Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Conformal Doping of FINFETs: a Fabrication and Metrology Challenge

Whereas the introduction of 3D-dimensional devices such as FINFETs may be a solution for next generation technologies, they do represent significant challenges with respect to the doping strategies and the junction characterization. Aiming at a conformal doping, classical beam implants fail due to the differences in impact angle, ion incorporation efficiency and the effect of wafer rotation. Moreover shadowing represents an additional limitation for larger tilt angles when considering closely spaced FINs. Plasma immersion doping is an alternative approach which holds the promise of conformality but is also quite challenging and relies on secondary processes such as resputtering, deposition and in diffusion etc. Its implementation is compromised by concurrent artifacts, sputter erosion being the most important one. In support of these developments the measurement of the 3D-dopant distribution and the identification of conformality is essential requiring adequate metrology such as Scanning Spreading Resistance Microscopy, SIMS through FINs, resistors and the Tomographic Atomprobe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single atom visibility in STEM optical depth sectioning

The continuing development of aberration correctors for the scanning transmission electron microscope (STEM) offers the possibility of locating single atoms in crystals in 3D via optical depth sectioning. The main factors that determine the feasibility of such an approach are visibility and dose requirements. In this paper, we show how Poisson's statistics can be quantitatively incorporated into STEM image simulations and demonstrate that the 3D location of single cerium atoms in wurtzite-type aluminum nitride is indeed feasible under large-angle illumination conditions with a relatively low dose. We also show that chromatic aberration does not presently represent a limitation provided a cold field emission source is used. Finally, these results suggest efforts into improved aberration corrector designs for larger illumination angles that offer significant potential for 3D structure determination of materials.

36 MATERIALS SCIENCE↗

3D Imaging and Manipulation of Subsurface Selenium Vacancies in PdSe 2

Two-dimensional materials such as layered transition-metal dichalcogenides (TMDs) are ideal platforms for studying defect behaviors, an essential step towards defect engineering for novel material functions. Here, we image the 3D lattice locations of selenium-vacancy V Se defects and manipulate them using a scanning tunneling microscope (STM) near the surface of PdSe 2 , a recently discovered pentagonal layered TMD. The V Se show a characterisitc charging ring in a spatially resolved conductance map, based on which we can determine its subsurface lattice location precisely. Using the STM tip, not only can we reversibly switch the defect states between charge neutral and charge negative, but also trigger migrations of V Se defects. This allows a demonstration of direct “writing” and “erasing” of atomic defects and tracing the diffusion pathways. First-principles calculations reveal a small diffusion barrier of V Se in PdSe 2 , which is much lower than S vacancy in MoS 2 or an O vacancy in TiO 2 . As a result, this finding opens an opportunity of defect engineering in PdSe 2 for such as controlled phase transformations and resistive-switching memory device application.

74 ATOMIC AND MOLECULAR PHYSICS↗

WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strands of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding. Disclosure: XDR Radiography has loaned our research group the digital x-ray detector used in this work. CoI: None.

60 APPLIED LIFE SCIENCES↗

High psedocapacitance of MnO2 nanoparticles in graphitic disordered mesoporous carbon at high scan rates

Nanocomposites composed of MnO{sub 2} and graphitic disordered mesoporous carbon (MnO{sub 2}/C) were synthesized for high total specific capacitance and redox pseudocapacitance (C{sub MnO{sub 2}}) at high scan rates up to 200 mV s{sup -1}. High resolution transmission electron microscopy (HRTEM) with energy dispersive X-ray spectroscopy (EDX) demonstrated that MnO{sub 2} nanodomains were highly dispersed throughout the mesoporous carbon structure. According to HRTEM and X-ray diffraction (XRD), the MnO{sub 2} domains are shown to be primarily amorphous and less than 5 nm in size. For these composites in aqueous 1 M Na{sub 2}SO{sub 4} electrolyte, C{sub MnO{sub 2}} reached 500 F/g{sub MnO{sub 2}} at 2 mV s{sup -1} for 8.8 wt% MnO{sub 2}. A capacitance fade of only 20% over a 100-fold change in scan rate was observed for a high loading of 35 wt% MnO{sub 2} with a C{sub MnO{sub 2}} of 310 F/g{sub MnO{sub 2}} at the highest scan rate of 200 mV s{sup -1}. The high electronic conductivity of the graphitic 3D disordered mesoporous carbon support in conjunction with the thin MnO{sub 2} nanodomains facilitate rapid electron and ion transport offering the potential of improved high power density energy storage pseudocapacitors.

