Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Adaptive Sampling Algorithms for Probabilistic Risk Assessment of Nuclear Simulations

Nuclear simulations are often computationally expensive, time-consuming, and high-dimensional with respect to the number of input parameters. Thus exploring the space of all possible simulation outcomes is infeasible using finite computing resources. During simulation-based probabilistic risk analysis, it is important to discover the relationship between a potentially large number of input parameters and the output of a simulation using as few simulation trials as possible. This is a typical context for performing adaptive sampling where a few observations are obtained from the simulation, a surrogate model is built to represent the simulation space, and new samples are selected based on the model constructed. The surrogate model is then updated based on the simulation results of the sampled points. In this way, we attempt to gain the most information possible with a small number of carefully selected sampled points, limiting the number of expensive trials needed to understand features of the simulation space. We analyze the specific use case of identifying the limit surface, i.e., the boundaries in the simulation space between system failure and system success. In this study, we explore several techniques for adaptively sampling the parameter space in order to reconstruct the limit surface. We focus on several adaptive sampling schemes. First, we seek to learn a global model of the entire simulation space using prediction models or neighborhood graphs and extract the limit surface as an iso-surface of the global model. Second, we estimate the limit surface by sampling in the neighborhood of the current estimate based on topological segmentations obtained locally. Our techniques draw inspirations from topological structure known as the Morse-Smale complex. We highlight the advantages and disadvantages of using a global prediction model versus local topological view of the simulation space, comparing several different strategies for adaptive sampling in both contexts. One of the most interesting models we propose attempt to marry the two by obtaining a coarse global representation using prediction models, and a detailed local representation based on topology. Our methods are validated on several analytical test functions as well as a small nuclear simulation dataset modeled after a simplified Pressurized Water Reactor.

97 MATHEMATICS AND COMPUTING↗

Strain Measurement of Geological Samples Subjected to Triaxial Stresses Experienced During Hydraulic Loading

Understanding stress and strain relationships and having the ability to predict these quantities for known load conditions is crucial to all geomechanical and, in some instances, reservoir flow applications. The constitutive equations governing the deformation of geological materials are typically adequate for bulk or large scale deformation and stress analyses. However, these rules are generally less precise in their ability to make accurate predictions in physical processes where highly localized material heterogeneity exists or where the presence of geometric irregularities such as micro-cracks may be present. This is especially relevant to EGS where hydraulic fracture propagation models are needed to develop optimal reservoir creation strategies and where fracture permeability is significantly influenced by regional stress states and may affect reservoir operation strategies. The deficiencies of the models used to describe these physical processes are a practical reality necessitated by the manner in which rock properties must be obtained. Conventional rock mechanics tests subject samples to controlled load conditions and measure bulk deformations of the sample or more localized deformations only on exposed surfaces of the sample. They are currently unable to comprehensively map the deformation state within the sample. For processes such as fracture, however, the state of a particular region within the rock drives the overall failure behavior of the sample. The authors believe that possessing a means to measure strains within samples subjected to hydraulic fracture loading conditions will provide a useful tool for understanding the localized effects not captured by conventional techniques and may serve as a method for improving hydraulic fracture models. An ongoing effort at Oak Ridge National Laboratory endeavors to develop a neutron diffraction based strain measurement capability to interrogate the strain state of a geological sample, at arbitrary internal locations, subjected to a triaxial stress state. The basis of the method and initial results for simple load conditions were reported at last year s Stanford Geothermal Workshop. This work will report results from recent neutron diffraction strain measurement experiments in which marble samples were subjected to load conditions more representative of hydraulic fracturing operations within a pressure cell specially designed for the reported strain measurement technique.

An, Ke↗

Proteomic Sample Preparation Techniques: Towards Forensic Proteomic Applications

Proteomic sample preparation techniques rely on dynamic multi-step processes that are sample type dependent. Forensic proteomic applications comprise diverse sample types and therefore require numerous sample preparation workflows. A sample may need pre-treatment steps to solubilize proteins from a solid surface, for example - from clothing, from a swab, or off of a filter. A sample may need to be disrupted or homogenized to liberate proteins trapped in cells. Or a sample may need additional processing steps, such as organic extraction, to isolate proteins from small molecule contaminants which interfere with mass spectrometry (MS) measurements. Following these pre-treatment steps, proteins are reduced, denatured, alkylated, and enzymatically digested. The resulting peptide mixture can be desalted by solid phase extraction or fractionated prior to liquid chromatography MS-based proteomic characterization. Here we detail each step of this multi-stage sample type dependent processing.

