Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Material migration studies with an ITER first wall panel proxy on EAST

The ITER beryllium (Be) first wall (FW) panels are shaped to protect leading edges between neighbouring panels arising from assembly tolerances. This departure from a perfectly cylindrical surface automatically leads to magnetically shadowed regions where eroded Be can be re-deposited, together with co-deposition of tritium fuel. To provide a benchmark for a series of erosion/re-deposition simulation studies performed for the ITER FW panels, dedicated experiments have been performed on the EAST tokamak using a specially designed, instrumented test limiter acting as a proxy for the FW panel geometry. Carbon coated molybdenum plates forming the limiter front surface were exposed to the outer midplane boundary plasma of helium discharges using the new Material and Plasma Evaluation System (MAPES). Net erosion and deposition patterns are estimated using ion beam analysis to measure the carbon layer thickness variation across the surface after exposure. The highest erosion of about 0.8 µm is found near the midplane, where the surface is closest to the plasma separatrix. No net deposition above the measurement detection limit was found on the proxy wall element, even in shadowed regions. The measured 2D surface erosion distribution has been modelled with the 3D Monte Carlo code ERO, using the local plasma parameter measurements together with a diffusive transport assumption. In conclusion, excellent agreement between the experimentally observed net erosion and the modelled erosion profile has been obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controlled-Resonant Surface Tapping-Mode Scanning Probe Electrospray Ionization Mass Spectrometry Imaging

This paper reports on the advancement of a controlled-resonance surface tapping-mode single capillary liquid junction extraction/ESI emitter for mass spectrometry imaging. The basic instrumental setup and the general operation of the system were discussed and optimized performance metrics were presented. The ability to spot sample, lane scan and chemically image in an automated and controlled fashion were demonstrated. Rapid, automated spot sampling was demonstrated for a variety of compound types including the cationic dye basic blue 7, the oligosaccharide cellopentaose, and the protein equine heart cytochrome c. The system was used for lane scanning and chemical imaging of the cationic dye crystal violet in inked lines on glass and for lipid distributions in mouse brain thin tissue sections. Imaging of the lipids in mouse brain tissue under optimized conditions provided a spatial resolution of approximately 35 m based on the ability to distinguish between features observed both in the optical and mass spectral chemical images. The sampling spatial resolution of this system was comparable to the best resolution that has been reported for other types of atmospheric pressure liquid extraction-based surface sampling/ionization techniques used for mass spectrometry imaging.

Lorenz, Matthias↗

A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer

While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this study, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ~2.9 km/s. Finally, sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.

47 OTHER INSTRUMENTATION↗

Scanning Surface Potential Microscopy of Spore Adhesion on Surfaces

The adhesion of spores of Bacillus anthracis - the cause of anthrax and a likely biological threat - to solid surfaces is an important consideration in cleanup after an accidental or deliberate release. However, because of safety concerns, directly studying B. anthracis spores with advanced instrumentation is problematic. As a first step, we are examining the electrostatic potential of Bacillus thuringiensis (Bt), which is a closely related species that is often used as a simulant to study B. anthracis. Scanning surface potential microscopy (SSPM), also known as Kelvin probe force microscopy (KPFM), was used to investigate the influence of relative humidity (RH) on the surface electrostatic potential of Bt that had adhered to silica, mica, or gold substrates. AFM/SSPM side-by-side images were obtained separately in air, at various values of RH, after an aqueous droplet with spores was applied on each surface and allowed to dry before measurements. In the SSPM images, a negative potential on the surface of the spores was observed compared with that of the substrates. The surface potential decreased as the humidity increased. Spores were unable to adhere to a surface with an extremely negative potential, such as mica.

