Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHECK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Initial tests of large format sensors for the ATLAS ITk strip tracker

For the construction of the Inner Tracker (ITk) as part of the phase-II upgrade programme of the ATLAS detector for the High-Luminosity (HL) LHC, batches of Long Strip (LS) and Short Strip (SS) n + -in-p type micro-strip sensors have been produced by Hamamatsu Photonics and Infineon. The full size sensors measure approximately 98 × 98 mm 2 and are designed and engineered for tolerance against the 9.7 × 10 14 1 MeV n eq /cm 2 fluence expected at the HL-LHC, including a safety factor of 1.5. Each sensor has 2 or 4 columns of 1280 individual channels arranged at 75.5 μ m horizontal pitch. To ensure the sensors comply with their specifications, a Quality Control (QC) procedure has been implemented, comprising measurements on every individual sensor as well as on a sample basis. Every sensor is subjected to an initial visual inspection, after which the full surface of the sensor is captured with very high resolution by an automated camera setup. Non-contact metrology is performed to obtain the sensor surface profile. Electrical measurements establishing the reverse bias leakage current and depletion voltage are then conducted automatically. Sample sensors from every batch are subjected to 40 h of leakage stability checks in controlled atmosphere, and tests on every channel measuring leakage current, coupling capacitance and bias resistance are done. The recorded results are uploaded to a production database following data quality checks. In this paper, QC test validation data and the compiled results for the first batches of production grade sensors are presented. The QC protocol was validated, and the first production sensors were confirmed to be within specification. The results are compared to those from the previous generation of prototype sensors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Why matter effects matter for JUNO

In this paper we focus on the Earth matter effects for the solar parameter determination by a medium baseline reactor experiment such as JUNO. We derive perturbative expansions for the mixing angles θ 12 and θ 13 as well as the Δm$^{2}_{21}$ and Δm$^{2}_{31}$ in terms of the matter potential relevant for JUNO. These expansions, up to second order in the matter potential, while simple, allow one to calculate the electron antineutrino survival probability to a precision much better than needed for the JUNO experiment. We use these perturbative expansions to semi-analytically explain and confirm the shift caused by the matter effects on the solar neutrino mixing parameters θ 12 and Δm$^{2}_{21}$ which were previously obtained by a purely numerical χ 2 analysis. Since these shifts do not satisfy the naive expectations and are significant given the precision that can be achieved by the JUNO experiment, a totally independent cross check using a completely different method is of particular importance. We find that these matter effect shifts do not depend on any of the details of the detector characteristics apart from the baseline and earth mass density between reactor(s) and detector, but do depend on the normalized product of reactor neutrino spectrum times the inverse-beta decay cross-section. The results of this manuscript suggests an alternative analysis method for measuring sin 2 θ 12 and Δm$^{2}_{21}$ in JUNO which would be a useful cross check of the standard analysis and for the understanding of the Wolfenstein matter effect. The explanation of these shifts together with a quantitative understanding, using a semi-analytical method, is the principal purpose of this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The gallium anomaly

In order to test the end-to-end operations of gallium solar neutrino experiments, intense electron-capture sources were fabricated to measure the responses of the radiochemical SAGE and GALLEX/GNO detectors to known fluxes of low-energy neutrinos. Such tests were viewed at the time as a cross-check, given the many tests of 71 Ge recovery and counting that had been routinely performed, with excellent results. However, the four 51 Cr and 37 Ar source experiments yielded rates below expectations, a result commonly known as the Ga anomaly. As the intensity of the electron-capture sources can be measured to high precision, the neutrino lines they produce are fixed by known atomic and nuclear rates, and the neutrino absorption cross section on 71 Ga is tightly constrained by the lifetime of 71 Ge, no simple explanation for the anomaly has been found. To check these calibration experiments, a dedicated experiment BEST was performed, utilizing a neutrino source of unprecedented intensity and a detector optimized to increase statistics while providing some information on counting rate as a function of distance from the source. The results BEST obtained are consistent with the earlier solar neutrino calibration experiments, and when combined with those measurements, yield a Ga anomaly with a significance of approximately 4𝜎, under conservative assumptions. But BEST found no evidence of distance dependence and thus no explicit indication of new physics. In this review we describe the extensive campaigns carried out by SAGE, GALLEX/GNO, and BEST to demonstrate the reliability and precision of their experimental procedures, including 71 Ge recovery, counting, and analysis. We also describe efforts to define uncertainties in the neutrino capture cross section, which now include estimates of effects at the ≲ 0.5% level such as radiative corrections and weak magnetism. With the results from BEST, an anomaly remains even if one retains only the transition to the 71 Ge ground state, whose strength is fixed by the known lifetime of 71 Ge. We then consider the new-physics solution most commonly suggested to resolve the Ga anomaly, oscillations into a sterile fourth neutrino, 𝜈 𝑒 → 𝜈 𝑠 . We find such a solution generates substantial tension with several null experiments, owing to the large mixing angle required. While this does not exclude such solutions – the sterile sector might include multiple neutrinos as well as new interactions – it shows the need for more experimental constraints, if we are to make progress in resolving the Ga and other low-energy neutrino anomalies. We conclude by consider the role future low-energy electron-capture sources could play in this effort.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In Situ Data Infrastructure for Scientific Unit Testing Platform

