Search NASA⌕ Search

SEARCH · Search NASA

Results for “response surface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Design and Information Content of Arrays of Sorption-based Vapor Sensors using Solubility Interactions and Linear Solvation Energy Relationships

The sorption of vapors by the selective polymeric layer on a chemical vapor sensor is described in detail and dissected into fundamental solubility interactions. The sorption process is modeled in terms of solvation parameters for vapor solubility properties and linear solvation energy relationships. The latter relationships model the log of the partition coefficient as the sum of terms related to specific types of interactions. The approaches are particularly applicable to the design and understanding of acoustic wave chemical vapor sensors such as those based on surface acoustic wave devices. It is shown how an understanding of solubility interactions informs the selection of polymers to obtain chemical diversity in sensor arrays and obtain the maximum amount of chemical information. The inherent dimensionality of the array data, as analyzed by principle components analysis, is consistent with this formulation. Furthermore, it is shown how new chemometric methods have been developed to extract the chemical information from array responses in terms of solvation parameters serving as de-scriptors of the detected vapor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wind turbine generators having wind assisted cooling systems and cooling methods

A wind generator includes: a nacelle; a hub carried by the nacelle and including at least a pair of wind turbine blades; and an electricity producing generator including a stator and a rotor carried by the nacelle. The rotor is connected to the hub and rotatable in response to wind acting on the blades to rotate the rotor relative to the stator to generate electricity. A cooling system is carried by the nacelle and includes at least one ambient air inlet port opening through a surface of the nacelle downstream of the hub and blades, and a duct for flowing air from the inlet port in a generally upstream direction toward the hub and in cooling relation to the stator.

17 WIND ENERGY↗

WE-AB-303-04: A Tissue Model of Cherenkov Emission From the Skin Surface During Megavoltage X-Ray Radiotherapy

Purpose: To develop a tissue model of Cherenkov radiation emitted from the skin surface during external beam radiotherapy. Imaging Cherenkov radiation emitted from human skin allows visualization of the beam position and potentially surface dose estimates, and our goal is to characterize the optical properties of these emissions. Methods: We developed a Monte Carlo model of Cherenkov radiation generated in a semi-infinite tissue slab by megavoltage x-ray beams with optical transmission properties determined by a two-layered skin model. We separate the skin into a dermal and an epidermal layer in our model, where distinct molecular absorbers modify the Cherenkov intensity spectrum in each layer while we approximate the scattering properties with Mie and Rayleigh scattering from the highly structured molecular organization found in human skin. Results: We report on the estimated distributions of the Cherenkov wavelength spectrum, emission angles, and surface distribution for the modeled irradiated skin surface. The expected intensity distribution of Cherenkov radiation emitted from skin shows a distinct intensity peak around 475 nm, the blue region of the visible spectrum, between a pair of optical absorption bands in hemoglobin and a broad plateau beginning near 600 nm and extending to at least 700 nm where melanin and hemoglobin absorption are both low. We also find that the Cherenkov intensity decreases with increasing angle from the surface normal, the majority being emitted within 20 degrees of the surface normal. Conclusion: Our estimate of the spectral distribution of Cherenkov radiation emitted from skin indicates an advantage to using imaging devices with long wavelength spectral responsivity. We also expect the most efficient imaging to be near the surface normal where the intensity is greatest; although for contoured surfaces, the relative intensity across the surface may appear to vary due to decreasing Cherenkov intensity with increased angle from the skin normal. This research was supported in part by a GAANN Fellowship from the Department of Education.

60 APPLIED LIFE SCIENCES↗

Resource allocation for reliability of a complex system with aging components

To assess the reliability of a complex system, many different types of data may be available. Full-system tests are the most direct measure of reliability, but may be prohibitively expensive or difficult to obtain. Other less direct measures, such as component or section level tests, may be cheaper to obtain and more readily available. Using a single Bayesian analysis, multiple sources of data can be combined to give component and system reliability estimates. Resource allocation looks to develop methods to predict which new data would most improve the precision of the estimate of system reliability, in order to maximally improve understanding. In this paper, we consider a relatively simple system with different types of data from the components and system. We present a methodology for assessing the relative improvement in system reliability estimation for additional data from the various types. Various metrics for comparing improvement and a response surface approach to modeling the relationship between improvement and the additional data are presented.

