Search NASA⌕ Search

SEARCH · Search NASA

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Electric Adsorption Heat Pump for Electric Vehicles: Electric-Powered Adsorption Heat Pump for Electric Vehicles

HEATS Project: PNNL is developing a new class of advanced nanomaterial called an electrical metal organic framework (EMOF) for EV heating and cooling systems. The EMOF would function similar to a conventional heat pump, which circulates heat or cold to the cabin as needed. However, by directly controlling the EMOF's properties with electricity, the PNNL design is expected to use much less energy than traditional heating and cooling systems. The EMOF-based heat pumps would be light, compact, efficient, and run using virtually no moving parts.

ARPA-E↗

DOE Zero Energy Ready Home Case Study: Greenhill Contracting, Inc., Hickory Ridge

Greenhill Contracting built this 3,912-ft2 house in Gardiner, New York, to the high-performance criteria of the DOE Zero Energy Ready Home (ZERH) program. A highly efficient air-source heat pump heats and cools the home’s interior, while the roof-mounted photovoltaic system offsets electricity usage to cut energy bills to nearly zero. Many months the home owners see a credit on their utility bill.

2017 Housing Innovation Award↗

Systems and methods for flow-synchronous field motion heat transfer

An active regenerator in a magnetocaloric or an electrocaloric heat pump refrigeration system provides more efficient flow of heat. The heat exchange fluid moves synchronously with the motion of a magnetic or electric field. Only a portion of the length of the active regenerator bed is introduced to or removed from the field at one time, giving rise to a hot pulse and a cold pulse. Valves may direct the hot pulse and/or the cold pulse to supplement refrigeration.

Hassen, Charles N.↗

DOE Zero Energy Ready Home Case Study HIA 2021: Insight Homes, The Brenner, Felton, DE

Case study of a DOE 2021 Housing Innovation Award winning custom home in a mixed-humid climate that got a HERS 51 without PV, with 1,940 square feet, MERV 13 filters and low-emission paints, adhesives, and carpeting; plus a sealed, conditioned crawl space, and a high-efficiency gas furnace and heat pump.

Building America, residential construction, home b↗

Sustainable Remediation of Radionuclides By a Common Sense Approach to Enhanced Attenuation - 16441

