Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Adsorption on transition metal surfaces: Transferability and accuracy of DFT using the ADS41 dataset

We present a benchmarking study of adsorption energies on transition metal surfaces computed with select functionals across different density functional theory codes. In addition to gradient corrected functionals, we evaluate the accuracies of representative metaGGAs, including MS2, SCAN, and SCAN+rVV10 , as well as a short-range screened hybrid functional, HSE06. The study shows that the challenge of finding a functional that can simultaneously capture both covalent and noncovalent molecule-surface interactions persists, with no single functional in the benchmarking study with average errors < 0.2 eV. We find that HSE06 on average does not improve the accuracy compared to PBE for the surface chemistry of transition metals. The BEEF-vdW dispersion-corrected generalized gradient approximation (GGA) and the MS2 metaGGA yield the lowest errors in both chemisorption and dispersion energies, demonstrating that moving up the Jacob's ladder of functionals to screened hybrids does not necessarily improve the description of transition metal surface chemistry.

36 MATERIALS SCIENCE↗

Meta-GGA exchange-correlation free energy density functional to increase the accuracy of warm dense matter simulations

We discuss strategies for thermalization of the ground-state meta-generalized gradient approximation (meta-GGA) exchange-correlation (XC) functionals. A simple but accurate scheme is implemented via universal additive thermal correction to XC using a perturbative-like self-consistent approach. The additive correction with explicit temperature dependence is applied to the ground-state deorbitalized, strongly constrained and appropriately normed (SCAN-L) meta-GGA XC leading to thermal XC functional denoted here as T-SCAN-L. Thermal T-SCAN-L meta-GGA functional shows significant improvement in density functional theory calculation accuracy for warm dense matter by a factor of 3 to 10, achieving unprecedented accuracy of total pressure between a few tenths and 1% when compared to traditional XC functionals, as demonstrated by the comparison to pathintegral Monte Carlo simulations for helium equation of state. Furthermore, the T-SCAN-L calculations of dc conductivity of warm dense aluminum also give better agreement with experiments over other XC functionals such as PBE and SCAN-L.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-accuracy waveforms for black hole-neutron star systems with spinning black holes

The availability of accurate numerical waveforms is an important requirement for the creation and calibration of reliable waveform models for gravitational wave astrophysics. For black hole-neutron star binaries, very few accurate waveforms are however publicly available. Most recent models are calibrated to a large number of older simulations with good parameter space coverage for low-spin non-precessing binaries but limited accuracy, and a much smaller number of longer, more recent simulations limited to non-spinning black holes. In this paper, we present long, accurate numerical waveforms for three new systems that include rapidly spinning black holes, and one precessing configuration. Here, we study in detail the accuracy of the simulations, and in particular perform for the first time in the context of BHNS binaries a detailed comparison of waveform extrapolation methods to the results of Cauchy Characteristic Extraction. The new waveforms have <0.1rad phase errors during inspiral, rising to ~(0.2-0.4)rad errors at merger, and ≲1% error in their amplitude. We compute the faithfulness of recent analytical models to these numerical results, and find that models specifically designed for BHNS binaries perform well (F>0.99) for binaries seen face-on. For edge-on observations, particularly for precessing systems, disagreements between models and simulations increase, and models that include precession and/or higher-order modes start to perform better than BHNS models that currently lack these features.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian inference of fine features of the nuclear equation of state from future neutron star radius measurements to 0.1 km accuracy