99 GENERAL AND MISCELLANEOUS↗

Bi2O2(OH)NO3/AgI heterojunction with enhanced UV and visible-light responsive photocatalytic activity and mechanism investigation

Highlights: • Bi{sub 2}O{sub 2}(OH)NO{sub 3}/AgI heterojunction is obtained by in-situ crystallization method. • It shows a higher degradation activity than Bi{sub 2}O{sub 2}(OH)NO{sub 3} and AgI under UV light. • It shows a higher catalytic activity than Bi{sub 2}O{sub 2}(OH)NO{sub 3} and AgI under visible light. • Enhanced charge separation is responsible for the enhanced degradation activity. - Abstract: Fabricating heterojunction between a wide-band-gap semiconductor and a narrow-band-gap semiconductor has become an important strategy to simultaneously improve the photoabsorption and charge separation. In this work, a new heterojunction photocatalyst Bi{sub 2}O{sub 2}(OH)NO{sub 3}/AgI was prepared through a facile in-situ crystallization method under ambient atmosphere. The crystal morphology, surface structure and element distribution were investigated by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive X-ray (EDX) mapping and X-ray photoelectron spectroscopy (XPS). Compared with the pristine Bi{sub 2}O{sub 2}(OH)NO{sub 3} and AgI, Bi{sub 2}O{sub 2}(OH)NO{sub 3}/AgI shows much enhanced degradation performance for eliminating MO regardless of UV or visible light. Photocurrent, electrochemical impedance spectra (EIS) and photoluminescence (PL) demonstrated that the enhanced photocatalytic activity is ascribed to the greatly promoted charge separation and transfer resulted from the matchable band energy levels of Bi{sub 2}O{sub 2}(OH)NO{sub 3} and AgI, favoring the formation of heterojunction. In addition, according to the active species trapping experiment, the main active species are superoxide radicals (O{sub 2}{sup −}) and holes (h{sup +}) during the degradation process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Processing dependence of mechanical properties of metallic glass nanowires

Compared to their crystalline counterparts, nanowires made of metallic glass have not only superb properties but also remarkable processing ability. They can be processed easily and cheaply like plastics via a wide range of methods. To date, the underlying mechanisms of how these different processing routes affect the wires' properties as well as the atomic structure remains largely unknown. Here, by using atomistic modeling, we show that different processing methods can greatly influence the mechanical properties. The nanowires made via focused ion beam milling and embossing exhibit higher strength but localized plastic deformation, whereas that made by casting from liquid shows excellent ductility with homogeneous deformation but reduced strength. The different responses are reflected sensitively in the underlying atomic structure and packing density, some of which have been observed experimentally. The presence of the gradient of alloy concentration and surface effect will be discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Are those bugs reflective? Non-destructive biofilm imaging with white light interferometry

White light interferometry (WLI) is not typically used to image bacterial biofilms that are immersed in water because there is insufficient refractive index contrast to induce reflection from the biofilm’s interface. The soft structure and water-like bulk properties of hydrated biofilms make them difficult to characterize in situ by any means, especially in a non-destructive manner. Here we describe a new method for measuring and monitoring the thickness and topology of live biofilms using a WLI microscope. A microfluidic system was used to create a reflective interface on the surface of biofilms. Live biofilm samples were monitored non-destructively over time. The method enables surface metrology measurements (roughness, surface area) and a novel approach to measuring thickness of the thin hydrated biofilms. Increase in surface roughness preceded observable increase in biofilm thickness, indicating that this measure may be used to predict future development of biofilms. We have also developed a flow cell that enables WLI biofilm imaging in a dynamic environment. We have used this flow cell to observe changes in biofilm structure in response to changes in environmental conditions - flow velocity, availability of nutrients, and presence of biocides.

bacteria↗

Method of evaluating pH using a metallic nanoparticle incorporated nanocomposite-based optical pH sensor

A method for evaluating the pH of an aqueous solution by utilizing the optical properties of a pH sensing material comprised of plurality of optically active nanoparticles dispersed in matrix material. The optically active nanoparticles have an electronic conductivity greater than about 10−1 S/cm and generally have an average nanoparticle diameter of less that about 500 nanometers, and the matrix material is a material which experiences a change in surface charge density over a pH range from 2.0 to 12.0 of at least 1%. The method comprises contacting the pH sensing material and the aqueous solution, illuminating the pH sensing material, and monitoring an optical signal generated through comparison of incident light and exiting light to determine the optical transmission, absorption, reflection, and/or scattering of the pH sensitive material. The optical signal of the pH sensitive material varies in response to the pH of the aqueous solution.