Testing is a significant software development process for the management of software systems and scientific code. However, as the complexity of scientific codes increases, extra checks are needed to monitor impacts to dependent models and to verify system constraints. The software complexity also impedes the efforts of module developers and software engineers to rapidly develop and extend their code. Recently, we have developed an automatic methodology and prototype platform to facilitate scientific verification of individual functions within complex scientific codes. With this system, the scientific module builders are able to track variables conveniently in one module or track variables’ changes among different modules. In this paper, we present a procedure for automatic unit testing generation. For the interest of a general audience of this conference, we are emphasizing the technical details of integrating the In Situ data infrastructure into our platform. At the end of this paper, we have included an implementation of unit testing for the ACME Land Model (ALM) to demonstrate the usefulness and correctness of the platform. We have also used single- and multipoint checks to demonstrate the efficient variable tracking capability of this platform.

97 MATHEMATICS AND COMPUTING↗

Quality control and estimation of global solar radiation in China

Measurements of surface radiation in China are too sparse to meet demand for scientific research and engineering applications. Moreover, the radiation data often include erroneous and questionable values though preliminary quality-check has been done before the data release. Therefore, quality control of radiation data is often a prerequisite for using these data. In this study, a set of quality-check procedures were implemented to control the quality of the solar radiation measurements at 97 stations in China. A hybrid model for estimating global solar radiation was then evaluated against the controlled data. The results show that the model can estimate the global radiation with accuracy of MBE less than 1.5 MJ m{sup -2} and RMSE less than 2.8 MJ m{sup -2} for daily radiation and RMSE less than 2.0 MJ m{sup -2} for monthly-mean daily radiation at individual stations over most of China except at a few stations where unsatisfactory estimates were possibly caused by severe air pollution or too dense clouds. The MBE averaged over all stations are about 0.7 MJ m{sup -2} and RMSE about 2.0 MJ m{sup -2} for daily radiation and RMSE about 1.3 MJ m{sup -2} for monthly-mean daily radiation. Finally, this model was used to fill data gaps and to expand solar radiation data set using routine meteorological station data in China. This data set would substantially contribute to some radiation-related scientific studies and engineering applications in China. (author)

14 SOLAR ENERGY↗

Assessment of medical waste management at a primary health-care center in Sao Paulo, Brazil