To more precisely constrain the equation of state (EOS) of supradense neutron-rich nuclear matter, future high-precision x-ray and gravitational wave observatories are proposed to measure the radii of neutron stars (NSs) with an accuracy better than about 0.1 km. However, it remains unclear what particular aspects (other than the stiffness generally spoken of in the literature) of the EOS and to what precision they will be better constrained. In this work, within a Bayesian framework using a metamodel EOS for NSs, we infer the posterior probability distribution functions (PDFs) of incompressibility K 0 and skewness J 0 of symmetric nuclear matter (SNM) as well as the slope L, curvature K sym , and skewness J sym characterizing the density dependence of nuclear symmetry energy E sym ⁡(ρ), respectively, from mean values of NS radii consistent with existing observations and an expected accuracy Δ⁢R ranging from about 1.0 to 0.1 km. Here, we found that (1) the Δ⁢R has little effect on inferring the stiffness of SNM at suprasaturation densities, (2) smaller Δ⁢R reveals more accurately not only the PDFs but also pairwise correlations among parameters characterizing high-density E sym ⁡(ρ), (3) a double-peak feature of the PDF(K sym ) corresponding to the strong K sym – J sym and K sym – L anticorrelations is revealed when Δ⁢R is less than about 0.2 km, and the locations of the two peaks are sensitive to the maximum value of J sym reflecting the stiffness of E sym ⁡(ρ) above about 3 times the saturation density ρ 0 of SNM, and (4) the high-precision radius measurement for canonical NSs is more useful than that for massive ones for constraining the EOS of nucleonic matter around (2–3)⁢ρ 0 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of a coastal acoustic buoy for cetacean detections, bearing accuracy and exclusion zone monitoring

Abstract There is strong socio‐political support for offshore wind development in US territorial waters and construction is planned off several east coast states. Some of the planned development sites coincide with important habitat for critically endangered North Atlantic right whales. Both exclusion zones and passive acoustic monitoring are important tools for managing interactions between marine mammals and human activities. Understanding where animals are with respect to exclusion zones is important to avoid costly construction delays while minimizing the potential for negative impacts. Impact piling from construction of hundreds of offshore wind turbines likely require exclusion zones as large as 10 km. We have developed a three‐hydrophone passive acoustic monitoring system that provides bearing information along with marine mammal detections to allow for informed management decisions in real‐time. Multiple units form a monitoring system designed to determine whether marine mammal calls originate from inside or outside of an exclusion zone. In October 2021, we undertook a full system validation, with a focus on evaluating the detection range and bearing accuracy of the system with respect to right whale upcalls. Five units were deployed in Mid‐Atlantic waters and we played more than 3500 simulated right whale upcalls at known locations to characterize the detection function and bearing accuracy of each unit. The modelled results of the detection function error were then used to compare the effectiveness of a bearing‐based system to a single sensor that can only detect a signal but not ascertain directivity. Field trials indicated maximum detection ranges from 4–7.3 km depending on source and ambient noise levels. Simulations showed that incorporating bearing detections provide a substantial improvement in false alarm rates (6 to 12 times depending on number of units, placement and signal to noise conditions) for a small increase in the risk of missed detections inside of an exclusion zone (1%–3%). We show that the system can be used for monitoring exclusion zones and clearly highlight the value of including bearing estimation into exclusion zone monitoring plans while noting that placement and configuration of units should reflect anticipated ambient noise conditions.

17 WIND ENERGY↗

Improving precision and accuracy of genetic mapping with genotyping‐by‐sequencing data in outcrossing species

Abstract Genotyping‐by‐sequencing (GBS) is a widely used strategy for obtaining large numbers of genetic markers in model and non‐model organisms. In crop plants, GBS‐derived marker datasets are frequently used to perform quantitative trait locus (QTL) mapping. In some plant species, however, high heterozygosity and complex genome structure mean that researchers must use care in handling GBS data to conduct QTL mapping most effectively. Such outbred crops include most of the perennial grass and tree species used for bioenergy. To identify strategies for increasing accuracy and precision of QTL mapping using GBS data in outbred crops, we conducted an empirical study of SNP‐calling and genetic map‐building pipeline parameters in a Miscanthus sinensis population, and a complementary simulation study to estimate the relationship between genome‐wide error rate, read depth, and marker number. The bioenergy grass Miscanthus is an obligate outcrossing species with a recent (diploidized) whole‐genome duplication. For the study of empirical M. sinensis data, we compared two SNP‐calling methods (one non‐reference‐based and one reference‐based), a series of depth filters (12×, 20×, 30×, and 40×) and two map‐construction methods (i.e., marker ordering: linkage‐only and order‐corrected based on a reference genome). We found that correcting the order of markers on a linkage map by using a high‐quality reference genome improved QTL precision (shorter confidence intervals). For typical GBS datasets of between 1000 and 5000 markers to build a genetic map for biparental populations, a depth filter set at 30× to 40× applied to outbred populations provided a genome‐wide genotype‐calling error rate of less than 1%, improved accuracy of QTL point estimates and minimized type I errors for identifying QTL. Based on these results, we recommend using a reference genome to correct the marker order of genetic maps and a robust genotype depth filter to improve QTL mapping for outbred crops.