36 MATERIALS SCIENCE↗

High pseudocapacitance of MnO2 nanoparticles in graphitic disordered mesoporous carbon at high scan rates

Nanocomposites composed of MnO{sub 2} and graphitic disordered mesoporous carbon (MnO{sub 2}/C) were synthesized for high total specific capacitance and redox pseudocapacitance (C{sub MnO{sub 2}}) at high scan rates up to 200 mV s{sup -1}. High resolution transmission electron microscopy (HRTEM) with energy dispersive X-ray spectroscopy (EDX) demonstrated that MnO{sub 2} nanodomains were highly dispersed throughout the mesoporous carbon structure. According to HRTEM and X-ray diffraction (XRD), the MnO{sub 2} domains are shown to be primarily amorphous and less than 5 nm in size. For these composites in aqueous 1 M Na{sub 2}SO{sub 4} electrolyte, C{sub MnO{sub 2}} reached 500 F/g{sub MnO{sub 2}} at 2 mV s{sup -1} for 8.8 wt% MnO{sub 2}. A capacitance fade of only 20% over a 100-fold change in scan rate was observed for a high loading of 35 wt% MnO{sub 2} with a C{sub MnO{sub 2}} of 310 F/g{sub MnO{sub 2}} at the highest scan rate of 200 mV s{sup -1}. The high electronic conductivity of the graphitic 3D disordered mesoporous carbon support in conjunction with the thin MnO{sub 2} nanodomains facilitate rapid electron and ion transport offering the potential of improved high power density energy storage pseudocapacitors.

36 MATERIALS SCIENCE↗

Science Goals for the ARM Recovery Act Radars

Science Goals for the ARM Recovery Act Radars. In October 2008, an ARM workshop brought together approximately 30 climate research scientists to discuss the Atmospheric Radiation Measurement (ARM) Climate Research Facility's role in solving outstanding climate science issues. Through this discussion it was noted that one of ARM's primary contributions is to provide detailed information about cloud profiles and their impact on radiative fluxes. This work supports cloud parameterization development and improved understanding of cloud processes necessary for that development. A critical part of this work is measuring microphysical properties (cloud ice and liquid water content, cloud particle sizes, shapes, and distribution). ARM measurements and research have long included an emphasis on obtaining the best possible microphysical parameters with the available instrumentation. At the time of the workshop, this research was reaching the point where additional reduction in uncertainties in these critical parameters required new instrumentation for applications such as specifying radiative heating profiles, measuring vertical velocities, and studying the convective triggering and evolution of three-dimensional (3D) cloud fields. ARM was already operating a subset of the necessary instrumentation to make some progress on these problems; each of the ARM sites included (and still includes) a cloud radar (operating at 35 or 94 GHz), a cloud lidar, and balloon-borne temperature and humidity sensors. However, these measurements were inadequate for determining detailed microphysical properties in most cases. Additional instrumentation needed to improve retrievals of microphysical processes includes radars at two additional frequencies for a total of three at a single site (35 GHz, 94 GHz, and a precipitation radar) and a Doppler lidar. Evolving to a multi-frequency scanning radar is a medium-term goal to bridge our understanding of two-dimensional (2D) retrievals to the 3D cloud field. These additional microphysical measurements would allow detailed cloud properties to be derived even in the presence of light precipitation. It is important to couple these detailed measurements of cloud microphysics to vertical motion on the cloud scale to couple microphysics with meteorological processes. Vertically pointing Doppler radars provide the vertical motion of cloud particles but, to separate particle motion from air motion, a wind profiler is required. The American Recovery and Reinvestment Act provided the means to address these needs and implement a multi-frequency suite of radars, including scanning radars, at each of the ARM sites. In addition, Doppler lidars have been deployed at several sites. With these new measurement capabilities, ARM has the measurement capabilities to tackle the problems of improving microphysical profile descriptions and evaluating the relationship between our current narrow-field-of view, zenith perspective on clouds to a description of the full 3D cloud field and its temporal evolution.

