Search NASA⌕ Search

SEARCH · Search NASA

Results for “positional dependence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Enormous electron-electron scattering in the filled-cage cubic compound B a 10 T i 24 B i 39

Cubic intermetallic compound Ba 10 Ti 24 Bi 39 has a Ba 6 Bi 16 polyhedral cage with a Bi guest atom encapsulated inside. The compound can be formulated as Ba 5 Ti 12 Bi$_{19+x}$ when $x$ signifies the extra Bi atoms filling cages. It crystallizes in a complex noncentrosymmetric cubic structure in space group $P-43m$ with cell parameter $a = 12.6787(4)Å$. The guest Bi atoms distribute diffusely in the cages and seem to play a role in stabilizing the crystal structure. The magnetic susceptibility of this compound shows a weak temperature dependence with a positive slope coefficient. The charge transport properties as a function of temperature exhibit two competing components which are in charge of positive and negative magnetoresistances. Electronic band-structure calculations reveal the complex multiband hybridization of Ti/Bi orbitals near the Fermi surface, which may play a role in the enormous electron-electron scattering in this material evidenced by the large Kadowaki-Woods ratio.

36 MATERIALS SCIENCE↗

Calculation of the performance of {sup 3}He alternative detectors with MCNPX

This paper describes the techniques that are available to calculate the performance of {sup 3}He alternative detectors using MCNPX. Calculations of the performance of safeguards detectors that use {sup 3}He have been successfully carried out for many years. In the case of coincidence or multiplicity counting, specific tallies have been implemented to calculate the Singles, Doubles and Triples counting rates. The implementation of the method was done in such a way that it equates every capture in some nuclide in the detection zone with the production of an electronic pulse from the detector. This is a very good approximation for {sup 3}He detectors and BF{sub 3} detectors. However it is not appropriate for detectors such as boron-lined proportional counters, in which the fraction of capture events leading to an electronic pulse above threshold is very dependent on the geometric arrangement, in particular the thickness and composition of the boron-containing layer. This paper gives calculations of the ideal pulse height distributions to be expected from different detector types and gives values for the probability, as a function of detector energy threshold, that a neutron capture reaction will cause an electronic pulse from the detector. This is termed the electronic efficiency. This electronic detection efficiency depends very little on the energy of the captured neutron, which in most practical cases are heavily weighted towards thermal energies. It does not depend on the position of the source neutron or moderation in the sample. For cases of interest to nuclear safeguards, measurement of uranium and plutonium in specially designed detectors, the spectrum of detected neutrons is fairly constant and thus the electronic detection efficiency becomes a detector constant. The paper discusses how the electronic detection efficiency needs to be included in the calculation of Singles, Doubles and Triples, and describes proposals to improve the tallying capability of MCNPX for such cases. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the Density of Different Materials by Using the Collimated Fast Neutron Beam

It was demonstrated in the previous work that various threat materials could be detected inside the sea going cargo container by measuring the three variables, carbon and oxygen concentration and density of investigated material. Density was determined by measuring transmitted neutrons, which is not always practical in terms of setting up the instrument geometry. In order to enable more geometry flexibility, we have investigated the possibility of using the scattered neutrons in cargo material identification. For that purpose, the densities of different materials were measured depending on the position of neutron detectors and neutron generator with respect to the target position. One neutron detector was put above the target, one behind and one in front of the target, above the neutron generator. It was shown that all three positions of neutron detectors can be successfully used to measure the target density, but only if the detected neutrons are successfully discriminated from the gamma rays. Although the associated alpha particle technique/associate particle imaging (API) was used to discriminate the neutrons from the gamma rays, it is believed that the same results would be obtained by using the pulse shape discrimination method. In that way API technique can be avoided and the neutron generator which produces much higher beam intensity than 10{sup 8} n/s can be used. (authors)

