Search NASA⌕ Search

SEARCH · Search NASA

Results for “technical analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

April 2025 Semiannual Composite Salt Waste Processing Facility (SWPF) Decontaminated Salt Solution (DSS) Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from the Salt Waste Processing Facility is sampled semiannually for transfers to the Saltstone Production Facility. Salt solution is treated at the Saltstone Production Facility and disposed of in the Saltstone Disposal Facility. Per request of customer, X-TTR-Z-00027, Revision 0, one Saltstone Disposal Facility waste form was prepared at Savannah River National Laboratory using the Salt Waste Processing Facility Decontaminated Salt Solution and Z-area premix material for the April 2025 semiannual Toxicity Characteristic Leaching Procedure sample. The sample contained 60:40 (by weight) of slag and fly ash (referred to as the “Cement-Free grout sample”). Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request prepared by Savannah River Mission Completion. At 43 days cured, the Saltstone sample was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure. The April 2025 semiannual Cement-Free grout sample met the South Carolina Code of Regulations for Hazardous Waste Management Regulations 61-79.261.24 and 61-79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act metals and Underlying Hazardous Constituents, and met the Saltstone Production Facility Waste Acceptance Criteria that was in effect at the time of the sample collection at the Salt Waste Processing Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

October 2025 Semiannual Composite Salt Waste Processing Facility Decontaminated Salt Solution Toxicity Characteristic Leaching Procedure Results

The aqueous waste from the Salt Waste Processing Facility is sampled semiannually for transfers to the Saltstone Disposal Facility. Salt solution is treated at the Saltstone Production Facility and disposed of in the Saltstone Disposal Facility. Per request of customer, X-TTR-Z-00027, Revision 0, one Saltstone Processing Facility Decontaminated Salt Solution and Z area premix material for the October 2025 semiannual Toxicity Characteristic Leaching Procedure sample. The sample contained 60:40 (by weight) of slag and fly ash (referred to as the “Cement-Free grout sample”). Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request prepared by Savannah River Mission Completion. At 51 days cured, the Saltstone sample was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure. The October 2025 Semiannual Cement-Free grout sample met 61 79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act metals and Underlying Hazardous Constituents and met the Saltstone Production Facility Waste Acceptance Criteria that was in effect at the time of the sample collection at the Salt Waste Processing Facility.

Hsieh, Madison [Savannah River National Laboratory↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

47 OTHER INSTRUMENTATION↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

ADVANCED PROPULSION SYSTEMS↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

ADVANCED PROPULSION SYSTEMS↗

Household Energy Efficiency Analysis in San Jose, California

Many households in the City of San Jose, California, could save hundreds of dollars annually on their energy bills and reduce carbon emissions with energy efficiency retrofits and upgrades in their homes and apartments. As part of the U.S. Department of Energy's (DOE) Communities LEAP (Local Energy Action Program) pilot, the National Renewable Energy Laboratory (NREL) analyzed energy efficiency and electrification upgrades for 83,000 housing units in low-to-moderate-income census tracts experiencing disproportionately high energy burden in San Jose. The results in this fact sheet only pertain to the housing units included in the analysis.

Communities LEAP↗

Wet Waste Hydrothermal Liquefaction and Biocrude Upgrading to Hydrocarbon Fuels: 2022 State of Technology