Development of in situ and relatively passive remedies for treatment of groundwater contaminated by metals and radionuclides is becoming more important because of the difficulty and cost - both to the environment and financially -- of removing these types of contaminants from the subsurface by pump-and-treat or excavation. In situ technologies rely on reactions that tend to remove contaminants from groundwater by partitioning them to solid phases in the aquifer. Monitored natural attenuation (MNA) relies solely on natural reactions to achieve remedial goals. Enhanced attenuation (EA) uses engineered approaches to supplement remediation when MNA is not sufficient to meet remedial goals. Both approaches leave contaminants in the subsurface and require a high burden of proof that contaminants will not be mobilized and become a risk in the future. Proof of the sustained effectiveness of an EA remedy is made much easier by strategic design. In multi-contaminant plumes, it is important to prioritize contaminants according to the risk they pose, with the recognition that one remedy rarely treats all contaminants. The goal for the engineered portion of the remedy should be maximum risk reduction with minimal engineering. Natural attenuation or negotiated alternate concentration levels will often allow low risk contaminants to go untreated. Whenever possible, the remedy should be consistent with the geochemical evolution of the waste site, insuring that the treated immobilized contaminants are likely to remain relatively immobile for long time frames. Finally, use what nature provides geologically, hydrologically, geochemically, or microbiologically in the remedy design. One of the impediments faced by waste site managers in implementing EA remedies is paralysis by perceived complexity. There are things that must be known to design an effective EA remedy, but there is always the temptation to know everything to eliminate the possibility of failure. Furthermore, there are plenty of people warning of failure if all is not known and they are usually willing to help the design team know all, for a price. Yet, the price of trying to eliminate all risk is never implementing an innovative remedy. All parties involved -- scientists/engineers, waste site managers, regulators and stakeholders must assume some degree of risk to deploy an EA remedy. If all parties are to assume some risk, then trust built through close communication from the start is required. The U.S. Department of Energy Office of Environmental Management has funded an applied field research initiative for several years focused, in part, on developing EA remedies for metals and radionuclides using these guiding principles. This approach to EA remedies grew out of developing and deploying a remediation strategy to replace a pump-and-treat system at the F-Area Seepage Basins on the Savannah River Site. The pump-and-treat system was energy intensive, produced several thousand cubic feet of solid radioactive waste per year, and cost $ 1 million per month to operate. The EA remedy that replaced the pump-and-treat is energy efficient, produces no waste, and costs approximately $1 million per year to maintain. At the F-Area Seepage Basins approximately 7 billion liters of low level radioactive waste solutions were disposed in three unlined basins resulting in contaminated groundwater containing various radionuclides and other contaminants. The primary contaminants of concern are tritium, strontium-90, uranium, and iodine-129. Other key features of the contaminant plume are its acidic nature with pH values as low as 3.2, its vertical stratification in the water table aquifer, and the tendency of the most contaminated portions to follow troughs in the top of the clay separating the upper aquifer zone from the lower aquifer zone. The geology was exploited by installing a funnel-and-gate system into the clay with the barrier portion blocking contaminant flow paths in the troughs in the clay. This forces the most contaminated water to flow through the gates where it encounters an in situ treatment zone created by periodic injections of alkaline solution. The flux of tritium has been reduced significantly by the barrier walls. Strontium-90 and uranium are treated by enhanced sorption in the circum-neutral pH treatment zone, consistent with natural geochemical evolution of the waste site from acidic to more neutral pH. An additional in situ treatment zone was created up-gradient of the one of the gates to treat iodine-129. Sub-micrometer diameter silver chloride particles were injected into the aquifer by direct push methods to create the treatment zone. In the laboratory and in a field pilot test the poorly soluble silver chloride particles reacted with iodide to form much less soluble silver iodide. Evaluation of the effectiveness of the silver chloride is ongoing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Staging laser plasma accelerators for increased beam energy

Staging laser plasma accelerators is an efficient way of mitigating laser pump depletion in laser driven accelerators and necessary for reaching high energies with compact laser systems. The concept of staging includes coupling of additional laser energy and transporting the electron beam from one accelerating module to another. Due to laser damage threshold constraints, in-coupling laser energy with conventional optics requires distances between the accelerating modules of the order of 10m, resulting in decreased average accelerating gradient and complicated e-beam transport. In this paper we use basic scaling laws to show that the total length of future laser plasma accelerators will be determined by staging technology. We also propose using a liquid jet plasma mirror for in-coupling the laser beam and show that it has the potential to reduce distance between stages to the cm-scale.

43 PARTICLE ACCELERATORS↗

Excited state absorption of pump radiation as a loss mechanism in solid-state lasers

The characteristics of optical pumping dynamics in laser-pumped, rare-earth-doped, solid-state laser materials are investigated by using a tunable alexandrite laser to pump Y3Al5O12:Nd(3+) in an optical cavity. It is found that the slope efficiency of the Nd laser operation depends strongly on the wavelength of the pump laser. For pump wavelengths resulting in low slope efficiencies, intense fluorescence emission is observed from the sample in the blue-green spectral region. This is attributed to the excited-state absorption of pump photons which occurs during radiationless relaxation from the pump band to the metastable state. This type of process is an important loss mechanism for monochromatic pumping of laser systems at specific pump wavelengths.

