Search NASA⌕ Search

SEARCH · Search NASA

Results for “ventilators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving

The building attic usually subjects to substantial solar heat gain and has much higher temperature compared to the conditioned living space during the day, especially in summer and in hot areas. Reducing attic temperature can reduce cooling energy consumption in buildings. However, conventional techniques such as cool roof or attic ventilation, suffer from either heating penalty in winter or limited attic temperature reduction. In this work, a new roof-integrated radiative air-cooling system is introduced, which couples radiative sky cooling with attic ventilation to reduce attic temperature. A radiative air cooler with 1.08 m 2 surface area is constructed using a recently developed daytime radiative sky cooling metamaterial [Zhai et al., Science 355, pp. 1062–1066, 2017]. Experimental tests show that sub-ambient air cooling is achieved throughout 24-h day-and-night cycle in a summer day with clear sky conditions. Depending on air flow rates, measured sub-ambient temperature reductions of air are 5–8°C at night and 3–5°C at noon under direct sunlight, respectively. An in-house model is first developed for the radiative air-cooling system, the model is then coupled with EnergyPlus to study annual energy saving of buildings. The performance of the radiative air-cooling system is compared with three reference systems: shingle roof, attic ventilation, and cool roof. Results show that for a single-family house, attic temperature can be substantially reduced by 15.5–21.0°C, varying with attic insulation level, compared to shingle roof on typical summer days. Compared to a shingle roof (solar reflectance 0.25, thermal emittance 0.9) residential building with attic insulations of R-30 (RSI-5.28), R-10 (RSI-1.76), and R-0.8 (RSI-0.14), the roof-integrated radiative air-cooling system can achieve annual cooling energy savings of 0.4–1.5 kWh/m 2 (4.6–18.8%), 1.2–3.6 kWh/m 2 (10.2–41.4%), and 3.7–11.8 kWh/m 2 (26.5–76.1%) respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and mitigating airborne pathogen risk factors in school buses

Computational fluid dynamics (CFD) models were developed to simulate the impact of different ventilation scenarios on airborne exposure risks in a 72-passenger school bus. Here, scenarios and factors that were investigated included a moving vs. stationary bus, impacts of a heating unit within the bus, and impacts of alternative ventilation scenarios with different combinations of openings (e.g., windows, door, emergency hatch). Results of the simulations showed that when the bus was stationary, use of the heater increased receptor concentrations unless there was another opening. When the bus was moving, simulations with at least two sets of openings separated from each other in the forward and aft directions produced a through-flow condition that reduced concentrations via dilution from outside air by a factor of ten or more. A single opening in a moving bus generally increased concentrations throughout the cabin due to increased mixing with minimal ventilation. The cumulative exposure risk (time-averaged concentrations) was found to be inversely correlated to the air exchange rate. Stationary and moving-bus scenarios that yielded above ~20 air changes per hour resulted in the lowest cumulative exposures. Recommendations from this study were implemented in new safety and operating procedures by the Albuquerque Public Schools Transportation Center.

60 APPLIED LIFE SCIENCES↗

Dismantling the nuclear research reactor Thetis

The research reactor Thetis, in service since 1967 and stopped in 2003, is part of the laboratories of the institution of nuclear science of the University of Ghent. The reactor, of the pool-type, was used as a neutron-source for the production of radio-isotopes and for activation analyses. The reactor is situated in a water pool with inner diameter of 3 m. and a depth of 7.5 m. The reactor core is situated 5.3 m under water level. Besides the reactor, the pool contains pneumatic loops, handling tools, graphite blocks for neutron moderation and other experimental equipment. The building houses storage rooms for fissile material and sources, a pneumatic circuit for transportation of samples, primary and secondary cooling circuits, water cleaning resin circuits, a ventilation system and other necessary devices. Because of the experimental character of the reactor, laboratories with glove boxes and other tools were needed and are included in the dismantling program. The building is in 3 levels with a crawl-space. The ground-floor contains the ventilation installation, the purification circuits with tanks, cooling circuits and pneumatic transport system. On the first floor, around the reactor hall, the control-room, visiting area, end-station for pneumatic transport, waste-storage room, fuel storage room and the labs are located. The second floor contains a few laboratories and end stations of the two high speed transfer tubes. The lowest level of the pool is situated under ground level. The reactor has been operated at a power of 150 kW and had a max operating power of 250 kW. Belgoprocess has been selected to decommission the reactor, the labs, storage halls and associated circuits to free release the building for conventional reuse and for the removal of all its internals as legal defined. Besides the dose-rate risk and contamination risk, there is also an asbestos risk of contamination. During construction of the installation, asbestos-containing materials were used, which must be removed in controlled conditions. The ventilation system is considered free from nuclear contamination but it contains asbestos. This paper covers the organization of the dismantling work, the technical execution aspect and conclusions already known (dismantling is ongoing as this is written). (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Assessment of the Idaho National Laboratory Hot Fuel Examination Facility Stack Monitoring Site for Compliance with ANSI/HPS N13.1 1999

