Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Backscatter dose effects for high atomic number materials being irradiated in the presence of a magnetic field: A Monte Carlo study for the MRI linac

Purpose: To quantify and explain the backscatter dose effects for clinically relevant high atomic number materials being irradiated in the presence of a 1.5 T transverse magnetic field. Methods: Interface effects were investigated using Monte Carlo simulation techniques. We used GPUMCD (v5.1) and GEANT4 (v10.1) for this purpose. GPUMCD is a commercial software written for the Elekta AB, MRI linac. Dose was scored using GPUMCD in cubic voxels of side 1 and 0.5 mm, in two different virtual phantoms of dimensions 20 × 20 × 20 cm and 5 × 5 × 13.3 cm, respectively. A photon beam was generated from a point 143.5 cm away from the isocenter with energy distribution sampled from a histogram representing the true Elekta, MRI linac photon spectrum. A slab of variable thickness and position containing either bone, aluminum, titanium, stainless steel, or one of the two different dental filling materials was inserted as an inhomogeneity in the 20 × 20 × 20 cm phantom. The 5 × 5 × 13.3 cm phantom was used as a clinical test case in order to explain the dose perturbation effects for a head and neck cancer patient. The back scatter dose factor (BSDF) was defined as the ratio of the doses at a given depth with and without the presence of the inhomogeneity. Backscattered electron fluence was calculated at the inhomogeneity interface using GEANT4. A 1.5 T magnetic field was applied perpendicular to the direction of the beam in both phantoms, identical to the geometry in the Elekta MRI linac. Results: With the application of a 1.5 T magnetic field, all the BSDF’s were reduced by 12%–47%, compared to the no magnetic field case. The corresponding backscattered electron fluence at the interface was also reduced by 45%–64%. The reduction in the BSDF at the interface, due to the application of the magnetic field, is manifested in a different manner for each material. In the case of bone, the dose drops at the interface contrary to the expected increase when no magnetic field is applied. In the case of aluminum, the dose at the interface is the same with and without the presence of the aluminum. For all of the other materials the dose increases at the interface. Conclusions: The reduction in dose at the interface, in the presence of the magnetic field, is directly related to the reduction in backscattered electron fluence. This reduction occurs due to two different reasons. First, the electron spectrum hitting the interface is changed when the magnetic field is turned on, which results in changes in the electron scattering probability. Second, some electrons that have curved trajectories due to the presence of the magnetic field are absorbed by the higher density side of the interface and no longer contribute to the backscattered electron fluence.

60 APPLIED LIFE SCIENCES↗

Finite boundary effects on the spherical Rayleigh–Taylor instability between viscous fluids

For the Rayleigh–Taylor unstable arrangement of a viscous fluid sphere embedded in a finite viscous fluid spherical shell with a rigid boundary and a radially directed acceleration, a dispersion relation is developed from a linear stability analysis using the method of normal modes. [Formula: see text] is the radially directed acceleration at the interface. ρ i denotes the density, μ i is the viscosity, and R i is the radius, where i = 1 is the inner sphere and i = 2 is the outer sphere. The dispersion relation is a function of the following dimensionless variables: viscosity ratio [Formula: see text], density ratio [Formula: see text], spherical harmonic mode n, [Formula: see text], [Formula: see text], and the dimensionless growth rate [Formula: see text], where σ is the exponential growth rate. We show that the boundedness provided by the outer spherical shell has a strong influence on the instability behavior, which is reflected not only in the modulation of the growth rate but also in the selection of the most unstable modes that are physically possible. This outer boundary effect is quantified by the relative magnitude of the radius ratio H. We find that when H is close to unity, lower order harmonics are excluded from becoming the most unstable within a vast region of the parameter space. In other words, the effect of H has precedence over the other controlling parameters d, B, and a wide range of s in establishing what the lowest most unstable mode can be. When H ~ 1, low order harmonics can become the most unstable only for s >> 1. However, in the limit when s → ∞, we show that the most unstable mode is n = 1 and derive the dispersion relation in this limit. The exclusion of most unstable low order harmonics caused by a finite outer boundary is not realized when the outer boundary extends beyond a certain threshold length-scale in which case all modes are equally possible depending on the value of B.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-F-P-36: Automation of Linear Accelerator Star Shot Measurement with Advanced XML Scripting and Electronic Portal Imaging Device

