Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Data for Post-Access Report: Tidal Energy Resource Characterization and Model Validation via the Assessment of Cost-effective Spatially Distributed Current Measurements from microFloat Swarms

This project evaluated how high-resolution, spatially distributed field data can be used to refine and validate site-scale hydrodynamic simulations of tidal channels. Use of such spatially-distributed field observations or site-scale hydrodynamic simulations will be needed for producing accurate predictions of tidal energy production over larger arrays of tidal turbines. The data contained in this archive includes field observations of water velocity from a series of short surveys in Agate Pass taken on August 20th, 2020 using station-keeping ADCP (acoustic doppler current profiler) measurements, drifting downward-looking ADCPs, and microFloats, gathered by researchers at APL-UW under a previous project. It also includes high-resolution hydrodynamic model runs for the site during that time generated under TEAMER support. An explanatory file (.pdf format) describes the survey and field data structure. Processed data is stored in .mat format. Survey summary: start time, number of floats, water level. microFloat data: - Cleaned data for each float in survey, - Time series of position (lat., lon.), depth (relative to surface), and horizontal velocity (u, v) Drifting ADCP data: - Cleaned data for each drifting ADCP in survey - Time series of position (lat., lon.), sample depth (relative to surface), and observed water velocity (u,v,w) Stationary ADCP data: - Cleaned data for each station-keeping data set in survey - Time series of position (lat., lon.), sample depth (relative to surface), and observed water velocity (u,v,w) FVCOM (Finite Volume Coastal Ocean Model) model outputs: Water level and velocity, as well as derived variables (e.g., power density) from the final refined model simulations for the Agate Pass subdomain. Contained in NetCDF and ASCII files for the duration of August 18th and 20th 2020 field surveys. Additional scripts for processing the data and generating the figures in the report are included.

16 TIDAL AND WAVE POWER↗

An Acoustic Quench Detection Method for CICC Conductor Operating in Gas or Liquid

A method using micro-electro-mechanical system (MEMS) acoustic sensor technology to detect a quench and abnormal behavior of a superconductor is discussed. MEMS of microphone chips are installed along the coolant space of a superconducting conductor to monitor the coolant condition. By arranging the acoustic sensor array in a coolant flow channel, it is possible to quickly detect a change in the local condition of the coolant with precise spatial resolution. This method is useful for monitoring superconducting magnets and power cables, especially those made with a cable-in-conduit-conductor (CICC) configuration. The methodology described in this work will also be very useful for a high temperature superconducting (HTS) conductor, such as REBCO tape conductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Infrared Astronomical Satellite /IRAS/ and Shuttle Infrared Telescope Facility /SIRTF/ - Implications of scientific objectives on focal plane sensitivity requirements

The full potential of infrared astronomy can be realized only through observations made with space-based telescopes cooled to cryogenic temperatures. The paper outlines the scientific mission, system description, and focal plane requirements for two cryogenic telescopes: the Infrared Astronomical Satellite (IRAS) and the Shuttle Infrared Telescope Facility (SIRTF). IRAS, a 60-cm superfluid-helium-cooled telescope system, will perform a one-year 8-120-micron IR sky survey; it will provide results of high reliability and sensitivity, produce the first complete survey data for the 30-120-micron region, and fill in missing portions (spectrally and spatially) of previous surveys short of 30 microns; its focal plane assembly is being designed to approach background-limited performance with an array of 62 discrete detectors. The SIRTF design will allow detailed follow-up studies in the 1-1000-micron range with a 116-160-cm observatory-class instrument. The Shuttle sortie capability introduces the unique SIRTF concept of an easily refurbishable or replaceable focal plane instrument complement in an orbiting cryogenic telescope.

Mccreight, C. R.↗

Spectral consequences of photoreceptor sampling in the rhesus retina

Optical transforms were used to compute the power spectra of rhesus cones treated as arrays of image sampling points. Spectra were obtained for the central fovea, parafovea, periphery, and far periphery. All were consistent with a novel spatial sampling principle that introduces minimal noise for spatial frequencies below the Nyquist limits implied by local receptor densities, while frequencies above the nominal Nyquist limits are not converted into conspicuous moiree patterns, but instead are scattered into broadband noise. This sampling scheme allows the visual system to escape aliasing distortion despite a large mismatch between retinal image bandwidth and the Nyquist limits implied by extrafoveal cone densities.

