Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

The Effect of Quantum-Mechanical Interference on Precise Measurements of the n = 2 Triplet P Fine Structure of Helium

For many decades, improvements in both theory and experiment of the fine structure of the n = 2 triplet P levels of helium have allowed for an increasingly precise determination of the fine-structure constant. Recently, it has been observed that quantum-mechanical interference between neighboring resonances can cause significant shifts, even if such neighboring resonances are separated by thousands of natural widths. The shifts depend in detail on the experimental method used for the measurement, as well as the specific experimental parameters employed. Here, we review how these shifts apply for the most precise measurements of the helium 2{sup 3}P fine-structure intervals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Instrument for precision long-term β-decay rate measurements

We describe an experimental setup for making precision measurements of relative β-decay rates of {sup 22}Na, {sup 36}Cl, {sup 54}Mn, {sup 60}Co, {sup 90}Sr, {sup 133}Ba, {sup 137}Cs, {sup 152}Eu, and {sup 154}Eu. The radioactive samples are mounted in two automated sample changers that sequentially position the samples with high spatial precision in front of sets of detectors. The set of detectors for one sample changer consists of four Geiger-Müller (GM) tubes and the other set of detectors consists of two NaI scintillators. The statistical uncertainty in the count rate is few times 0.01% per day for the GM detectors and about 0.01% per hour on the NaI detectors. The sample changers, detectors, and associated electronics are housed in a sealed chamber held at constant absolute pressure, humidity, and temperature to isolate the experiment from environmental variations. The apparatus is designed to accumulate statistics over many years in a regulated environment to test recent claims of small annual variations in the decay rates. We demonstrate that absent this environmental regulation, uncontrolled natural atmospheric pressure variations at our location would imprint an annual signal of 0.1% on the Geiger-Müller count rate. However, neither natural pressure variations nor plausible indoor room temperature variations cause a discernible influence on our NaI scintillator detector count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Precise radial distribution of charged particles in a magnetic guiding field

Current high precision beta decay experiments of polarized neutrons, employing magnetic guiding fields in combination with position sensitive and energy dispersive detectors, resulted in a detailed study of the mono-energetic point spread function (PSF) for a homogeneous magnetic field. A PSF describes the radial probability distribution of mono-energetic electrons at the detector plane emitted from a point-like source. With regard to accuracy considerations, unwanted singularities occur as a function of the radial detector coordinate which have recently been investigated by subdividing the radial coordinate into small bins or employing analytical approximations. In this note, a series expansion of the PSF is presented which can numerically be evaluated with arbitrary precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A spectrometer for high-precision ion temperature and velocity measurements in low-temperature plasmas

We have developed a low-cost spectrometer with simple optical design that achieves unprecedented precision measurements of ion temperature (±0.01 eV) and velocity (±20 m/s). A Fabry-Pérot étalon provides the simultaneous high resolving power and high throughput needed for the light levels available in singly ionized helium and argon plasmas. Reducing the systematic uncertainty in the absolute wavelength calibration needed for the specified velocity precision motivates a Bayesian analysis method called Nested Sampling to address the nontrivial uncertainty in the diffraction order. An initial emission measurement of a singly charged stationary argon plasma yields a temperature of 0.339 ± 0.007 eV and a velocity of -3 ± 4 m/s with a systematic uncertainty of 20 m/s.

47 OTHER INSTRUMENTATION↗

Precise equilibrium structures of 1 H - and 2 H -1,2,3-triazoles (C 2 H 3 N 3 ) by millimeter-wave spectroscopy

The 1H- and 2H-1,2,3-triazoles are isomeric five-membered ring, aromatic heterocycles that may undergo chemical equilibration by virtue of intramolecular hydrogen migration (tautomerization). Using millimeter-wave spectroscopy in the 130–375 GHz frequency range, we measured the spectroscopic constants for thirteen 1H-1,2,3-triazole and sixteen 2H-1,2,3-triazole isotopologues. Herein, we provide highly accurate and highly precise semi-experimental equilibrium (r e SE ) structures for the two tautomers based on the spectroscopic constants of each set of isotopologues, together with vibration–rotation interaction and electron-mass distribution corrections calculated using coupled-cluster singles, doubles, and perturbative triples calculations [CCSD(T)/cc-pCVTZ]. The resultant structures are compared with a “best theoretical estimate” (BTE), which has recently been shown to be in exceptional agreement with the semi-experimental equilibrium structures of other aromatic molecules. Bond distances of the 1H tautomer are determined to <0.0008 Å and bond angles to <0.2°. For the 2H tautomer, bond angles are also determined to <0.2°, but bond distances are less precise (2σ ≤ 0.0015). Finally, agreement between BTE and r e SE values is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct stellarator coil optimization for nested magnetic surfaces with precise quasi-symmetry

