Modifications of the X-ray source and monitor at the X-ray Calibration Facility

In order to test the instruments aboard the Advanced X-ray Astrophysics Facility (AXAF) some modifications will need to be made in the X-ray Calibration Facility at Marshall. Several of these modifications involve the X-ray source and the monitor. The source was redesigned to increase the spectral purity of the beam and decrease its polarization by minimizing the number of bremsstrahlung photons in the beam. This was accomplished by utilizing an annular electron gun which allowed the beam to take off antiparallel to the direction at which electrons are incident on the anode. Two other features of the source are the conical anode which decreases the effective spot size and a rotatable anode and filter wheel which allow the operator to change targets without breaking vacuum. The monitor is an important part of the facility because it is used to determine the X-ray flux at the target. A commercially available solid-state detector, Si(Li), should be used along with appropriate proportional counters for monitoring. This detector will be particularly useful when energy or wavelength dispersive instruments are tested because of its good resolution.

Newbolt, W. Barlow↗

NEET Enhanced Micro-Pocket Fission Detector for High Temperature Reactors - FY16 Status Report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core fission chambers and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for year two of this three year project. Highlights from research accomplishments include: • Continuation of a joint collaboration between INL, KSU, and CEA. Note that CEA is participating at their own expense because of interest in this unique new sensor. • An updated parallel wire HT MPFD design was developed. • Program support for HT MPFD deployments was given to Accident Tolerant Fuels (ATF) and Advanced Gas-cooled Reactor (AGR) irradiation test programs. • Quality approved materials for HT MPFD construction were procured by irradiation test programs for upcoming deployments. • KSU improved and performed electrical contact and fissile material plating. • KSU delivered fissile HT MPFD parts to INL for final construction of HT MPFD prototype. • A prototype HT MPFD was constructed and analyzed at INL. • The HT MPFD has been modeled in MCNP to optimize the amount of fissile material deposition. • The HT MPFD has been modeled in MCNP to optimize the sensor location in the irradiation test. • The fissile material deposition is undergoing independent verifications. • Detector amplifier electronics have been revised and tested by KSU. • Several project meetings were held at INL and KSU to discuss the roles and responsibilities between INL, KSU, and CEA for development and deployment of the HT MPFDs. As documented in this report, FY16 funding has allowed the project to meet year two planned accomplishments to develop a HT MPFD. In addition, the accomplishments of this project have attracted independent funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for MTR irradiations of the MPFD technology. These are significant opportunities for this NEET Enhanced Micro-Pocket Fission Detector for High Temperature Reactors project because the irradiation expense of these experiments could not be included in the original project scope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of WIRE-21 SPND and Optical Fiber Sensor Measurements

The Wireless Instrumented RB Experiment 2021 (WIRE-21) was a highly instrumented experiment designed to test prototype wireless temperature and pressure sensors developed by Westinghouse Electric Corporation (WEC) in the High Flux Isotope Reactor (HFIR). In addition to these sensors, a suite of other sensors was also integrated into the experiment capsule, including various types of distributed optical fiber sensors and self-powered neutron detectors (SPNDs). This report presents an analysis of the data generated by the SPNDs and optical fiber sensors that were tested under the highest reported neutron flux. The distributed optical fiber sensor results demonstrate that F-doped optical fibers, particularly those inscribed with fs fiber Bragg gratings (FBGs), are capable of surviving fast neutron fluences on the order of 1021 n fast /cm 2 at temperatures relevant to light-water reactors (between 200 and 400°C). However, a significant blue-shift in the optical spectra of these sensors was observed over the course of irradiation which cannot be explained based on the current understanding of radiation-induced compaction in fused silica glass. A mechanistic understanding of this drift has not yet been developed and is proposed as future scope under the Advanced Sensors and Instrumentation program. Of the four SPNDs, only one appeared to operate normally during three cycles of irradiation. A radiation transport model of the experiment in HFIR was used to determine time-dependent neutron flux in this SPND and to calculate the neutron sensitivity of the device. Results showed a cycle averaged sensitivity of 1.5 ×10 -22 and 1.4 ×10 -22 A/nν for the first and third cycles of irradiation, respectively. Additional details pertaining to the optical fibers and SPNDs are included herein.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The ARENA Test Bed – A Versatile Resource for I&C Development and Validation