36 MATERIALS SCIENCE↗

Gas-Induced Motion of a Piston in a Vibrated Liquid-Filled Housing

We present that models and experiments are developed to investigate how a small amount of gas can cause large rectified motion of a piston in a vibrated liquid-filled housing when piston drag depends on piston position so that damping is nonlinear even for viscous flow. Two bellows serve as surrogates for the upper and lower gas regions maintained by Bjerknes forces. Without the bellows, piston motion is highly damped. With the bellows, the piston, the liquid, and the two bellows move together so that almost no liquid is forced through the gaps between the piston and the housing. This Couette mode has low damping and a strong resonance: the piston and the liquid vibrate against the spring formed by the two bellows (like the pneumatic spring formed by the gas regions). Near this resonance, the piston motion becomes large, and the nonlinear damping produces a large rectified force that pushes the piston downward against its spring suspension. A recently developed model based on quasi-steady Stokes flow is applied to this system. A drift model is developed from the full model and used to determine the equilibrium piston position as a function of vibration amplitude and frequency. Corresponding experiments are performed for two different systems. In the two-spring system, the piston is suspended against gravity between upper and lower springs. Lastly, in the spring-stop system, the piston is pushed up against a stop by a lower spring. Model and experimental results agree closely for both systems and for different bellows properties.

42 ENGINEERING↗

Uniform deposition of size-selected clusters using Lissajous scanning

Size-selected clusters can be deposited on the surface using size-selected cluster ion beams. However, because of the cross-sectional intensity distribution of the ion beam, it is difficult to define the coverage of the deposited clusters. The aggregation probability of the cluster depends on coverage, whereas cluster size on the surface depends on the position, despite the size-selected clusters are deposited. It is crucial, therefore, to deposit clusters uniformly on the surface. In this study, size-selected clusters were deposited uniformly on surfaces by scanning the cluster ions in the form of Lissajous pattern. Two sets of deflector electrodes set in orthogonal directions were placed in front of the sample surface. Triangular waves were applied to the electrodes with an irrational frequency ratio to ensure that the ion trajectory filled the sample surface. The advantages of this method are simplicity and low cost of setup compared with raster scanning method. The authors further investigated CO adsorption on size-selected Pt{sub n} (n = 7, 15, 20) clusters uniformly deposited on the Al{sub 2}O{sub 3}/NiAl(110) surface and demonstrated the importance of uniform deposition.

42 ENGINEERING↗

Assessment of out-of-field absorbed dose and equivalent dose in proton fields

Purpose: In proton therapy, as in other forms of radiation therapy, scattered and secondary particles produce undesired dose outside the target volume that may increase the risk of radiation-induced secondary cancer and interact with electronic devices in the treatment room. The authors implement a Monte Carlo model of this dose deposited outside passively scattered fields and compare it to measurements, determine the out-of-field equivalent dose, and estimate the change in the dose if the same target volumes were treated with an active beam scanning technique. Methods: Measurements are done with a thimble ionization chamber and the Wellhofer MatriXX detector inside a Lucite phantom with field configurations based on the treatment of prostate cancer and medulloblastoma. The authors use a GEANT4 Monte Carlo simulation, demonstrated to agree well with measurements inside the primary field, to simulate fields delivered in the measurements. The partial contributions to the dose are separated in the simulation by particle type and origin. Results: The agreement between experiment and simulation in the out-of-field absorbed dose is within 30% at 10-20 cm from the field edge and 90% of the data agrees within 2 standard deviations. In passive scattering, the neutron contribution to the total dose dominates in the region downstream of the Bragg peak (65%-80% due to internally produced neutrons) and inside the phantom at distances more than 10-15 cm from the field edge. The equivalent doses using 10 for the neutron weighting factor at the entrance to the phantom and at 20 cm from the field edge are 2.2 and 2.6 mSv/Gy for the prostate cancer and cranial medulloblastoma fields, respectively. The equivalent dose at 15-20 cm from the field edge decreases with depth in passive scattering and increases with depth in active scanning. Therefore, active scanning has smaller out-of-field equivalent dose by factors of 30-45 in the entrance region and this factor decreases with depth. Conclusions: The dose deposited immediately downstream of the primary field, in these cases, is dominated by internally produced neutrons; therefore, scattered and scanned fields may have similar risk of second cancer in this region. The authors confirm that there is a reduction in the out-of-field dose in active scanning but the effect decreases with depth. GEANT4 is suitable for simulating the dose deposited outside the primary field. The agreement with measurements is comparable to or better than the agreement reported for other implementations of Monte Carlo models. Depending on the position, the absorbed dose outside the primary field is dominated by contributions from primary protons that may or may not have scattered in the brass collimating devices. This is noteworthy as the quality factor of the low LET protons is well known and the relative dose risk in this region can thus be assessed accurately.

