Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibrating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Spectrally and Radiometrically Stable Wide-Band on Board Calibration Source for In-Flight Data Validation in Imaging Spectroscopy Applications

The quality of the quantitative spectral data collected by an imaging spectrometer instrument is critically dependent upon the accuracy of the spectral and radiometric calibration of the system. In order for the collected spectra to be scientifically useful, the calibration of the instrument must be precisely known not only prior to but during data collection. Thus, in addition to a rigorous in-lab calibration procedure, the airborne instruments designed and built by the NASA/JPL Imaging Spectroscopy Group incorporate an on board calibrator (OBC) system with the instrument to provide auxiliary in-use system calibration data. The output of the OBC source illuminates a target panel on the backside of the foreoptics shutter both before and after data collection. The OBC and in-lab calibration data sets are then used to validate and post-process the collected spectral image data. The resulting accuracy of the spectrometer output data is therefore integrally dependent upon the stability of the OBC source. In this paper we describe the design and application of the latest iteration of this novel device developed at NASA/JPL which integrates a halogen-cycle source with a precisely designed fiber coupling system and a fiber-based intensity monitoring feedback loop. The OBC source in this Airborne Testbed Spectrometer was run over a period of 15 hours while both the radiometric and spectral stabilities of the output were measured and demonstrated stability to within 1% of nominal.

visible spectrometers↗

Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers

Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.

calibrating↗

Corrections to the MODIS Aqua Calibration Derived From MODIS Aqua Ocean Color Products

Ocean color products such as, e.g., chlorophyll-a concentration, can be derived from the top-of-atmosphere radiances measured by imaging sensors on earth-orbiting satellites. There are currently three National Aeronautics and Space Administration sensors in orbit capable of providing ocean color products. One of these sensors is the Moderate Resolution Imaging Spectroradiometer (MODIS) on the Aqua satellite, whose ocean color products are currently the most widely used of the three. A recent improvement to the MODIS calibration methodology has used land targets to improve the calibration accuracy. This study evaluates the new calibration methodology and describes further calibration improvements that are built upon the new methodology by including ocean measurements in the form of global temporally averaged water-leaving reflectance measurements. The calibration improvements presented here mainly modify the calibration at the scan edges, taking advantage of the good performance of the land target trending in the center of the scan.

MODIS↗

In Flight Calibration of the Magnetospheric Multiscale Mission Fast Plasma Investigation

The Fast Plasma Investigation (FPI) on the Magnetospheric Multiscale mission (MMS) combines data from eight spectrometers, each with four deflection states, into a single map of the sky. Any systematic discontinuity, artifact, noise source, etc. present in this map may be incorrectly interpreted as legitimate data and incorrect conclusions reached. For this reason it is desirable to have all spectrometers return the same output for a given input, and for this output to be low in noise sources or other errors. While many missions use statistical analyses of data to calibrate instruments in flight, this process is difficult with FPI for two reasons: 1. Only a small fraction of high resolution data is downloaded to the ground due to bandwidth limitations and 2: The data that is downloaded is, by definition, scientifically interesting and therefore not ideal for calibration. FPI uses a suite of new tools to calibrate in flight. A new method for detection system ground calibration has been developed involving sweeping the detection threshold to fully define the pulse height distribution. This method has now been extended for use in flight as a means to calibrate MCP voltage and threshold (together forming the operating point) of the Dual Electron Spectrometers (DES) and Dual Ion Spectrometers (DIS). A method of comparing higher energy data (which has low fractional voltage error) to lower energy data (which has a higher fractional voltage error) will be used to calibrate the high voltage outputs. Finally, a comparison of pitch angle distributions will be used to find remaining discrepancies among sensors.