Kliewer, Michael L.↗

Electrokinetic pump

A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

Patel, Kamlesh D↗

TANK48 CFD MODELING ANALYSIS

The process of recovering the waste in storage tanks at the Savannah River Site (SRS) typically requires mixing the contents of the tank to ensure uniformity of the discharge stream. Mixing is accomplished with one to four dual-nozzle slurry pumps located within the tank liquid. For the work, a Tank 48 simulation model with a maximum of four slurry pumps in operation has been developed to estimate flow patterns for efficient solid mixing. The modeling calculations were performed by using two modeling approaches. One approach is a single-phase Computational Fluid Dynamics (CFD) model to evaluate the flow patterns and qualitative mixing behaviors for a range of different modeling conditions since the model was previously benchmarked against the test results. The other is a two-phase CFD model to estimate solid concentrations in a quantitative way by solving the Eulerian governing equations for the continuous fluid and discrete solid phases over the entire fluid domain of Tank 48. The two-phase results should be considered as the preliminary scoping calculations since the model was not validated against the test results yet. A series of sensitivity calculations for different numbers of pumps and operating conditions has been performed to provide operational guidance for solids suspension and mixing in the tank. In the analysis, the pump was assumed to be stationary. Major solid obstructions including the pump housing, the pump columns, and the 82 inch central support column were included. The steady state and three-dimensional analyses with a two-equation turbulence model were performed with FLUENT{trademark} for the single-phase approach and CFX for the two-phase approach. Recommended operational guidance was developed assuming that local fluid velocity can be used as a measure of sludge suspension and spatial mixing under single-phase tank model. For quantitative analysis, a two-phase fluid-solid model was developed for the same modeling conditions as the single-phase model. The modeling results show that the flow patterns driven by four pump operation satisfy the solid suspension requirement, and the average solid concentration at the plane of the transfer pump inlet is about 12% higher than the tank average concentrations for the 70 inch tank level and about the same as the tank average value for the 29 inch liquid level. When one of the four pumps is not operated, the flow patterns are satisfied with the minimum suspension velocity criterion. However, the solid concentration near the tank bottom is increased by about 30%, although the average solid concentrations near the transfer pump inlet have about the same value as the four-pump baseline results. The flow pattern results show that although the two-pump case satisfies the minimum velocity requirement to suspend the sludge particles, it provides the marginal mixing results for the heavier or larger insoluble materials such as MST and KTPB particles. The results demonstrated that when more than one jet are aiming at the same position of the mixing tank domain, inefficient flow patterns are provided due to the highly localized momentum dissipation, resulting in inactive suspension zone. Thus, after completion of the indexed solids suspension, pump rotations are recommended to avoid producing the nonuniform flow patterns. It is noted that when tank liquid level is reduced from the highest level of 70 inches to the minimum level of 29 inches for a given number of operating pumps, the solid mixing efficiency becomes better since the ratio of the pump power to the mixing volume becomes larger. These results are consistent with the literature results.

99 GENERAL AND MISCELLANEOUS↗

Energy Factor Analysis for Gas Heat Pump Water Heaters

Gas heat pump water heaters (HPWHs) can improve water heating efficiency with zero GWP and zero ODP working fluids. The energy factor (EF) of a gas HPWH is sensitive to several factors. In this work, expressions are derived for EF of gas HPWHs, as a function of heat pump cycle COP, tank heat losses, burner efficiency, electrical draw, and effectiveness of supplemental heat exchangers. The expressions are used to investigate the sensitivity of EF to each parameter. EF is evaluated on a site energy basis (as used by the US DOE for rating water heater EF), and a primary energy-basis energy factor (PEF) is also defined and included. Typical ranges of values for the six parameters are given. For gas HPWHs, using typical ranges for component performance, EF will be 59 80% of the heat pump cycle thermal COP (for example, a COP of 1.60 may result in an EF of 0.94 1.28). Most of the reduction in COP is due to burner efficiency and tank heat losses. Gas-fired HPWHs are theoretically be capable of an EF of up to 1.7 (PEF of 1.6); while an EF of 1.1 1.3 (PEF of 1.0 1.1) is expected from an early market entry.

Gluesenkamp, Kyle R↗

High-quantum-efficiency infrared up-conversion.