This document reports on a series of tests to determine whether the location of the air sampling probe in the Hot Fuels Examination Facility (HFEF) heating, ventilation and air conditioning (HVAC) exhaust duct meets the applicable regulatory criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria of the ANSI/HPS N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that is representative of the effluent stream. The tests conducted by PNNL during July 2010 on the HFEF system are described in this report. The sampling probe location is approximately 20 feet from the base of the stack. The stack base is in the second floor of the HFEF, and has a building ventilation stream (limited potential radioactive effluent) as well as a process stream (potential radioactive effluent, but HEPA-filtered) that feeds into it. The tests conducted on the duct indicate that the process stream is insufficiently mixed with the building ventilation stream. As a result, the air sampling probe location does not meet the criteria of the N13.1-1999 standard. The series of tests consists of various measurements taken over a grid of points in the duct cross section at the proposed sampling-probe location. The results of the test series on the HFEF exhaust duct as it relates to the criteria from ANSI/HPS N13.1-1999 are desribed in this report. Based on these tests, the location of the air sampling probe does not meet the requirements of the ANSI/HPS N13.1-1999 standard, and modifications must be made to either the HVAC system or the air sampling probe for compliance. The recommended approaches are discussed and vary from sampling probe modifications to modifying the junction of the two air exhaust streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Columbia County Habitat for Humanity Passive Townhomes

Columbia County (New York) Habitat for Humanity built a pair of townhomes to Passive House criteria with the purpose of exploring approaches for achieving Passive House performance and to eventually develop a prototype design for future projects. The project utilized a 2x6 frame wall with a structural insulated panel curtain wall and a ventilated attic over a sealed OSB ceiling air barrier. Mechanical systems include a single head, wall mounted ductless mini-split heat pump in each unit and a heat recovery ventilator. Costs were $26,000 per unit higher for Passive House construction compared with the same home built to ENERGY STAR version 3 specifications, representing about 18% of total construction cost. This report discusses the cost components, energy modeling results and lessons from construction. Two alternative ventilation systems are analyzed: a central system; and, a point-source system with small through-wall units distributed throughout the house. The report includes a design and cost analysis of these two approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Hydronic Rooftop Unit-HyPak-MA

The majority of U.S. commercial floor space is cooled by rooftop HVAC units (RTUs). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTUs are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. 36% percent of annual U.S. energy, and two-thirds of electricity, is consumed in and by buildings. Commercial buildings consume approximately 4.2 quads of energy each year at a cost of $230 billion per year, with HVAC equipment consuming 1.2 quads of electricity. More than half of all U.S. commercial floor space is cooled by packaged HVAC units, most of which are rooftop units (RTUs). Inefficient RTUs create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming5. Also, RTUs often fail to maintain adequate ventilation air and air filtration, reducing indoor air quality. This is the second HyPak project to be supported by DOE through NETL. The prior project, referred to as HyPak-1 in this report, had two rounds of prototype fabrication and testing as well as computer modeling and market research. The HyPak-1 prototypes demonstrated the high performance capabilities of the HyPak concept, but made it clear that further development was required to reduce heat exchanger cost and improve system reliability before HyPak commercialization can commence. The HyPak-1 prototypes were limited to about 25% ventilation air fraction, limiting performance and marketability. The current project is intended to develop a 'mixed-air' product that is capable of full 0-100% modulation in ventilation air fraction, hence it was referred to as HyPak-MA in the proposal. (For simplicity, the -MA has been dropped when referencing the current project.) The objective of the HyPak Project is to design, develop and test a hydronic RTU that provides a quantum improvement over conventional RTU performance. Our proposal targeted 60% and 50% reduction in electrical energy use by the HyPak RTU for dry and humid climates, respectively, when compared with a conventional unit, and reduction in peak energy consumption of 50% and 33% respectively. In addition to performance targets, our goal is to develop a production-ready design with durability, reliability and maintainability similar to air-cooled packaged equipment, and that can be commercialized immediately following the conclusion of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Leakage and Air Transfer Between Garage and Living Space