54 ENVIRONMENTAL SCIENCES↗

Dynamic in-situ imaging of methane hydrate formation and self-preservation in porous media

Here we present the results of dynamic in-situ 3D X-ray imaging of methane hydrates microstructure during methane hydrate formation and dissociation in sand samples. Short scanning times and high resolution provided by synchrotron X-rays allowed for better understanding of water movement and different types of gas-hydrate formation. Complementing previous observations, we conclude that the process of gas-hydrate formation is accompanied by the water movements caused by cryogenic water suction that happens in sequences of short fast movements with longer equilibrium states in between (when the water is immobile). Based on the 3D microstructure we identified two distinct types of gas-hydrate formation: (i) into the gas pockets and (ii) inside water volumes. For both mechanisms we do not see problems in gas or water supply to support the gas-hydrate formation. The rate of dissociation in the self-preservation mode (pressure drop at negative temperatures) appears to be different for these two types of gas hydrates. This means that the history of the gas-hydrate formation may influence its behaviour at the dissociation stage (e.g. gas-hydrate production).

58 GEOSCIENCES↗

R and DE Robotic Sensor Intern Team: Remote 3D Mapping Overview

The Department of Energy (DOE) nuclear complex includes many hazardous and challenging environments that must be inspected remotely and routinely for structural integrity evaluation and long-term planning purposes. The H-Canyon Air Exhaust (HCAEX) Tunnel biannual inspection is an example of such an environment. Presently inspections are performed by teleoperated robotic crawlers provide low resolution video feedback to the structural engineers. Advanced sensors such as Lidar and panospheric hi-res cameras have the potential to provide additional valuable data in future inspections. UT-Austin Lidar work in support of an H-Canyon deployment began with the DOE EM sponsored H-Canyon Integrated Research Project. The R and DE Robotic Sensor intern team includes two of the UT-Austin Masters students working on Lidar development to facilitate the pulling of university developed solutions to the field. The goal of this project is to develop a suite of sensors that could be used to gather advanced data in future HCAEX tunnel inspections. Of particular interest is the ability to map the tunnel walls at an accuracy that will allow for the comparison of two scans performed at different time periods to estimate the concrete erosion rate. Additionally, the development of the 3D point cloud in the GPS denied environment is the first step in being able to collect and overlay other 3D data such as radiation mapping. Project specific goals include: - Design and develop 3D mapping sensor suite. Merge Lidar point cloud with high res camera images Incorporate Inertial Measurement Unit (IMU) to assist with positioning. - Develop sensor software and user GUI Sensor data collection and integration software User GUI for reach back system. - Test solution on crawler in tunnel test bed Use crawler base similar to H-Canyon planned crawler Design and build test bed simulating tunnel conditions. To facilitate rapid sensor integration, software coding and user GUI development, the Robot Operating System (ROS) was employed as the development platform. ROS is a set of open source software libraries and tools that assist with the building of robot applications. ROS includes drivers for many sensors, state-of-the-art algorithms, and powerful developer tools. Sensors selected for the summer intern solution included assessment as to whether they possessed ROS drivers and associated sample code. Additionally, the ROS 3D Robot Visualizer (rviz) tool has been employed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stress and Strain Heterogeneity and Persistence in Uniaxially‐ and Triaxially‐Loaded Sandstone