Nicora, Carrie D.↗

Sampling synchronization through GPS signals

A method uses a distributed data acquisition system with multiple, physically unconnected, data acquisition units, that can be in wireless communication with a remote host, to timestamp measurement data with sub-microsecond time base accuracy of sampling clock relative to an absolute timeframe. A current absolute time is derived from messages received from a satellite radio beacon positioning system (GPS). Measurement data is sampled by each unit at a specified sampling rate. Using hardware logic, batches of sampled data are associated with corresponding timestamps representing the absolute time at which the data was sampled. Data and timestamps may be transmitted to the host. A time offset bias is compensated by comparing timestamps against a nominal time based on start time and nominal sampling rate. The sampling clock rate may be disciplined using time pulses from the GPS receiver. An initial start of data sampling by all units can also be synchronized.

Zhuge, James Q.↗

Colonie FUSRAP Site - Radioactive Dust Sampling of Residential and Commercial Properties - 16384

The Colonie Formerly Utilized Sites Remedial Action Program (FUSRAP) Site is located in the Town of Colonie, Albany County, New York. The U.S. Army Corps of Engineers (USACE) is currently addressing environmental contamination associated with the Site. The area surrounding the Site consists of residential and commercial properties, known as vicinity properties (VPs). Cleanup activities have been completed on many of these VPs under the FUSRAP to address depleted uranium contamination. Soil remediation activities have been substantially completed at the Colonie FUSRAP Site and its VPs under the FUSRAP. Recent studies performed by an independent party and under FUSRAP identified uranium within indoor dust in residencies and businesses in the immediate vicinity of the Site. The studies were limited to non-living areas such as basement window sills, garages, and attics. This paper discusses the indoor dust sampling and analysis, in support of the Remedial Investigation (RI) for the VPs, and presents sampling results. The indoor dust sample media presented many technical challenges regarding sampling design, data reduction, and data interpretation. In addition, because the RI is focused on numerous resident-owned, rental, and commercial properties, challenges where presented regarding right-of-entry to sample. Isotopic uranium ratios observed in the majority of the samples are indicative of the depleted uranium contaminant, even at trace levels. While the sampling and analysis methods were effective at identifying depleted uranium in the majority of the samples, preliminary property-specific risk assessment results do not indicate the presence of depleted uranium in sufficient concentrations to pose unacceptable risk to VP inhabitants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In Situ Sample Environment for Studying Corrosion of Nuclear Materials

Currently there is lack of fundamental understanding of kinetics and reaction mechanisms that occur at nuclear cladding-steam interface under extreme environments in the nuclear reactors. Such understanding is vital to design and develop advanced cladding materials for more economical and safer nuclear power. We present advanced in situ sample environment for probing solid-fluid interfaces using high resolution synchrotron methods for studying early stages of corrosion including development of oxide layer as corrosion proceeds. Both X-ray diffraction and X-ray fluorescence methods will be discussed to probe structural and elemental composition changes under steam environment using corrosion resistant cell at high temperatures. High intensity and brightness of synchrotron coupled with advanced in situ sample environment developed, presents an opportunity to understand the fundamental interfacial processes involved in degradation of materials. The in situ sample environment is optimized for XRD and XRF data collection at NSLS-II and will be available to all users through the proposal process. The in situ sample environment is built to study the interfacial interactions at temperatures and pressures up to 400 deg. C and 1500 psi. It consists of three main parts; the distribution manifold, the pressure vessel, and the reaction cell as shown in Figure 1. Water is allowed to heat up to 350 deg. C inside the pressure vessel to produce steam which is delivered to reaction cell using insulated delivery system. The cell design is adapted from J. Diefenbacher, et. al. However, it is modified for corrosion applications in steam environments. The reaction cell and sample holder are made from hastelloy due to its high corrosion resistance. The reaction cell is surrounded by copper heating block to control its temperature independently from the rest of the system. Lab view based platform is developed for remote monitoring of pressure and temperature. The sample environment was commissioned at 6-IDD beamline in the Advanced Photon Source, for grazing incidence XRD corrosion studies. Metallic Zr sample (200 μm thickness) was used due to its faster oxidation kinetics as compared to Zircaloy. Sample was exposed to steam at 350 deg. C and 50 psi for a total time of 64 hours. Results showed the presence of α-Zr as the dominant phase. After 32 hours of exposure to steam, three oxide peaks in the low diffraction angle side started to develop with time. These peaks are attributed to the growth of substoichiometric zirconium oxide phases (Zr{sub 3}O and Zr{sub 3}O{sub 1-x}). (authors)