Detection-system↗

A Revised Calibration Function and Results for the Phoenix Mission TECP Relative Humidity Sensor

The original calibration function of the R(sub H) sensor on the Phoenix Thermal and Electrical Conductivity Sensor (TECP) has been revised in order to extend the range of the valid calibration, and to improve accuracy. The original function returned non-physical R(sub H) values at the lowest temperatures. To resolve this, and because the original calibration was performed against a pair of hygrometers that measured frost point (T(sub f)), the revised calibration equation is also cast in terms of frost point. Because of the complexity of maintaining very low temperatures and high R(sub H) in the laboratory, no calibration data exists at T is greater than 203K. However, sensor response during the mission was smooth and continuous down to 181 K. Therefore we have opted to include flight data in the calibration data set; selection was limited to data acquired during periods when the atmosphere is known to have been saturated. T(sub f) remained below 210 K throughout the mission(P is greater than 0.75 Pa). R(sub H), conversely, ranged from 1 to well under 0.01 diurnally, due to approximately 50 K temperature variations. To first order, both vapor pressure and its variance are greater during daylight hours. Variance in overnight humidity is almost entirely explained by temperature, while atmospheric turbulence contributes substantial variance to daytime humidity. Likewise, data gathered with the TECP aloft reflect higher H2O abundances than at the surface, as well as greater variance. There is evidence for saturation of the atmosphere overnight throughout much of the mission. In virtually every overnight observation, once the atmosphere cooled to T(sub f), water vapor begins to decrease, and tracks air temperature. There is no evidence for substantial decreases in water vapor prior to saturation, as expected for adsorptive exchange. Likewise, there is no evidence of local control of vapor by phases such as perchlorate hydrates hydrated minerals. The daytime average H2O pressure does not change substantially over the course of the mission, although the H2O column abundance varies by a factor of 2. Column abundances calculated from TECP data are lower than orbital measurements if one assumes that H2O is uniformly mixed through a single scale height. These results argue that the vertical distribution of H2O begins to change well in advance of surface concentrations as northern autumn approaches.

Phoenix Thermal and Electrical Conductivity Sensor↗

Wind Tunnel Strain-Gage Balance Calibration Data Analysis Using a Weighted Least Squares Approach

A new approach is presented that uses a weighted least squares fit to analyze wind tunnel strain-gage balance calibration data. The weighted least squares fit is specifically designed to increase the influence of single-component loadings during the regression analysis. The weighted least squares fit also reduces the impact of calibration load schedule asymmetries on the predicted primary sensitivities of the balance gages. A weighting factor between zero and one is assigned to each calibration data point that depends on a simple count of its intentionally loaded load components or gages. The greater the number of a data point's intentionally loaded load components or gages is, the smaller its weighting factor becomes. The proposed approach is applicable to both the Iterative and Non-Iterative Methods that are used for the analysis of strain-gage balance calibration data in the aerospace testing community. The Iterative Method uses a reasonable estimate of the tare corrected load set as input for the determination of the weighting factors. The Non-Iterative Method, on the other hand, uses gage output differences relative to the natural zeros as input for the determination of the weighting factors. Machine calibration data of a six-component force balance is used to illustrate benefits of the proposed weighted least squares fit. In addition, a detailed derivation of the PRESS residuals associated with a weighted least squares fit is given in the appendices of the paper as this information could not be found in the literature. These PRESS residuals may be needed to evaluate the predictive capabilities of the final regression models that result from a weighted least squares fit of the balance calibration data.

calibration analysis↗

Early Calibration and Performance Assessments of NOAA-20 VIIRS Thermal Emissive Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the NOAA-20 (previously JPSS-1) spacecraft has successfully operated since its launch in November, 2017. Similar to the rst VIIRS instrument on the Suomi-National Polar-orbiting Partnership (SNPP) spacecraft, the data are collected in 22 spectral bands that are calibrated by a set of onboard calibrators. This paper provides an overview of the NOAA-20 VIIRS on-orbit operation and calibration, with a particular focus on the thermal emissive bands (TEBs). The results presented in this paper include the on-orbit changes in the TEB spectral band responses, detector noise characterization, and key calibration parameters, such as the nonlinear coefcients derived from the blackbody warm-up cool-down cycles. Other issues, such as the early mission long-wave infrared (LWIR) response degradation due to icing on the dewar window, and their impact on sensor calibration are also discussed. Since launch, the VIIRS instrument temperature has been stable to within ±0.8 K and the cold focal plane temperatures are well controlled with variations less than 40 mK. With the exception of the early degradation observed in the LWIR bands, the TEB gains have been stable to within 0.04% (except I5 at 0.07%). Based on the current performance, VIIRS is expected to meet its calibration requirements throughout its design lifetime.

