Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Development of a Time-Height Profile Assimilation Technique for Large-Eddy Simulation

Mesoscale-to-microscale coupling (MMC) aims to address the limited scope of traditional large-eddy simulations by driving the microscale flow with information concerning large-scale weather patterns provided by mesoscale models. We present a new offline MMC technique for horizontally homogeneous microscale flow conditions, in which internal forcing terms are computed based on mesoscale time–height profiles of mean-flow quantities. The advantage of such an approach is that it can be used to drive a microscale simulation with either mesoscale or observational data, and that it does not rely on specific terms in the mesoscale budget equations, which are typically not part of the default output of a mesoscale solver. The performance of the proposed profile assimilation technique is assessed based on the simulation of a typical diurnal cycle over the Scaled Wind Farm Technology site in west Texas. Results indicate that simple data assimilation techniques lead to unphysically high levels of shear and turbulence caused by the algorithm’s inability to cope with inaccuracies in the mesoscale time–height profiles. Modifying the algorithm to account for vertical coherence in the mesoscale source terms gives the microscale solver a greater ability to correct the provided mesoscale time–height profiles, leading to improved predictions of shear and turbulence statistics. The resulting turbulence statistics are in good agreement with meteorological tower observations and simulation results obtained with state-of-the-art coupling techniques using mesoscale budget components.

data assimilation↗

Application of Multivariate Curve Resolution–Alternate Least Square Technique on Extracting Pure Spectral Components from Multiple Emitting Systems: a Case Study

Multiple emitting components in a fluorophoric system often produce complicated emission spectra. Extracting the individual spectral information from the composite spectra is important in order to comprehend the photophysical processes occurring in the multifluorophoric systems. Although the combination of Principal Component Analysis and Multivariate Curve Resolution-Alternate Least Square (PCA/MCR-ALS) technique is a well-known approach for curve deconvolution, its applicability in the spectral deconvolution of vibronically and electronically mixed up emitting systems as well as systems merged up with multiple electronic bands without a priori knowledge of the individual emitting species, is not properly studied. The present work highlights the strength of PCA/MCR-ALS in retrieving pure spectral information from the set of complex spectra arising out of the regular variation of causative factors that result in the variation of spectral composition. The retrieval of the emission bands utilizing the PCA/MCR-ALS technique has been made without having a priori information of the emitting species present in the multifluorophoric systems and the resolved spectra correspond well with the fluorescence spectra of the individual chemical species. The common curve fitting methods such as Gaussian and Lorentzian techniques have been found to be unsuccessful in providing meaningful photophysical information through the retrieved spectra. A comparative study of the curve fitting techniques MCR-ALS, Gaussian and Lorentzian in a set of complicated emission spectra of (i) pyrene and its excimer, (ii) pyrene and its excimer in presence of benzo[a]pyrene, and (iii) fisetin in bile salt medium is presented herein in details.

74 ATOMIC AND MOLECULAR PHYSICS↗

Surgical implantation techniques for electronic tags in fish

Intracoelomic implantation of transmitters into fish requires making a surgical incision, incision closure, and other surgery related techniques; however, the tools and techniques used in the surgical process vary widely. We review the available literature and focus on tools and techniques used for conducting surgery on juvenile salmonids because of the large amount of research that is conducted on them. The use of sterilized surgical instruments properly selected for a given size of fish will minimize tissue damage and infection rates, and speed the wound healing of fish implanted with transmitters. For the implantation of transmitters into small fish, the optimal surgical methods include making an incision on the ventral midline along the linea alba (for studies under 1 month), protecting the viscera (by lifting the skin with forceps while creating the incision), and using absorbable monofilament suture with a small-swaged-on swaged-on tapered or reverse-cutting needle. Standardizing the implantation techniques to be used in a study involving particular species and age classes of fish will improve survival and transmitter retention while allowing for comparisons to be made among studies and across multiple years. This review should be useful for researchers working on juvenile salmonids and other sizes and species of fish.

59 BASIC BIOLOGICAL SCIENCES↗

Introducing the Planar Laser-Induced Fluorescence Technique (PLIF) to Measure Mixing Time in Gas-Stirred Ladles

The planar laser-induced fluorescence (PLIF) technique was implemented to measure mixing time in a 1/17 water model of a 200-ton ladle furnace. The results were compared to those obtained using the conventional method of pH probes. PLIF determinations were done at two different planes, and pH probe determinations were performed at two different locations. The results suggest that mixing times measured by PLIF are similar to those obtained under optimal conditions by the pH probe and that PLIF technique is more accurate and less sensitive to the location of the measurement than the pH probe method. In addition, the particle image velocimetry (PIV) technique was used to measure the effect of the immersed probe on the fluid-dynamic structure of the system. The presence of the probe affects greatly fluid dynamics and consequently the mixing behavior, which could explain the differences found in its mixing time measurements at different probe locations. This study shows the feasibility of the PLIF technique used to measure mixing time in physical models of gas-stirred ladles; it is not intrusive and allows the visualization of the mixing phenomena in a complete plane of the system.