Two critical questions in brittle rock mechanics are how rocks developed localized strains and to what extent internal stress heterogeneity controls this localization and subsequent macroscopic failure. Definitive answers have not yet been found, but would provide insight into rock fracture mechanics as relevant to hydrocarbon extraction and sequestration. Here, we use synchrotron X‐ray tomography (XRT) and 3D X‐ray diffraction (3DXRD) during uniaxial and triaxial tests on Nugget and Bentheimer sandstones to examine strain and stress localization prior to mechanical failure. 3DXRD was used to measure intra‐granular lattice strains which were used to compute elastic stress tensors of each grain. Digital volume correlation (DVC) was applied to XRT images to determine the strain field in the sample. Both samples featured marked spatial heterogeneity, localization, and temporal persistence of elevated stresses and strains during their mechanical deformation toward failure. Both samples featured a majority of grains with at least one principal stress component that was tensile, a signature of the influence of heterogeneity on stress transmission. Measurements further revealed that compressive stress orientations and statistics evolved in a similar manner to those of inter‐particle forces in loose granular materials, with triaxially‐compressed rock exhibiting enhanced grain stress heterogeneity compared to uniaxially‐compressed rock. Our results complement recent work by others who employed XRT and scanning 3DXRD to study triaxially‐compressed sandstone, but extend those results to uniaxial compression, sandstones of varied porosity, and grain stress measurements throughout the 3D full extent of the samples rather than in a single layer examined with scanning 3DXRD.

58 GEOSCIENCES↗

Clusters, molecular layers, and 3D crystals of water on Ni(111)

We examined the growth and stability of ice layers on Ni(111) up to ∼7 molecular layers (ML) thick using scanning tunneling microscopy. At low coverage, films were comprised of ∼1 nm wide two-dimensional (2D) clusters. Only above ∼0.5 ML did patches of continuous 2D layers emerge, coexisting with the clusters until the first ML was complete. The structure of the continuous layer is clearly different from that of the 2D clusters. Subsequently, a second molecular layer grew on top of the first. 3D crystallites started to form only after this 2nd ML was complete. 2D clusters re-appeared when thicker films were partially evaporated, implying that these clusters represent the equilibrium configuration at low coverage. Binding energies and image simulations computed with density functional theory suggest that the 2D clusters are partially dissociated and surrounded by H adatoms. The complete 2D layer contains only intact water molecules because of the lack of favorable binding sites for H atoms. We propose molecular structures for the 2D layer that are composed of the same pentagon-heptagon binding motif and water density observed on Pt(111). The similarity of the water structures on Pt and Ni suggests a general prescription for generating low-energy configurations on close-packed metal substrates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2D-to-3D image translation of complex nanoporous volumes using generative networks

Image-based characterization offers a powerful approach to studying geological porous media at the nanoscale and images are critical to understanding reactive transport mechanisms in reservoirs relevant to energy and sustainability technologies such as carbon sequestration, subsurface hydrogen storage, and natural gas recovery. Nanoimaging presents a trade off, however, between higher-contrast sample-destructive and lower-contrast sample-preserving imaging modalities. Furthermore, high-contrast imaging modalities often acquire only 2D images, while 3D volumes are needed to characterize fully a source rock sample. In this work, we present deep learning image translation models to predict high-contrast focused ion beam-scanning electron microscopy (FIB-SEM) image volumes from transmission X-ray microscopy (TXM) images when only 2D paired training data is available. We introduce a regularization method for improving 3D volume generation from 2D-to-2D deep learning image models and apply this approach to translate 3D TXM volumes to FIB-SEM fidelity. We then segment a predicted FIB-SEM volume into a flow simulation domain and calculate the sample apparent permeability using a lattice Boltzmann method (LBM) technique. Results show that our image translation approach produces simulation domains suitable for flow visualization and allows for accurate characterization of petrophysical properties from non-destructive imaging data.