Purpose: To verify a method used to automatically acquire jaw, MLC, collimator and couch star shots for a Varian TrueBeam linear accelerator utilizing Developer Mode and an Electronic Portal Imaging Device (EPID). Methods: An XML script was written to automate motion of the jaws, MLC, collimator and couch in TrueBeam Developer Mode (TBDM) to acquire star shot measurements. The XML script also dictates MV imaging parameters to facilitate automatic acquisition and recording of integrated EPID images. Since couch star shot measurements cannot be acquired using a combination of EPID and jaw/MLC collimation alone due to a fixed imager geometry, a method utilizing a 5mm wide steel ruler placed on the table and centered within a 15×15cm2 open field to produce a surrogate of the narrow field aperture was investigated. Four individual star shot measurements (X jaw, Y jaw, MLC and couch) were obtained using our proposed as well as traditional film-based method. Integrated EPID images and scanned measurement films were analyzed and compared. Results: Star shot (X jaw, Y jaw, MLC and couch) measurements were obtained in a single 5 minute delivery using the TBDM XML script method compared to 60 minutes for equivalent traditional film measurements. Analysis of the images and films demonstrated comparable isocentricity results, agreeing within 0.3mm of each other. Conclusion: The presented automatic approach of acquiring star shot measurements using TBDM and EPID has proven to be more efficient than the traditional film approach with equivalent results.

60 APPLIED LIFE SCIENCES↗

Detecting Thermally-Induced Spinodal Decomposition with Picosecond Ultrasonics in Cast Austenitic Stainless Steels

Destructive techniques to monitor nuclear reactor component health may not always be available during service, as they are time-consuming and often require pre-installed inspection coupons. Non-destructive evaluation (NDE) techniques can bridge this gap by rapidly identifying the state of mission-critical reactor components, via inference between NDE-measurable material properties and those of ultimate interest, such as ductility and toughness. Here, we demonstrate one such inference about the health of thermally aged cast austenitic stainless steels. Observations of surface acoustic wave peak (SAW) splitting correlate with spinodal decomposition-induced embrittlement as destructively measured by Charpy impact energy. Elastodynamic calculations and molecular dynamics simulations of the effects of spinodal decomposition on elastic moduli support that the new acoustic modes present are due to stiffening in the δ-ferrite domains. Finally, this discovery enables one to probe structure-property relationships in materials in a greatly accelerated manner, suggesting that similar inference methods can be used to determine material fitness-for-service, or to quickly uncover new structure-property relationships.

304-type stainless steel↗

Bridging microscale to macroscale mechanical property measurements of FeCrAl alloys by crystal plasticity modeling

FeCrAl alloys are candidates for accident tolerant fuel cladding of light water reactors. In this work, a microstructure- and temperature-dependent crystal plasticity model is employed to bridge microscale to macroscale mechanical property measurements of FeCrAl alloys. With the visco-plastic self-consistent (VPSC) polycrystal plasticity framework, a mechanism-based single crystal plasticity (MSCP) model adopts the Arrhenius type rate equation to describe the dependence of the critical resolved shear stress for dislocation slips on their temperature-dependent intrinsic frictional resistance and the microstructure-dependent irradiation hardening. The intrinsic frictional resistance associated with {110}<111> and {112}<111> slip systems were measured by in-situ micromechanical testing on unirradiated/irradiated samples at 25-500 °C. The irradiation hardening is estimated by the Bacon-Kocks-Scattergood (BKS) model with density and size of radiation-induced defects measured from microstructural characterization. Several features associated with thermo-mechanical behavior of unirradiated/irradiated polycrystalline FeCrAl alloys are captured. High density of deformation-induced dislocations and radiation-induced defects results in obvious hardening at room temperature, which is weakened at high temperature, and facilitates damage evolution during deformation. Moreover, both high temperature and radiation-induced defects, which facilitate dislocation multiplication, trigger large hardening rate. Finally, the proposed method together with application of accelerator-based ion irradiation technique is a surrogate approach to simulate neutron damage, improving the efficiency associated with evaluation of mechanical properties of FeCrAl alloys exposed to temperature, stress and radiation conditions.