36 MATERIALS SCIENCE↗

Comparative In Vitro Evaluation Between Zirconia and Veneer Ceramic Materials Using Different Techniques

Zirconia surface treatment using different techniques could be employed to overcome the delamination issue reported between veneering ceramic materials and the corresponding zirconia core. The study subjected yttria partially stabilized zirconia core material to grinding and sandblasting as a first surface treatment. An airbrush gun spraying technique was used to coat a uniform thin layer of veneering ceramic (IPS e.max Ceram and Noritake Cerabien ZR) on the core materials followed by performing laser scanning as a second surface treatment. The specimens were investigated for surface topography, interface analysis, elemental compositions, phase transformation, and fracture mode patterns using profilometer, SEM, EDS, XRD, and stereomicroscope. The impact of laser scanning on the shear bond strength before and after storage of specimens in artificial saliva was also studied. Transformable tetragonal phase to monoclinic was predominant in sandblasted specimens followed by laser scanning with observation of micro-cracks at interface. The grinding followed by laser scanning yielded satisfactory outcomes in terms of the presence of coating property. The phase transformation was not detected through the latter technique. The technique greatly enhanced the roughness property and bond strength values which might be considered as a reliable application to improve the longevity of fixed dental crowns in load bearing areas.

36 MATERIALS SCIENCE↗

A Review of the Influence of Processing Parameters on ODS Steels Produced via Additive Manufacturing Techniques

Abstract This paper reviews current observations regarding processing conditions for oxide dispersion-strengthened steels consolidated through additive manufacturing techniques. Variations in ODS steels observed across process parameters include changes in grain size, grain texture, oxide size, density of oxides, porosity, melt pool characteristics, and mechanical properties. These properties were then compared across techniques to understand which techniques and processing conditions lead to the highest strength, ductility, and oxide density. Current literature suggests that a mix of grain types, in the form of either morphology or phase, can significantly increase the strength of printed ODS steels. Meanwhile, the most ductile samples, regardless of consolidation technique or matrix material, were made from feedstock with oxide additions located on the powder surface. Reported grain and oxide sizes were plotted against the ratio of laser power to scan speed, volumetric energy density, and normalized enthalpy. No strong correlation between these values and microstructural features was observed. The plots that were made suggest that a larger data set, more in-depth representative equations, and more defined material properties as a function of specific feedstock used are necessary to determine a value that can be correlated to the printed ODS steel microstructure.

deJong, Matthew↗

Transseptal Puncture: Devices, Techniques, and Considerations for Specific Interventions

Purpose of Review: Transseptal puncture is a routinely performed interventional cardiology procedure for an array of cardiac diseases. We aimed to review the current status of available devices and techniques of transseptal puncture with consideration to specific interventions. Recent Findings: Except for a few modifications, devices for transseptal puncture technique has not changed much compared to when it was first described almost 60 years ago. For difficult transseptal puncture, a few newer techniques such as radio frequency needle puncture system have been used but there is lack of robust clinical study. Advanced imaging, such as intracardiac echocardiography and transesophageal echocardiography, has been found to make transseptal puncture safer. A new transseptal approach that incorporates 3D non-fluoroscopic catheter tracking systems has shown promising results in two human studies. Summary: While various modifications in the transseptal technique tailored to the specific interventions have improved procedural safety, further improvement in existing devices focusing on distinct procedure might be needed in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous Improvement of Resolving Power and Signal-to-Noise Ratio Using a Modified Hadamard Transform-Inverse Ion Mobility Spectrometry Technique