58 GEOSCIENCES↗

Biological serial block face scanning electron microscopy at improved z-resolution based on Monte Carlo model

Serial block-face electron microscopy (SBEM) provides nanoscale 3D ultrastructure of embedded and stained cells and tissues in volumes of up to 107µm3. In SBEM, electrons with 1–3keV energies are incident on a specimen block, from which backscattered electron (BSE) images are collected with x, y resolution of 5–10nm in the block-face plane, and successive layers are removed by an in situ ultramicrotome. Spatial resolution along the z-direction, however, is limited to around 25nm by the minimum cutting thickness. To improve the z-resolution, we have extracted depth information from BSE images acquired at dual primary beam energies, using Monte Carlo simulations of electron scattering. The relationship between depth of stain and ratio of dual-energy BSE intensities enables us to determine 3D structure with a ×2 improvement in z-resolution. We demonstrate the technique by sub-slice imaging of hepatocyte membranes in liver tissue.

36 MATERIALS SCIENCE↗

Patch-Based Convolutional Neural Networks for Multiple Microstructural Features Detection in FIB-SEM Micrographs of Irradiated Nuclear Fuel

Focused ion beam scanning electron microscopy (FIB-SEM) tomography has increasingly been utilized for acquiring three-dimensional (3D) microstructure features at the sub-micron scale in irradiated nuclear materials. This technique involves sequential ion beam slicing followed by electron beam imaging and compositional mapping using energy dispersive spectroscopy (EDS). Despite its growing use, several challenges persist. These include the time-intensive nature of data collection of EDS data, difficulties in distinguishing between various microstructures, and issues with image alignment. These challenges currently limit the broader application of FIB-SEM tomography in the field. To overcome these limitations, we propose using convolutional neural networks (CNNs) to automate microstructure identification in SEM images. Our study introduces a new framework for identifying microstructures in irradiated U-10Zr (wt. %) metallic fuel with limited annotated data. The framework includes the creation of a reliable annotated dataset with paired SEM and ground truth data from EDS maps, the applications of CNNs for microstructure identification, and the validation of model performance. Specifically, we employed the Segment Anything Model (SAM) to align SEM images with corresponding EDS maps and focused ion beam (FIB) tomography SEM data. We evaluate several models, including Patch-based U-Net, Attention U-Net, and Residual U-Net, finding that patch-based U-Net exhibits superior segmentation performance and consistency. This approach reduces reliance on EDS detectors and aids in accelerating nuclear material analysis process, highlighting the potential of advanced deep learning techniques to improve microstructural understanding in nuclear material. This is the first framework to integrate SAM and Patch-based CNN models for semantic segmentation of irradiated nuclear materials, with potential applicability to other tomography datasets.

36 - MATERIALS SCIENCE↗

3D Printing Catalytic Electrodes for Solar-Hydrogen Devices

Hydrogen production through water-splitting systems showed promising pathway to achieve <$2/kg cost target set by Department of Energy (DOE). As far, most efforts have been devoted to new electrocatalytical materials discovery. In contrast, the impact of architecture of the electrocatalysts as well as mass transport within the gas diffusion layers has not been well explored. In this project, we developed a new ink formulation with earth-abundant elements nickel and molybdenum (NiMo) for catalytical 3-dimentional (3D) electrodes in water-splitting devices. The NiMo electrodes fabricated via additive manufacturing have been characterized and tested. The architecture, morphology and compositions of the NiMo electrodes have been confirmed by Scanning Electric Microscopy (SEM) and Powder X-Ray Diffraction (XRD). We have demonstrated that the catalyst precursor survived the whole fabrication and post-treatment process. Furthermore, the NiMo 3D electrodes in this study exhibited state-of-art hydrogen evolution reaction (HER) performance, ~ 60 mV over potential for over 24 hours operation. The high performance of the 3D catalytical electrodes is attributed to large roughness factors (RF) of the electrodes and highly efficient mass transport. This study is in line with DOE initiative H2@Scale and national energy security missions at LLNL.