Yellott, J. I., Jr.↗

Comparing restored HST and VLA imagery of R Aquarii

The maximum entropy method is applied to Hubble Space Telescope data taken of the R Aquarii binary system and its jet with the Faint Object Camera in order to restore an image in forbidden O III at 5007 A plagued by spherical aberration and detector saturation. These results are compared with 2-cm radio continuum imagery taken with the Very Large Array at the same limiting resolution of about 0.1 arcsec. The comparison suggests that shock excitation of the inner jet accounts for a spatial difference between the forbidden O III and radio continuum emission regions.

Hollis, J. M.↗

Radiometric infrared focal plane array imaging system for thermographic applications

This document describes research performed under the Radiometric Infrared Focal Plane Array Imaging System for Thermographic Applications contract. This research investigated the feasibility of using platinum silicide (PtSi) Schottky-barrier infrared focal plane arrays (IR FPAs) for NASA Langley's specific radiometric thermal imaging requirements. The initial goal of this design was to develop a high spatial resolution radiometer with an NETD of 1 percent of the temperature reading over the range of 0 to 250 C. The proposed camera design developed during this study and described in this report provides: (1) high spatial resolution (full-TV resolution); (2) high thermal dynamic range (0 to 250 C); (3) the ability to image rapid, large thermal transients utilizing electronic exposure control (commandable dynamic range of 2,500,000:1 with exposure control latency of 33 ms); (4) high uniformity (0.5 percent nonuniformity after correction); and (5) high thermal resolution (0.1 C at 25 C background and 0.5 C at 250 C background).

Esposito, B. J.↗

A multisource limb flare observed at multiple radio wavelengths

A flare with several radio sources occurred on the solar limb at 2155 UT on 1989 June 20. It was observed by the Very Large Array (VLA) and the Owens Valley Radio Observatory (OVRO). The VLA data consisted of images at 1.4 GHz, while OVRO provided spectral and spatial information over the range 1-15 GHz. We develop a new gyrosynchrotron model to analyze the sources observed at flare peak. This model differs from many previous ones in that it contains spatial variations of both the magnetic field and accelerated particle density. It uses a new gyrosynchrotron approximation which is valid at very low harmonics of the gyrofrequency. For the first time we find that the cause of the change of microwave source size with frequency in the event studied was due primarily to the spatial variation of the accelerated electron density. This is contrary to the common assumption that the variation in size is due to a nonuniform magnetic field. We also investigate a polarized source which brightened later in the flare, finding that it could have been due to plasma radiation or gyrosynchrotron emission.

Kucera, T. A.↗

Simulation fidelity of a virtual environment display

We assessed the degree to which a virtual environment system produced a faithful simulation of three-dimensional space by investigating the influence of a pitched optic array on the perception of gravity-referenced eye level (GREL). We compared the results with those obtained in a physical environment. In a within-subjects factorial design, 12 subjects indicated GREL while viewing virtual three-dimensional arrays at different static orientations. A physical array biased GREL more than did a geometrically identical virtual pitched array. However, addition of two sets of orthogonal parallel lines (a grid) to the virtual pitched array resulted in as large a bias as that obtained with the physical pitched array. The increased bias was caused by longitudinal, but not the transverse, components of the grid. We discuss implications of our results for spatial orientation models and for designs of virtual displays.

Nemire, Kenneth↗

Hybrid Synthetic/Real Aperture Antenna for High Resolution Microwave Imaging

Observations of key hydrological parameters at the spatial and temporal scales required in the post-2002 era face significant technological challenges. These measurements are based on relatively low frequency thermal microwave emission (at 1.4 GHz for soil moisture and salinity, 10 GHz and up for precipitation, and 19 and 37 GHz for snow). The long wavelengths at these frequencies coupled with the high spatial and radiometric resolutions required by the various global hydrology missions necessitate the use of very large apertures. Two-dimensional Synthetic Thinned Array Radiometry (2-D STAR), though promising in the long term, has many technical challenges in the areas of power, and sensitivity for very large apertures (i.e. greater than 300 wavelengths). This paper will discuss an alternative approach to the pure 2-D STAR, which uses an offset parabolic cylinder reflector fed by multiple elements to form a 1-D STAR. In essence a single STAR element is composed of a feedhorn and parabolic cylinder reflector. The elements are sparsely arrayed and thus can share a single reflector. This antenna would have no moving parts once deployed, have much higher sensitivity than a Y-shaped 2-D STAR of equivalent size, many fewer receivers than that 2-D STAR, and the reflector could be made of a thin film and lightweight deployment system for high packing density. The instrument using this approach would be a cross track push broom imager. An overview of the design parameters, potential deployment mechanisms and applications will be presented.