61 RADIATION PROTECTION AND DOSIMETRY↗

Using dual-energy x-ray imaging to enhance automated lung tumor tracking during real-time adaptive radiotherapy

Purpose: Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can generate radiographs with reduced bone visibility, to enhance automated lung tumor tracking for real-time adaptive radiotherapy. Methods: kV images of an anthropomorphic breathing chest phantom were experimentally acquired and radiographs of actual lung cancer patients were Monte-Carlo-simulated at three imaging settings: low-energy (70 kVp, 1.5 mAs), high-energy (140 kVp, 2.5 mAs, 1 mm additional tin filtration), and clinical (120 kVp, 0.25 mAs). Regular dual-energy images were calculated by weighted logarithmic subtraction of high- and low-energy images and filter-free dual-energy images were generated from clinical and low-energy radiographs. The weighting factor to calculate the dual-energy images was determined by means of a novel objective score. The usefulness of dual-energy imaging for real-time tracking with an automated template matching algorithm was investigated. Results: Regular dual-energy imaging was able to increase tracking accuracy in left–right images of the anthropomorphic phantom as well as in 7 out of 24 investigated patient cases. Tracking accuracy remained comparable in three cases and decreased in five cases. Filter-free dual-energy imaging was only able to increase accuracy in 2 out of 24 cases. In four cases no change in accuracy was observed and tracking accuracy worsened in nine cases. In 9 out of 24 cases, it was not possible to define a tracking template due to poor soft-tissue contrast regardless of input images. The mean localization errors using clinical, regular dual-energy, and filter-free dual-energy radiographs were 3.85, 3.32, and 5.24 mm, respectively. Tracking success was dependent on tumor position, tumor size, imaging beam angle, and patient size. Conclusions: This study has highlighted the influence of patient anatomy on the success rate of real-time markerless tumor tracking using dual-energy imaging. Additionally, the importance of the spectral separation of the imaging beams used to generate the dual-energy images has been shown.

60 APPLIED LIFE SCIENCES↗

SU-F-I-37: How Fat Distribution and Table Height Affect Estimates of Patient Size in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and hence CTDIvol and SSDE. Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). This study sought to determine if patient size estimates made from localizer scans is affected by variations in fat distribution, specifically when the widest part of the patient is not at the geometric center of the patient. Methods: Lipid gel bolus material was wrapped around an anthropomorphic phantom to simulate two different body mass distributions. The first represented a patient with fairly rigid fat and had a generally oval shape. The second was bell-shaped, representing corpulent patients more susceptible to gravity’s lustful tug. Each phantom configuration was imaged using an AP localizer and then a PA localizer. This was repeated at various scanner table heights. The width of the phantom was measured from the localizer and diagnostic images using in-house software. Results: 1) The projected phantom width varied up to 39% as table height changed.2) At some table heights, the width of the phantom, designed to represent larger patients, exceeded the localizer field of view, resulting in an underestimation of the phantom width.3) The oval-shaped phantom approached a normalized phantom width of 1 at a table height several centimeters lower (AP localizer) or higher (PA localizer) than did the bell-shaped phantom. Conclusion: Accurate estimation of patient size from localizer scans is dependent on patient positioning with respect to scanner isocenter and is limited in large patients. Further, patient size is more accurately measured on projection images if the widest part of the patient, rather than the geometric center of the patient, is positioned at scanner isocenter.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-11: Feasibility Study of Markerless Tracking Using Dual Energy Fluoroscopic Images for Real-Time Tumor-Tracking Radiotherapy System