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. Important gaps and barriers addressed by this research were: (1) Developing recommendations for effective methods for precluding the flow of contaminated air from garages to living space. (2) Creating a resource for guiding home builders and retrofitters to achieve garage isolation by use of mechanical ventilation equipment. (3) Providing field measurement support for revision of the EPA Indoor airPLUS program requirements, which are part of the DOE Challenge Home program. Field test data provided in the form of technical report showing blower door test results for air leakage measurements and tracer gas testing results. Waldorf, MD 20602

Array↗

PERFORMANCE EVALUATION OF A SUSTAINABLE AND ENERGY EFFICIENT RE-ROOFING TECHNOLOGY USING FIELD-TEST DATA

Three test attics were constructed to evaluate a new sustainable method of re-roofing utilizing photo-voltaic (PV) laminates, metal roofing panels, and PCM heat sink in the Envelope Systems Research Apparatus (ESRA) facility in the ORNL campus. Figure 1 is a picture of the three attic roofs located adjacent to each other. The leftmost roof is the conventional shingle roof, followed by the metal panel roof incorporating the cool-roof coating, and third from left is the roof with the PCM. On the PCM roof, the PV panels are seen as well; they're labelled from left-to-right as panels 5, 6 and 7. The metal panel roof consists of three metal panels with the cool-roof coating; in further discussion this is referred to as the infrared reflective (IRR) metal roof. The IRR metal panels reflect the incoming solar radiation and then quickly re-emit the remaining absorbed portion, thereby reducing the solar heat gain of the attic. Surface reflectance of the panels were measured using a Solar Spectrum Reflectometer. In the 0.35-2.0 {mu}m wavelength interval, which accounts for more than 94% of the solar energy, the IRR panels have an average reflectance of 0.303. In the infrared portion of the spectrum, the IRR panel reflectance is 0.633. The PCM roof consists of a layer of macro-encapsulated bio-based PCM at the bottom, followed by a 2-cm thick layer of dense fiberglass insulation with a reflective surface on top, and metal panels with pre-installed PV laminates on top. The PCM has a melting point of 29 C (84.2 F) and total enthalpy between 180 and 190 J/g. The PCM was macro-packaged in between two layers of heavy-duty plastic foil forming arrays of PCM cells. Two air cavities, between PCM cells and above the fiberglass insulation, helped the over-the-deck natural air ventilation. It is anticipated that during summer, this extra ventilation will help in reducing the attic-generated cooling loads. The extra ventilation, in conjunction with the PCM heat sink, are used to minimize thermal stresses due to the PV laminates on sunny days. In PV laminates sunlight is converted into electricity and heat simultaneous. In case of building integrated applications, a relatively high solar absorption of amorphous silicon laminates can be utilized during the winter for solar heating purposes with PCM providing necessary heat storage capacity. However, PV laminates may also generate increased building cooling loads during the summer months. Therefore, in this project, the PCM heat sink was to minimize summer heat gains as well. The PCM-fibreglass-PV assembly and the IRR metal panels are capable of being installed directly on top of existing shingle roofs during re-roofing, precluding the need for recycling or disposal of waste materials. The PV laminates installed on the PCM attic are PVL-144 models from Uni-Solar. Each laminate contains 22 triple junction amorphous silicon solar cells connected in series. The silicon cells are of dimensions 356 mm x 239 mm (14-in. x 9.4-in.). The PVL-144 laminate is encapsulated in durable ETFE (poly-ethylene-co-tetrafluoroethylene) high light-transmissive polymer. Table 1 lists the power, voltage and current ratings of the PVL-144 panel.