59 BASIC BIOLOGICAL SCIENCES↗

Note: A combined aerodynamic lens/ambient pressure x-ray photoelectron spectroscopy experiment for the on-stream investigation of aerosol surfaces

We discuss a new approach for the measurement of the surfaces of free aerosol particles with diameters from 50 to 1000 nm. Particles in this size range have significant influence on the heterogeneous chemistry in the atmosphere and affect human health. Interfacing an aerodynamic lens to an ambient pressure x-ray photoelectron spectrometer permits measurement of the surface chemical composition of unsupported aerosol particles in real time. We discuss the basic considerations for the design of such an instrument, its current limitations and potentials for improvement. Results from a proof-of-principle experiment on silicon oxide particles with average diameters of 270 nm are shown.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Point contact tunneling spectroscopy apparatus for large scale mapping of surface superconducting properties

In this paper, we describe the design and testing of a point contact tunneling spectroscopy device that can measure material surface superconducting properties (i.e., the superconducting gap Δ and the critical temperature T C ) and density of states over large surface areas with size up to mm 2 . The tip lateral (X,Y) motion, mounted on a (X,Y,Z) piezo-stage, was calibrated on a patterned substrate consisting of Nb lines sputtered on a gold film using both normal (Al) and superconducting (PbSn) tips at 1.5 K. The tip vertical (Z) motion control enables some adjustment of the tip-sample junction resistance that can be measured over 7 orders of magnitudes from a quasi-ohmic regime (few hundred Ω) to the tunnel regime (from tens of kΩ up to few GΩ). The low noise electronic and LabVIEW program interface are also presented. Finally, the point contact regime and the large-scale motion capabilities are of particular interest for mapping and testing the superconducting properties of macroscopic scale superconductor-based devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface rheology and interface stability.

We have developed a mature laboratory at Sandia to measure interfacial rheology, using a combination of home-built, commercially available, and customized commercial tools. An Interfacial Shear Rheometer (KSV ISR-400) was modified and the software improved to increase sensitivity and reliability. Another shear rheometer, a TA Instruments AR-G2, was equipped with a du Nouey ring, bicone geometry, and a double wall ring. These interfacial attachments were compared to each other and to the ISR. The best results with the AR-G2 were obtained with the du Nouey ring. A Micro-Interfacial Rheometer (MIR) was developed in house to obtain the much higher sensitivity given by a smaller probe. However, it was found to be difficult to apply this technique for highly elastic surfaces. Interfaces also exhibit dilatational rheology when the interface changes area, such as occurs when bubbles grow or shrink. To measure this rheological response we developed a Surface Dilatational Rheometer (SDR), in which changes in surface tension with surface area are measured during the oscillation of the volume of a pendant drop or bubble. All instruments were tested with various surfactant solutions to determine the limitations of each. In addition, foaming capability and foam stability were tested and compared with the rheology data. It was found that there was no clear correlation of surface rheology with foaming/defoaming with different types of surfactants, but, within a family of surfactants, rheology could predict the foam stability. Diffusion of surfactants to the interface and the behavior of polyelectrolytes were two subjects studied with the new equipment. Finally, surface rheological terms were added to a finite element Navier-Stokes solver and preliminary testing of the code completed. Recommendations for improved implementation were given. When completed we plan to use the computations to better interpret the experimental data and account for the effects of the underlying bulk fluid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies on the Use of Liquid Surface Passivation for Lifetime Measurements on Good-Quality Silicon Wafers

We evaluated several liquid passivants, viz. solutions of iodine ethanol (IE), quinhydrone methanol (QHM), and potassium cyanide (KCN), for measuring minority-carrier lifetime. Lifetime was measured by the WCT-100 (Sinton Instruments) and WT-2000 (Semilab). Our results show that both IE and QHM passivation are reliable mechanisms. We also find that the KCN solution is moderately passivating on oxidized surfaces, but is only minimally effective on bare Si surfaces. This paper presents details of our studies. In particular, the effect of illumination on IE-passivated surfaces and possible reasons for variations in lifetime measurement are discussed.

