Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Determination of the mutual orientation between proton CSA tensors mediated through band-selective 1 H– 1 H recoupling under fast MAS

We report the mutual orientation of nuclear spin interaction tensors provides critical information on the conformation and arrangement of molecules in chemicals, materials, and biological systems at an atomic level. Proton is a ubiquitous and important element in a variety of substances, and its NMR is highly sensitive due to their virtually 100% natural abundance and large gyromagnetic ratio. Nevertheless, the measurement of mutual orientation between the 1 H CSA tensors has remained largely untouched in the past due to strong 1 H– 1 H homonuclear interactions in a dense network of protons. In this study, we have developed a proton-detected 3D 1 H CSA/ 1 H CSA/ 1 H CS correlation method that utilizes three techniques to manage homonuclear interactions, namely fast magic-angle spinning, windowless C-symmetry-based CSA recoupling (windowless-ROCSA), and a band-selective 1 H– 1 H polarization transfer. The asymmetric 1 H CSA/ 1 H CSA correlated powder patterns produced by the C-symmetry-based methods are highly sensitive to the sign and asymmetry parameter of the 1 H CSA, and the Euler angle β as compared to the symmetric pattern obtained by the existing γ-encoded R-symmetry-based CSA/CSA correlation methods and allows a larger spectral area for data fitting. These features are beneficial for determining the mutual orientation between the nuclear spin interaction tensors with improved accuracy.

1H CSA↗

Earthquake Arrival Association with Backprojection and Graph Theory

The association of seismic-wave arrivals with causative earthquakes becomes progressively more challenging as arrival detection methods become more sensitive, and particularly when earthquake rates are high. For instance, seismic waves arriving across a monitoring network from several sources may overlap in time, false arrivals may be detected, and some arrivals may be of unknown phase (e.g., P or S waves). We propose an automated method to associate arrivals with earthquake sources and obtain source locations applicable to such situations. To do so, we use a pattern detection metric based on the principle of back-projection to reveal candidate sources followed by graph-theory-based clustering and an integer linear optimization routine to associate arrivals with the minimum number of sources necessary to explain the data. We find that this method solves for all sources and phase assignments simultaneously, rather than in a sequential greedy procedure as is common in other association routines. We demonstrate our method on both synthetic and real data from the Integrated Plate Boundary Observatory Chile seismic network of northern Chile. For the synthetic tests, we report results for cases with varying complexity, including rates of 500 earthquakes/day and 500 false arrivals/station/day, for which we measure true positive detection accuracy of >95%. For the real data, we develop a new catalog between 1 January 2010 and 31 December 2017 containing 817,548 earthquakes, with detection rates on average 279 earthquakes/day and a magnitude-of-completion of M~1.8. A subset of detections are identified as sources related to quarry and industrial site activity, and we also detect thousands of foreshocks and aftershocks of the 1 April 2014 Mw 8.2 Iquique earthquake. During the highest rate of aftershock activity, >600 earthquakes/day are detected in the vicinity of the Iquique earthquake rupture zone.

58 GEOSCIENCES↗

Subaru adaptive-optics high-spatial-resolution infrared K- and L'-band imaging search for deeply buried dual AGNs in merging galaxies

We present the results of infrared K- (2.2 μm) and L'-band (3.8 μm) high-spatial-resolution (<0.''2) imaging observations of nearby gas- and dust-rich infrared luminous merging galaxies, assisted by the adaptive optics system on the Subaru 8.2 m telescope. We investigate the presence and frequency of red K – L' compact sources, which are sensitive indicators of active galactic nuclei (AGNs), including AGNs that are deeply buried in gas and dust. We observed 29 merging systems and confirmed at least one AGN in all but one system. However, luminous dual AGNs were detected in only four of the 29 systems (∼14%), despite our method's being sensitive to buried AGNs. For multiple nuclei sources, we compared the estimated AGN luminosities with supermassive black hole (SMBH) masses inferred from large-aperture K-band stellar emission photometry in individual nuclei. We found that mass accretion rates onto SMBHs are significantly different among multiple SMBHs, such that larger-mass SMBHs generally show higher mass accretion rates when normalized to SMBH mass. Our results suggest that non-synchronous mass accretion onto SMBHs in gas- and dust-rich infrared luminous merging galaxies hampers the observational detection of kiloparsec-scale multiple active SMBHs. This could explain the significantly smaller detection fraction of kiloparsec-scale dual AGNs when compared with the number expected from simple theoretical predictions. Our results also indicate that mass accretion onto SMBHs is dominated by local conditions, rather than by global galaxy properties, reinforcing the importance of observations to our understanding of how multiple SMBHs are activated and acquire mass in gas- and dust-rich merging galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