Doiron, Terence A.↗

NASA In Situ Data Needs to Support the Operational Calibration and Validation of Ocean Color Satellite Data Products

Calibrating ocean color satellite instruments and validating their data products requires temporal and spatial abundances of high quality in situ oceanographic data. The Consortium for Ocean Leadership Ocean Observing Initiative (OOl) is currently implementing a distributed array of in-water sensors that could provide a significant contribution to future ocean color activities. This workshop will scope the optimal way to use and possibly supplement the planned OOl infrastructure to maximize its utility and relevance for calibration and validation activities that support existing and planned NASA ocean color missions. Here, I present the current state of the art of NASA validation of ocean color data products, with attention to autonomous time-series (e.g., the AERONET -OC network of above-water radiometers), and outline NASA needs for data quality assurance metrics and adherence to community-vetted data collection protocols

Werdel, P. Jeremy↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV. The properties that make the SXS a powerful x-ray spectrometer also make it sensitive to the entire electromagnetic band. If characterized as a bolometer, it would have a noise equivalent power (NEP) of < 4x10(exp -18) W/(Hz)0.5. Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. These needs are addressed by a series of five thin-film radiation blocking filters that block long-wavelength radiation while minimizing x-ray attenuation. The SXS aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three warmer filters also were equipped with thermometers and heaters for decontamination.

microcalorimeter↗

Multi-Functional Distributed Fiber Sensors for Pipeline Monitoring and Methane Detections. Final Report

As an abundant and cheap fossil energy source, natural gas has become a significant energy supply to support the United States’ economy. However, the large-scale extraction and utilization of natural gas also impose significant challenges on methane leakage. This problem is exacerbated by aging gas utility delivery systems, including interstate high-pressure pipelines, storage, and transmission facilities. This project aims to develop a cost-effective fiber optical sensing method that can perform multi-parameter real-time measurements of natural gas pipelines across long interrogation distances up to 100 km with 1-meter spatial resolution. This sensing tool can evaluate overall pipeline efficiency and reduce methane emissions for mid-stream methane infrastructures. To accomplish this objective, research and development efforts funded by this project have resulted in the following accomplishments: This project successfully has developed new functional sensory polymer materials using Metal-Organic Frameworks (MOFs) that can be coated on optical fiber through the reel-to-reel coating process. Functional polymer-coated optical fibers can perform sensitive methane detection through evanescence wave interaction and strain-based measurements to achieve 1% detection sensitivities. The new sensors fibers support both distributed measurements and multiplexed fiber sensors array for multi-point measurements. This project developed and optimized a new multi-core optical fiber that supports simultaneous and distributed measurements of strain and temperatures with 1-meter spatial resolutions across up to 100-km interrogation distance. This new fiber, combined with sensory polymercoated fiber, could perform both distributed temperature and methane detections. This project developed a new artificial intelligence big data algorithm approach that can effectively analyze high-resolution data harnessed by distributed fiber sensors to protect natural gas pipelines against external threats and detect internal defects induced by corrosion. Working with our industry partner, this project developed new optical fibers that support fiber sensor fabrications through polymer coating after the fibers are drawn. These new fibers eliminate the need for direct sensor fabrication when the fiber is fabricated on a fiber draw tower, which drastically expands fiber sensors' applicability. This research project has significantly advanced the distributed fiber sensing technology. It will dramatically increase the applicability and adaptability of distributed fiber sensors for a wide array of applications in energy, sustainability, and environmental science, including structural health monitoring of natural gas pipelines, oil infrastructures, hydrogen facilities, and environmental monitoring of carbon storage sites, water supply systems, and others.

03 NATURAL GAS↗

Matched tandem etalon camera - MATEC - and its application to auroral observations

The matched tandem etalon camera employs a Fabry-Perot interferometer (FP) in the photographic mode for the spatial resolution over all angles up to 7 deg from normal. An interference filter and an appropriate field lens isolate a single order of 0.1 A resolution, which is recorded simultaneously at all angles in the field of view by array detection. Thus the resolution and luminosity of the MATEC camera are those of the FP. The MATEC pilot model has a ratio of free spectral range to linewidth of 400 and utilizes intensified photographic detection. In a system applied to auroral measurements the MATEC views a semiconical sky mirror to provide a simulatenous dimension of spatial resolution in the N-S meridian combined with the dimension of spectral resolution. Stellar features and cloud and ground reflections are more easily identified than by any scanning photometer.