Highlights: Black-Right-Pointing-Pointer Assessment of medical waste management at health-care center before/after intervention. Black-Right-Pointing-Pointer Qualitative and quantitative results of medical waste management plan are presented. Black-Right-Pointing-Pointer Adjustments to comply with regulation were adopted and reduction of waste was observed. Black-Right-Pointing-Pointer The method applied could be useful for similar establishments. - Abstract: According to the Brazilian law, implementation of a Medical Waste Management Plan (MWMP) in health-care units is mandatory, but as far as we know evaluation of such implementation has not taken place yet. The purpose of the present study is to evaluate the improvements deriving from the implementation of a MWMP in a Primary Health-care Center (PHC) located in the city of Sao Paulo, Brazil. The method proposed for evaluation compares the first situation prevailing at this PHC with the situation 1 year after implementation of the MWMP, thus allowing verification of the evolution of the PHC performance. For prior and post-diagnosis, the method was based on: (1) application of a tool (check list) which considered all legal requirements in force; (2) quantification of solid waste subdivided into three categories: infectious waste and sharp devices, recyclable materials and non-recyclable waste; and (3) identification of non-conformity practices. Lack of knowledge on the pertinent legislation by health workers has contributed to non-conformity instances. The legal requirements in force in Brazil today gave origin to a tool (check list) which was utilized in the management of medical waste at the health-care unit studied. This tool resulted into an adequate and simple instrument, required a low investment, allowed collecting data to feed indicators and also conquered the participation of the unit whole staff. Several non-conformities identified in the first diagnosis could be corrected by the instrument utilized. Total waste generation increased 9.8%, but it was possible to reduce the volume of non-recyclable materials (11%) and increase the volume of recyclable materials (4%). It was also possible to segregate organic waste (7%), which was forwarded for production of compost. The rate of infectious waste generation in critical areas decreased from 0.021 to 0.018 kg/procedure. Many improvements have been observed, and now the PHC complies with most of legal requirements, offers periodic training and better biosafety conditions to workers, has reduced the volume of waste sent to sanitary landfills, and has introduced indicators for monitoring its own performance. This evaluation method might subsidize the creation and evaluation of medical waste management plans in similar heath institutions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterizing and Improving the Thermal Stability of Organic Photovoltaics Based on Halogen-Rich Non-Fullerene Acceptors

In this work, the thermal stability of inverted, halogen-rich non-fullerene acceptor (NFA)-based organic photovoltaics (OPVs) with MoO x as the hole transporting layer is studied at temperatures up to 80°C. Over time, the power conversion efficiency shows a “check-mark” shaped thermal aging pattern, featuring an early decrease, followed by a long-term recovery. A high Cl concentration at the BHJ/MoO x interface in the thermally aged device is found using energy dispersive X-ray spectroscopy. X-Ray photoelectron spectroscopy shows that the MoO x is chlorinated after thermal aging. With bulk quantum efficiency analysis, we propose an explanation to the check-mark shaped pattern. Inserting a thin C 70 layer between the BHJ and MoO x suppresses the thermal degradation mechanisms, resulting in 3 orders of magnitude increase in device lifetime at 80°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Effects of Localized Thermal Pressure on Equilibrium Magnetic Fields and Particle Drifts in The Inner Magnetosphere

Localized injections of hot anisotropic plasma sheet particles into the inner magnetosphere can significantly deform the quiet time dipole–like magnetic field and thus disturb electron and ion's drift paths and scattering rates. Although many details of magnetic field deformation can be inferred from empirical models, roles of different characteristics of injected plasma on the structure of such deformation require further investigation. In this study, we use the 2–D axisymmetric equilibrium model to calculate self–consistent magnetic field in force balance with a Gaussian thermal pressure distribution characterized by four input parameters: the ratio between plasma pressure and magnetic pressure ( β ) at the pressure peak β 0 , the radial location of the pressure peak L 0 , the width of the half peak pressure σ 0 , and the equatorial pressure anisotropy A e . Using the modeled magnetic field, we find that the magnetic field perturbation increases with increasing β 0 and decreasing σ 0 while the magnetic curvature perturbation increases with increasing A e , β 0 , and σ 0 and decreasing L 0 . For energetic particles the change of magnetic gradient drift motion is much greater than that of curvature drift motion. The magnetic dip structure formation requires a critical β value that increases with increasing σ 0 and decreasing L 0 . Despite the unavailability of observations in the existing literatures to check the condition of magnetic dip formation, such condition will be checked against observations as a future study. Lastly, we also use 3–D ring current–atmosphere interactions model with self–consistent magnetic field model to illustrate the effect of azimuthal pressure distribution, which is relevant to asymmetric ring current.