noise equivalent 25 differential temperature (NEdT↗

Terra and Aqua MODIS Thermal Emissive Bands Calibration and RVS Stability Assessments Using an In Situ Ocean Target

MODIS, whose openly-public data have been used for over two decades to monitor and address global issues, has 16 Thermal Emissive Bands (TEBs) with central wavelengths that range from 3.7 μm to 14.4 μm, and are calibrated on-orbit using observations from its on-board blackbody. In order to maintain MODIS’ rich, well-calibrated archive of multispectral imagery and data, Earth targets are regularly used to track its long-term stability, as well as the consistency between the two sensors onboard the Terra and Aqua satellites. Moreover, these scenes can be used to compare MODIS Earth view data over the complete scan-angle range and evaluate the on-orbit performance of the TEBs response-versus-scan-angle (RVS) over mission lifetime. This manuscript focuses on evaluating the MODIS TEBs Collection (C6.1) radiometric calibration stability for both instruments using an in situ ocean target as reference (hereafter referred to as in situ sea surface temperature (SST)). Furthermore, it will assess the calibration consistency between the MODIS sensors. Lastly, it will analyze the on-orbit RVS stability for Terra and Aqua MODIS. Only cloud-free, nighttime MODIS TEB retrievals were used for the study. A normalization methodology is applied to standardize the MODIS data to the in situ SST. Additionally, spectral corrections were derived between some of the Terra and Aqua MODIS TEBs by using a combination of the MODIS Atmospheric Profile product and MODerate resolution atmospheric TRANsmission (MODTRAN) simulations. Results indicate that most MODIS TEBs exhibit mission-long trends of ±0.50 K – with Terra band 30 presenting the largest downward drift due to residual electronic cross-talk effects. Moreover, the calibration consistency analysis over a warm ocean target demonstrated that the average Terra-to-Aqua MODIS bias for most bands is well within ±0.50 K (bands 27 and 30 show the largest - electronic crosstalk-related - biases). Lastly, the MODIS TEBs RVS trends display changes of ±0.50 K (except for bands 25 and 27 at the end-of-scan angles) for both instruments. Overall, the MODIS TEBs remain well-calibrated and their RVSs aptly-characterized.

MODIS↗

Application of Machine Learning Techniques in Calibration and Data Reduction of Multi-Hole Probes

This work presents procedures for implementing machine learning methods into existing algorithms for multi-hole probe calibration and data reduction. It demonstrates that using artificial neural networks (ANNs) can decrease the amount of calibration data needed to achieve a specific calibration uncertainty by over 50%, while also significantly reducing data reduction times. Instead of surface fitting methods, ANNs are employed. Initially, directional calibration coefficients related to flow angles are computed based on pressure measurements, and then these flow angles serve as input parameters for subsequent ANNs to iteratively define Mach number, static pressure, and total pressure. In an alternative approach, new calibration coefficients directly relate pressure measurements from the five-hole probe to the quantities of interest, thereby eliminating the need for iterative algorithms used in conventional surface fitting methods. This method offers several advantages: an average increase of less than 1%in calibration uncertainty for flow angles and a significant reduction in data reduction times to a few seconds on average. Additionally, the methodology is confirmed to avoid both over- and under-fitting.