36 MATERIALS SCIENCE↗

Sample mount for electron backscatter diffraction

A sample mount having a bottom surface, a front surface, and a second portion is disclosed. The first portion is perpendicular to the bottom surface. The second portion has an external surface and an internal surface and extends from the first portion to form a 70-degree angle relative to the bottom surface. The sample mount may also have a top surface, an opening extending through the second portion of the front surface, and a receiving area configured to receive a sample, wherein the top surface presents an unimpeded path between the sample and an SEM pole piece. The sample mount may include a spring-loaded handle configured to push the sample against the internal surface of the second portion of the front surface, wherein pushing the sample against the internal surface places the sample at the 70-degree angle relative to the bottom surface.

Wieliczka, David M.↗

Measurements of NaI(Tl) electron response: comparison of different samples

This paper measures the sample to sample variation in the light yield proportionality of NaI(Tl), and so explores whether this is an invariant characteristic of the material or whether it depends on the chemical and physical properties of the tested samples. We report on the electron response of nine crystals of NaI(Tl), differing in shape, volume, age, manufacturer and quality. The proportionality has been measured at the SLYNCI facility in the energy range between 3.5 to 460 keV. We observe that while samples produced by the same manufacturer at approximately the same time have virtually identical electron response curves, there are significant sample to sample variations among crystals produced by different manufacturers or at different times. In an effort to correlate changes in the electron response with details of the scintillation mechanism, we characterized other scintillation properties, including the gamma response and the x-ray excited emission spectra and decay times, for the nine crystals. While sample to sample differences in these crystals were observed, we have been unable to identify the underlying fundamental mechanisms that are responsible for these differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bounds on the sample complexity for private learning and private data release

Learning is a task that generalizes many of the analyses that are applied to collections of data, and in particular, collections of sensitive individual information. Hence, it is natural to ask what can be learned while preserving individual privacy. [Kasiviswanathan, Lee, Nissim, Raskhodnikova, and Smith; FOCS 2008] initiated such a discussion. They formalized the notion of private learning, as a combination of PAC learning and differential privacy, and investigated what concept classes can be learned privately. Somewhat surprisingly, they showed that, ignoring time complexity, every PAC learning task could be performed privately with polynomially many samples, and in many natural cases this could even be done in polynomial time. While these results seem to equate non-private and private learning, there is still a significant gap: the sample complexity of (non-private) PAC learning is crisply characterized in terms of the VC-dimension of the concept class, whereas this relationship is lost in the constructions of private learners, which exhibit, generally, a higher sample complexity. Looking into this gap, we examine several private learning tasks and give tight bounds on their sample complexity. In particular, we show strong separations between sample complexities of proper and improper private learners (such separation does not exist for non-private learners), and between sample complexities of efficient and inefficient proper private learners. Our results show that VC-dimension is not the right measure for characterizing the sample complexity of proper private learning. We also examine the task of private data release (as initiated by [Blum, Ligett, and Roth; STOC 2008]), and give new lower bounds on the sample complexity. Our results show that the logarithmic dependence on size of the instance space is essential for private data release.

99 GENERAL AND MISCELLANEOUS↗

Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor® 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R^2) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify self-absorption effects. The microscopy analysis compares different filter loadings and shows that smaller particle sizes (under 10 micron) can readily be seen on the more lightly loaded filters. At higher loadings, however, the particle size is harder to differentiate. This study provides data on actual stack emission samples showing a range of mass loading conditions and visual evidence of particle size and distribution and also presents the difficulties in quantifying self-absorption effects using actual samples.