59 BASIC BIOLOGICAL SCIENCES↗

Leaf water potential measurements using the pressure chamber: Synthetic testing of assumptions towards best practices for precision and accuracy

Leaf water potential (ψ leaf ), typically measured using the pressure chamber, is the most important metric of plant water status, providing high theoretical value and information content for multiple applications in quantifying critical physiological processes including drought responses. Pressure chamber measurements of ψ leaf (ψ leafPC ) are most typical, yet, the practical complexity of the technique and of the underlying theory has led to ambiguous understanding of the conditions to optimize measurements. Consequently, specific techniques and precautions diversified across the global research community, raising questions of reliability and repeatability. Here, we surveyed specific methods of ψ leafPC from multiple laboratories, and synthesized experiments testing common assumptions and practices in ψ leafPC for diverse species: (i) the need for equilibration of previously transpiring leaves; (ii) leaf storage before measurement; (iii) the equilibration of ψ leaf for leaves on bagged branches of a range of dehydration; (iv) the equilibration of ψ leaf across the lamina for bagged leaves, and the accuracy of measuring leaves with artificially ‘elongated petioles’; (v) the need in ψ leaf measurements for bagging leaves and high humidity within the chamber; (vi) the need to avoid liquid water on leaf surfaces; (vii) the use of ‘pulse’ pressurization versus gradual pressurization; and (viii) variation among experimenters in ψ leafPC determination. Based on our findings we provide a best practice protocol to maximise accuracy, and provide recommendations for ongoing species-specific tests of important assumptions in future studies.

54 ENVIRONMENTAL SCIENCES↗

High-accuracy Aspheric X-ray Mirror Metrology Using Software Configurable Optical Test System/deflectometry

The Software Configurable Optical Test System (SCOTS) uses deflectometry to measure surface slopes of general optical shapes without the need for additional null optics. Careful alignment of test geometry and calibration of inherent system error improve the accuracy of SCOTS to a level where it competes with interferometry. We report a SCOTS surface measurement of an off-axis superpolished elliptical x-ray mirror that achieves <1 nm<1 nm root-mean-square accuracy for the surface measurement with low-order term included.

42 ENGINEERING↗

The ALS OSMS: Optical Surface Measuring System for high accuracy two-dimensional slope metrology with state-of-the-art x-ray mirrors

We report that to preserve the brightness and coherence of x-rays produced by diffraction-limited-storage-ring (DLSR) and free-electron laser (FEL) light sources, beamline optics must have unprecedented quality. For example, in the case of the most advanced beamlines for the DLSR source under development at the Advanced Light Source (ALS), the ALS-U, we need highly curved x-ray mirrors with surface slope tolerances better than 50-100 nrad (root-mean-square, rms). At the ALS X-Ray Optics Lab (XROL), we are working on the development of a new Optical Surface Measuring System (OSMS) with the required measurement accuracy. The OSMS is capable for the two-dimensional (2D) surface slope metrology over the spatial range from the sub-mm scale to the clear aperture. Usage of different arrangements of the OSMS sensors allows measuring the mirrors in the face-up or side-facing orientation, corresponding to the beamline application. The OSMS translation system and data acquisition software are designed to support multi scan measurement runs optimized for automatic suppression and compensation of instrumental drifts and major angular and spatial systematic errors. Here, we discuss the recent results of the OSMS research and development project. We provide details of the OSMS design and describe results of experimental performance tests of the gantry system. In particular, we show that the system is capable for measurement repeatability with strongly curved mirrors on the level of 20 nrad (rms). The high angular resolution of the OSMS rotational tip-tilt stage is adequate for implementation of instrumental calibration with using the mirror under test as a reference. The achieved measuring accuracy is demonstrated via comparison to metrology with the carefully calibrated Developmental Long Trace Profiler, also available at the XROL.