14 SOLAR ENERGY↗

Building America Case Study: Columbia County Habitat for Humanity Passive Townhomes, Hudson, New York

Columbia County (New York) Habitat for Humanity built a pair of townhomes to Passive House criteria with the purpose of exploring approaches for achieving Passive House performance and to eventually develop a prototype design for future projects. The project utilized a 2x6 frame wall with a structural insulated panel curtain wall and a ventilated attic over a sealed OSB ceiling air barrier. Mechanical systems include a single head, wall mounted ductless mini-split heat pump in each unit and a heat recovery ventilator. Costs were $26,000 per unit higher for Passive House construction compared with the same home built to ENERGY STAR version 3 specifications, representing about 18 percent of total construction cost. This report discusses the cost components, energy modeling results and lessons from construction. Two alternative ventilation systems are analyzed: a central system; and, a point-source system with small through-wall units distributed throughout the house. The report includes a design and cost analysis of these two approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Fan Efficiency - Code Notes

Over the past several code cycles, mechanical ventilation requirements have been added to ensure adequate outside air is provided for ventilation whenever residences are occupied. These ventilation requirements can be found in the International Residential Code for homes and the International Mechanical Code for dwelling units in multifamily buildings.

Residential buildings, homes, efficacy, HVAC, whol↗

A Rabbit Irradiation Platform for Outcome Assessment of Lung Stereotactic Radiosurgery

Purpose: To evaluate a helical tomotherapy-based rodent radiosurgery platform that reproduces human image-guided radiosurgery treatment to study radiobiologic effects of stereotactic radiosurgery on lung tissues using functional magnetic resonance imaging (MRI). Methods and Materials: Hypofractionated radisourgery (20 Gy x 3) was delivered to the right lung of three New Zealand rabbits using Helical TomoTherapy with MVCT image guidance. Contrast-enhanced MR perfusion, hyperpolarized helium-3 MR ventilation, and CT were obtained before radiation and monthly for 4 months after radiation. All MRI was performed on a 1.5-T whole-body scanner with broad-band capabilities. Results: Precise dose delivery to 1.6 cc of the lower right lung was achieved without additional immobilization. No deficits were detected at baseline with respect to perfusion and ventilation. Lung perfusion deficits in the irradiated lung regions began at 2 months after radiation and worsened with time. No ventilation deficits were observed after radiation. Decrease in lung CT density in irradiated regions was observed after radiation, but the changes were less significant than those in perfusion MRI. Conclusions: We demonstrated that highly conformal radiation can be reproducibly delivered to a small volume of rodent lung on a widely available clinical unit. The radiation-induced lung injury can be detected as early as 2 months after radiation with perfusion MRI. The primary pattern of injury agrees with previously reported endothelial damage to radiosurgical radiation doses. This experimental design provides a cost-effective methodology for producing radiosurgical injuries in rodents that reproduces current human treatments for studying radiation injury and agents that might affect it.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conceptual Approach For Estimating Potential Air Toxics And Radionuclide Airborne Emissions From A Temporary Exhaust System For The 216-Z-9 Crib Removal Action