Data from Pacific Northwest National Laboratory’s (PNNL) conversion hydrothermal liquefaction (HTL) program for wet waste was used to update the pathway techno-economic analysis (TEA) for the fiscal year 2022 State of Technology (2022 SOT). Figure S.1 shows the modeled minimum fuel selling price (MFSP) for the 2022 SOT, along with the previous years’ SOTs (Snowden-Swan et al. 2020, 2021, 2022). These costs are for a HTL plant scale of 110 dry ton/day sludge feed and a larger centralized upgrading plant scale of 38 million gallons/year biocrude feed, commensurate with the design case. All costs were updated to 2020 dollars. Corresponding cost breakdowns and technical parameters for each case are given in Appendix B. In previous years’ analyses options with and without ammonia (NH 3 ) stripping treatment of the HTL aqueous phase recycle stream were included in the analysis to account for cases with direct recycle of untreated HTL aqueous phase back to the wastewater treatment plant. In the FY21 SOT assessment however, system boundaries for the analysis were adjusted to reflect separate ownership/operatorship for the HTL plant and with that, nutrient surcharge fees associated with disposal of the aqueous phase wastewater to a municipal sewer system were incorporated to provide an improved accounting of true disposal costs for a standalone plant. With these changes, there is no significant cost difference between the case including ammonia removal and the case excluding ammonia removal and therefore the “no NH3 removal” options will not be included in the 2022 and future SOTs.

09 BIOMASS FUELS↗

Bridging Control and Deployment: A Cross-Layer Analysis of Scalable Building Cluster Control

Building cluster control has emerged as a promising approach for enabling flexible and coordinated operation of distributed building systems, yet its transition from pilot demonstrations to routine grid-interactive operation remains limited. This paper argues that this gap cannot be explained by control algorithms alone. Instead, it arises from interacting barriers in communication infrastructure, data and semantic interoperability, uncertainty management, stakeholder participation, market design, and policy support. Accordingly, the paper reviews both technical and non-technical barriers to building cluster control. Technical challenges include heterogeneous devices and protocols, communication latency and reliability, distributed decision-making, and uncertainty propagation across aggregated loads. Non-technical barriers include user participation, stakeholder coordination, incentive allocation, and data governance. Existing solution approaches are synthesized, including semantic interoperability frameworks, edge and hierarchical communication architectures, distributed and transactive control strategies, uncertainty-aware optimization, policy mechanisms, and market reforms. Based on this analysis, two research directions are identified: testing infrastructures that can evaluate control performance under realistic multi-building conditions, and abstraction methods that allow building clusters to interact with other energy sectors through standardized flexibility representations. Overall, the paper provides a structured review of how building cluster control can move from isolated demonstrations toward reproducible, market-compatible, and grid-relevant implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Analysis for GTI's Compact Hydrogen Generator

A technoeconomic analysis of the compact hydrogen generator compared to a traditional steam methane reformer (SMR) was performed for both processes with and without carbon capture. The project goal for the technoeconomic analysis was to demonstrate a minimum of 20% lower CAPEX and 15% lower levelized cost of hydrogen compared to SMR with and without carbon capture. GTI obtained baseline capital and costs for the SMR with and without and methodology to calculate the levelized cost of hydrogen from an IEAGHG Technical Report: 2017-02 Techno-Economic Evaluation of SMR Based Standalone (Merchant) Hydrogen Plant with CCS. This methodology was then applied to GTI’s compact hydrogen generator using direct material costs previously obtained from a reputable engineering procurement and construction company, CB&I Howe-Baker. The analysis was performed for plants producing 90MMSCFD (million standard cubic feed per day) of hydrogen. Direct material costs were converted to total installed costs and total capital requirements using the same multiplying factors for both processes. We have found that the direct materials cost of the compact hydrogen generator is less than half the direct materials cost required for SMR without capture, and about one quarter the direct materials cost of SMR with carbon capture. This low materials cost translates into a significant CAPEX savings and lower levelized cost of hydrogen that exceed the goals of the techno-economic assessment. We have found that the CHG has a 43% lower installed cost and capital requirement compared to SMR without capture, that results in a levelized cost of hydrogen that is 19% lower than SMR. When 90% CO2 capture is added to the plants, the advantages is even better. The CHG has a 51% lower installed and capital requirement compared to SMR with capture, resulting in a 28% lower levelized cost of hydrogen. A sensitivity analysis was performed and showed natural gas feedstock cost and discount rate to be the main contributors to hydrogen price sensitivity. Given these significant cost advantages, GTI is encouraged to continue to develop the technology and market the economic advantages as well as the efficiency gains and ability to inherently capture CO2.