In order to improve the resolving power (RP) and signal-to-noise ratio (SNR) of ion mobility spectrometry (IMS) simultaneously, a modified Hadamard transform-inverse ion mobility spectrometry (MHT-IIMS) technique was developed. In this novel technique, a series of isolating codes were appended to each element of the pseudo random binary sequence (PRBS), and then the modified modulation sequence was formed and used to control the ion gate of the inverse IMS (IIMS). Experimental results demonstrate that the MHT-IIMS technique can significantly enhance the resolving power and SNR simultaneously by measuring the spectra of reaction ions. Furthermore, the gas sample CCl{sub 4} and CHCl{sub 3} were measured for evaluating the capability of detecting those samples which have single and multiple product ions. The results show that this novel technique is able to simultaneously improve the resolving power and SNR notablely for the real sample detection without any significant instrumental changes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved sampling technique to collect natural gas from hydrate-bearing pressure cores

High quality gas compositional data are an important factor in interpreting the genetic source of natural gas hosted in hydrate-bearing sediments and other subsurface systems. In order to accurately characterize the composition of gas samples degassed from hydrate-bearing pressure cores, one must use a reproducible sampling technique that minimizes artifacts of the sampling process. Herein, we review sediment core degassing techniques and compare data obtained from a commonly used degassing approach, which we term the standard quantitative degassing (SQD) technique, to our newly developed modified quantitative degassing (MQD) method designed to minimize atmospheric contamination and gas-water interactions. The SQD method allows sample gas to interact with water in a bubbling chamber, which we hypothesize could alter the gas composition following mixing with water or dissolved gases in the bubbling chamber. Whereas, the MQD method allows for the collection of sample gas prior to the bubbling chamber. To compare the SQD and MQD methods, we performed a side-by-side comparison of noble (He, Ne, Ar, Kr, and Xe), major (H 2 , N 2 , O 2 , and CO 2 ), and hydrocarbon (CH 4 , C 2 H 6 , C 3 H 8 , i-C 4 H 10 , C 4 H 10 , i-C 5 H 12 , C 5 H 12 ) gas concentrations and select isotopic compositions obtained using both sample collection techniques. Gas samples were collected from hydrate-bearing pressure cores recovered and maintained under hydrate stable conditions from the northern Gulf of Mexico during the UT-GOM 2 -1 Expedition. The MQD method displayed significantly lower concentrations of atmospheric gases, higher proportions of hydrocarbon gases, lower ratios of C 1 /C 2 + , and heavier stable carbon and hydrogen isotopes of methane than the SQD method. These results demonstrate that the MQD method reduced air contamination and minimized alteration of the hydrocarbon gases. Finally, we conclude this method may be important for future work that seeks to determine the composition of natural gas from pressure cores using quantitative degassing experiments, especially those seeking to measure major (e.g., N 2 ) and noble gases.

58 GEOSCIENCES↗

On The Use of Sectional Techniques for the Solution of Depolymerization Population Balances: Results on a Discrete-Continuous Mesh

To study the discrete bond-breaking phenomena of depolymerization, the use of a fully continuous Population Balance Equation (PBE) is inadequate to embody all the inherent characteristics of the process, thus resulting in the need for a discrete-continuous mesh. In this work, the performance of the three most state-of-the-art sectional techniques, i.e. the fixed pivot technique (FPT), cell average technique (CAT) and finite volume scheme (FVS) in approximating discrete depolymerization using discrete-continuous PBEs was extensively compared and evaluated. The solutions from these three methods show different accuracy depending on the breakage mechanisms. For chain-end scission, the FPT and the CAT satisfactorily predict the population densities and moments whereas the FVS fails to predict the population densities but preserves the zeroth and the first moments. In the application of a discrete-continuous model, we identified a previously-not-reported issue of a precipitous drop in the number density at the boundary of discrete and continuous region specifically for chain-end scission. We successfully fixed this problem by employing the alterations proposed in this paper, to the particle allocation functions at the boundary points. For random scission, all three sectional techniques predict the population densities and moments to a high degree of accuracy, even at a very coarse mesh, through the use of our new stoichiometric kernel which is able to closely approximate the inherently discrete bond-breaking depolymerization process. The assessments in this present work intends to provide a clear-cut direction to efficient and economical modelling of depolymerization processes.