36 MATERIALS SCIENCE↗

A stochastic asymptotic-preserving scheme for a kinetic-fluid model for disperse two-phase flows with uncertainty

In this paper we consider a kinetic-fluid model for disperse two-phase flows with uncertainty. We propose a stochastic asymptotic-preserving (s-AP) scheme in the generalized polynomial chaos stochastic Galerkin (gPC-sG) framework, which allows the efficient computation of the problem in both kinetic and hydrodynamic regimes. The s-AP property is proved by deriving the equilibrium of the gPC version of the Fokker–Planck operator. The coefficient matrices that arise in a Helmholtz equation and a Poisson equation, essential ingredients of the algorithms, are proved to be positive definite under reasonable and mild assumptions. The computation of the gPC version of a translation operator that arises in the inversion of the Fokker–Planck operator is accelerated by a spectrally accurate splitting method. Numerical examples illustrate the s-AP property and the efficiency of the gPC-sG method in various asymptotic regimes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields

The Geant4 toolkit was used to develop a Monte Carlo (MC)-based engine for accurate dose calculations in small radiation field sizes. The Geant4 toolkit (version 10.1.p02) was used to simulate 6-MV photon beam of a Varian2100C linear accelerator that is being used for stereotactic radiosurgery (SRS) treatment with small radiation fields. Geometric models of 3 in-house designed radiosurgical divergent cones, with the diameters of their projections at the isocenter being 10, 20, and 30 mm, were simulated. The accuracy of the MC simulation technique was examined by reproducing several different simulated dosimetric parameters of the primary beams with the experimental data. The dose distributions are first checked for single beams for each cone, then standard multiple field (SMF) techniques are applied. A sample set of DICOM files from computed tomography (CT) scan imaging of a patient's head was converted to the Geant4 geometry format to implement MC-based engine for a clinical test. To validate the accuracy of the MC-based calculations for SMF arrangements, the isodose lines from MC simulation in water phantom were compared with the measured isodose lines using EBT3 Gafchromic film in Solid Water phantoms. Agreements between measured and simulated depth dose values and beam profiles for SRS cones were generally within 2%/2 mm. For output factors, the largest discrepancy was observed for 10 mm SRS cone, which was 1.7%. For SMF techniques, in SRS cones, the MC simulation and EBT3 Gafchromic film dosimetry were in acceptable agreement (5%/5 mm). Excellent agreement between the results of the MC-based and measured dose values for both single and SMF techniques in SRS cones indicates the ability of the Geant4 toolkit to be applied as the platform for treatment planning of advanced radiotherapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

When and how to treat an IMRT patient on a second accelerator without replanning?

When a linear accelerator is unavailable for treatment, a clinical decision is imminent regarding whether a patient should be treated on a linear accelerator other than the machine the patient was scheduled on, or whether treatment should be postponed until the original Linac becomes available. This work investigates the feasibility of switching patients to different accelerators for intensity-modulated radiation therapy (IMRT). We have performed Monte Carlo simulations of photon beams from different Linac models and vendors. Prostate and head and neck (H&N) treatment plans for Siemens Primus, Primart, and Varian 21EX accelerators are studied in this work. Dose distributions for given plans are recalculated using different beam data with the same nominal energy from different Linacs. We have compared dose-volume histograms (DVHs) and the maximum, the minimum, and the mean doses to the target and critical structures because of switching accelerators. In the process of switching a treatment plan to a different accelerator, issues exist, including optimum penumbra compensation, dose distribution at the boundary of target and critical structures, and multileaf collimator (MLC) leaf-width effects, which need to be considered and verified with measurements. Our Monte Carlo simulation results confirm that, for the cases we tested, the dose received by 95% of the planning target volume differs by 0.2% to 1.5% between Siemens Primus and Varian 21EX Linacs. The discrepancy is within our clinical acceptance criteria of 3% for IMRT treatments. In making the final decision on whether to switch machines or not, the tumor control probabilities (TCPs) based on a linear-quadratic model are compared. Based on the analyses performed in this work, it is therapeutically more beneficial to switch a patient to a different machine than to postpone a treatment until the original machine is available, especially for fast-growing tumors such as H&N cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cyberknife stereotactic radiosurgery and radiation therapy treatment planning system