Purpose: The new real-time tumor-tracking radiotherapy (RTRT) system was installed in our institution. This system consists of two x-ray tubes and color image intensifiers (I.I.s). The fiducial marker which was implanted near the tumor was tracked using color fluoroscopic images. However, the implantation of the fiducial marker is very invasive. Color fluoroscopic images enable to increase the recognition of the tumor. However, these images were not suitable to track the tumor without fiducial marker. The purpose of this study was to investigate the feasibility of markerless tracking using dual energy colored fluoroscopic images for real-time tumor-tracking radiotherapy system. Methods: The colored fluoroscopic images of static and moving phantom that had the simulated tumor (30 mm diameter sphere) were experimentally acquired using the RTRT system. The programmable respiratory motion phantom was driven using the sinusoidal pattern in cranio-caudal direction (Amplitude: 20 mm, Time: 4 s). The x-ray condition was set to 55 kV, 50 mA and 105 kV, 50 mA for low energy and high energy, respectively. Dual energy images were calculated based on the weighted logarithmic subtraction of high and low energy images of RGB images. The usefulness of dual energy imaging for real-time tracking with an automated template image matching algorithm was investigated. Results: Our proposed dual energy subtraction improve the contrast between tumor and background to suppress the bone structure. For static phantom, our results showed that high tracking accuracy using dual energy subtraction images. For moving phantom, our results showed that good tracking accuracy using dual energy subtraction images. However, tracking accuracy was dependent on tumor position, tumor size and x-ray conditions. Conclusion: We indicated that feasibility of markerless tracking using dual energy fluoroscopic images for real-time tumor-tracking radiotherapy system. Furthermore, it is needed to investigate the tracking accuracy using proposed dual energy subtraction images for clinical cases.

60 APPLIED LIFE SCIENCES↗

Site symmetry of AO{sub 4} complexes (A are s- or p-elements of periods III and IV) in crystal structures

The symmetry of the sites occupied in crystal structures by 17 405 crystallographically different A atoms (A are s or p elements of periods III and IV) entering the composition of AO{sub 4}{sup z-} complexes has been analyzed. A periodicity in the ability of A atoms for implementing a certain site symmetry is established. Some features of the stereochemistry of A elements in the dependence of their position in the periodic table are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Statistical description of the motion of dislocation kinks in a random field of impurities adsorbed by a dislocation

A model has been proposed for describing the influence of impurities adsorbed by dislocation cores on the mobility of dislocation kinks in materials with a high crystalline relief (Peierls barriers). The delay time spectrum of kinks at statistical fluctuations of the impurity density has been calculated for a sufficiently high energy of interaction between impurities and dislocations when the migration potential is not reduced to a random Gaussian potential. It has been shown that fluctuations in the impurity distribution substantially change the character of the migration of dislocation kinks due to the slow decrease in the probability of long delay times. The dependences of the position of the boundary of the dynamic phase transition to a sublinear drift of kinks x {proportional_to} t{sup {delta}} ({delta} {sigma} 1) and the characteristics of the anomalous mobility on the physical parameters (stress, impurity concentration, experimental temperature, etc.) have been calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Collective excitations in optical spectra of nanosize exciton and electron-positron droplets

We study the optical properties of nanosize two-component Fermi systems. The photoabsorption spectra in Fermi systems containing not more than 10{sup 2} pairs of oppositely charged particles are calculated. The main focus is on the role of collective plasmon excitations. The dependences of the position of the plasmon resonance on the number of particles and the ratio of their masses in the system are investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical and structural properties of ensembles of colloidal Ag{sub 2}S quantum dots in gelatin

The size dependences of the absorption and luminescence spectra of ensembles of hydrophilic colloidal Ag{sub 2}S quantum dots produced by the sol-gel method and dispersed in gelatin are analyzed. By X-ray diffraction analysis and transmission electron microscopy, the formation of core/shell nanoparticles is detected. The characteristic feature of the nanoparticles is the formation of crystalline cores, 1.5–2.0 nm in dimensions, and shells of gelatin and its complexes with the components of synthesis. The observed slight size dependence of the position of infrared photoluminescence bands (in the range 1000–1400 nm) in the ensembles of hydrophilic colloidal Ag{sub 2}S quantum dots is explained within the context of the model of the radiative recombination of electrons localized at structural and impurity defects with free holes.