We present a robust optimization algorithm for the design of electromagnetic coils that generate vacuum magnetic fields with nested flux surfaces and precise quasi-symmetry. The method is based on a bilevel optimization problem, where the outer coil optimization is constrained by a set of inner least squares optimization problems whose solutions describe magnetic surfaces. The outer optimization objective targets coils that generate a field with nested magnetic surfaces and good quasi-symmetry. The inner optimization problems identify magnetic surfaces when they exist, and approximate surfaces in the presence of magnetic islands or chaos. We show that this formulation can be used to heal islands and chaos, thus producing coils that result in magnetic fields with precise quasi-symmetry. We show that the method can be initialized with coils from the traditional two-stage coil design process, as well as coils from a near-axis expansion optimization. We present a numerical example where island chains are healed and quasi-symmetry is optimized up to surfaces with aspect ratio 6. Another numerical example illustrates that the aspect ratio of nested flux surfaces with optimized quasi-symmetry can be decreased from 6 to approximately 4. In conclusion, the last example shows that our approach is robust and a cold-start using coils from a near-axis expansion optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High precision control of laser energy for laser–matter interaction studies

Precise, highly reproducible control of the laser energy is required for high confidence laser–matter interaction research such as in dynamic compression science and high energy density physics. The energy must be adjustable without affecting the pulse shape (time varying intensity) or beam smoothness. We have developed a convenient two-stage energy tuning method for a nominal 100 J, 351 nm (UV) laser. The energy is adjusted in 10 J (10%) increments by operating the laser at full energy and inserting a beam splitter in the laser output. As the splitter is located after the final frequency tripling optics, the UV pulse shape is unchanged. The energy is varied by substituting a splitter of different reflectivity. For finer 3 J (3%) increments, the infrared pulse is attenuated inside the laser before the final amplifier. This requires modest tuning to preserve the pulse shape. The demonstrated variation in shot-to-shot reproducibility is less than +/–2.5 J (5% of the full energy), irrespective of the laser output energy. These approaches can be adapted to most ~100 J class lasers. We describe these techniques and show two examples where they have elucidated the underlying physics in laser shock compression experiments. One used only the beam splitters to establish the pressure for melting in iron. The other combined both techniques to finely increment the peak stress (~2 GPa steps) in germanium to precisely determine the onset and completion of melting—including the melting kinetics. Furthermore, these unambiguous results would not be possible without the developments described here.

47 OTHER INSTRUMENTATION↗

Precise Fermi level engineering in a topological Weyl semimetal via fast ion implantation

The precise controllability of the Fermi level is a critical aspect of quantum materials. For topological Weyl semimetals, there is a pressing need to fine-tune the Fermi level to the Weyl nodes and unlock exotic electronic and optoelectronic effects associated with the divergent Berry curvature. However, in contrast to two-dimensional materials, where the Fermi level can be controlled through various techniques, the situation for bulk crystals beyond laborious chemical doping poses significant challenges. Here, we report the milli-electron-volt (meV) level ultra-fine-tuning of the Fermi level of bulk topological Weyl semimetal tantalum phosphide using accelerator-based high-energy hydrogen implantation and theory-driven planning. By calculating the desired carrier density and controlling the accelerator profiles, the Fermi level can be experimentally fine-tuned from 5 meV below, to 3.8 meV below, to 3.2 meV above the Weyl nodes. High-resolution transmission electron microscopy reveals the crystalline structure is largely maintained under irradiation, while electrical transport indicates that Weyl nodes are preserved and carrier mobility is also largely retained. Our work demonstrates the viability of this generic approach to tune the Fermi level in semimetal systems and could serve to achieve property fine-tuning for other bulk quantum materials with ultrahigh precision.

36 MATERIALS SCIENCE↗

Improving the precision of forces in real-space pseudopotential density functional theory

The high-order finite difference real-space pseudopotential density functional theory (DFT) approach is a valuable method for large-scale, massively parallel DFT calculations. A significant challenge in the approach is the oscillating “egg-box” error introduced by aliasing associated with a coarse grid spacing. To address this issue while minimizing computational cost, we developed a finite difference interpolation (FDI) scheme [Roller et al., J. Chem. Theory Comput. 19, 3889 (2023)] as a means of exploiting the high resolution of the pseudopotential to reduce egg-box effects systematically. Here, we show an implementation of this method in the PARSEC code and examine the practical utility of the combination of FDI with additional methods for improving force precision and/or reducing its computational cost, including orbital-based forces, compensating charges (namely, adding and subtracting a judiciously chosen charge density such that the total density is unaltered), and a modified spatial domain in which the real-space grid is defined. Using selected small molecules, as well as metallic Li, as test cases, we show that a combination of all four aspects leads to a significant reduction in computational cost while retaining a high level of precision that supports accurate structures and vibrational spectra, as well as stable and accurate molecular dynamics runs.