Young, E. R.↗

A 5-18 micron array camera for high-background astronomical imaging

A new infrared array camera system using a Hughes/SBRC 58 x 62 pixel hybrid Si:Ga array detector has been successfully applied to high-background 5-18-micron astronomical imaging observations. The off-axis reflective optical system minimizes thermal background loading and produces diffraction-limited images with negligible spatial distortion. The noise equivalent flux density (NEFD) of the camera at 10 microns on the 3.0-m NASA/Infrared Telescope Facility with broadband interference filters and 0.26 arcsec pixel is NEFD = 0.01 Jy/sq rt min per pixel (1sigma), and it operates at a frame rate of 30 Hz with no compromise in observational efficiency. The electronic and optical design of the camera, its photometric characteristics, examples of observational results, and techniques for successful array imaging in a high- background astronomical application are discussed.

Gezari, Daniel Y.↗

A two-dimensional intensified photodiode array for imaging spectroscopy

The Johns Hopkins University is currently developing an instrument to fly aboard NASA's Space Shuttle as a Spartan payload in the late 1980s. This Spartan free flyer will obtain spatially resolved spectra of faint extended emission line objects in the wavelength range 750-1150 A at about 2-A resolution. The use of two-dimensional photon counting detectors will give simultaneous coverage of the 400 A spectral range and the 9 arc-minute spatial resolution along the spectrometer slit. The progress towards the flight detector is reported here with preliminary results from a laboratory breadboard detector, and a comparison with the one-dimensional detector developed for the Hopkins Ultraviolet Telescope. A hardware digital centroiding algorithm has been successfully implemented. The system is ultimately capable of 15-micron resolution in two dimensions at the image plane and can handle continuous counting rates of up to 8000 counts/s.

Tennyson, P. D.↗

2D microspatial distribution uniformity of photon detection efficiency and crosstalk probability of multi-pixel photon counters

Two-dimensional (2D) microspatial distribution uniformity of photon detection efficiency (PDE) and optical crosstalk probability P{sub ct} of multi-pixel photon counters (MPPCs) is studied. The experimental results show that the 2D spatial distribution of P{sub ct} is obviously uneven, i.e. P{sub ct} is larger at the corners and edges of a single pixel in MPPCs, which suggest a higher electrical field in the depletion region of the pixel at the corners and edges. The nonuniformity of the 2D spatial distribution of PDE also become evident when the size of the pixels of MPPCs is small, which signifies higher nonuniformity of the electric field distribution in MPPCs with small pixel size. A method is proposed for characterization of the 2D electrical field spatial distribution uniformity in a single pixel of MPPCs, which can be used for guiding the optimisation of the fabrication process of MPPCs and their properties. This promising method can naturally be extended to any Geiger avalanche photodiodes (G-APDs) and their arrays. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing Surface Plasmon Dynamics in Periodic Nanostructures through Ultrafast Electron Microscopy

Surface plasmon polaritons (SPPs) can be manipulated to localize and guide light in subwavelength distances, enabling them to find applications in a wide range of areas, from sensing to quantum computing. Among several methods of SPP excitation, periodic arrays of nano- and microstructures are of particular interest, as they enable engineering SPP properties through structural parameters. Here, in this study, using the photon-induced near-field electron microscopy (PINEM) technique, we investigated the mode formation, coupling, interference, and decay of SPPs in square and hexagonal arrays of circular nanoholes under both visible and near-infrared excitation. Polarization-resolved analysis revealed the key factors governing SPP localization and interference patterns, showing that the periodicity and symmetry of the array primarily determine the SPP interference patterns and their orientation, while pump polarization mainly modulates their intensity. Time-resolved PINEM measurements demonstrated the spatial dependence of the SPP temporal characteristics. In addition, cathodoluminescence (CL) spectroscopy was employed to examine the intrinsic plasmonic characteristics of the structure. Finite difference time domain (FDTD) simulations showed strong agreement with both PINEM and CL measurements on the spatial and spectral behavior of SPPs. Understanding the spatiotemporal dynamics of SPPs on nanostructures beyond the diffraction limit is crucial for optimizing plasmonic structures for advanced photonic and quantum technologies.

Plasmonics↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