10 SYNTHETIC FUELS↗

X-ray Measurements of Fuel Spray Specific Surface Area and Sauter Mean Diameter for Cavitating and Non-Cavitating Diesel Sprays

Specific surface area measurements of diesel sprays were performed using ultra-small-angle x-ray scattering at the 9-ID beamline of the Advanced Photon Source at Argonne National Laboratory. Injector orifice type, rail pressure, and ambient pressure effects were explored. The targeted sprays were created by three different single-hole nozzles fitted with duplicate light-duty common rail diesel injector bodies. One of the nozzles has been designed to cavitate under typical diesel operating conditions, while the other two nozzles are its non-cavitating analogues with nominally identical geometries. Measurements were conducted in the near-nozzle region along the spray axis as well as across the width of the jet. These data provide information with regard to not only the rate of shear-driven atomization, but also the radial dispersion of the fuel droplets at each of the measured conditions. In addition, when coupled with complementary measurements of the projected density, the data quantify the Sauter mean diameter of the fuel droplets in the probe volume. Here, these specific surface area and Sauter mean diameter measurements can be used to inform computational models of spray breakup that rely on droplet information in the near-nozzle region, where optical diagnostics have proven challenging.

47 OTHER INSTRUMENTATION↗

Analysis of Spectral Lines in Large Databases of Synthetic Spectra for Massive Stars

In this paper, we describe a program that identifies in the optical spectrum the main parameters of a spectral line, namely the initial and final wavelengths, and the line depth. Moreover, using numerical calculations, it identifies and removes adjacent lines. Next, the program calculates the equivalent width and the FWHM. The software was tested in a sample of 300 lines in two databases of synthetic spectra generated by the CMFGEN and PoWR codes, and 300 lines in observed spectra from the IACOB database, showing a Gaussian distribution of relative errors, from which it is inferred that 80% of the measured lines have errors less than 17% and only 5% of the lines have errors greater than 26%. The program was also run on the entire database of 45,000 CMFGEN and 202 POWR synthetic spectra, generating a library of H i, He i, and He ii lines necessary to feed the FITspec code for the derivation of stellar parameters: effective temperature, surface gravity, and luminosity.

47 OTHER INSTRUMENTATION↗

Uncovering the Mysteries of Mars Habitability

Los Alamos scientists are uncovering clues about the habitability of ancient Mars using the ChemCam instrument that sits atop NASA’s Mars Curiosity rover. ChemCam has discovered 25 different elements on Mars—including manganese and boron—providing important information about conditions that could potentially have supported life on the Red Planet. Los Alamos is now developing a new instrument called SuperCam that will ride aboard the Mars 2020 rover and provide greater detail about the mineralogy and the presence of compounds related to the possibility of life on the surface of Mars.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared Thermometer Instrument Handbook

The infrared thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the brightness temperature of the scene in its field of view. The ground IRT (sometimes referred to as the upwelling instrument) lens has a wide field of view for measuring the radiating temperature of the ground surface. It measures in a narrow range of the infrared band, details of which can be found in Table 2. It provides data to the user averaged to 1-minute resolution. The infrared thermometer for sea-surface temperature (IRTSST) is a ship-based radiation pyrometer that provides measurements of the temperature of the sea surface. The upwelling infrared emission is determined with two different IRTs for over-ocean field campaigns and the data is at 1-second temporal resolution. The IRTs are mounted at heights varying between 2 and 42 m above the ground, oriented so the mounting platform and other human made objects are not in the field of view, and also to ensure that the ground and vegetation cover are representative of the local area. The Heitronics IRT is generally mounted inside a small enclosure, and the Apogee IRT is shielded by a cylindrical enclosure that is part of the design from the manufacturer.