36 MATERIALS SCIENCE↗

Synthesis, surface group modification of 3D MnV{sub 2}O{sub 6} nanostructures and adsorption effect on Rhodamine B

Highlights: ► Fabrication of urchin-like MnV{sub 2}O{sub 6} with oxygen-containing surface groups. ► Mn{sub 0.5}V{sub 2}O{sub 5}·nH{sub 2}O as an intermediate product holds the key to the final products. ► 3D architectures of MnV{sub 2}O{sub 6} with oxygen-containing surface groups as sorbent. ► The sorbent shows a good adsorption ability. -- Abstract: Highly uniform 3D MnV{sub 2}O{sub 6} nanostructures modified by oxygen functional groups (-COO-) were successfully prepared in large quantities by an approach involving preparation of vanadyl ethylene glycolate as the precursor. The growth and self-assembly of MnV{sub 2}O{sub 6} nanobelts and nanorods could be readily tuned by additive species and quantities, which brought different morphologies and sizes to the final products. With a focus on the regulation of structure, the formation process of 3D architectures of MnV{sub 2}O{sub 6} by self-assembly of nanobelts was followed by field emission scanning electron microscopy (FE-SEM) and X-ray diffraction (XRD). The consecutive processes of vanadyl ethylene glycolate and benzoyl peroxide assisted formation of layered structure Mn{sub 0.5}V{sub 2}O{sub 5}·nH{sub 2}O, growth of aligned MnV{sub 2}O{sub 6} nanobelts, and oriented assembly were proposed for the growth mechanism. The band gap vs. different morphology was also studied. Optical characterization of these MnV{sub 2}O{sub 6} with different morphologies showed direct bandgap energies at 1.8–1.95 eV. The adsorption properties of 3D MnV{sub 2}O{sub 6} nanostructures synthesized under different conditions were investigated through the removal test of Rhodamine B in aqueous water, and the 3D nanostructures synthesized with 30 g L{sup −1} benzoyl peroxide showed good adsorption capability of Rhodamine B.

36 MATERIALS SCIENCE↗

Improvements in intrinsic feature pose measurement for awake animal imaging

Development has continued with intrinsic feature optical motion tracking for awake animal imaging to measure 3D position and orientation (pose) for motion compensated reconstruction. Prior imaging results have been directed towards head motion measurement for SPECT brain studies in awake unrestrained mice. This work improves on those results in extracting and tracking intrinsic features from multiple camera images and computing pose changes from the tracked features over time. Previously, most motion tracking for 3D imaging has been limited to measuring extrinsic features such as retro-reflective markers applied to an animal's head. While this approach has been proven to be accurate, the use of external markers is undesirable for several reasons. The intrinsic feature approach has been further developed from previous work to provide full pose measurements for a live mouse scan. Surface feature extraction, matching, and pose change calculation with point tracking and accuracy results are described. Experimental pose calculation and 3D reconstruction results from live images are presented.

60 APPLIED LIFE SCIENCES↗

Improvements in Intrinsic Feature Pose Measurement for Awake Animal Imaging

Development has continued with intrinsic feature optical motion tracking for awake animal imaging to measure 3D position and orientation (pose) for motion compensated reconstruction. Prior imaging results have been directed towards head motion measurement for SPECT brain studies in awake unrestrained mice. This work improves on those results in extracting and tracking intrinsic features from multiple camera images and computing pose changes from the tracked features over time. Previously, most motion tracking for 3D imaging has been limited to measuring extrinsic features such as retro-reflective markers applied to an animal s head. While this approach has been proven to be accurate, the use of external markers is undesirable for several reasons. The intrinsic feature approach has been further developed from previous work to provide full pose measurements for a live mouse scan. Surface feature extraction, matching, and pose change calculation with point tracking and accuracy results are described. Experimental pose calculation and 3D reconstruction results from live images are presented.

59 BASIC BIOLOGICAL SCIENCES↗