The 216-Z-9 Crib, located at the Hanford Nuclear Reservation in southeastern Washington State, was the site of a successful mining effort to recover plutonium from the contaminated soils at the disposal site. A CERCLA Action Memorandum (AM) issued by the U.S. Department of Energy (DOE) requires the removal of the buildings associated with this mining effort to facilitate a remedial action planned for the near future. The decontamination and demolition of the 216 Z-9 Crib facilities is required under a consent order between the DOE, the U.S Environmental Protection Agency (EPA) and the Washington State Department of Ecology (Ecology). Removal of the buildings located on and near the concrete cover slab over the 216-Z-9 Crib will require removal of the large soil-packaging glovebox located inside the 216-Z- 9A Building. Prior to cleaning out the glovebox, it will be necessary to provide active filtered ventilation capability to ensure a negative pressure exists between the glovebox and the adjacent airspace while hands-on work proceeds within. The glovebox floor is open to the Z-9 crib cavern environment below. For this reason the crib and glovebox currently share a common airspace. The functional requirements for safely conducting work within the glovebox include provision of a negative pressure in the box of about 0.5 inches of water gage (nominal) less than the interior of the building. In addition, the building surrounding the glovebox will be maintained at a slight negative pressure with respect to outdoor ambient pressure. In order to assess the relevant and appropriate clean air requirements for the new temporary ventilation system and associated emissions monitoring, it was necessary to reliably predict the nature of the exhaust air stream. Factors used to predict the presence and concentrations of certain radionuclide particulates and certain gases considered to be air toxics, included reliability parameters, flow rates, radionuclide content, and off-gas compositions. Radionuclide content includes transuranic isotopes, primarily of plutonium and americium. Air toxics include carbon tetrachloride, butane, methanol, acetone and toluene. Flow rate prediction was based on available design and test data and considered equipment sizes, glovebox negative pressure requirements, and filter flow characteristics. The approach used to predict the off-gas composition from the crib required experience-based predictive analysis combined with crib head space analytical results. Input information for emission estimates included: (1) gas composition sample data obtained from recent samples taken within the crib head space during static conditions, and (2) air in-leakage/dilution estimates based on physical characteristics of both the crib and the new temporary ventilation system. The conceptual approach combined measurement-based data with conservative assumptions, and provides the estimates necessary to determine relevance and appropriateness of substantive requirements under federal and state laws and regulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Andra's strategy and approach for operational safety of French underground facility Cigeo - 15127

According to the French Act on radioactive waste of 28 June 2006, Andra shall design a reversible repository. In response to this demand, Andra is developing the industrial project namely 'Cigeo', a reversible geological disposal facility for HLW and ILW located in Meuse/Haute-Marne. The previous safety cases of 2005, 2009 and 2012 give a sound basis to assess Cigeo's safety both for the operational and post-closure periods. Regarding operational safety, in this new stage of the project, the challenging issues for the preparation of the safety case are the following: - To adapt the various regulatory frameworks (nuclear and non-nuclear) to the underground facility - To design the underground facility and handling equipment's to reduce at first risks in the underground facility as such radioactive particles release, gas explosion, fire and co-activity and limit their consequence. - To establish waste acceptance criteria to be fulfilled by waste producers in line with operational safety and design options. The objective of the paper is to present the experience of Andra in operation safety of the underground facility of Cigeo. Operational safety for Cigeo is assessed as much as possible according to the existing French regulations and guidance for nuclear facilities. Indeed, compared to existing nuclear facilities, a geological repository is a specific case due to the existence of underground facilities with particularities such as: - ventilation management in a large scale underground facility, - fire risk management. As an input for the industrial design of Cigeo for operation, Andra defined a fire guidance and a specific reference safety guidance, based on the adaptation of the French nuclear regulatory texts for and when feasible to mines and tunnels regulatory texts and on its own experience gained through safety operational reports since 2005 and their reviews by the Safety Authority. - underground co-activity of nuclear operation with construction works. According to the common 'defense-in depth' principle for nuclear facilities, these guidelines for the industrial design of Cigeo for operation consider the successive levels of defense of: - Preventing the risk and its spreading by design and construction; - Detecting incidents and early fighting by design and operation dispositions (detection and control systems, survey procedure); - Controlling incidents and limiting of their consequences by safeguarding systems, specific procedures. At that stage, design options for Cigeo constitute an adequate response to the operational safety functions and requirements: - Two levels of containment are set up: the first one is ensured by the waste package, the second one is ensured from the surface facility to the disposal vaults by the transfer cask during the transfer of waste packages in the disposal vaults by the disposal vault itself and a nuclear ventilation with HEPA filter; - Favorable options for fire risk prevention and mitigation: transport system minimizing heat load (cable car for the transfer from the surface, electric transfer engines), twin access tunnels to ease fire-fighting and evacuation...; - Permanent complete physical separation of nuclear zone and construction zone (including ventilation systems). In practice, operation safety assessment of Cigeo, designed following the aforesaid reference safety guidelines, follows a common risk analysis (internal aggressions such as auxiliary losses, chemical and toxic risks, fall or collision, fire, human factors and external aggressions such as earthquake, air traffic, flooding) with the following steps: - Identification of the major risks and the design basis scenarios that have to be considered for dimensioning of the installations and the safety devices; - On the basis of these different situations, those who will have to be quantified are identified; one or more representative and envelop situations are chosen in order to evaluate robustness of the installation. Quantitative evaluation of these situations permits to: - identify the consequences on man, environment and installation, and in particular to gain confidence in the maintaining of the safety functions; - identify or define the technic and/or organisational dispositions classified as 'important elements for protection' (IEP); - Situations beyond dimensioning permit to verify the robustness of the installation. They permit, on one hand to identify possible complementary material or organisational dispositions; on the other hand, to define the 'hard core' i.e. structures, systems and components that permit to maintain the confinement function of radioactive substance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Theory of Carbon Dioxide Absorption by Hanford Waste - 18208