CyberKnife is an image-guided stereotactical dose delivery system designed for both focal irradiation and radiation therapy (SRT). Focal irradiation refers the use of many small beams to deliver highly focus dose to a small target region in a few fractions. The system consists of a 6-MV linac mounted to a robotic arm, coupled with a digital x-ray imaging system. The radiation dose is delivered using many beams oriented at a number of defined or nodal positions around the patients. The CyberKnife can be used for both intracranial and extracranial treaments unlike the Gamma Knife which is limited to intracranial cases. Multiplan (Accuray Inc., Sunnyvale, CA) is the treatment planning system developed to cooperate with this accurate and versatile SRS and SRT system, and exploit the full function of Cyberknife in high-precision radiosurgery and therapy. Optimized inverse treatment plan can be achieved by fine-tuning contours and planning parameters. Precision is the newest version of Cyberknife treatment planning system (TPS) and an upgrade to Multiplan. It offers several new features such as Monte Carlo for multileaf collimator (MLC) and retreatment for other modalities that added more support for the Cyberknife system. The Cybeknife TPS is an easy-to-use and versatile inverse planning platform, suitable for stereotactic radiosurgery and radiation therapy. The knowledge and experience of the planner in this TPS is essential to improve the quality of patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of high throughput screening methods to study dual-functional crosslinkable latexes

Herein, structure-formulation-property relationships for crosslinkable core-shell latexes were studied initially using high throughput screening methods and then using conventional experimental methods to determine optimum coating formulations. Two approaches that are used within coatings technology to improve sustainability are reduction in volatile organic compounds (VOC) and reduction in energy needed to cure coatings. Hybrid crosslinkable core-shell latexes have shown potential in meeting these challenges where film properties provided by particle coalescence are not sufficient and chemical crosslinking is needed. However, with numerous parameters involved such as latex particle architecture, nature and amount of crosslinker, and curing conditions, the screening of formulations via conventional coating testing methods becomes laborious and time-consuming. The results from high-throughput dye extraction and puncture testing were compared to data from conventional testing methods such as chemical resistance (MEK double rubs), pendulum hardness, and tensile testing to identify correlations. The dye extraction results have shown a strong correlation to solvent resistance and pendulum hardness data whereas toughness from puncture testing data correlated to tensile testing. Both high throughput dye extraction and puncture testing methods can be used for the accelerated screening of crosslinkable coating formulations to optimize curing parameters to achieve the best coating performance.

36 MATERIALS SCIENCE↗

NEML2: An efficient and modular multiphysics constitutive modeling library for hybrid computing environments

This paper presents NEML2, an open-source, high-performance library developed for constitutive material modeling, designed to support the flexible and modular development of models for complex material behavior. Building on the foundational structure of its predecessor, NEML, the NEML2 library introduces significant improvements, including enhanced vectorization, automatic differentiation, and seamless integration with PyTorch, facilitating the application of machine learning techniques in material simulations. NEML2 provides a C++ backend with Python bindings, enabling users to create custom material models that can be executed efficiently on both CPU and GPU platforms. The library also supports coupling with Multiphysics simulation frameworks like MOOSE, making it suitable for realistic simulations involving coupled physical processes. Rigorous quality assurance through unit and regression testing ensures the reliability of results, while the extensible, user-friendly design encourages collaboration and reproducibility across the scientific community. This paper provides an overview of NEML2’s architecture, core features, and applications, highlighting its impact on accelerating material qualification and advancing computational methods in materials science.