Ahamed, Firnaaz↗

Coping with uncertainty in environmental impact assessments: Open techniques

Uncertainty is virtually unavoidable in environmental impact assessments (EIAs). From the literature related to treating and managing uncertainty, we have identified specific techniques for coping with uncertainty in EIAs. Here, we have focused on basic steps in the decision-making process that take place within an EIA setting. More specifically, we have identified uncertainties involved in each decision-making step and discussed the extent to which these can be treated and managed in the context of an activity or project that may have environmental impacts. To further demonstrate the relevance of the techniques identified, we have examined the extent to which the EIA guidelines currently used in Colombia consider and provide guidance on managing the uncertainty involved in these assessments. Some points that should be considered in order to provide greater robustness in impact assessments in Colombia have been identified. These include the management of stakeholder values, the systematic generation of project options, and their associated impacts as well as the associated management actions, and the evaluation of uncertainties and assumptions. We believe that the relevant and specific techniques reported here can be a reference for future evaluations of other EIA guidelines in different countries. - Highlights: • uncertainty is unavoidable in environmental impact assessments, EIAs; • we have identified some open techniques to EIAs for treating and managing uncertainty in these assessments; • points for improvement that should be considered in order to provide greater robustness in EIAs in Colombia have been identified; • the paper provides substantiated a reference for possible examinations of EIAs guidelines in other countries.

54 ENVIRONMENTAL SCIENCES↗

Exploratory analysis of machine learning techniques in the Nevada geothermal play fairway analysis

Play fairway analysis (PFA) is commonly used to generate geothermal potential maps and guide exploration studies, with a particular focus on locating and characterizing blind geothermal systems. This study evaluates the application of machine learning techniques to PFA in the Great Basin region of Nevada. Following the evaluation of various techniques, we identified two approaches to PFA that produced promising results, 1) supervised Bayesian probabilistic neural networks to generate geothermal potential maps with confidence intervals, and 2) unsupervised principal component analysis paired with k-means clustering to generate both cluster maps to help identify spatial patterns, as well as new combined feature inputs. We applied these techniques to perform a comparative analysis between two principal sets of geological and geophysical features related to permeability and heat and a set of positive (known geothermal resources) and negative training sites (known drill sites with unsuitable geothermal conditions). We found that these methods constrain previously unrecognized feature controls on geothermal favorability, many of which are spatially organized within the extent of cluster groups and the major structural-hydrologic domains of the study area. Furthermore, we utilized exploratory unsupervised modeling to highlight spatial relationships between input data and predictive output results of our supervised modeling. As a result, we demonstrate how our models compare to the previous Nevada PFA and how the rapid insights these machine learning techniques offer may support future assessments of both known and undiscovered blind geothermal systems in the Great Basin region of Nevada and beyond.

15 GEOTHERMAL ENERGY↗

Dose Distribution Analysis of Axillary Lymph Nodes for Three-Dimensional Conformal Radiotherapy With a Field-in-Field Technique for Breast Cancer

Purpose: We previously reported that most of axillary regions could be irradiated by the modified tangential irradiation technique (MTIT). The purpose of this study was to determine whether the three-dimensional conformal radiotherapy (3D-CRT) with a field-in-field technique improves dosimetry for the breast and axillary nodes. Methods and Materials: Fifty patients with left-sided breast cancer were enrolled. With MTIT, we planned the radiation field to be wider in the cranial direction than the standard tangential fields to include the axillary regions. With 3D-CRT, a field-in-field technique was used to spare the heart and contralateral breast to the extent possible by applying the multileaf collimator manually. Dose-volume histograms were compared for the breast, axillary region, heart, lung, and other normal tissues. Results: There were no significant differences in the percent volume of the breast receiving >90% of the prescribed dose (V90) between MTIT and 3D-CRT. The mean V90 of the level I to III axillary regions were increased from 93.7%, 48.2%, and 41.3% with MTIT to 97.6%, 85.8%, and 82.8% with 3D-CRT. 3D-CRT significantly reduced the volume of the heart receiving >30 Gy (mean, 7.6 vs. 15.9 mL), the percent volume of the bilateral lung receiving >20 Gy (7.4% vs. 8.9%), and the volume of other normal tissues receiving >107% of the prescribed dose (0.1 vs. 2.9 mL). Conclusion: The use of 3D-CRT with a field-in-field technique improves axillary node coverage, while decreasing doses to the heart, lungs, and the other normal tissues, compared with MTIT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Intraoperatively Built Custom Linked Seeds Versus Loose Seed Gun Applicator Technique Using Real-Time Intraoperative Planning for Permanent Prostate Brachytherapy