ENTROPY VS. ENERGY WAVEFORM PROCESSING: A COMPARISON ON THE HEAT EQUATION

Virtually all modern imaging devices function by collecting either electromagnetic or acoustic backscattered waves and using the energy carried by these waves to determine pixel values that build up what is basically an ”energy” picture. However, waves also carry ”informa- tion” that also may be used to compute the pixel values in an image. We have employed several measures of information, all of which are based on different forms of entropy. Numerous published studies have demonstrated the advantages of entropy, or “information imaging”, over conventional methods for materials characterization and medical imaging. Similar results also have been obtained with microwaves. The most sensitive information measure appears to be the joint entropy of the backscattered wave and a reference signal. A typical study is comprised of repeated acquisition of backscattered waves from a specimen that is changing slowing with acquisition time or location. The sensitivity of repeated experimental observations of such a slowly changing quantity may be defined as the mean variation (i.e., observed change) divided by mean variance (i.e., observed noise). We compute the sensitivity for joint entropy and signal energy measurements assuming that noise is Gaussian and using Wiener integration to compute the required mean values and variances. These can be written as solutions to the Heat equation, which permits estimation of their magnitudes. There always exists a reference such that joint entropy has larger variation and smaller variance than the corresponding quantities for signal energy, matching observations of several studies. Moreover, a general prescription for finding an “optimal” reference for the joint entropy emerges, which also has been validated in several studies.

Entropy↗

Sensitivity analysis of single-layer graphene resonators using atomic finite element method

Atomic finite element simulation is applied to study the natural frequency and sensitivity of a single-layer graphene-based resonator with CCCC, SSSS, CFCF, SFSF, and CFCF boundary conditions using the commercial code ANSYS. The fundamental frequencies of the graphene sheet are compared with the results of the previous finite element study. In addition, the sensitivity of the resonator is compared with the early work based on nonlocal elasticity theory. The results of the comparison are very good in all considered cases. The sensitivities of the resonator with different boundary conditions are obtained, and the order based on the boundary condition is CCCC > SSSS > CFCF > SFSF > CFFF. The highest sensitivity is obtained when the attached mass is located at the center of the resonator. This is useful for the design of a highly sensitive graphene-based mass sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying Microstructure Variability in Laser Powder Bed Fusion 316 L Stainless Steel Microstructures with Spatial Statistics

Here, we have explored data-driven methods for material microstructure quantification that improve sensitivity to microstructural changes compared to traditional approaches. The methods integrate multiple microstructural properties, including grain morphology, crystallographic orientation, and material phase information. The simpler method employs maps of the Euclidean distance transformation metric to evaluate the morphology of grain boundary networks. The more intensive approach employs generalized spherical harmonic mapping for crystallographic orientations, per-pixel phase information, and a variational auto-encoder for dimensionality reduction and results in a multidimensional clustering of by microstructure similarity. Applied to an experimental dataset of additively manufactured steel, both methods detected slight variations in samples produced under nominally identical processing conditions. Both methods were able to distinguish between samples from multiple (nominally identical) builds, while the generalized spherical harmonics-based method could additionally cluster data samples rotated at two orientations on the build plate. The improved sensitivity of the methods, demonstrated through comparison with traditional microstructure characterization techniques, offers advantages for microstructure quantification and comparisons in advanced manufacturing applications.

SS316L↗

Near-field spectroscopy of Dirac plasmons in Bi 2 Se 3 ribbon arrays

Plasmons supported in the massless electron surface states of topological insulators (TIs), known as Dirac plasmons, have great potential in next generation optoelectronics. However, their inherent confinement to the surface makes the investigation of Dirac plasmons challenging. Near-field techniques provide the ideal platform to directly probe Dirac plasmons due to the sensitivity to evanescent fields at the surface. Here, we demonstrate the use of aperture near-field spectroscopy for the investigation of localized terahertz (THz) Dirac plasmon resonances in Bi 2 Se 3 ribbon arrays with widths ranging from 10 to 40 µm. Unlike scattering THz near-field techniques, the aperture method is most sensitive to plasmons with the relevant lower-momenta corresponding to plasmon wavelengths on the scale of ~20 µm. The combination of THz time-domain spectroscopy and aperture near-field microscopy enables sampling of localized Dirac plasmons in the near-field zone in the 0.5–2.5 THz range. We map the plasmon dispersion, which reveals a coupled plasmon–phonon polariton interaction. The near-field spectra show a higher contrast of the upper polariton branch in comparison with far-field observations. The information revealed by aperture near-field spectroscopy could deepen our understanding of the behavior of Dirac plasmons, leading to the potential development of real-world TI devices.