79 ASTRONOMY AND ASTROPHYSICS↗

Base excision repair and double strand break repair cooperate to modulate the formation of unrepaired double strand breaks in mouse brain

Abstract We lack the fundamental information needed to understand how DNA damage in the brain is generated and how it is controlled over a lifetime in the absence of replication check points. To address these questions, here, we integrate cell-type and region-specific features of DNA repair activity in the normal brain. The brain has the same repair proteins as other tissues, but normal, canonical repair activity is unequal and is characterized by high base excision repair (BER) and low double strand break repair (DSBR). The natural imbalance creates conditions where single strand breaks (SSBs) can convert to double strand breaks (DSBs) and reversibly switch between states in response to oxidation both in vivo and in vitro. Our data suggest that, in a normal background of repair, SSBs and DSBs are in an equilibrium which is pushed or pulled by metabolic state. Interconversion of SSB to DSBs provides a physiological check point, which would allow the formation of unrepaired DSBs for productive functions, but would also restrict them from exceeding tolerable limits.

Science & Technology - Other Topics↗

Monte-Carlo Simulations: FLUKA vs. MCNPX

Several experiments were performed at the Phasotron and Nuclotron accelerators in JINR Dubna in which spallation reactions and neutron transport were studied. The experimental results were checked against the predictions of the Monte-Carlo code MCNPX. The discrepancies at 1.5 GeV and 2 GeV on the 'Energy plus Transmutation' setup were observed. Therefore the experimental results were checked with another code-FLUKA.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative Study on Code-based Linear Evaluation of an Existing RC Building Damaged during 1998 Adana-Ceyhan Earthquake

Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performed on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 mx7.80 m = 127.90 m{sup 2} with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher than the requirements of the Turkish Earthquake Code while the selected ground conditions represent the same characteristics. The main reason is that the ordinate of the horizontal elastic response spectrum for Eurocode 8 is increased by the soil factor. In TEC'07 force-based linear assessment, the seismic demands at cross-sections are to be checked with residual moment capacities; however, the chord rotations of primary ductile elements must be checked for Eurocode safety verifications. On the other hand, the demand curvatures from linear methods of analysis of Eurocode 8 together with TEC'07 are almost similar.

58 GEOSCIENCES↗

X-ray diagnostic calibration with the tabletop laser facility EQUINOX

The broadband x-ray emission of a target irradiated by a laser can be used to check the calibration of detectors. At CEA-DIF we have a tabletop picosecond laser facility called EQUINOX with 0.3 J at 800 nm. The laser is focused inside a target chamber onto a solid target and produces bright radiation in the 100-2000 eV spectral range. The x-ray source is routinely monitored with a pinhole camera for source dimension measurement and with x-ray diodes for flux measurement. In addition an x-ray transmission grating spectrometer, a crystal spectrometer, and a single count charge coupled device camera measure the x-ray spectrum between 100 eV and 15 keV. The absolute calibration of those sets of spectrometers allows us to fully characterize x-ray emission spectra. Typical duration is less than 100 ps. The spectrum can be tuned by changing target material, pulse length, and x-ray filters. An application to checking the calibration of x-ray diodes used in the broad band spectrometer DMX with single shots will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron ({sup 3}He) Spin Structure Functions at Low Q{sup 2}

Experiment E97-110 was performed at the Thomas Jefferson National Accelerator Facility to provide a precise measurement of the {sup 3}He spin structure functions at low Q{sup 2} from 0.02 to 0.3 [GeV/c]{sup 2}. A longitudinally-polarized electron beam was scattered from a longitudinally or transversely polarized {sup 3}He target. From these data, we have extracted moments of the neutron and {sup 3}He spin structure functions at very low momentum transfers. These data allow us to make a benchmark check of Chiral Perturbation Theory calculations in a region where they are expected to be valid. In these proceedings, the experimental details are discussed and preliminary results on the first moments of the g{sub 1} (x,Q{sup 2}) and g{sub 2} (x,Q{sup 2}) structure functions are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Neutron and {sup 3}He Spin Structure Functions at Low Q{sup 2}

Experiment E97-110 was performed at the Thomas Jefferson National Accelerator Facility in Hall A to provide a precise measurement of the moments of the neutron and {sup 3}He spin structure functions. A longitudinally-polarized electron beam was scattered from a longitudinally or transversely polarized {sup 3}He target. The extended Gerasimov-Drell-Hearn integral and other moments of the neutron and {sup 3}He spin structure functions were extracted at very low momentum transfers (0.02<Q{sup 2}<0.3 [GeV/c]{sup 2}). These data allow us to make a benchmark check of Chiral Perturbation Theory calculations in a region where they are expected to be valid. In these proceedings, the experimental details are discussed and preliminary results on the moments of the spin structure functions are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulating the JET ITER-like Antenna circuit