47 OTHER INSTRUMENTATION↗

Far infrared thermal detectors for laser radiometry using a carbon nanotube array

We present a description of a 1.5 mm long, vertically aligned carbon nanotube array (VANTA) on a thermopile and separately on a pyroelectric detector. Three VANTA samples, having average lengths of 40 {mu}m, 150 {mu}m, and 1.5 mm were evaluated with respect to reflectance at a laser wavelength of 394 {mu}m(760 GHz), and we found that the reflectance decreases substantially with increasing tube length, ranging from 0.38 to 0.23 to 0.01, respectively. The responsivity of the thermopile by electrical heating (98.4 mA/W) was equal to that by optical heating (98.0 mA/W) within the uncertainty of the measurement. We analyzed the frequency response and temporal response and found a thermal decay period of 500 ms, which is consistent with the specific heat of comparable VANTAs in the literature. The extremely low (0.01) reflectance of the 1.5 mm VANTAs and the fact that the array is readily transferable to the detector's surface is, to our knowledge, unprecedented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct observation of spin-resolved full and empty electron states in ferromagnetic surfaces

We present a versatile apparatus for the study of ferromagnetic surfaces, which combines spin-polarized photoemission and inverse photoemission spectroscopies. Samples can be grown by molecular beam epitaxy and analyzed in situ. Spin-resolved photoemission spectroscopy analysis is done with a hemispherical electron analyzer coupled to a 25 kV-Mott detector. Inverse photoemission spectroscopy experiments are performed with GaAs crystals as spin-polarized electron sources and a UV bandpass photon detector. As an example, measurements on the oxygen passivated Fe(100)-p(1×1)O surface are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualization of Target Inspection data at the National Ignition Facility

As the National Ignition Facility continues its campaign to achieve ignition, new methods and tools will be required to measure the quality of the target capsules used to achieve this goal. Techniques have been developed to measure capsule surface features using a phase-shifting diffraction interferometer and Leica Microsystems confocal microscope. These instruments produce multi-gigabyte datasets which consist of tens to hundreds of files. Existing software can handle viewing a small subset of an entire dataset, but none can view a dataset in its entirety. Additionally, without an established mode of transport that keeps the target capsules properly aligned throughout the assembly process, a means of aligning the two dataset coordinate systems is needed. The goal of this project is to develop web based software utilizing WebGL which will provide high level overview visualization of an entire dataset, with the capability to retrieve finer details on demand, in addition to facilitating alignment of multiple datasets with one another based on common features that have been visually identified by users of the system.

42 ENGINEERING↗

Sensitivity enhancement of surface thermal lens technique with a short-wavelength probe beam: Experiment

Surface thermal lens is a highly sensitive photothermal technique to measure low absorption losses of various solid materials. In such applications, the sensitivity of surface thermal lens is a key parameter for measuring extremely low absorption. In this paper, we experimentally investigated the influence of probe beam wavelength on the sensitivity of surface thermal lens for measuring the low absorptance of optical laser components. Three probe lasers with wavelength 375 nm, 633 nm, and 1570 nm were used, respectively, to detect the surface thermal lens amplitude of a highly reflective coating sample excited by a cw modulated Gaussian beam at 1064 nm. The experimental results showed that the maximum amplitude of surface thermal lens signal obtained at corresponding optimized detection distance was inversely proportional to the wavelength of the probe beam, as predicted by previous theoretical model. The sensitivity of surface thermal lens could, therefore, be improved by detecting surface thermal lens signal with a short-wavelength probe beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of surface roughness on specular diagnostics in shocked experiments

Many shock experiments, whether impact, laser, or magnetically driven, use reflected optical light from shocked samples to diagnose their material properties. Specifically, optical velocimetry diagnostics, which do not require absolute power measurements, are regularly used to obtain equation-of-state information of materials. However, new diagnostics will be necessary to expand the realm of measured material properties, and many useful diagnostic techniques do require absolute measurements. Thus, it is important to understand what happens at the reflective surface of shock experiments, and the effect scattering has on the light collection of optical probes. To this end, we present results from experiments done to observe the behavior of a reflected beam from a specular coating on an optical window during shock impact. We find that the specular condition of the coating is adversely affected by the shock front, but this can be mitigated by minimizing roughness on the surface preceding the coating.

47 OTHER INSTRUMENTATION↗

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE↗