Experimental study in which 100% conversion of infrared photons into visible photons was achieved through three wave interactions in a nonlinear medium. The first experimental evidence of overconversion is presented, and the classical theory of up-conversion in the high-conversion-efficiency region is confirmed. A laser pump light feedback technique is described that promises to make the process practical with modestly powerful pump lasers and less than perfect nonlinear crystals. The nonlinear medium used was a LiIO3 crystal that cannot be 90-deg phase-matched. The 'walk off' that resulted helped make possible the attainment of 100% conversion efficiency.

Gurski, T. R.↗

Multi-disk: concept and realisation of a collinearly pumped multiple thin disk active medium

We analyse the concept of collinearly pumped active medium consisting of multiple thin disks (multi-disk configuration). The multiple disk design is attractive for fabrication of mid- and high-output power laser systems with a good spatial beam quality and high optical efficiency. Two approaches for realisation such multi-disk active elements are considered. Preliminary lasing experiments and numerical calculations for temperature distribution inside the lasing medium are presented. (lasers)

43 PARTICLE ACCELERATORS↗

Direct drive with the argon fluoride laser as a path to high fusion gain with sub-megajoule laser energy

Argon fluoride (ArF) is currently the shortest wavelength laser that can credibly scale to the energy and power required for high gain inertial fusion. ArF's deep ultraviolet light and capability to provide much wider bandwidth than other contemporary inertial confinement fusion (ICF) laser drivers would drastically improve the laser target coupling efficiency and enable substantially higher pressures to drive an implosion. Our radiation hydrodynamics simulations indicate gains greater than 100 are feasible with a sub-megajoule ArF driver. Our laser kinetics simulations indicate that the electron beam-pumped ArF laser can have intrinsic efficiencies of more than 16%, versus about 12% for the next most efficient krypton fluoride excimer laser. We expect at least 10% ‘wall plug' efficiency for delivering ArF light to target should be achievable using solid-state pulsed power and efficient electron beam transport to the laser gas that was demonstrated with the U.S. Naval Research Laboratory's Electra facility. These advantages could enable the development of modest size and lower cost fusion power plant modules. This would drastically change the present view on inertial fusion energy as being too expensive and the power plant size too large.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Super Energy Efficient Design (S.E.E.D.) Home Evaluation

This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the “Super Energy Efficient Design” (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressive energy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Source energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short term testing, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

One joule output from a diode-array-pumped Nd:YAG laser with side-pumped rod geometry

Output of 1.25 J per pulse (1.064 micron) with an absolute optical efficiency of 28 percent and corresponding electrical efficiency of 10 percent was demonstrated in a diode-array-pumped Nd:YAG laser using a side-pumped rod geometry in a master-oscillator/power-amplifier configuration. In Q-switched operation, an output of 0.75 J in a 17-ns pulse was obtained. The fundamental laser output was frequency doubled in KTP with 60 percent conversion efficiency to obtain 0.45 J in a 16-ns pulse at 532 nm. The output beam had high spatial quality with pointing stability better than 40 microrad and a shot-to-shot pulse energy fluctuation of less than +/-3 percent.

Kasinski, Jeffrey J.↗

Semiconductor-metal nanoparticle hybrids with natural and artificial proton pump for hydrogen production

Aspects of the disclosure relate to an efficient entirely man-made nanobio hybrid fabricated through cell-free expression of transmembrane proton pump followed by assembly of the synthetic protein architecture with semiconductor nanoparticles for photocatalytic H2 evolution. The system produces H2 at a turnover rate of 240 μmol of H2 (μmol protein)−1 h−1 under green and 17.74 mmol of H2 (μmol protein)−1 h−1 under white light at ambient conditions, in water at neutral pH with methanol as a sacrificial electron donor. Robsutness and flexibility of this approach allows for systemic manipulation at nanoparticle-bio interface toward directed evolution of energy materials and devices.

Rozhkova, Elena A.↗