47 OTHER INSTRUMENTATION↗

Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes

Purpose: Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have been developed to calibrate the scaling accuracy of micro-CT scanners to a traceable standard and provide corrections to image voxel sizing. Methods: The calibration phantom contains six borosilicate beads whose separations have been measured to a traceable standard. An image processing algorithm compares the known separations of the beads to their separations in micro-CT images. A least-squares solution is used to determine linear scaling correction factors along each of the three scanner axes to minimize errors in the bead separations within the images by correcting the image voxel size. The correction factors were applied to images of a similar phantom with beads at different positions to evaluate the ability of the correction factors to reduce errors at points independent of the fiducial locations in the calibration phantom. The calibration phantom was used to evaluate the scaling accuracy of five different micro-CT scanners representing four different scanner models. Results: In two of the five scanners evaluated, the correction factors significantly reduced the mean error in bead separations in the images from 0.17% to 0.05% and from 0.37% to 0.07% of the actual bead separations, respectively. Scanners yielding similar voxel sizes possessed comparable geometric errors after correction using the phantom. Conclusions: Although the magnitude of the corrections is small, such corrections can be important for demanding micro-CT applications. Even if no voxel size correction is required, the phantom provides an easily implemented method to verify the geometric fidelity of micro-CT scanners to a traceable standard of measurement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-433: Calibration Accuracy in Mailed High-Resolution 3D Dosimetry Service for SRS/SBRT QA

Purpose: SRS/SBRT combines hypofractionation with excellent dose distributions. However, extremely steep gradients across the target along with dose escalation, if not administered accurately, may lead to serious complications, recurrences, or even fatalities. Existing commercial QA products either lack adequate spatial resolution or the 3D aspect. By contrast, the new CrystalBall™ mailed high-resolution 3D dosimetry service removes the above limitations while reducing the overall workload on medical physics staff. The exposed dosimeters, which change optical density in proportion to local dose, are sent back to the manufacturer (MGS Research Inc., Madison, CT) for sub-millimeter-resolution laser-CT scanning and QA data analysis. QA report is returned electronically within 24 hours. The purpose of this study was to evaluate the dose calibration accuracy in this system. Methods: Two spherical CrystalBall™ polymer gel dosimeters from the same batch, 166 mm diameter, with embedded 3D image registration markers, were mounted in a special phantom designed for reproducible positioning. For full end to end testing, the optical guidance array was mounted onto the phantom and a CT was taken. Two separate Rapid Arc SRS plans were designed. Varian Medical Systems optical guidance system was used to position the phantom and the SRS treatment plans were delivered to the two spheres on Varian's Trilogy Accelerator. Exposed dosimeters were mailed back to the manufacturer for laser CT scanning and analysis. Results: For each plan, 3D gamma passing rate was 100% for 2%/2mm distance-to-agreement criteria above 50% isodose level. The two calibration curves, generated using volumetric dose and optical density data, showed excellent mutual agreement (max difference 2.2%, median difference 0.75%). Conclusion: The clinical utility of new CrystalBall™ mailed QA service for SRS/SBRT and high accuracy of dose calibration have been validated. The workflow associated with the use of the CrystalBall™ in clinical setting was found to be minimal. The presenting author is the founder of and has an ownership in MGS Research Inc which manufactures the CrystalBall system for 3D dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lack of robustness and accuracy of many numerical schemes for phase-field simulations

In this paper, we study the stability, accuracy and convergence behavior of various numerical schemes for phase-field modeling through a simple ODE model. Both theoretical analysis and numerical experiments are carried out on this ODE model to demonstrate the limitation of most numerical schemes that have been used in practice. One main conclusion is that the first-order fully implicit scheme is the only robust algorithm for phase-field simulations while all other schemes (that have been analyzed) may have convergence issue if the time step size is not exceedingly small. More specifically, by rigorous analysis in most cases, we have the following conclusions: (i) The first-order fully implicit scheme converges to the correct steady state solution for all time step sizes. In the case of multiple solutions, one of the solution branches always converges to the correct steady state solution. (ii) The first-order convex splitting scheme, which is equivalent to the first-order fully implicit scheme with a different time scaling, always converges to the correct steady state solution but may seriously lack numerical accuracy for transient solutions. (iii) For the second-order fully implicit and convex splitting schemes, for any time step size $δt > 0$, there exists an initial condition $u_0$ , with $|u_0| > 1$, such that the numerical solution converges to the wrong steady state solution. (iv) For $|u_0|$ ≤ 1, all second-order schemes studied in this paper converge to the correct steady state solution although severe numerical oscillations occur for most of them if the time step size is not sufficiently small. (v) An unconditionally energy-stable scheme (such as the modified Crank–Nicolson scheme) is not necessarily better than a conditionally energy-stable scheme (such as the Crank–Nicolson scheme). Finally, most, if not all, of the above conclusions are expected to be true for more general Allen–Cahn and other phase-field models.