The Accelerated and Real-time Experimental Nodal Assessment (ARENA) Test Bed at the Pacific Northwest National Laboratory (PNNL) is a versatile resource for development and validation of instrumentation and control (I&C) technologies. This capability was created to facilitate in-situ testing of nuclear electrical cables in various simulated operational environments. Using cable trays, a control box, and selected test components, low voltage cables can be staged to experience local adverse environments such as elevated temperature and water immersion. Cable condition can be continuously monitored over time to track the effect of local stresses using nondestructive assessment tools. A heads-up display (ARENA TV) plots key data in real-time for users. The ARENA Test Bed has recently been used to evaluate the potential for spread spectrum time domain reflectometry (SSTDR) to monitor thermal aging of a portion of live cable powering a three-phase motor. The arrangement provided the opportunity to directly compare the performance of the novel online SSTDR method with offline results from the more standard frequency domain reflectometry (FDR) method. The ability of SSTDR and FDR to identify the presence of water in immersed shielded and unshielded cables and to detect ground faults was also assessed. A digital twin is being developed to track and predict FDR signals from a thermally aging conceptual cable region to compare with measured signals from the ARENA physical counterpart. The test bed concept addresses an important need in nuclear I&C monitoring tool development. New tools and techniques can be developed in the test bed and validated versus known methods and physical measurements. Digital twins and machine learning engines can be populated with measured data in a controlled environment that would not be readily available in the actual nuclear power plant. Proposed monitoring strategies can be confirmed for effectiveness through objective evaluation. It is anticipated that the PNNL ARENA Test Bed will be a valuable resource in advancing nuclear plant instrumentation.

nuclear electrical cables, ARENA Test Bed, conditi↗

Advancing the sensitivity of selected reaction monitoring-based targeted quantitative proteomics

Selected reaction monitoring (SRM)—also known as multiple reaction monitoring (MRM)—has emerged as a promising high-throughput targeted protein quantification technology for candidate biomarker verification and systems biology applications. A major bottleneck for current SRM technology, however, is insufficient sensitivity for e.g., detecting low-abundance biomarkers likely present at the pg/mL to low ng/mL range in human blood plasma or serum, or extremely low-abundance signaling proteins in the cells or tissues. Herein we review recent advances in methods and technologies, including front-end immunoaffinity depletion, fractionation, selective enrichment of target proteins/peptides or their posttranslational modifications (PTMs), as well as advances in MS instrumentation, which have significantly enhanced the overall sensitivity of SRM assays and enabled the detection of low-abundance proteins at low to sub- ng/mL level in human blood plasma or serum. General perspectives on the potential of achieving sufficient sensitivity for detection of pg/mL level proteins in plasma are also discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Materials Applications of Photoelectron Emission Microscopy

Photoelectron emission microscopy (PEEM) is a versatile technique that can image a variety of materials including metals, semiconductors and even insulators. Under favorable conditions the most advanced aberration corrected instruments have a spatial resolution approaching 2 nm. Although PEEM cannot compete with transmission or scanning electron microscopies for ultimate resolution, the technique is much more gentle and has the unique advantage of imaging structure as well as electronic and magnetic states on the nanoscale. Since the image contrast is derived from spatial variations in electron photoemission intensity, PEEM is ideal for interrogating both static and dynamic electronic properties of complex nanostructured materials. PEEM can be performed using a variety of photoexcitation sources including synchrotron emission, femtosecond laser pulses and conventional UV lamp emission. Each source has advantages, for example, fs laser excitation enables time-resolved imaging for study of ultrafast dynamics of surface intermediate states while tunable synchrotron sources allow chemically specific excitation. Even more detail can be extracted from energy resolved PEEM. Here, we review the key principles and contrast mechanisms of PEEM and briefly summarize materials applications of PEEM with examples of a thermally-induced structural phase transformation in barium titanate, inter-diffusion between thin metal copper and ruthenium layers, and multiphoton imaging of polystyrene nanoparticles on a silver coated substrate.