08 HYDROGEN↗

Capacity Density Considerations for Floating Offshore Wind Farms in Ultradeep Waters

Capacity density describes the concentration of wind energy development in an area and is often specified in terms of megawatts-per-square-kilometer (MW/km2). Understanding capacity density trends in wind energy projects helps to inform both energy system and spatial planning efforts. Borrman et al. (2018) and Mulas Hernando et al. (2023) analyze capacity density trends for fixed-bottom offshore wind farms in Europe and the United States, respectively, and Cooperman et al. (2022) explores how floating offshore wind mooring technology choices may impact wind plant layout through setbacks from lease area boundaries in waters up to 1,300 m deep. Technical challenges facing floating offshore wind development in ultradeep waters (beyond 1,300 m) could impact achievable capacity densities, with potential implications to marine spatial planning and project economics. When compared to fixed-bottom commercial-scale wind farms, mooring system footprints from floating offshore wind systems can constrain capacity density in some circumstances. In this study, we conduct an initial investigation of how taut mooring configurations may constrain floating offshore wind turbine placement and estimate capacity density for representative floating wind plants in generic lease areas. In addition, we explore floating wind plant capacity density drivers in ultradeep waters by characterizing area utilization for a range of lease area characteristics. This analysis highlights the primary challenges that floating offshore wind systems may encounter in achieving capacity densities comparable to commercial-scale fixed-bottom projects at ultradeep water depths, from a technical standpoint.

capacity density↗

Analysis of Defense Waste Processing Facility Sample: Off-Gas Condensate Tank Sample Batch 27862

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (now Savannah River Mission Completion (SRMC)), through a Technical Task Request (X-TTR-H-00107), to characterize the “as-received” Off-Gas Condensate Tank (OGCT) Sample identified as sample batch 27862, which was delivered to SRNL Shielded Cells on April 30, 2021. This OGCT report is the third of three sample characterization reports dealing with this Defense Waste Processing Facility (DWPF) Recycle Diversion Project. The other two recycling stream characterization reports are the Recycle Collection Tank (RCT) and the Slurry Mix Evaporator Condensate Tank (SMECT) sample report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NO$\nu$A Far Detector $\nu_e$ Sideband Study Technical Note

Till now the NO$\nu$A experiment has used the Far Detector (FD) electron neutrino (anti-neutrino) events in the energy range 1 < $E_ν$ < 4 GeV in 3-favor neutrino oscillation analysis, to constraint the neutrino oscillation parameters. In this study, we have used the high-energy neutrino (sideband) sample with 4 < $E_ν$ < 12 GeV, dominated heavily by the beam electron neutrino/anti-neutrino background events to constrain the neutrino oscillation parameters. This was done to figure out if an additional power can be obtained in constraining the oscillation parameters by adding this sample to the analysis. This technote discusses the modifications done in the existing framework to add the sideband sample to the standard FD $\nu_e$ predictions and its impact on the neutrino oscillation parameters sensitivity of the NO$\nu$A experiment. Results from the statistics only study and the study including all the existing systematic shifts are reported separately.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DAISY: A Rapid Approach to Evaluating Marine Energy Converter Sound (Final Technical Report)

This project’s objective was to improve the quality of acoustic information about marine energy converters that could be collected from groups of drifting hydrophones, while reducing the costs of deployment and data analysis. This was achieved through technology development addressing four focus areas: (1) minimizing flow-noise and self-noise, (2) integrating metadata streams into a single data acquisition system, (3) developing post-processing routines to facilitate rapid data review, and (4) enabling objective identification of marine energy converter sound against a backdrop of ambient noise using time-delay-of-arrival localization.