air sampling↗

Enhanced Sampling and Analysis, Selection of Technology for Testing

The focus of this study includes the investigation of sampling technologies used in industry and their potential application to nuclear fuel processing. The goal is to identify innovative sampling methods using state of the art techniques that could evolve into the next generation sampling and analysis system for metallic elements. This report details the progress made in the first half of FY 2010 and includes a further consideration of the research focus and goals for this year. Our sampling options and focus for the next generation sampling method are presented along with the criteria used for choosing our path forward. We have decided to pursue the option of evaluating the feasibility of microcapillary based chips to remotely collect, transfer, track and supply microliters of sample solutions to analytical equipment in support of aqueous processes for used nuclear fuel cycles. Microchip vendors have been screened and a choice made for the development of a suitable microchip design followed by production of samples for evaluation by ANL, LANL, and INL on an independent basis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

An asixymmetric diffusion experiment for the determination of diffusion and sorption coefficients of rock samples

Diffusion anisotropy is a critical property in predicting migration of substances in sedimentary formations with very low permeability. The diffusion anisotropy of sedimentary rocks has been evaluated mainly from laboratory diffusion experiments, in which the directional diffusivities are separately estimated by through-diffusion experiments using different rock samples, or concurrently by in-diffusion experiments in which only the tracer profile in a rock block is measured. To estimate the diffusion anisotropy from a single rock sample, this study proposes an axisymmetric diffusion test, in which tracer diffuses between a cylindrical rock sample and a surrounding solution reservoir. The tracer diffusion between the sample and reservoir can be monitored from the reservoir tracer concentrations, and the tracer profile could also be obtained after dismantling the sample. Semi-analytical solutions are derived for tracer concentrations in both the reservoir and sample, accounting for an anisotropic diffusion tensor of rank two as well as the dilution effects from sampling and replacement of reservoir solution. The transient and steady-state analyses were examined experimentally and numerically for different experimental configurations, but without the need for tracer profiling. These experimental configurations are tested for in- and out-diffusion experiments using Koetoi and Wakkanai mudstones and Shirahama sandstone, and are scrutinized by a numerical approach to identify favorable conditions for parameter estimation. The analysis reveals the difficulty in estimating diffusion anisotropy; test configurations are proposed for enhanced identifiability of diffusion anisotropy. Moreover, it is demonstrated that the axisymmetric diffusion test is efficient in obtaining the sorption parameter from both steady-state and transient data, and in determining the effective diffusion coefficient if isotropic diffusion is assumed. Moreover, measuring reservoir concentrations in an axisymmetric diffusion experiment coupled with tracer profiling may be a promising approach to estimate of diffusion anisotropy of sedimentary rocks.

54 ENVIRONMENTAL SCIENCES↗

Sample preparation and biomass determination of SRF model mixture using cryogenic milling and the adapted balance method

Highlights: • An alternative sample comminution procedure for SRF is tested. • Proof of principle is shown on a SRF model mixture. • The biogenic content of the SRF is analyzed with the adapted balance method. • The novel method combines combustion analysis and a data reconciliation algorithm. • Factors for the variance of the analysis results are statistically quantified. - Abstract: The biogenic fraction of a simple solid recovered fuel (SRF) mixture (80 wt% printer paper/20 wt% high density polyethylene) is analyzed with the in-house developed adapted balance method (aBM). This fairly new approach is a combination of combustion elemental analysis (CHNS) and a data reconciliation algorithm based on successive linearisation for evaluation of the analysis results. This method shows a great potential as an alternative way to determine the biomass content in SRF. However, the employed analytical technique (CHNS elemental analysis) restricts the probed sample mass to low amounts in the range of a few hundred milligrams. This requires sample comminution to small grain sizes (<200 μm) to generate representative SRF specimen. This is not easily accomplished for certain material mixtures (e.g. SRF with rubber content) by conventional means of sample size reduction. This paper presents a proof of principle investigation of the sample preparation and analysis of an SRF model mixture with the use of cryogenic impact milling (final sample comminution) and the adapted balance method (determination of biomass content). The so derived sample preparation methodology (cutting mills and cryogenic impact milling) shows a better performance in accuracy and precision for the determination of the biomass content than one solely based on cutting mills. The results for the determination of the biogenic fraction are within 1–5% of the data obtained by the reference methods, selective dissolution method (SDM) and {sup 14}C-method ({sup 14}C-M)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Humidity-controlled preparation of frozen-hydrated biological samples for cryogenic coherent x-ray diffraction microscopy