Purpose: To report our dosimetric results using a novel push-button seed delivery system that constructs custom links of seeds intraoperatively. Methods and Materials: From 2005 to 2007, 43 patients underwent implantation using a gun applicator (GA), and from 2007 to 2008, 48 patientsunderwent implantation with a novel technique allowing creation of intraoperatively built custom links of seeds (IBCL). Specific endpoint analyses were prostate D90% (pD90%), rV100% > 1.3 cc, and overall time under anesthesia. Results: Final analyses included 91 patients, 43 GA and 48 IBCL. Absolute change in pD90% ({Delta}pD90%) between intraoperative and postoperative plans was evaluated. Using GA method, the {Delta}pD90% was -8.1Gy and -12.8Gy for I-125 and Pd-103 implants, respectively. Similarly, the IBCL technique resulted in a {Delta}pD90% of -8.7Gy and -9.8Gy for I-125 and Pd-103 implants, respectively. No statistically significant difference in {Delta}pD90% was found comparing methods. The GA method had two intraoperative and 10 postoperative rV100% >1.3 cc. For IBCL, five intraoperative and eight postoperative plans had rV100% >1.3 cc. For GA, the mean time under anesthesia was 75 min and 87 min for Pd-103 and I-125 implants, respectively. For IBCL, the mean time was 86 and 98 min for Pd-103 and I-125. There was a statistical difference between the methods when comparing mean time under anesthesia. Conclusions: Dosimetrically relevant endpoints were equivalent between the two methods. Currently, time under anesthesia is longer using the IBCL technique but has decreased over time. IBCL is a straightforward brachytherapy technique that can be implemented into clinical practice as an alternative to gun applicators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Benefits of Intensity-Modulated Radiotherapy Combined With the Deep-Inspiration Breath-Hold Technique in Patients With Mediastinal Hodgkin's Lymphoma

Purpose: To assess the additional benefits of using the deep-inspiration breath-hold (DIBH) technique with intensity-modulated radiotherapy (IMRT) in terms of the protection of organs at risk for patients with mediastinal Hodgkin's disease. Methods and Materials: Patients with early-stage Hodgkin's lymphoma with mediastinal involvement were entered into the study. Two simulation computed tomography scans were performed for each patient: one using the free-breathing (FB) technique and the other using the DIBH technique with a dedicated spirometer. The clinical target volume, planning target volume (PTV), and organs at risk were determined on both computed tomography scans according to the guidelines of the European Organization for Research and Treatment of Cancer. In both cases, 30 Gy in 15 fractions was prescribed. The dosimetric parameters retrieved for the statistical analysis were PTV coverage, mean heart dose, mean coronary artery dose, mean lung dose, and lung V20. Results: There were no significant differences in PTV coverage between the two techniques (FB vs. DIBH). The mean doses delivered to the coronary arteries, heart, and lungs were significantly reduced by 15% to 20% using DIBH compared with FB, and the lung V20 was reduced by almost one third. The dose reduction to organs at risk was greater for masses in the upper part of the mediastinum. IMRT with DIBH was partially implemented in 1 patient. This combination will be extended to other patients in the near future. Conclusions: Radiation exposure of the coronary arteries, heart, and lungs in patients with mediastinal Hodgkin's lymphoma was greatly reduced using DIBH with IMRT. The greatest benefit was obtained for tumors in the upper part of the mediastinum. The possibility of a wider use in clinical practice is currently under investigation in our department.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Markerless Technique to Evaluate Daily Lung Tumor Motion Based on Conventional Cone-Beam CT Projection Data

Purpose: In this study, we present a novel markerless technique, based on cone beam computed tomography (CBCT) raw projection data, to evaluate lung tumor daily motion. Method and Materials: The markerless technique, which uses raw CBCT projection data and locates tumors directly on every projection, consists of three steps. First, the tumor contour on the planning CT is used to create digitally reconstructed radiographs (DRRs) at every projection angle. Two sets of DRRs are created: one showing only the tumor, and another with the complete anatomy without the tumor. Second, a rigid two-dimensional image registration is performed to register the DRR set without the tumor to the CBCT projections. After the registration, the projections are subtracted from the DRRs, resulting in a projection dataset containing primarily tumor. Finally, a second registration is performed between the subtracted projection and tumor-only DRR. The methodology was evaluated using a chest phantom containing a moving tumor, and retrospectively in 4 lung cancer patients treated by stereotactic body radiation therapy. Tumors detected on projection images were compared with those from three-dimensional (3D) and four-dimensional (4D) CBCT reconstruction results. Results: Results in both static and moving phantoms demonstrate that the accuracy is within 1 mm. The subsequent application to 22 sets of CBCT scan raw projection data of 4 lung cancer patients includes about 11,000 projections, with the detected tumor locations consistent with 3D and 4D CBCT reconstruction results. This technique reveals detailed lung tumor motion and provides additional information than conventional 4D images. Conclusion: This technique is capable of accurately characterizing lung tumor motion on a daily basis based on a conventional CBCT scan. It provides daily verification of the tumor motion to ensure that these motions are within prior estimation and covered by the treatment planning volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy for Whole-Brain Irradiation With Integrated Boost to Multiple Brain Metastases: Evaluation of Dose Distribution Characteristics and Comparison With Alternative Techniques