Ohodnicki, Jr., Paul R.↗

Nanoscale mass conveyors

A mass transport method and device for individually delivering chargeable atoms or molecules from source particles is disclosed. It comprises a channel; at least one source particle of chargeable material fixed to the surface of the channel at a position along its length; a means of heating the channel; and a means for applying an controllable electric field along the channel, whereby the device transports the atoms or molecules along the channel in response to applied electric field. In a preferred embodiment, the mass transport device will comprise a multiwalled carbon nanotube (MWNT), although other one dimensional structures may also be used. The MWNT or other structure acts as a channel for individual or small collections of atoms due to the atomic smoothness of the material. Also preferred is a source particle of a metal such as indium. The particles move by dissociation into small units, in some cases, individual atoms. The particles are preferably less than 100 nm in size.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cosmogenic 10Be constraints on deglacial snowline rise in the Southern Alps, New Zealand

We report geochronological dating of glacial landforms, such as terminal and lateral moraines, is useful for determining the extent and timing of past glaciation and for reconstructing the magnitude and rate of past climate changes. In the Southern Alps of New Zealand, well-dated glacial geomorphological records constrain the last glacial cycle across much of the Waitaki River basin (e.g. Ōhau, Pukaki, Tekapo) but its southern sector such as the Ahuriri River valley remains comparatively unconstrained. Recently, there has been debate on the scale and rapidity of mountain glacier retreat during the last glacial termination, particularly the 20–17 ka period in New Zealand. Missing from this debate is well-constrained equilibrium-line altitude (ELA) and associated temperature reconstructions, particularly over the period around 17 ka, which can help us to develop a more complete picture of how past temperature changes drove glacier retreat. Here we report the first glacial chronology dataset from the Last Glacial Maximum (LGM) and subsequent deglaciation from the Ahuriri River valley, Southern Alps, New Zealand (44°23'54"S, 169°39'48"E) based on 38 beryllium-10 ( 10 Be) surface-exposure ages from terminal moraine systems and glaciated bedrock situated at the lower and middle sections of the valley. Our results show that the former Ahuriri Glacier reached its maximum extent at 19.8 ± 0.3 ka, which coincides with the global Last Glacial Maximum. By 16.7 ± 0.3 ka, the glacier had retreat ~18 km up-valley suggesting at least ~43% glacier-length loss relative to its full LGM extent. This deglaciation was accompanied by the formation of a shallow proglacial lake. Using the accumulation area ratio (AAR) method, we estimate that the ELA was lower than present by ~880 m (~1120 m a.s.l.) at 19.8 ± 0.3 ka, and ~770 m lower (~1230 m a.s.l.) at 16.7 ± 0.3 ka. Applying an estimate for temperature lapse rate, this ELA anomaly implies that local air temperature was 5 ± 1 °C colder than present (1981–2010) at 19.8 ± 0.3 ka, while it was 4.4 ± 0.9 °C colder at 16.7 ± 0.3 ka, assuming no change in precipitation. The substantial glacier retreat in response to a relatively small accompanying increases in ELA (110 m) and temperature (0.6 °C) may have been a result of the high glacier-length sensitivity of this glacier system due to its low gradient of former ice surface. Our low warming estimate differs markedly from other deglaciation studies, specifically from Rakaia River valley, which reports a much larger temperature increase at the onset of the last deglaciation. This precisely-dated moraine record along with reconstructed ELA as proxies for atmospheric conditions, provides new insight into post LGM glacier behaviour and climate conditions in New Zealand.

