raystation TPS simultaneously. This is a summary of beam data collection, modeling, and verification and comparison without range shiter for this unique system with both TPS. Methods: Both Raystation and XiO requires the same measurements data: (i) integral depth dose(IDDs) of single central spot measured in water tank; (ii) absolute dose calibration measured at 2cm depth of water with mono-energetic 10×10 cm2 field with spot spacing 4mm, 1MU per spot; and (iii) beam spot characteristics in air at 0cm and ± 20cm away from ISO. To verify the beam model for both TPS, same 15 cube plans were created to simulate different treatment sites, target volumes and positions. PDDs of each plan were measured using a Multi-layer Ionization Chamber(MLIC), absolute point dose verification were measured using PPC05 in water tank and patient-specific QA were measured using MatriXX PT, a 2D ion chamber array. Results: All the point dose measurements at midSOBP were within 2% for both XiO and Raystation. However, up to 5% deviations were observed in XiO’s plans at shallow depth while within 2% in Raystation plans. 100% of the ranges measured were within 1 mm with maximum deviation of 0.5 mm. 20 patient specific plan were generated and measured in 3 planes (distal, proximal and midSOBP) in Raystation. The average of gamma index is 98.7%±3% with minimum 94% Conclusions: Both TPS were successfully commissioned and can be safely deployed for clinical use for ProteusONE. Based on our clinical experience in PBS planning, user interface, function and workflow, we preferably use Raystation as our main clinical TPS. Gamma Index >95% at 3%/3 mm criteria is our institution action level for patient specific plan QAs.

60 APPLIED LIFE SCIENCES↗

Passive linear nanoscale optical and molecular electronics device synthesis from nanoparticles

Arrays of nanoparticles whose interactions can be characterized by hopping Hamiltonians can serve as excitation transmission lines. Here we show, that in addition suitable arrangements of nanoparticles can form beam splitters, phase shifters, and crossover splitters. With these elements, any discrete unitary transformation can be implemented on input modes via a network of nanoparticles in which all the components lie in the same plane. These nanoparticle networks can produce optical functionalities at a length scale much smaller than 1 {mu}m.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits

This report provides a case study of a deep energy retrofit using a site-applied exterior insulation and finish system (EIFS). Prefabricated EIFS panels are also discussed as a potential wall insulation retrofit solution. EIFSs are common in new and retrofit commercial construction. Such products typically consist of five layers installed over the top of a water resistive barrier as follows: (1) Adhesive (2) Foam insulation (3) Base coat (4) Reinforcing mesh embedded in the base coat (5) Top or finish coat. They can be applied to new or existing buildings that employ wood or masonry construction, and can utilize an insulation thickness of up to 16 in. However, such systems are rarely used in lowrise residential retrofits. Reasons for this might include a lack of demand for or knowledge of the systems in residential retrofit industry, high cost, and/or lack of suitable distribution channels serving the residential market. While the final appearance of an EIFS installation resembles stucco, it is a distinctly different system. Stucco is a generic cementitious-based material, whereas EIFSs are proprietary synthetic formulations distributed by manufacturers to a network of authorized applicators. An EIFS is composed of polymeric (organic) bonded aggregate and cement reinforced with a glass mesh. Stucco is made of inorganic cement, sand, and lime. In this project, a home was retrofitted using a site-applied 4-in.-thick EIFS. Site-specific details were developed as required for the residential retrofit application. Site work and the costs of the EIFS were documented. The case study home was modeled using version 2 of the National Renewable Energy Laboratory-developed Building Energy Optimization (BEopt) energy and cost analysis software. While a package utilizing the 4-in. EIFS is the optimal retrofit of the options analyzed in terms of annualized energy-related costs, it is higher cost than replacing the siding with midrange vinyl alone. However, compared to high-end vinyl, the EIFS package has a lower annualized energy cost. This held true for both the Islip, New York (climate zone 4) and Boston (climate zone 5) case studies. The report discusses the risks, selection criteria, interactions with other building systems, cost, performance, and other aspects of using an EIFS in a deep energy retrofit. EIFSs do not require special site safety precautions beyond general construction site precautions. Moisture design is important. Trapping moisture between two vapor/air barriers is a risk of all wall systems, including EIFS cladding applications if an interior vapor barrier exists and if there is not adequate ventilation through the drainage plane behind the insulation layer. Face-sealed approaches that rely on exposed sealants do not provide acceptable rain control or durability and are very risky. Generally, fire codes permit EIFSs for most building types and conditions.

airtightness↗