Chemistry↗

Direct integration of atomic precision advanced manufacturing into middle-of-line silicon fabrication

Atomic precision advanced manufacturing (APAM) dopes silicon with enough carriers to change its electronic structure and can be used to create novel devices by defining metallic regions whose boundaries have single-atom abruptness. Incompatibility with the thermal and lithography process requirements for gated silicon transistor manufacturing have inhibited exploration of both how APAM can enhance CMOS performance and how transistor manufacturing steps can accelerate the discovery of new APAM device concepts. In this work, we introduce an APAM process that enables direct integration into the middle of a transistor manufacturing workflow. We show that a process that combines sputtering and annealing with a hardmask preserves a defining characteristic of APAM, a doping density far in excess of the solid solubility limit, while trading another, the atomic precision, for compatibility with manufacturing. The electrical characteristics of a chip combining a transistor with an APAM resistor show that the APAM module has only affected the transistor through the addition of a resistance and not by altering the transistor. This proof-of-concept demonstration also outlines the requirements and limitations of a unified APAM tool, which could be introduced into manufacturing environments, greatly expanding access to this technology and inspiring a new generation of devices with it.

Chemical vapor deposition↗

Evaluating the Accuracy and Precision of Multiple Abundance Estimators Using State-Space Models: A Case Study for a Threatened Population of Chinook Salmon in Johnson Creek, Idaho

Abstract Over the last century, Chinook Salmon Oncorhynchus tshawytscha populations in the Pacific Northwest have experienced dramatic declines, leading to many of them being listed as threatened under the Endangered Species Act. The abundance of these threatened populations relative to the thresholds for delisting remains the primary metric for assessing recovery, yet determining the true population abundances from multiple survey types with unknown levels of accuracy and precision remains difficult. The abundance of the spring–summer Chinook Salmon population in Johnson Creek, Idaho, has been measured using a mark–recapture survey and three different redd count surveys (RCSs) that vary temporally and spatially. Using a state-space model, we determined the accuracy and precision of each survey type by decoupling the observation error of the survey from the process error describing the annual variability in the true population abundance. We then extended the results of the model to determine the risk of managers’ incorrectly delisting the population (a type I error) or incorrectly keeping it listed (a type II error). Finally, we show that salmon managers with data-limited populations (primarily those with only single-pass index RCSs) might use the results of our risk analysis to determine whether expanding survey efforts to minimize management risks is appropriate when they are confronted with dwindling financial resources. For example, we determined that although both the multiple-pass extended RCS (CV = 0.06) and mark–recapture surveys (CV = 0.14) provide unbiased estimates of salmon abundance in Johnson Creek, the mark–recapture study can have annual costs that are 30–100 times greater. Managers may determine that directing research funds toward acquiring information unique to weir-based mark–recapture surveys (i.e., migration timing, good genetics samples, etc.) may not be justified for all populations. Received October 7, 2013; accepted March 5, 2014

Chasco, Brandon E.↗

HIGH-PRECISION ASTROMETRIC MILLIMETER VERY LONG BASELINE INTERFEROMETRY USING A NEW METHOD FOR ATMOSPHERIC CALIBRATION

We describe a new method which achieves high-precision very long baseline interferometry (VLBI) astrometry in observations at millimeter (mm) wavelengths. It combines fast frequency-switching observations, to correct for the dominant non-dispersive tropospheric fluctuations, with slow source-switching observations, for the remaining ionospheric dispersive terms. We call this method source-frequency phase referencing. Provided that the switching cycles match the properties of the propagation media, one can recover the source astrometry. We present an analytic description of the two-step calibration strategy, along with an error analysis to characterize its performance. Also, we provide observational demonstrations of a successful application with observations using the Very Long Baseline Array at 86 GHz of the pairs of sources 3C274 and 3C273 and 1308+326 and 1308+328 under various conditions. We conclude that this method is widely applicable to mm-VLBI observations of many target sources, and unique in providing bona fide astrometrically registered images and high-precision relative astrometric measurements in mm-VLBI using existing and newly built instruments, including space VLBI.