42 ENGINEERING↗

Magnetism reflectometer study shows LiF layers improve efficiency in spin valve devices

New, more efficient materials for spin valves - a device used in magnetic sensors, random access memories, and hard disk drives - may be on the way based on research using the magnetism reflectometer at Oak Ridge National Laboratory (ORNL). Spin valve devices work by means of two or more conducting magnetic material layers that alternate their electrical resistance depending on the layers alignment. Giant magnetoresistance is a quantum mechanical effect first observed in thin film structures about 20 years ago. The effect is observed as a significant change in electrical resistance, depending on whether the magnetization of adjacent ferromagnetic layers is in a parallel or an antiparallel magnetic alignment. 'What we are doing here is developing new materials. The search for new materials suitable for injecting and transferring carriers with a preferential spin orientation is most important for the development of spintronics,' said Valeria Lauter, lead instrument scientist on the magnetism reflectometer at the Spallation Neutron Source (SNS), who collaborated on the experiment. The researchers discovered that the conductivity of such materials is improved when an organic polymer semiconductor layer is placed between the magnetic materials. Organic semiconductors are now the material of choice for future spin valve devices because they preserve spin coherence over longer times and distances than conventional semiconductors. While research into spin valves has been ongoing, research into organic semiconductors is recent. Previous research has shown that a 'conductivity mismatch' exists in spin valve systems in which ferromagnetic metal electrodes interface with such organic semiconductors as Alq3 ({pi}-conjugated molecule tris(8-hydroxy-quinoline) aluminium). This mismatch limits the efficient injection of the electrons from the electrodes at the interface with the semiconductor material. However, lithium fluoride (LiF), commonly used in light-emitting diodes, has been found to enhance the injection of electrons through the semiconductor. Researchers from the University of Alabama and ORNL used polarized neutrons at the magnetism reflectometer at SNS to investigate the electronic, magnetic, and structural properties of the electrodes in a novel system. In this system, the magnetic layers cobalt and Ni{sub 80}Fe{sub 20} are interfaced with spacer layers composed of the organic semiconductor Alq3. A coupling layer of LiF is inserted to separate the magnetized layers from the semiconductor. 'ALQ3 is an organic semiconductor material,' said Lauter. 'Normally in these systems a first magnetic layer is grown on a hard substrate so that one can get the controlled magnetic parameters. Then you grow the organic semiconductor layer, followed by another magnetic material layer, such as cobalt.' In addition to determining the effect of the LiF layers on the efficiency of the electron injection, the researchers wanted to determine the magnetic properties of the cobalt and Ni{sub 80}Fe{sub 20} as well as the interfacial properties: whether there is interdiffusion of cobalt through the LiF layer to the semiconductor, for example. The researchers used polarized neutrons at beam line 4A to probe the entire, layer-by-layer assembly of the system. 'Reflectometry with polarized neutrons is a perfect method to study thin magnetic films,' Lauter said. 'These thin films - if you put one on a substrate, you see it just like a mirror. However, this mirror has a very complicated internal multilayer structure. The neutrons look inside this complicated structure and characterize each and every interface. Due to the depth sensitivity of the method, we measure the structural and magnetic properties of each layer with the resolution of 0.5 nm. The neutron scattering results found that inserting LiF as a barrier significantly improves the quality of the interface, increasing the injection of electrons from the magnetic layer through the organic semiconductor in the spin valve and enhancing the overall properties of the system. In related work the magnetic properties of the cobalt film and the permalloy Ni{sub 80}Fe{sub 20} were characterized. Cobalt in particular needed attention, as it cannot be grown epitaxially (i.e., deposited) on an organic semiconductor film. Cobalt becomes polycrystalline or amorphous, and this affects its magnetic properties. The data from the first experiment showed that the cobalt layer in the system 'did not have typical magnetic properties,' Lauter said. 'The results showed that the cobalt had low magnetization. To improve the efficiency, the cobalt magnetization should be much higher. So this experiment helped us to improve the growth conditions and to get a cobalt layer with better magnetic properties.' In a subsequent experiment the researchers increased the magnetization of the cobalt, and a follow-up paper is in progress.