GPU↗

Intrinsic Li Distribution in Layered Transition-Metal Oxides Using Low-Dose Scanning Transmission Electron Microscopy and Spectroscopy

Understanding Li distribution in layered lithium transition-metal oxide (LiTMO) cathodes in Li-ion batteries has been a major challenge at the atomic scale and nanoscale. Li is extremely difficult to study by transmission electron microscopy (TEM) because the high-energy electrons impart significant energy and cause massive migration. Here, we directly map the intrinsic spatial distribution and bonding of Li in LiNiO 2 -layered cathode materials using low-dose and low-loss electron energy loss spectroscopy (EELS). EELS spectra of the Li–K edge are measured simultaneously with O–K and Ni–L, M 3,2 edges from layered, cation-mixed, and rock-salt phases and directly matched with atomic-resolution scanning TEM images to correlate the changes in peak intensities and positions to the stoichiometry changes with continual loss of Li and O. Changes in the Li content in the LiNiO 2 particles as a function of electron beam dose are studied by sequential Li spectroscopic mapping. We show that the “intrinsic” Li distribution can be observed using a total dose of less than ~1.5 × 10 8 e – nm –2 at an accelerating voltage of 80 kV. The method of nanoscale mapping of Li distribution introduced in this study is applicable to high-Ni LiTMO cathode materials (>89% of Ni) as well as LiNiO 2 . Further study on the extra peaks of the Li–K edge reveals that the peak at ~59 eV is from the Li ions intercalated in between NiO 2 layers barely interacting with each other with less Li K shell electrons pulled to the L shell electrons in NiO 2 . Furthermore, the results shown here provide improved low-loss TEM characterization approaches that can be used to understand the intrinsic fundamental behaviors in Li-ion batteries.

25 ENERGY STORAGE↗

High accuracy barrier heights, enthalpies, and rate coefficients for chemical reactions

Abstract Quantitative chemical reaction data, including activation energies and reaction rates, are crucial for developing detailed kinetic mechanisms and accurately predicting reaction outcomes. However, such data are often difficult to find, and high-quality datasets are especially rare. Here, we use CCSD(T)-F12a/cc-pVDZ-F12// ω B97X-D3/def2-TZVP to obtain high-quality single point calculations for nearly 22,000 unique stable species and transition states. We report the results from these quantum chemistry calculations and extract the barrier heights and reaction enthalpies to create a kinetics dataset of nearly 12,000 gas-phase reactions. These reactions involve H, C, N, and O, contain up to seven heavy atoms, and have cleaned atom-mapped SMILES. Our higher-accuracy coupled-cluster barrier heights differ significantly (RMSE of ∼5 kcal mol −1 ) relative to those calculated at ω B97X-D3/def2-TZVP. We also report accurate transition state theory rate coefficients $${k}_{\infty }(T)$$ k ∞ ( T ) between 300 K and 2000 K and the corresponding Arrhenius parameters for a subset of rigid reactions. We believe this data will accelerate development of automated and reliable methods for quantitative reaction prediction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved scaling of temperature-accelerated dynamics using localization

While temperature-accelerated dynamics (TAD) is a powerful method for carrying out non-equilibrium simulations of systems over extended time scales, the computational cost of serial TAD increases approximately as N{sup 3} where N is the number of atoms. In addition, although a parallel TAD method based on domain decomposition [Y. Shim et al., Phys. Rev. B 76, 205439 (2007)] has been shown to provide significantly improved scaling, the dynamics in such an approach is only approximate while the size of activated events is limited by the spatial decomposition size. Accordingly, it is of interest to develop methods to improve the scaling of serial TAD. As a first step in understanding the factors which determine the scaling behavior, we first present results for the overall scaling of serial TAD and its components, which were obtained from simulations of Ag/Ag(100) growth and Ag/Ag(100) annealing, and compare with theoretical predictions. We then discuss two methods based on localization which may be used to address two of the primary “bottlenecks” to the scaling of serial TAD with system size. By implementing both of these methods, we find that for intermediate system-sizes, the scaling is improved by almost a factor of N{sup 1/2}. Some additional possible methods to improve the scaling of TAD are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct electron acceleration in multi-kilojoule, multi-picosecond laser pulses