36 MATERIALS SCIENCE↗

PbSnTe:In compound: Electron capture levels, galvanomagnetic properties, and THz sensitivity

A model of the Pb{sub 1–x}Sn{sub x}Te:In compound, based on concepts of the theory of disordered systems is considered. The temperature dependences of the Fermi-level position and carrier concentration are calculated depending on the indium doping level and are compared with experimental data. The transient current–voltage characteristics are calculated in the mode of injection from the contact and current limitation by space charge at various voltage-variation rates. The data obtained are compared with the experiments. It is demonstrated that the shape of the characteristics is controlled by the parameters of electron capture at localized states. Photocurrent relaxation in a magnetic field is studied, and the mechanism of such relaxation is discussed under the assumption of the magnetic freezing of carriers.

36 MATERIALS SCIENCE↗

Silicon Nanopillar Microarrays: Formation and Resonance Reflection of Light

Abstract—The results of investigating the spectral characteristics of reflection from silicon nanopillar (Si NP) microarrays in the wavelength region from 400 to 1100 nm are presented. The Si nanopillars are formed by electron lithography on a negative resist with subsequent reactive ion etching. The Si nanopillars are etched through a resist mask and SiO{sub 2} 100 nm thick. In the spectra of reflection from nanopillar microarrays, minima are observed, the position of which depends strongly on the Si nanopillar diameter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inverse Subspace Iteration for Spectral Stochastic Finite Element Methods

We study random eigenvalue problems in the context of spectral stochastic finite elements. In particular, given a parameter-dependent, symmetric positive-definite matrix operator, we explore the performance of algorithms for computing its eigenvalues and eigenvectors represented using polynomial chaos expansions. We formulate a version of stochastic inverse subspace iteration, which is based on the stochastic Galerkin finite element method, and we compare its accuracy with that of Monte Carlo and stochastic collocation methods. The coefficients of the eigenvalue expansions are computed from a stochastic Rayleigh quotient. Our approach allows the computation of interior eigenvalues by deflation methods, and we can also compute the coefficients of multiple eigenvectors using a stochastic variant of the modified Gram-Schmidt process. The effectiveness of the methods is illustrated by numerical experiments on benchmark problems arising from vibration analysis.

97 MATHEMATICS AND COMPUTING↗

Defect specific luminescence dead layers in CdS and CdSe

CdS and CdSe are often used in optoelectronic devices whose effectiveness is may be dictated by defects in the near surface region. Luminescence is one of the main tools for studying such defects. The energy dependence of the x-ray excited optical luminescence (XEOL) spectra of these materials enables the extraction of the depth dependence of the defect distribution. Normal and time-gated XEOL spectra were obtained from these materials in the energy range 600 to 1500 eV. Here, we find that the results can best be understood in terms of a luminescence dead layer whose width depends on the position of the defect level in the band gap.

36 MATERIALS SCIENCE↗

Effect of Solvent Motion on Ion Transport in Electrolytes

We use concentrated solution theory to derive an equation governing solvent velocity in a binary electrolyte when a current passes through it. This equation, in combination with the material balance equation, enables the prediction of electrolyte concentration profiles and species velocities as a function of space and time. This framework is used to predict ion velocities in Li-Li symmetric cells containing a mixture of lithium bis(trifluoromethanesulfonyl)imide and poly(ethylene oxide) (LiTFSI/PEO), for which the cation transference number relative to the solvent velocity, ${t}_{+}^{0},$ can be either positive or negative, depending on salt concentration. Accounting for the solvent motion is increasingly important at higher concentrations. Especially for negative ${t}_{+}^{0},$ if solvent velocity is set to zero, the cation velocity, based on the electrode-electrolyte interface reference frame, is pointed opposite to the current flow. However, when solvent motion is taken into account, the cation velocity, based on the same reference frame, is in the same direction as the current. This analysis demonstrates the importance of accounting for solvent velocity rigorously in seemingly simple systems such as symmetric cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