36 MATERIALS SCIENCE↗

Characterization of the local crystallinity via reflectance of very slow electrons

The reflectance of very slow electrons from solids and its electron energy dependence are shown as characteristic for the crystal system and its spatial orientation so they can serve, e.g., to fingerprinting the orientation of grains in polycrystals. Measurements on single crystals and polycrystals are validated via electron backscatter diffraction analyses. Sensitivity of the method to fine details of crystallinity is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The IAEA Coordinated Research Program on HTGR Reactor Physics, Thermal-hydraulics and Depletion Uncertainty Analysis: Description of the Benchmark Test Cases and Phases

The continued development of High Temperature Gas Cooled Reactors (HTGRs) requires verification of design and safety features with reliable high fidelity physics models and robust, efficient, and accurate codes. The uncertainties in the HTR analysis tools are today typically assessed with sensitivity analysis and then a few important input uncertainties (typically based on a PIRT process) are varied in the analysis to find a spread in the parameter of importance. However, one wish to apply a more fundamental approach to determine the predictive capability and accuracies of coupled neutronics/thermal-hydraulics and depletion simulations used for reactor design and safety assessment. Today there is a broader acceptance of the use of uncertainty analysis even in safety studies and it has been accepted by regulators in some cases to replace the traditional conservative analysis. Finally, there is also a renewed focus in supplying reliable covariance data (nuclear data uncertainties) that can then be used in uncertainty methods. Uncertainty and sensitivity studies are therefore becoming an essential component of any significant effort in data and simulation improvement. In order to address uncertainty in analysis and methods in the HTGR community the IAEA launched a Coordinated Research Project (CRP) on the HTGR Uncertainty Analysis in Modelling early in 2012. The project is built on the experience of the OECD/NEA Light Water Reactor (LWR) Uncertainty Analysis in Best-Estimate Modelling (UAM) benchmark activity, but focuses specifically on the peculiarities of HTGR designs and its simulation requirements. Two benchmark problems were defined with the prismatic type design represented by the MHTGR-350 design from General Atomics (GA) while a 250 MW modular pebble bed design, similar to the INET (China) and indirect-cycle PBMR (South Africa) designs are also included. In the paper more detail on the benchmark cases, the different specific phases and tasks and the latest status and plans are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Gamma-Method for Monitoring Ash Content of Coal

A brief analysis is given of the modern instrumental methods of monitoring the ash content of coal. Their particulars and drawbacks are examined. A neutron gamma-method of monitoring the ash content is proposed on the basis of integrated use of prompt γ-radiation accompanying inelastic scattering of fast neutrons and radiative capture of thermal neutrons by nuclei of the primary elements comprising the organic and mineral components of coal. The instrumental-methodological parameters of monitoring (sizes of the analyzed samples, energy intervals of the detected gamma radiation) making it possible to the increase the sensitivity of the method with respect to the ash content and to minimize the impact of the variability of the moisture content of coal on its material composition, are optimized. The method has been certified and recommended for representative monitoring of the quality of coarse coal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Placing Limits on the Higgs Production Cross Section at the Tevatron using the H → W + W - → ℓ + ℓ - Decay Channel

Limits on the Higgs production cross section at the Tevatron were placed using data with an integrated luminosity of 2.4 fb -1 from CDF. Limits over a Higgs mass range between 110 GeV and 200 GeV were determined, by calculating a limit at ten mass points distributed over this region. The analysis exclusively searches for Higgs produced by top-quark mediated gluon fusion and then decaying into two W bosons. Only leptonic decay channels of the W are considered, such that the final event signature consists of ee, eµ, or µµ with missing energy from undetected neutrinos. After an evaluation of alternative techniques, a neural net was selected as the best method for increasing the sensitivity of the measurement. The BFGS neural net training technique was selected as the most efficient method. A Bayesian Likelihood technique was used to place limits on the observed Higgs production cross section, and an expected limit was calculated by running 10,000 pseudo experiments. The 160 GeV mass point was the most most sensitive, achieving an expected limit 4.1 times the Standard Model prediction cross section at a 95% Confidence Level. Observed limits are within 1 σ of the expected limit below a mass point of ii 160 GeV. Above this, observed limits are higher than the expected limits, within 2 σ. The lowest observed limit was also at MH =160 GeV with a limit of 6.85 times the Standard Model prediction at a 95% Confidence Level. A new method for increasing the sensitivity of the measurement was proposed and investigated, but unused in the analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CHEMICAL MODELING OF YOUNG STELLAR OBJECTS. I. METHOD AND BENCHMARKS