16 TIDAL AND WAVE POWER↗

Transformer Health Monitoring Using Dissolved Gas Analysis

As integral components of any power plant, transformers supply the generated electricity to the grid. However, a transformer’s cellulose-based paper insulation and the mineral oil in which it is immersed break down over time under standard operating conditions—or more rapidly due to potential faults within the system. As the transformer’s mineral oil breaks down, gases are released that can be measured and monitored. This technical brief exhibits a collection of diagnostic and prognostic techniques that utilities can adopt in lieu of labor-intensive periodic preventive maintenance routines. Furthermore, prognostic models have been incorporated using the latest version of the Institute of Electrical and Electronics Engineers (IEEE) standard (IEEE, 2019) for dissolved gas analysis (DGA), thus expanding it to include estimation of the time to maintenance. Overall, four different methodologies are explained, each of which aids in determining a transformer’s state of health. These methodologies include the Chendong model, the IEEE thermal life consumption model (IEEE, 2012), a diagnostic model for DGA, and a prognostic model for DGA that uses an autoregressive integrated moving average (ARIMA) model. An additional improvement for estimating missing system parameters by using monitoring data (i.e., a tool for parameter estimation utilizing Powell’s method) is presented, enabling the IEEE thermal life consumption model to benefit not only the collaborating power plant, but also the power industry at large.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adapting the Technology Performance Level Integrated Assessment Framework to Low-TRL Technologies Within the Carbon Capture, Utilization, and Storage Industry, Part I

With the urgent need to mitigate climate change and rising global temperatures, technological solutions that reduce atmospheric CO 2 are an increasingly important part of the global solution. As a result, the nascent carbon capture, utilization, and storage (CCUS) industry is rapidly growing with a plethora of new technologies in many different sectors. There is a need to holistically evaluate these new technologies in a standardized and consistent manner to determine which technologies will be the most successful and competitive in the global marketplace to achieve decarbonization targets. Life cycle assessment (LCA) and techno-economic assessment (TEA) have been employed as rigorous methodologies for quantitatively measuring a technology's environmental impacts and techno-economic performance, respectively. However, these metrics evaluate a technology's performance in only three dimensions and do not directly incorporate stakeholder needs and values. In addition, technology developers frequently encounter trade-offs during design that increase one metric at the expense of the other. The technology performance level (TPL) combined indicator provides a comprehensive and holistic assessment of an emerging technology's potential, which is described by its techno-economic performance, environmental impacts, social impacts, safety considerations, market/deployability opportunities, use integration impacts, and general risks. TPL incorporates TEA and LCA outputs and quantifies the trade-offs between them directly using stakeholder feedback and requirements. In this article, the TPL methodology is being adapted from the marine energy domain to the CCUS domain. Adapted metrics and definitions, a stakeholder analysis, and a detailed foundation-based application of the systems engineering approach to CCUS are presented. The TPL assessment framework is couched within the internationally standardized LCA framework to improve technical rigor and acceptance. It is demonstrated how stakeholder needs and values can be directly incorporated, how LCA and TEA metrics can be balanced, and how other dimensions (listed earlier) can be integrated into a single metric that measures a technology's potential.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nuclear Safety [Vol. 32, No. 4, October-December 1991]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 477 Report on the International Symposium on the Use of Probabilistic Safety Assessment for Operational Safety—PSA '91, S. Chakraborty and M. Khatib-Rahbar; 488 Good Relationships Are Pivotal in Nuclear Data Bases, A. S. Heger and B. V. Koen; 494 Technical Note: The Interagency Nuclear Safety Review Panel's Evaluation of the Ulysses Space Mission, J. A. Sholtis, Jr., D. A. Huff, L. B. Gray, N. P. Klug, and R. O. Winchester; ACCIDENT ANALYSIS: 502 The Severe Accident Analysis Program for the Savannah River Nuclear Production Reactors, M. L. Hyder; CONTROL AND INSTRUMENTATION: 511 A Framework for Selecting Suitable Control Technologies for Nuclear Power Plant Systems, R. A. Kisner; DESIGN FEATURES: 521 Containments for Gas-Cooled Power Reactors History and Status, P.W. Williams; ENVIRONMENTAL EFFECTS: 537 Indoor Radon: A Natural Risk, N. H. Harley and J.H. Harley; On the Importance of the Atmospheric Parameters in the Fission Products Distribution of a Severe Reactor Accident, M. C. Barla and A. R. Bayulken; Book Review: Health Effects of Exposure to Low Levels of Ionizing Radiation BEIR V, C. R. Richmond; WASTE AND SPENT FUEL MANAGEMENT: 555 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver OPERATING EXPERIENCES: 567 Effects of Component Aging on the Westhinghouse Control Rod Drive System, K. Sullivan and W. Gunther; 577 Reactor Shutdown Experience, Compiled by J. W. Cletcher, 580 Selected Safety-Related Events, Compiled by G. A. Murphy; 582 Operating U 8 Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver, RECENT DEVELOPMENTS: 596 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 610 Reports, Standards, and Safety Guides, D. S. Queener; 614 Proposed Rule Changes as of June 30, 1991; ANNOUNCEMENTS: 520 Workshop on PC PRAISE: A Probabilistic Fracture Mechanics Personal Computer Code for Nuclear Power Plant Piping Reliability Assessment; 536 Fifth Workshop on Nuclear Power Plant Containment Integrity; 624 New OECD "International Information System on Occupational Exposure (ISOE)"; 625 Harvard School of Public Health Announces Short Courses; 625 Eighth Power Plant Dynamics, Control and Testing Symposium; 626 Second Training Course on Off-Site Emergency Planning and Response for Nuclear Accidents; 618 The Authors; 622 Reviewers of Nuclear Safety, Vol 32.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Syracuse University Industrial Assessment Center (Final Report)