43 PARTICLE ACCELERATORS↗

An Optimized Informatics Pipeline for Mass Spectrometry-Based Peptidomics

Comprehensive MS analysis of peptidome, the intracellular and intercellular products of protein degradation, has the potential to provide novel insights on endogenous proteolytic processing and their utility in disease diagnosis and prognosis. Along with the advances in MS instrumentation, a plethora of proteomics data analysis tools have been applied for direct use in peptidomics; however an evaluation of the currently available informatics pipelines for peptidomics data analysis has yet to be reported. In this study, we set off by evaluating the results of several popular MS/MS database search engines including MS-GF+, SEQUEST and MS-Align+ for peptidomics data analysis, followed by identification and label-free quantification using the well-established accurate mass and time (AMT) tag and newly developed informed quantification (IQ) approaches, both based on direct LC-MS analysis. Our result demonstrated that MS-GF+ outperformed both SEQUEST and MS-Align+ in identifying peptidome peptides. Using a database established from the MS-GF+ peptide identifications, both the AMT tag and IQ approaches provided significantly deeper peptidome coverage and less missing value for each individual data set than the MS/MS methods, while achieving robust label-free quantification. Besides having an excellent correlation with the AMT tag quantification results, IQ also provided slightly higher peptidome coverage than AMT. Taken together, we propose an optimal informatics pipeline combining MS-GF+ for initial database searching with IQ (or AMT) for identification and label-free quantification for high-throughput, comprehensive and quantitative peptidomics analysis.

Environmental Molecular Sciences Laboratory↗

A Pair Production Telescope for Medium-Energy Gamma-Ray Polarimetry

We describe the science motivation and development of a pair production telescope for medium-13 energy gamma-ray polarimetry. Our instrument concept, the Advanced Energetic Pair Telescope 14 (AdEPT), takes advantage of the Three-Dimensional Track Imager, a low-density gaseous time 15 projection chamber, to achieve angular resolution within a factor of two of the pair production 16 kinematics limit (~0.6° at 70 MeV), continuum sensitivity comparable with the Fermi-LAT front 17 detector (<3×10-6 MeV cm-2 s-1 at 70 MeV), and minimum detectable polarization less than 10% 18 for a 10 millicrab source in 106 seconds.

Hunter, Stanley D.↗

Addition of transient kinetics capabilities to an infrared reflection absorption spectroscopy system through synchronized gas pulsing and data acquisition

Surface science methodologies for understanding thermodynamic aspects of surface processes are at an advanced level. However, instrumentation and approaches for extracting kinetic parameters from elementary steps are far less accessible. In this work, we present an approach combining the use of a fast gas pulsing valve synchronized with data acquisition to enable surface transient kinetics studies using infrared reflection absorption spectroscopy. This methodology applies to the study of reversible processes and borrows concepts and ideas from molecular beam scattering and temporal analysis of products. Here, a temporal resolution of ~67 ms is achieved, and this is illustrated through the study of CO adsorption and desorption on a Pd(111) crystal in the presence and absence of background O 2 . The same approach can be extended to other surface spectroscopies, such as X-ray photoelectron spectroscopy, to obtain spectra with high temporal resolution and signal-to-noise ratio and enable future multimodal surface transient kinetic studies aiming at elucidating reaction mechanisms.

36 MATERIALS SCIENCE↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geophysical Monitoring of Moisture-Induced Landslides: A Review

Geophysical monitoring of landslides can provide insights into spatial and temporal variations of subsurface properties associated with slope failure. Recent improvements in equipment, data analysis, and field operations have led to a significant increase in the use of such techniques in monitoring. Geophysical methods complement intrusive approaches, which sample only a very small proportion of the subsurface, and walk-over or remotely sensed data, which principally provide information only at the ground surface. In particular, recent studies show that advances in geophysical instrumentation, data processing, modeling, and interpretation in the context of landslide monitoring are significantly improving the characterization of hillslope hydrology and soil and rock hydrology and strength and their dynamics over time. This review appraises the state of the art of geophysical monitoring, as applied to moisture-induced landslides. Here we focus on technical and practical uses of time-lapse methods in geophysics applied to monitoring moisture-induced landslide. The case studies identified in this review show that several geophysical techniques are currently used in the monitoring of subsurface landslide processes. These geophysical contributions to monitoring and predicting the evolution of landslide processes are currently underrealized. Hence, the further integration of multiple-parametric and geotechnically coupled geophysical monitoring systems has considerable potential. The complementary nature of certain methods to map the distribution of subsurface moisture and elastic moduli will greatly increase the predictive and monitoring capacity of early warning systems in moisture-induced landslide settings.