Upcoming facilities such as the Herschel Space Observatory or Atacama Large Millimeter Array will deliver a wealth of molecular line observations of young stellar objects (YSOs). Based on line fluxes, chemical abundances can then be estimated by radiative transfer calculations. To derive physical properties from abundances, the chemical network needs to be modeled and fitted to the observations. This modeling process is however computationally exceedingly demanding, particularly if in addition to density and temperature, far-UV (FUV) irradiation, X-rays, and multi-dimensional geometry have to be considered. We develop a fast tool, suitable for various applications of chemical modeling in YSOs. A grid of the chemical composition of the gas having a density, temperature, FUV irradiation and X-ray flux is pre-calculated as a function of time. A specific interpolation approach is developed to reduce the database to a feasible size. Published models of AFGL 2591 are used to verify the accuracy of the method. A second benchmark test is carried out for FUV sensitive molecules. The novel method for chemical modeling is more than 250,000 times faster than direct modeling and agrees within a mean factor of 1.35. The tool is distributed for public use. Main applications are (1) fitting physical parameters to observed molecular line fluxes and (2) deriving chemical abundances for two- and three-dimensional models. They will be presented in two future publications of this series. In the course of developing the method, the chemical evolution is explored: we find that X-ray chemistry in envelopes of YSOs can be reproduced by means of an enhanced cosmic-ray ionization rate with deviations less than 25%, having the observational consequence that molecular tracers for X-rays are hard to distinguish from cosmic-ray ionization tracers. We provide the detailed prescription to implement this total ionization rate approach in any chemical model. We further find that the abundance of CH{sup +} in low-density gas with high ionization can be enhanced by the recombination of doubly ionized carbon (C{sup ++}) and suggest a new value for the initial abundance of the main sulfur carrier in the hot core.

79 ASTRONOMY AND ASTROPHYSICS↗

Learning and discovering multiple solutions using physics-informed neural networks with random initialization and deep ensemble

In this work we explore the capability of physics-informed neural networks (PINNs) to discover multiple solutions. Many real-world phenomena governed by nonlinear differential equations (DEs), such as fluid flow, exhibit multiple solutions under the same conditions, yet capturing this solution multiplicity remains a significant challenge. A key difficulty lies in providing appropriate initial conditions or guesses, as widely used time-marching schemes and Newton’s method are highly sensitive to these choices when solving complex computational problems. While machine learning models, particularly PINNs, have shown promise in solving DEs, their ability to capture multiple solutions remains underexplored. In this work, we propose a simple and practical approach using PINNs to learn and discover multiple solutions. We first demonstrate that PINNs, when combined with random initialization and deep ensemble method—originally developed for uncertainty quantification—can effectively uncover multiple solutions to nonlinear ordinary and partial DEs. Although training large ensembles of PINNs may appear computationally demanding, this can be done efficiently using vectorization techniques supported by modern deep learning frameworks, allowing many networks to be trained simultaneously. Our approach highlights the critical role of initialization in shaping solution diversity, addressing an often-overlooked aspect of machine learning for scientific computing. Furthermore, we propose utilizing PINN-generated solutions as initial conditions or initial guesses for conventional numerical solvers to enhance accuracy and efficiency in capturing multiple solutions. Extensive numerical experiments, including the Allen–Cahn equation and cavity flow, where our approach successfully identifies both stable and unstable solutions, validate the effectiveness of our method. These findings establish a general and efficient framework for addressing solution multiplicity in nonlinear DEs.