Syracuse University Industrial Assessment Center (SU-IAC) project is focused on the two primary objectives: (i) educate undergraduate and graduate students in engineering and associated disciplines on the concepts of energy sustainability and to provide hands-on training by performing energy assessment at industrial facilities to become future energy efficiency experts, and (ii) offer energy assessments to small and mid-sized manufacturing companies in SU-IAC 2 the greater New York State region, perform analytical engineering work in support of assessment recommendations, and to report the results of those analyses to the client companies, to DOE, and to Field office personnel Through this project period, SU-IAC successfully trained 77 engineering students who were undergraduate or graduate students at Syracuse University College of Engineering, or at SU- IAC’s satellite center at Clarkson University. Each of these students received comprehensive ‘in-class’ technical training, safety training, and hands-on field training. The students performed various tasks related to energy assessment at the manufacturing facilities, including billing analysis, energy use reduction recommendations, and report preparation. Through this project period, a total of 34 students have completed all requirements of the SU-IAC program and have received the US DoE Certificate on Energy Efficiency, with the remaining students continuing at various stages of field work or training. During this project period, due to Covid-related measures in New York State, Syracuse University campus and most of the manufacturing facilities were completely closed or were under severe restrictions for access, for an extended period from March 2020 through April 2021. The closures affected our project execution, with the project Sponsor offering structured relief to carry-out a modified project during the affected budget periods. During this project period, SU-IAC student teams, led by its Director, completed a total of 77 energy assessments at small- and medium-scale manufacturing facilities located in New York State. For these facilities, SU-IAC prepared and presented details for 569 assessment recommendations (ARs). The facilities implemented a total of 258 of these ARs, realizing annual average energy savings in the range of $\$ $3,300 to $\$ $55,000 per facility. Cumulatively, these facilities have reduced their “first year after implementation” energy use by a total of 4.37 million kwh, and fuel use by a total of 27.7 billion BTU. SU-IAC project has successfully met the two primary objectives (and the associated sub objectives) and helped the manufacturing facilities in New York State achieve quantitative energy use reductions as a result of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Codes and Ordinances for Clean Energy: Highland Park Pathways to Power [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "A" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development.

24 POWER TRANSMISSION AND DISTRIBUTION↗