58 GEOSCIENCES↗

A direct evidence of vibrationally delocalized response at ice surface

Surface-specific vibrational spectroscopic responses at isotope diluted ice and amorphous ice are investigated by molecular dynamics (MD) simulations combined with quantum mechanics/molecular mechanics calculations. The intense response specific to the ordinary crystal ice surface is predicted to be significantly suppressed in the isotopically diluted and amorphous ices, demonstrating the vibrational delocalization at the ordinary ice surface. The collective vibration at the ice surface is also analyzed with varying temperature by the MD simulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

INTER-DIGITAL CAPACITIVE SENSOR FOR EVALUATING CABLE INSULATION THROUGH JACKET

Interdigital capacitive (IDC) sensors have previously been used to measure cable-age/damage indicative dielectric properties of cable insulation when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket precluding direct contact with the insulation. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, an IDC to measure the effect of cable polymer dielectric change through a covering jacket has been developed. The IDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. On one electrode, the gap is 5 mm while on the other, the gap is 2 mm. Electric field depth-of-field penetrations are similar to the electrode gaps. The electrodes are printed on a flexible substrate that can be conformed to the outside jacketed surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. For jacketed cable systems, the IDC response is dominated by the jacket but, by analyzing measurements from IDC sensors with different depths-of-field penetration into the cable under test, the influence of the cable jacket material (primarily influenced by the shallow-depth-of field IDC) can be separated from the deeper-depth-of-field IDC sensing the combined effects of both jacket and underlying insulation. No other NDE method is known that is capable of sensing insulation dielectric properties through an overlying jacket.

Cable NDE, Interdigital Capacitance, Insulation Pe↗

Computed tomography dose measurements with radiochromic films and a flatbed scanner

Gafchromic XR-QA films were developed for patient dosimetry in diagnostic radiology. A possible application of these films is the measurement of doses in computed tomography. In this study a method to evaluate the CTDI using Gafchromic XR-QA film and a flatbed scanner was developed and tested. Film samples were cut to dimensions of 6x170 mm{sup 2} in order to have an integration area similar to that of a pencil ionization chamber, with the possibility of changing the integration length. Prior to exposing these films to a computed tomography beam, the angular dependence of the film dose response was investigated by exposing film strips to a static x-ray beam at different angles in the range 0 deg. - 180 deg. A difference of 49% was found between the response with the axis beam parallel to the film surface (90 deg.) and with the axis beam perpendicular (0 deg. and 180 deg.). Integrating over a 360 deg. exposure like the one in computed tomography, a difference of less than 2% was estimated, which is comparable with the measurement error obtainable with XR-QA film. A calibration with a CT beam in the scout mode was performed and film strips were then exposed to single axial scans and to helical scans both in air and in phantoms. Two different types of flatbed scanners were used to read the film samples, a Microtek ScanMaker 9800XL scanner and an Epson Expression 10000 XL scanner, and the accuracy of the results were compared. For beam collimations above 10 mm differences between CTDI measured by film and CTDI measured by ionization chamber below 9% were found for the Epson scanner, with an average estimated error at 1 {sigma} level of 5%. For the Microtek scanner and for the same film samples, differences below 11% with an average error at 1 {sigma} level of 8% were founded. The 1 {sigma} uncertainty of the measured CTDI was provided by the method for each measurement, and it was shown that about the 95% of the differences between the CTDI measurements with radiochromic films and with the ionization chamber were below the estimated 2 {sigma} uncertainty, for both scanners. After an accurate calibration procedure and the consideration of the uncertainty associated with the measurement, Gafchromic XR-QA films can be used to evaluate the CTDI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geophysical signatures of soil AFFF contamination from spectral induced polarization and low field nuclear magnetic resonance methods

Few field methods are available for characterizing source zones contaminated with aqueous film forming foam (AFFF). Non-invasive geophysical characterization of AFFF source zone contamination in situ could assist with the delineation and characterization of these sites, allowing for more informed sampling regimes aimed at quantifying subsurface poly- and perfluoroalkyl substances (PFAS) contamination. In this study, we present initial results from the investigation of the sensitivity of two existing surface and borehole-deployable geophysical technologies, spectral induced polarization (SIP), and low field nuclear magnetic resonance (NMR), to soils impacted with AFFF. To investigate the sensitivity of these methods to AFFF-impacted soil, bench-scale column experiments were conducted on samples consisting of natural and synthetic soils and groundwater. While our findings do not show strong evidence of NMR sensitivity to soil PFAS contamination, we do find evidence that SIP has sufficient sensitivity to detect PFAS sorption to soils. This finding is based on evidence that AFFF constituents associated with the pore surface produce a measurable polarization response in both freshly contaminated synthetic soils and in soils historically impacted with AFFF.