79 ASTRONOMY AND ASTROPHYSICS↗

PRECISION SPECTROPHOTOMETRY AT THE LEVEL OF 0.1%

Accurate relative spectrophotometry is critical for many science applications. Small wavelength-scale residuals in the flux calibration can significantly impact the measurements of weak emission and absorption features in the spectra. Using Sloan Digital Sky Survey data, we demonstrate that the average spectra of carefully selected red-sequence galaxies can be used as a spectroscopic standard to improve the relative spectrophotometry precision to 0.1% on small wavelength scales (from a few to hundreds of Angstroms). We achieve this precision by comparing stacked spectra across tiny redshift intervals. The redshift intervals must be small enough that any systematic stellar population evolution is minimized and is less than the spectrophotometric uncertainty. This purely empirical technique does not require any theoretical knowledge of true galaxy spectra. It can be applied to all large spectroscopic galaxy redshift surveys that sample a large number of galaxies in a uniform population.

79 ASTRONOMY AND ASTROPHYSICS↗

Kepler eclipsing binary stars. IV. Precise eclipse times for close binaries and identification of candidate three-body systems

We present a catalog of precise eclipse times and analysis of third-body signals among 1279 close binaries in the latest Kepler Eclipsing Binary Catalog. For these short-period binaries, Kepler's 30 minute exposure time causes significant smearing of light curves. In addition, common astrophysical phenomena such as chromospheric activity, as well as imperfections in the light curve detrending process, can create systematic artifacts that may produce fictitious signals in the eclipse timings. We present a method to measure precise eclipse times in the presence of distorted light curves, such as in contact and near-contact binaries which exhibit continuously changing light levels in and out of eclipse. We identify 236 systems for which we find a timing variation signal compatible with the presence of a third body. These are modeled for the light travel time effect and the basic properties of the third body are derived. This study complements J. A. Orosz et al. (in preparation), which focuses on eclipse timing variations of longer period binaries with flat out-of-eclipse regions. Together, these two papers provide comprehensive eclipse timings for all binaries in the Kepler Eclipsing Binary Catalog, as an ongoing resource freely accessible online to the community.

79 ASTRONOMY AND ASTROPHYSICS↗

PRECISION MEASUREMENTS OF THE CLUSTER RED SEQUENCE USING AN ERROR-CORRECTED GAUSSIAN MIXTURE MODEL

The red sequence is an important feature of galaxy clusters and plays a crucial role in optical cluster detection. Measurement of the slope and scatter of the red sequence are affected both by selection of red sequence galaxies and measurement errors. In this paper, we describe a new error-corrected Gaussian Mixture Model for red sequence galaxy identification. Using this technique, we can remove the effects of measurement error and extract unbiased information about the intrinsic properties of the red sequence. We use this method to select red sequence galaxies in each of the 13,823 clusters in the maxBCG catalog, and measure the red sequence ridgeline location and scatter of each. These measurements provide precise constraints on the variation of the average red galaxy populations in the observed frame with redshift. We find that the scatter of the red sequence ridgeline increases mildly with redshift, and that the slope decreases with redshift. We also observe that the slope does not strongly depend on cluster richness. Using similar methods, we show that this behavior is mirrored in a spectroscopic sample of field galaxies, further emphasizing that ridgeline properties are independent of environment. These precise measurements serve as an important observational check on simulations and mock galaxy catalogs. The observed trends in the slope and scatter of the red sequence ridgeline with redshift are clues to possible intrinsic evolution of the cluster red sequence itself. Most importantly, the methods presented in this work lay the groundwork for further improvements in optically based cluster cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

DISSECTING THE GRAVITATIONAL LENS B1608+656. II. PRECISION MEASUREMENTS OF THE HUBBLE CONSTANT, SPATIAL CURVATURE, AND THE DARK ENERGY EQUATION OF STATE