Purpose: To quantitatively evaluate dose distribution characteristics achieved with helical tomotherapy (HT) for whole-brain irradiation (WBRT) with integrated boost (IB) to multiple brain metastases in comparison with alternative techniques. Methods and Materials: Dose distributions for 23 patients with 81 metastases treated with WBRT (30 Gy/10 fractions) and IB (50 Gy) were analyzed. The median number of metastases per patient (N{sub mets}) was 3 (range, 2-8). Mean values of the composite planning target volume of all metastases per patient (PTV{sub mets}) and of the individual metastasis planning target volume (PTV{sub ind} {sub met}) were 8.7 ± 8.9 cm{sup 3} (range, 1.3-35.5 cm{sup 3}) and 2.5 ± 4.5 cm{sup 3} (range, 0.19-24.7 cm{sup 3}), respectively. Dose distributions in PTV{sub mets} and PTV{sub ind} {sub met} were evaluated with respect to dose conformity (conformation number [CN], RTOG conformity index [PITV]), target coverage (TC), and homogeneity (homogeneity index [HI], ratio of maximum dose to prescription dose [MDPD]). The dependence of dose conformity on target size and N{sub mets} was investigated. The dose distribution characteristics were benchmarked against alternative irradiation techniques identified in a systematic literature review. Results: Mean ± standard deviation of dose distribution characteristics derived for PTV{sub mets} amounted to CN = 0.790 ± 0.101, PITV = 1.161 ± 0.154, TC = 0.95 ± 0.01, HI = 0.142 ± 0.022, and MDPD = 1.147 ± 0.029, respectively, demonstrating high dose conformity with acceptable homogeneity. Corresponding numbers for PTV{sub ind} {sub met} were CN = 0.708 ± 0.128, PITV = 1.174 ± 0.237, TC = 0.90 ± 0.10, HI = 0.140 ± 0.027, and MDPD = 1.129 ± 0.030, respectively. The target size had a statistically significant influence on dose conformity to PTV{sub mets} (CN = 0.737 for PTV{sub mets} ≤4.32 cm{sup 3} vs CN = 0.848 for PTV{sub mets} >4.32 cm{sup 3}, P=.006), in contrast to N{sub mets}. The achieved dose conformity to PTV{sub mets}, assessed by both CN and PITV, was in all investigated volume strata well within the best quartile of the values reported for alternative irradiation techniques. Conclusions: HT is a well-suited technique to deliver WBRT with IB to multiple brain metastases, yielding high-quality dose distributions. A multi-institutional prospective randomized phase 2 clinical trial to exploit efficacy and safety of the treatment concept is currently under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Fast Helical 4D-CT Acquisition Technique to Generate Low-Noise Sorting Artifact–Free Images at User-Selected Breathing Phases

Purpose: To develop a novel 4-dimensional computed tomography (4D-CT) technique that exploits standard fast helical acquisition, a simultaneous breathing surrogate measurement, deformable image registration, and a breathing motion model to remove sorting artifacts. Methods and Materials: Ten patients were imaged under free-breathing conditions 25 successive times in alternating directions with a 64-slice CT scanner using a low-dose fast helical protocol. An abdominal bellows was used as a breathing surrogate. Deformable registration was used to register the first image (defined as the reference image) to the subsequent 24 segmented images. Voxel-specific motion model parameters were determined using a breathing motion model. The tissue locations predicted by the motion model in the 25 images were compared against the deformably registered tissue locations, allowing a model prediction error to be evaluated. A low-noise image was created by averaging the 25 images deformed to the first image geometry, reducing statistical image noise by a factor of 5. The motion model was used to deform the low-noise reference image to any user-selected breathing phase. A voxel-specific correction was applied to correct the Hounsfield units for lung parenchyma density as a function of lung air filling. Results: Images produced using the model at user-selected breathing phases did not suffer from sorting artifacts common to conventional 4D-CT protocols. The mean prediction error across all patients between the breathing motion model predictions and the measured lung tissue positions was determined to be 1.19 ± 0.37 mm. Conclusions: The proposed technique can be used as a clinical 4D-CT technique. It is robust in the presence of irregular breathing and allows the entire imaging dose to contribute to the resulting image quality, providing sorting artifact–free images at a patient dose similar to or less than current 4D-CT techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