97 MATHEMATICS AND COMPUTING↗

Improving Solution Accuracy and Convergence for Stochastic Physics Parameterizations with Colored Noise

Stochastic parameterizations are used in numerical weather prediction and climate modeling to help capture the uncertainty in the simulations and improve their statistical properties. Convergence issues can arise when time integration methods originally developed for deterministic differential equations are applied naively to stochastic problems. In previous studies, it has been demonstrated that a correction term, known in stochastic analysis as the Itô correction, can help improve solution accuracy for various deterministic numerical schemes and ensure convergence to the physically relevant solution without substantial computational overhead. The usual formulation of the Itô correction is valid only when the stochasticity is represented by white noise. In this study, a generalized formulation of the Itô correction is derived for noises of any color. The formulation is applied to a test problem described by an advection–diffusion equation forced with a spectrum of fast processes. We present numerical results for cases with both constant and spatially varying advection velocities to show that, for the same time step sizes, the introduction of the generalized Itô correction helps to substantially reduce time integration error and significantly improve the convergence rate of the numerical solutions when the forcing term in the governing equation is rough (fast varying); alternatively, for the same target accuracy, the generalized Itô correction allows for the use of significantly longer time steps and, hence, helps to reduce the computational cost of the numerical simulation.

54 ENVIRONMENTAL SCIENCES↗

DISTEMA: distance map-based estimation of single protein model accuracy with attentive 2D convolutional neural network

Abstract Background Estimation of the accuracy (quality) of protein structural models is important for both prediction and use of protein structural models. Deep learning methods have been used to integrate protein structure features to predict the quality of protein models. Inter-residue distances are key information for predicting protein’s tertiary structures and therefore have good potentials to predict the quality of protein structural models. However, few methods have been developed to fully take advantage of predicted inter-residue distance maps to estimate the accuracy of a single protein structural model. Result We developed an attentive 2D convolutional neural network (CNN) with channel-wise attention to take only a raw difference map between the inter-residue distance map calculated from a single protein model and the distance map predicted from the protein sequence as input to predict the quality of the model. The network comprises multiple convolutional layers, batch normalization layers, dense layers, and Squeeze-and-Excitation blocks with attention to automatically extract features relevant to protein model quality from the raw input without using any expert-curated features. We evaluated DISTEMA’s capability of selecting the best models for CASP13 targets in terms of ranking loss of GDT-TS score. The ranking loss of DISTEMA is 0.079, lower than several state-of-the-art single-model quality assessment methods. Conclusion This work demonstrates that using raw inter-residue distance information with deep learning can predict the quality of protein structural models reasonably well. DISTEMA is freely at https://github.com/jianlin-cheng/DISTEMA

59 BASIC BIOLOGICAL SCIENCES↗

Simultaneously improving accuracy and computational cost under parametric constraints in materials property prediction tasks

Abstract Modern data mining techniques using machine learning (ML) and deep learning (DL) algorithms have been shown to excel in the regression-based task of materials property prediction using various materials representations. In an attempt to improve the predictive performance of the deep neural network model, researchers have tried to add more layers as well as develop new architectural components to create sophisticated and deep neural network models that can aid in the training process and improve the predictive ability of the final model. However, usually, these modifications require a lot of computational resources, thereby further increasing the already large model training time, which is often not feasible, thereby limiting usage for most researchers. In this paper, we study and propose a deep neural network framework for regression-based problems comprising of fully connected layers that can work with any numerical vector-based materials representations as model input. We present a novel deep regression neural network, iBRNet, with branched skip connections and multiple schedulers, which can reduce the number of parameters used to construct the model, improve the accuracy, and decrease the training time of the predictive model. We perform the model training using composition-based numerical vectors representing the elemental fractions of the respective materials and compare their performance against other traditional ML and several known DL architectures. Using multiple datasets with varying data sizes for training and testing, We show that the proposed iBRNet models outperform the state-of-the-art ML and DL models for all data sizes. We also show that the branched structure and usage of multiple schedulers lead to fewer parameters and faster model training time with better convergence than other neural networks. Scientific contribution: The combination of multiple callback functions in deep neural networks minimizes training time and maximizes accuracy in a controlled computational environment with parametric constraints for the task of materials property prediction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy of Fukuoka and American Gastroenterological Association Guidelines for Predicting Advanced Neoplasia in Pancreatic Cyst Neoplasm: A Meta-Analysis