Strong gravitational lens systems with measured time delays between the multiple images provide a method for measuring the 'time-delay distance' to the lens, and thus the Hubble constant. We present a Bayesian analysis of the strong gravitational lens system B1608+656, incorporating (1) new, deep Hubble Space Telescope (HST) observations, (2) a new velocity-dispersion measurement of 260 +- 15 km s{sup -1} for the primary lens galaxy, and (3) an updated study of the lens' environment. Our analysis of the HST images takes into account the extended source surface brightness, and the dust extinction and optical emission by the interacting lens galaxies. When modeling the stellar dynamics of the primary lens galaxy, the lensing effect, and the environment of the lens, we explicitly include the total mass distribution profile logarithmic slope gamma' and the external convergence kappa{sub ext}; we marginalize over these parameters, assigning well-motivated priors for them, and so turn the major systematic errors into statistical ones. The HST images provide one such prior, constraining the lens mass density profile logarithmic slope to be gamma' = 2.08 +- 0.03; a combination of numerical simulations and photometric observations of the B1608+656 field provides an estimate of the prior for kappa{sub ext}: 0.10{sup +0.08}{sub -0.05}. This latter distribution dominates the final uncertainty on H{sub 0}. Fixing the cosmological parameters at OMEGA{sub m} = 0.3, OMEGA{sub L}AMBDA = 0.7, and w = -1 in order to compare with previous work on this system, we find H{sub 0} = 70.6{sup +3.1}{sub -3.1} km s{sup -1} Mpc{sup -1}. The new data provide an increase in precision of more than a factor of 2, even including the marginalization over kappa{sub ext}. Relaxing the prior probability density function for the cosmological parameters to that derived from the Wilkinson Microwave Anisotropy Probe (WMAP) five-year data set, we find that the B1608+656 data set breaks the degeneracy between OMEGA{sub m} and OMEGA{sub L}AMBDA at w = -1 and constrains the curvature parameter to be -0.031 < OMEGA{sub k} < 0.009 (95% CL), a level of precision comparable to that afforded by the current Type Ia SNe sample. Asserting a flat spatial geometry, we find that, in combination with WMAP, H{sub 0} = 69.7{sup +4.9}{sub -5.0} km s{sup -1} Mpc{sup -1} and w = -0.94{sup +0.17}{sub -0.19} (68% CL), suggesting that the observations of B1608+656 constrain w as tightly as the current Baryon Acoustic Oscillation data do.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH-PRECISION DYNAMICAL MASSES OF VERY LOW MASS BINARIES

We present the results of a three year monitoring program of a sample of very low mass (VLM) field binaries using both astrometric and spectroscopic data obtained in conjunction with the laser guide star adaptive optics system on the W. M. Keck II 10 m telescope. Among the 24 systems studied, 15 have undergone sufficient orbital motion, allowing us to derive their relative orbital parameters and hence their total system mass. These measurements more than double the number of mass measurements for VLM objects, and include the most precise mass measurement to date (<2%). Among the 11 systems with both astrometric and spectroscopic measurements, six have sufficient radial velocity variations to allow us to obtain individual component masses. This is the first derivation of the component masses for five of these systems. Altogether, the orbital solutions of these low mass systems show a correlation between eccentricity and orbital period, consistent with their higher mass counterparts. In our primary analysis, we find that there are systematic discrepancies between our dynamical mass measurements and the predictions of theoretical evolutionary models (TUCSON and LYON) with both models either underpredicting or overpredicting the most precisely determined dynamical masses. These discrepancies are a function of spectral type, with late-M through mid-L systems tending to have their masses underpredicted, while one T-type system has its mass overpredicted. These discrepancies imply that either the temperatures predicted by evolutionary and atmosphere models are inconsistent for an object of a given mass, or the mass-radius relationship or cooling timescales predicted by the evolutionary models are incorrect. If these spectral-type trends are correct and hold into the planetary mass regime, the implication is that the masses of directly imaged extrasolar planets are overpredicted by the evolutionary models.

79 ASTRONOMY AND ASTROPHYSICS↗

PRECISION DETERMINATION OF ATMOSPHERIC EXTINCTION AT OPTICAL AND NEAR-INFRARED WAVELENGTHS

The science goals for future ground-based all-sky surveys, such as the Dark Energy Survey, PanSTARRS, and the Large Synoptic Survey Telescope, require calibration of broadband photometry that is stable in time and uniform over the sky to precisions of 1% or better, and absolute calibration of color measurements that are similarly accurate. This performance will need to be achieved with measurements made from multiple images taken over the course of many years, and these surveys will observe in less than ideal conditions. This paper describes a technique to implement a new strategy to directly measure variations of atmospheric transmittance at optical wavelengths and application of these measurements to calibration of ground-based observations. This strategy makes use of measurements of the spectra of a small catalog of bright 'probe' stars as they progress across the sky and back-light the atmosphere. The signatures of optical absorption by different atmospheric constituents are recognized in these spectra by their characteristic dependences on wavelength and airmass. State-of-the-art models of atmospheric radiation transport and modern codes are used to accurately compute atmospheric extinction over a wide range of observing conditions. We present results of an observing campaign that demonstrate that correction for extinction due to molecular constituents and aerosols can be done with precisions of a few millimagnitudes with this technique.

79 ASTRONOMY AND ASTROPHYSICS↗