The physics mechanism behind the acceleration of electrons to energies much higher than the laser ponderomotive potential is reported. While electrons with these energies have been observed for the last twenty years at the one percent level, it is only with the recent advent of high power lasers with extended pulse durations, large focal spots, and high intensities that significant numbers (>10%) of the so-called “superponderomotive” electrons have been observed. Evidence is provided that the dominant acceleration mechanism of superponderomotive electrons is direct acceleration by the electromagnetic (EM) wave of the laser as they co-propagate in an under-dense plasma; one-dimensional particle-in-cell simulations yield electron spectra with typically ten times the ponderomotive temperature. Direct acceleration requires tens of plasma wavelengths of under-dense plasma, as well as pulse durations of tens of plasma periods, conditions that can be found in large focal spot multi-picosecond laser pulses. It is shown that the plasma simply provides the source of accelerated electrons and a variety of methods to inject a significant population of electrons into the EM waves at relativistic energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Filamentation and focusing of electron beams due to interactions with plasma waves

Results of numerical modeling of the interaction of an electron beam propagating across relativistic plasma waves indicate that electron beam filamentation and focusing may occur under certain conditions. The model is based on solving the relativistic equation of motion in three dimensions for the individual electrons in a tenuous Gaussian beam, as they pass through a relativistic plasma wave. Several electron beam and plasma wave parameters were varied, and the results are summarized. One of the results is that the spacing of the electron beam filaments correlates with the wavelength of the plasma wave. The electron beam filaments appear as vertical slabs after the beam exits the plasma waves. The electron beam also compresses to a focus after it exits the plasma, and the focal distance depends on several parameters including the electron beam energy and phase velocity of the relativistic plasma wave. It is suggested that these focusing and filamentation phenomena may be the basis for diagnostics schemes for laser plasma interactions. The parameters used in the model were electron beam energies in the 5–50 keV range and plasma wave properties typical for the beat-wave produced by CO2 lasers, which correspond to the facilities available in our laboratory. The limitations of these results to lower energy density beam and plasma regimes and to higher energy density regimes will be discussed.

47 OTHER INSTRUMENTATION↗

Advanced data analysis in inertial confinement fusion and high energy density physics

Bayesian analysis enables flexible and rigorous definition of statistical model assumptions with well-characterized propagation of uncertainties and resulting inferences for single-shot, repeated, or even cross-platform data. This approach has a strong history of application to a variety of problems in physical sciences ranging from inference of particle mass from multi-source high-energy particle data to analysis of black-hole characteristics from gravitational wave observations. The recent adoption of Bayesian statistics for analysis and design of high-energy density physics (HEDP) and inertial confinement fusion (ICF) experiments has provided invaluable gains in expert understanding and experiment performance. In this Review, we discuss the basic theory and practical application of the Bayesian statistics framework. We highlight a variety of studies from the HEDP and ICF literature, demonstrating the power of this technique. Due to the computational complexity of multi-physics models needed to analyze HEDP and ICF experiments, Bayesian inference is often not computationally tractable. Two sections are devoted to a review of statistical approximations, efficient inference algorithms, and data-driven methods, such as deep-learning and dimensionality reduction, which play a significant role in enabling use of the Bayesian framework. We provide additional discussion of various applications of Bayesian and machine learning methods that appear to be sparse in the HEDP and ICF literature constituting possible next steps for the community. We conclude by highlighting community needs, the resolution of which will improve trust in data-driven methods that have proven critical for accelerating the design and discovery cycle in many application areas.

47 OTHER INSTRUMENTATION↗