Background: A differential diagnosis of advanced pancreatic cystic neoplasms (PCNs) is critical to determine optimal treatment. The Fukuoka and American Gastroenterological Association (AGA) guidelines are the most widely accepted criteria for the management of PCNs. Objective: This study aimed to evaluate the diagnostic value of these guidelines in predicting advanced neoplasia (AN). Methods: A comprehensive electronic search of the PubMed, EMBASE, Web of Science, Cochrane Library, and Scopus databases was conducted to identify all relevant studies evaluating the Fukuoka and AGA guidelines in surgically resected and histologically confirmed PCNs. Pooled sensitivity, specificity, and diagnostic odds ratios (DORs) were calculated as compound measures of diagnostic accuracy using the random-effects model. Summary of receiver operating characteristic (SROC) curves and the area under the curve (AUC) were also performed. Results: A total of 21 studies with 3723 patients were included in this meta-analysis. Of these studies, 15, 4, and 2 evaluated the Fukuoka guidelines, the AGA guidelines, and both guidelines, respectively. For AN prediction, the Fukuoka guidelines had a pooled sensitivity of 0.67 (95% confidence interval [CI] 0.64–0.70), pooled specificity of 0.64 (95% CI 0.62–0.66), and pooled DOR of 6.28 (95% CI 4.38–9.01), with an AUC of the SROC of 0.78. AGA guidelines showed a pooled sensitivity of 0.59 (95% CI 0.52–0.65), pooled specificity of 0.77 (95% CI 0.74–0.80), and pooled DOR of 5.84 (95% CI 2.60–13.15), with an AUC of 0.79 (95% CI 0.70–0.88). Conclusion: When used alone, the Fukuoka and AGA guidelines showed similar but unsatisfactory diagnostic accuracy in the risk stratification of malignant potential of PCN. Thus, we recommend that they be applied only as a broad framework in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Digital holography simulations and experiments to quantify the accuracy of 3D particle location and 2D sizing using a proposed hybrid method

The accuracy of digital in-line holography to detect particle position and size within a 3D domain is evaluated with particular focus placed on detection of nonspherical particles. Dimensionless models are proposed for simulation of holograms from single particles, and these models are used to evaluate the uncertainty of existing particle detection methods. From the lessons learned, a new hybrid method is proposed. This method features automatic determination of optimum thresholds, and simulations indicate improved accuracy compared to alternative methods. To validate this, experiments are performed using quasi-stationary, 3D particle fields with imposed translations. For the spherical particles considered in experiments, the proposed hybrid method resolves mean particle concentration and size to within 4% of the actual value, while the standard deviation of particle depth is less than two particle diameters. Initial experimental results for nonspherical particles reveal similar performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High accuracy single-layer free-space diffractive neuromorphic classifiers for spatially incoherent light

Free-space all-optical diffractive systems have shown promise for neuromorphic classification of objects without converting light to the electronic domain. While the factors that govern these systems have been studied for coherent light, the fundamental properties for incoherent light have not been addressed, despite the importance for many applications. Here we use a co-design approach to show that optimized systems for spatially incoherent light can achieve performance on par with the best linear electronic classifiers even with a single layer containing few diffractive features. This performance is limited by the inherent linear nature of incoherent optical detection. We circumvent this limit by using a differential detection scheme that achieves greater than 94% classification accuracy on the MNIST dataset and greater than 85% classification accuracy for Fashion-MNIST, using a single layer metamaterial.

Léonard, François (ORCID:0000000249736743)↗