97 MATHEMATICS AND COMPUTING↗

Extreme Environment Silicon Carbide Hybrid Temperature & Pressure Optical Sensors

This final report contains the main results from a 3-year program to further investigate the merits of SiC-based hybrid sensor designs for extreme environment measurements in gas turbines. The study is divided in three parts. Part 1 studies the material properties of SiC such as temporal response, refractive index change with temperature, and material thermal response reversibility. Sensor data from a combustion rig-test using this SiC sensor technology is analyzed and a robust distributed sensor network design is proposed. Part 2 of the study focuses on introducing redundancy in the sensor signal processing to provide improved temperature measurement robustness. In this regard, two distinct measurement methods emerge. A first method uses laser wavelength sensitivity of the SiC refractive index behavior and a second method that engages the Black-Body (BB) radiation of the SiC package. Part 3 of the program investigates a new way to measure pressure via a distance measurement technique that applies to hot objects including corrosive fluids.

36 MATERIALS SCIENCE↗

In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study

Purpose: In gynecological radiotherapy with high dose rate (HDR){sup 192}Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. Methods: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron{sup 192}Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. Results: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. Conclusions: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE EFFECT OF LINE-OF-SIGHT TEMPERATURE VARIATION AND NOISE ON DUST CONTINUUM OBSERVATIONS

We investigate the effect of line-of-sight temperature variations and noise on two commonly used methods to determine dust properties from dust-continuum observations of dense cores. One method employs a direct fit to a modified blackbody spectral energy distribution (SED); the other involves a comparison of flux ratios to an analytical prediction. Fitting fluxes near the SED peak produces inaccurate temperature and dust spectral index estimates due to the line-of-sight temperature (and density) variations. Longer wavelength fluxes in the Rayleigh-Jeans part of the spectrum ({approx}> 600 {mu}m for typical cores) may more accurately recover the spectral index, but both methods are very sensitive to noise. The temperature estimate approaches the density-weighted temperature, or 'column temperature', of the source as short wavelength fluxes are excluded. An inverse temperature-spectral index correlation naturally results from SED fitting, due to the inaccurate isothermal assumption, as well as noise uncertainties. We show that above some 'threshold' temperature, the temperatures estimated through the flux ratio method can be highly inaccurate. In general, observations with widely separated wavelengths, and including shorter wavelengths, result in higher threshold temperatures; such observations thus allow for more accurate temperature estimates of sources with temperatures less than the threshold temperature. When only three fluxes are available, a constrained fit, where the spectral index is fixed, produces less scatter in the temperature estimate when compared to the estimate from the flux ratio method.

79 ASTRONOMY AND ASTROPHYSICS↗

Extended Forward Sensitivity Analysis for Uncertainty Quantification

Verification and validation (V&V) are playing more important roles to quantify uncertainties and realize high fidelity simulations in engineering system analyses, such as transients happened in a complex nuclear reactor system. Traditional V&V in the reactor system analysis focused more on the validation part or did not differentiate verification and validation. The traditional approach to uncertainty quantification is based on a 'black box' approach. The simulation tool is treated as an unknown signal generator, a distribution of inputs according to assumed probability density functions is sent in and the distribution of the outputs is measured and correlated back to the original input distribution. The 'black box' method mixes numerical errors with all other uncertainties. It is also not efficient to perform sensitivity analysis. Contrary to the 'black box' method, a more efficient sensitivity approach can take advantage of intimate knowledge of the simulation code. In these types of approaches equations for the propagation of uncertainty are constructed and the sensitivities are directly solved for as variables in the simulation. This paper presents the forward sensitivity analysis as a method to help uncertainty qualification. By including time step and potentially spatial step as special sensitivity parameters, the forward sensitivity method is extended as one method to quantify numerical errors. Note that by integrating local truncation errors over the whole system through the forward sensitivity analysis process, the generated time step and spatial step sensitivity information reflect global numerical errors. The discretization errors can be systematically compared against uncertainties due to other physical parameters. This extension makes the forward sensitivity method a much more powerful tool to help uncertainty qualification. By knowing the relative sensitivity of time and space steps with other interested physical parameters, the simulation is allowed to run at optimized time and space steps without affecting the confidence of the physical parameter sensitivity results. The time and space steps forward sensitivity analysis method can also replace the traditional time step and grid convergence study with much less computational cost. Several well defined benchmark problems with manufactured solutions are utilized to demonstrate the extended forward sensitivity analysis method. All the physical solutions, parameter sensitivity solutions, even the time step sensitivity in one case, have analytical forms, which allows the verification to be performed in the strictest sense.

97 MATHEMATICS AND COMPUTING↗