Coherent x-ray diffraction microscopy (CXDM) has the potential to visualize the structures of micro- to sub-micrometer-sized biological particles, such as cells and organelles, at high resolution. Toward advancing structural studies on the functional states of such particles, here, we developed a system for the preparation of frozen-hydrated biological samples for cryogenic CXDM experiments. The system, which comprised a moist air generator, microscope, micro-injector mounted on a micromanipulator, custom-made sample preparation chamber, and flash-cooling device, allowed for the manipulation of sample particles in the relative humidity range of 20%-94%rh at 293 K to maintain their hydrated and functional states. Here, we report the details of the system and the operation procedure, including its application to the preparation of a frozen-hydrated chloroplast sample. Sample quality was evaluated through a cryogenic CXDM experiment conducted at BL29XUL of SPring-8. Taking the performance of the system and the quality of the sample, the system was suitable to prepare frozen-hydrated biological samples for cryogenic CXDM experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A portable molecular-sieve-based CO{sub 2} sampling system for radiocarbon measurements

We have developed a field-capable sampling system for the collection of CO{sub 2} samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO{sub 2} concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO{sub 2} selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO{sub 2} from chambers prior to the CO{sub 2} build-up phase and sampling. In addition, both the CO{sub 2} and H{sub 2}O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO{sub 2} and the determination of CO{sub 2} flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compression–tension cell with sample manipulator for in situ X‐ray nanotomography experiments

In situ X-ray nanotomography experiments where tensile or compressive force is applied on the sample require specialized equipment. A compression-tension device with fluid flow-through capability has been designed for X-ray nanotomography beamlines. The compression-tension cell is equipped with a triaxial stage for sample alignment and a high sensitivity loadcell for measurement of applied force. To handle the <100 µm samples used for X-ray nanotomography imaging and for loading samples on the compression-tension cell a sample manipulator has been built. The sample manipulator is capable of selecting a single <100 µm particle for nanotomography scanning while viewing multiple samples under an optical microscope. To test the functionality of these two devices an initial compression experiment involving two glass beads was performed. To demonstrate instrument stability two spherical glass beads were compressed from a no load condition until one of the beads fractured. Nanotomography data were collected at each step of increasing compressive force. The experimentally observed contact area of the spherical glass beads was compared with the theoretical estimate using the Hertz analysis. To demonstrate the fluid flow capability, two calcite grains were compressed against each other under a calcite saturated solution. Surface topological changes were observed for the stressed grain contact area.

X-ray tomography↗

TU-AB-BRC-11: Moving a GPU-OpenCL-Based Monte Carlo (MC) Dose Engine Towards Routine Clinical Use: Automatic Beam Commissioning and Efficient Source Sampling

Purpose: We have previously developed a GPU-OpenCL-based MC dose engine named goMC with built-in analytical linac beam model. To move goMC towards routine clinical use, we have developed an automatic beam-commissioning method, and an efficient source sampling strategy to facilitate dose calculations for real treatment plans. Methods: Our commissioning method is to automatically adjust the relative weights among the sub-sources, through an optimization process minimizing the discrepancies between calculated dose and measurements. Six models built for Varian Truebeam linac photon beams (6MV, 10MV, 15MV, 18MV, 6MVFFF, 10MVFFF) were commissioned using measurement data acquired at our institution. To facilitate dose calculations for real treatment plans, we employed inverse sampling method to efficiently incorporate MLC leaf-sequencing into source sampling. Specifically, instead of sampling source particles control-point by control-point and rejecting the particles blocked by MLC, we assigned a control-point index to each sampled source particle, according to MLC leaf-open duration of each control-point at the pixel where the particle intersects the iso-center plane. Results: Our auto-commissioning method decreased distance-to-agreement (DTA) of depth dose at build-up regions by 36.2% averagely, making it within 1mm. Lateral profiles were better matched for all beams, with biggest improvement found at 15MV for which root-mean-square difference was reduced from 1.44% to 0.50%. Maximum differences of output factors were reduced to less than 0.7% for all beams, with largest decrease being from1.70% to 0.37% found at 10FFF. Our new sampling strategy was tested on a Head&Neck VMAT patient case. Achieving clinically acceptable accuracy, the new strategy could reduce the required history number by a factor of ∼2.8 given a statistical uncertainty level and hence achieve a similar speed-up factor. Conclusion: Our studies have demonstrated the feasibility and effectiveness of our auto-commissioning approach and new efficient source sampling strategy, implying the potential of our GPU-based MC dose engine goMC for routine clinical use.

61 RADIATION PROTECTION AND DOSIMETRY↗