A set of simulation/interpretation tools based on transmission line theory and on the RF model developed by M. Vrancken has been developed to study the ITER-like Antenna (ILA) at JET. For given tuning element settings, the unique solution of the equations governing the ILA circuit requires solving a system of coupled linear equations relating the voltages and currents at the antenna straps and other key locations. This computation allows cross-checking predicted values against measured experimental ones. Further more, a minimization procedure allows improving the correspondence with the quantities measured in the circuit during shots, thus coping with unavoidable errors arising from uncertainties in the measurements or from inaccuracies in the adopted RF model. Typical applications are e.g. fine-tuning of the second-stage of the ILA circuit for increased ELM-resilience, cross-checking the calibration of the measurements throughout the circuit and predicting the antenna performance and matching conditions in new plasma scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron Capture Gamma-Ray Libraries for Nuclear Applications

The neutron capture reaction is useful in identifying and analyzing the gamma-ray spectrum from an unknown assembly as it gives unambiguous information on its composition. This can be done passively or actively where an external neutron source is used to probe an unknown assembly. There are known capture gamma-ray data gaps in the ENDF libraries used by transport codes for various nuclear applications. The Evaluated Gamma-ray Activation file (EGAF) is a new thermal neutron capture database of discrete line spectra and cross sections for over 260 isotopes that was developed as part of an IAEA Coordinated Research Project. EGAF is being used to improve the capture gamma production in ENDF libraries. For medium to heavy nuclei the quasi continuum contribution to the gamma cascades is not experimentally resolved. The continuum contains up to 90% of all the decay energy and is modeled here with the statistical nuclear structure code DICEBOX. This code also provides a consistency check of the level scheme nuclear structure evaluation. The calculated continuum is of sufficient accuracy to include in the ENDF libraries. This analysis also determines new total thermal capture cross sections and provides an improved RIPL database. For higher energy neutron capture there is less experimental data available making benchmarking of the modeling codes more difficult. We are investigating the capture spectra from higher energy neutrons experimentally using surrogate reactions and modeling this with Hauser-Feshbach codes. This can then be used to benchmark CASINO, a version of DICEBOX modified for neutron capture at higher energy. This can be used to simulate spectra from neutron capture at incident neutron energies up to 20 MeV to improve the gamma-ray spectrum in neutron data libraries used for transport modeling of unknown assemblies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute np and pp Cross Section Determinations Aimed At Improving The Standard For Cross Section Measurements

Purpose of present research is a keeping improvement of the standard for cross section measurements of neutron-induced reactions. The cross sections for np and pp scattering below 1 GeV are determined based on partial-wave analyses (PWAs) of nucleon-nucleon scattering data. These cross sections are compared with the most recent ENDF/B-VII.0 and JENDL-4.0 data files, and the Nijmegen PWA. Also a comparison of evaluated data with recent experimental data was made to check a quality of evaluation. Excellent agreement was found between the new experimental data and our PWA predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New results on the neutron spin polarizabilities at low Q{sup 2}

Thomas Jefferson National Accelerator Facility (Jefferson Lab) has become one of the premier facilities for the study of nucleon spin structure. Over the past two decades, several high precision measurements of the polarized structure functions g1(x,Q{sup 2}) and g2(x,Q{sup 2}) have been performed that have extensively covered the region between 0.02 and 5 GeV{sup 2}. Spin moments have been formed from the measured structure functions. These proceedings will concentrate on experiment E97-110, which was performed in Hall A to study the neutron and {sup 3}He spin structure at four-momentum transfers squared (Q{sup 2}) = 0.02 - 0.26 GeV{sup 2}. This range allows us to make a benchmark-check of Chiral Perturbation Theory calculations. Previous results for the neutron spin polarizability, {delta}LT , down to 0.1 GeV{sup 2} have shown significant disagreement with the calculations. Preliminary results on the generalized spin polarizabilities, {gamma}0 and {delta}LT , for the neutron were presented at the conference and will be discussed here.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