54 ENVIRONMENTAL SCIENCES↗

A general approach to develop reduced order models for simulation of solid oxide fuel cell stacks

A reduced order modeling approach based on response surface techniques was developed for solid oxide fuel cell stacks. This approach creates a numerical model that can quickly compute desired performance variables of interest for a stack based on its input parameter set. The approach carefully samples the multidimensional design space based on the input parameter ranges, evaluates a detailed stack model at each of the sampled points, and performs regression for selected performance variables of interest to determine the responsive surfaces. After error analysis to ensure that sufficient accuracy is established for the response surfaces, they are then implemented in a calculator module for system-level studies. The benefit of this modeling approach is that it is sufficiently fast for integration with system modeling software and simulation of fuel cell-based power systems while still providing high fidelity information about the internal distributions of key variables. This paper describes the sampling, regression, sensitivity, error, and principal component analyses to identify the applicable methods for simulating a planar fuel cell stack.

Pan, Wenxiao↗

Bandgap tailoring of rutile TiO{sub 2}(110) via surface patterning with electron cyclotron resonance sputtering

Crystalline TiO{sub 2} nanodots have been formed on single crystal rutile TiO{sub 2}(110) surfaces via ion beam sputtering method by utilizing Ar ion beams from electron cyclotron resonance source. Nearly five times enhancement in absorbance of visible light, {approx}5 times increase in luminescence, and {approx}0.1 eV narrowing of bandgap are observed for nanodot-patterned surfaces, in the absence of any dopant material. Formation of crystalline rutile TiO{sub 2} nanodots and development of Ti interstitials on the TiO{sub 2}(110) surface, after ion beam sputtering, are responsible for these observations. Results suggest that these nanodot-patterned rutile TiO{sub 2} surfaces can become effective photocatalysts.

36 MATERIALS SCIENCE↗

A Method of Moments Wide Band Adaptive Rational Interpolation Method for High-Quality Factor Resonant Cavities

A new adaptive rational interpolation method is proposed to obtain the wideband frequency response of a resonant cavity simulated with the method of moments (MoM). This interpolation method uses both the Loewner matrix to construct a rational expression for the solution vector of MoM’s matrix system and an error estimator generated by the solution vectors and their derivatives. This error estimator is implemented in the adaptive procedure to gain a minimum set of frequencies and solution vectors required in the interpolation. The resulting set of frequencies and solution vectors is applied to interpolate other system variables, such as shielding effectiveness and input impedance. Here numerical results of a slotted cylindrical cavity supporting high-quality factor resonances are presented, showing that the new rational interpolation method is accurate and efficient in interpolating the complicated resonant response of the solution vector functions.

42 ENGINEERING↗

Genetic Signatures in the Envelope Glycoproteins of HIV-1 that Associate with Broadly Neutralizing Antibodies

A steady increase in knowledge of the molecular and antigenic structure of the gp120 and gp41 HIV-1 envelope glycoproteins (Env) is yielding important new insights for vaccine design, but it has been difficult to translate this information to an immunogen that elicits broadly neutralizing antibodies. To help bridge this gap, we used phylogenetically corrected statistical methods to identify amino acid signature patterns in Envs derived from people who have made potently neutralizing antibodies, with the hypothesis that these Envs may share common features that would be useful for incorporation in a vaccine immunogen. Before attempting this, essentially as a control, we explored the utility of our computational methods for defining signatures of complex neutralization phenotypes by analyzing Env sequences from 251 clonal viruses that were differentially sensitive to neutralization by the well-characterized gp120-specific monoclonal antibody, b12. We identified ten b12-neutralization signatures, including seven either in the b12-binding surface of gp120 or in the V2 region of gp120 that have been previously shown to impact b12 sensitivity. A simple algorithm based on the b12 signature pattern was predictive of b12 sensitivity/resistance in an additional blinded panel of 57 viruses. Upon obtaining these reassuring outcomes, we went on to apply these same computational methods to define signature patterns in Env from HIV-1 infected individuals who had potent, broadly neutralizing responses. We analyzed a checkerboard-style neutralization dataset with sera from 69 HIV-1-infected individuals tested against a panel of 25 different Envs. Distinct clusters of sera with high and low neutralization potencies were identified. Six signature positions in Env sequences obtained from the 69 samples were found to be strongly associated with either the high or low potency responses. Five sites were in the CD4-induced coreceptor binding site of gp120, suggesting an important role for this region in the elicitation of broadly neutralizing antibody responses against HIV-1.

59 BASIC BIOLOGICAL SCIENCES↗