Hanford nuclear waste has a very high pH, and Hanford tanks are ventilated with air. Air has CO{sub 2(g)} in it, which is an acid, so it has some affinity for the waste. The absorption of CO{sub 2} by the waste is important because CO{sub 2} absorption consumes hydroxide at the liquid-air interface, and the hydroxide is important for inhibiting tank corrosion. NaOH is periodically added to some tanks in order to mitigate the surface acidification. The NaOH added then becomes part of the waste and must be treated as waste, increasing the cost of the mission. The Hobbs Equation, developed at the Savannah River site, is used at Hanford to predict CO{sub 2} absorption from the tank ventilation system. In this study, the Hobbs Equation functional form is theoretically evaluated from thermodynamic calculations of CO{sub 2} absorption, and diffusion rates in the waste surface. This study theoretically justifies the empirical equation reported by Hobbs. Thermodynamic calculations performed using the Environmental Simulation Program (ESP) software on a typical double-shell tank waste composition indicate that essentially 100 % of CO{sub 2} that contacts the waste will react with the waste whenever the pH is above 10. In the 1990's, a substantial amount of data was collected on the concentration of CO{sub 2} in the off-gas of ventilated double-shell tanks at Hanford. This historic data was mined in order to determine the quantity of CO{sub 2} absorbed by the waste. The results of this data mining activity determined that tanks below approximately pH 10 (i.e., tank 241-AN-107) will show limited CO{sub 2} absorption, consistent with both the Hobbs model and the theory developed here. Two other tank with higher pH showed contrasting CO{sub 2} absorption. One showed substantial CO{sub 2} absorption, and the other showed minimal CO{sub 2} absorption despite the high waste pH in one tank, presumably because there was minimal contact between the waste surface and most of the air flow. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effectiveness of Urban Shelter-in-Place. III: Commercial Districts

In the event of a toxic chemical release to the atmosphere, shelter-in-place (SIP) is an emergency response option available to protect public health. This paper is the last in a three-part series that examines the effectiveness of SIP at reducing adverse health effects in communities. We model a hypothetical chemical release in an urban area, and consider SIP effectiveness in protecting occupants of commercial buildings. Building air infiltration rates are predicted from empirical data using an existing model. We consider the distribution of building air infiltration rates both with mechanical ventilation systems turned off and with the systems operating. We also consider the effects of chemical sorption to indoor surfaces and nonlinear chemical dose-response relationships. We find that commercial buildings provide effective shelter when ventilation systems are off, but that any delay in turning off ventilation systems can greatly reduce SIP effectiveness. Using a two-zone model, we find that there can be substantial benefit by taking shelter in the inner parts of a building that do not experience direct air exchange with the outdoors. Air infiltration rates vary substantially among buildings and this variation is important in quantifying effectiveness for emergency response. Community-wide health metrics, introduced in the previous papers in this series, can be applied in pre-event planning and to guide real-time emergency response.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