58 GEOSCIENCES↗

Autonomous closed-loop mechanistic investigation of molecular electrochemistry via automation

Abstract Electrochemical research often requires stringent combinations of experimental parameters that are demanding to manually locate. Recent advances in automated instrumentation and machine-learning algorithms unlock the possibility for accelerated studies of electrochemical fundamentals via high-throughput, online decision-making. Here we report an autonomous electrochemical platform that implements an adaptive, closed-loop workflow for mechanistic investigation of molecular electrochemistry. As a proof-of-concept, this platform autonomously identifies and investigates an EC mechanism, an interfacial electron transfer ( E step) followed by a solution reaction ( C step), for cobalt tetraphenylporphyrin exposed to a library of organohalide electrophiles. The generally applicable workflow accurately discerns the EC mechanism’s presence amid negative controls and outliers, adaptively designs desired experimental conditions, and quantitatively extracts kinetic information of the C step spanning over 7 orders of magnitude, from which mechanistic insights into oxidative addition pathways are gained. This work opens opportunities for autonomous mechanistic discoveries in self-driving electrochemistry laboratories without manual intervention.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new ion sensing deep atomic force microscope

Here we describe a new deep atomic force microscope (AFM) capable of ion sensing. A novel probe assembly incorporates a micropipette that can be used both for sensing ion currents and as the tip for AFM imaging. The key advance of this instrument over previous ion sensing AFMs is that it uses conventional micropipettes in a novel suspension system. This paper focuses on sensing the ion current passively while using force feedback for the operation of the AFM in contact mode. Two images are obtained simultaneously: (1) an AFM topography image and (2) an ion current image. As an example, two images of a MEMS device with a microchannel show peaks in the ion current as the pipette tip goes over the edges of the channel. This ion sensing AFM can also be used in other modes including tapping mode with force feedback as well as in non-contact mode by utilizing the ion current for feedback, as in scanning ion conductance microscopy. The instrument is gentle enough to be used on some biological samples such as plant leaves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in high-resolution RIXS for the study of excitation spectra under high pressure

Hard x-ray resonant inelastic x-ray scattering (RIXS) is a promising x-ray spectroscopic tool for measuring low-energy excitation spectra at high pressure which have been stymied heretofore by the technical difficulties inherent in measuring a sample held at high pressure in a diamond anvil cell. The currently available facilities of high resolution (< 200 meV) RIXS has been used to probe low-energy excitation spectra from the diamond anvil cell, by virtue of advanced photon detection instrumentations of high-brilliance synchrotron x-ray radiation sources. Compared to a structural elastic scattering and x-ray emission, RIXS is a photon hungry technique and high-resolution RIXS under high pressure is at its infancy stage. In this review, the fundamentals of RIXS including instrumentation of high-resolution RIXS are presented and then experimental details of diamond anvil cell, sample preparation and measurement geometry are discussed. Experimental data of 3d and 5d transition metal oxides are presented. Finally, future improvements in high-resolution RIXS instrumentation for the high pressure experiment is discussed.

electronic and magnetic excitations↗

MAGNETIC FIELD-LINE LENGTHS IN INTERPLANETARY CORONAL MASS EJECTIONS INFERRED FROM ENERGETIC ELECTRON EVENTS

About one quarter of the observed interplanetary coronal mass ejections (ICMEs) are characterized by enhanced magnetic fields that smoothly rotate in direction over timescales of about 10-50 hr. These ICMEs have the appearance of magnetic flux ropes and are known as 'magnetic clouds' (MCs). The total lengths of MC field lines can be determined using solar energetic particles of known speeds when the solar release times and the 1 AU onset times of the particles are known. A recent examination of about 30 near-relativistic (NR) electron events in and near 8 MCs showed no obvious indication that the field-line lengths were longest near the MC boundaries and shortest at the MC axes or outside the MCs, contrary to the expectations for a flux rope. Here we use the impulsive beamed NR electron events observed with the Electron Proton and Alpha Monitor instrument on the Advanced Composition Explorer spacecraft and type III radio bursts observed on the Wind spacecraft to determine the field-line lengths inside ICMEs included in the catalog of Richardson and Cane. In particular, we extend this technique to ICMEs that are not MCs and compare the field-line lengths inside MCs and non-MC ICMEs with those in the ambient solar wind outside the ICMEs. No significant differences of field-line lengths are found among MCs, ICMEs, and the ambient solar wind. The estimated number of ICME field-line turns is generally smaller than those deduced for flux-rope model fits to MCs. We also find cases in which the electron injections occur in solar active regions (ARs) distant from the source ARs of the ICMEs, supporting CME models that require extensive coronal magnetic reconnection with surrounding fields. The field-line lengths are found to be statistically longer for the NR electron events classified as ramps and interpreted as shock injections somewhat delayed from the type III bursts. The path lengths of the remaining spike and pulse electron events are compared with model calculations of solar wind field-line lengths resulting from turbulence and found to be in good agreement.

79 ASTRONOMY AND ASTROPHYSICS↗