Machine Learning↗

Application of Machine Learning Techniques in Calibration and Data Reduction of Multi-Hole Probes

This work presents procedures to implement machine learning methods in the existing algorithms for multi-hole probe calibrations and data reduction. It is shown here, that utilizing artificial neural networks (ANNs) can reduce the amount of calibration data that needs to be acquired in order to obtain a specific calibration uncertainty, by more than 50% while simultaneously reducing data reduction times significantly. ANNs were used instead of the surface fitting methods, where first, the directional calibration coefficients related to the flow angles are calculated based on the pressure measurements, and then the flow angles are used as a set of the input parameters for the following ANNs to define Mach number and static and total pressure iteratively. In a second approach, novel calibration coefficients were used to directly relate the pressure measurements from five-hole probe to the quantities of interest thus, eliminating the need for iterative algorithms used in the conventional surface fitting methods. The advantageous features of this method are an average increase of less than 1% in the calibration uncertainty for flow angles and significant reduction of the data reduction times (few seconds). In addition, we confirmed the methodology to avoid over-fitting and under-fitting.

Machine Learning↗

PACE OCI Lunar Calibration: Initial Results

Launched in February 2024, the Ocean Color Instrument (OCI) onboard NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission has started performing its monthly lunar calibrations at ±7degreeslunar phase angle in March 2024. In this paper, we will describe the OCI lunar calibration methodology and show the results of lunar calibration events during the initial months of PACE/OCI operation. A key difference of OCI lunar calibration from heritage sensors is that the lunar disk integrated irradiance is computed from lunar pixel radiance and sampling distance instead of the instrument’s IFOV. PACE provided a near constant sweep rate during lunar calibration allowing accurate determination of OCI pixel sampling extent. OCI performs lunar calibration in baseline science mode with 282 hyperspectral bands from 315 –895 nm and 7 shortwave infrared bands(940 -2260 nm). For each OCI band, we compute the integrated lunar disk irradiance, and compare the result with a lunar irradiance model (ROLO)prediction. The early results presented here clearly show that OCI’s lunar image acquisition is working as intended and will provide accurate data for OCI’s on-orbit radiometric characterization. The hyperspectral lunar irradiances provided by OCI are expected to become a valuable data set for the evaluation of lunar irradiance models.

calibration↗

FOUR PI CALIBRATION AND MODELING OF A BARE GERMANIUM DETECTOR IN A CYLINDRICAL FIELD SOURCE

In reference 1 the authors described {gamma}-ray holdup assay of a Mossbauer spectroscopy instrument where they utilized two axial symmetric cylindrical shell acquisitions and two disk source acquisitions to determine Am-241 and Np-237 contamination. The measured contents of the two species were determined using a general detector efficiency calibration taken from a 12-inch point source.2 The authors corrected the raw spectra for container absorption as well as for geometry corrections to transform the calibration curve to the applicable axial symmetric cylindrical source - and disk source - of contamination. The authors derived the geometry corrections with exact calculus that are shown in equations (1) and (2) of our Experimental section. A cylindrical shell (oven source) acquisition configuration is described in reference 3, where the authors disclosed this configuration to gain improved sensitivity for holdup measure of U-235 in a ten-chamber oven. The oven was a piece of process equipment used in the Savannah River Plant M-Area Uranium Fuel Fabrication plant for which a U-235 holdup measurement was necessary for its decontamination and decommissioning in 2003.4 In reference 4 the authors calibrated a bare NaI detector for these U-235 holdup measurements. In references 5 and 6 the authors calibrated a bare HpGe detector in a cylindrical shell configuration for improved sensitivity measurements of U-235 in other M-Area process equipment. Sensitivity was vastly improved compared to a close field view of the sample, with detection efficiency of greater than 1% for the 185.7-keV {gamma}-ray from U-235. In none of references 3 - 7 did the authors resolve the exact calculus descriptions of the acquisition configurations. Only the empirical efficiency for detection of the 185.7-keV photon from U-235 decay was obtained. Not until the 2010 paper of reference 1 did the authors derive a good theoretical description of the flux of photons onto the front face of a detector from an axially symmetric cylindrical shell. Subsequent to publication of 1, the theoretical treatment of the cylindrical shell and disk source acquisition sources was recognized by the Los Alamos National Laboratory as suitable for including in the Safeguards Training Program.8 Therefore, we felt it was important to accurately demonstrate the calculus describing the cylindrical shell configuration for the HpGe detector and to theoretically account for the observed bare-detector efficiencies measured in references (3-6). In this paper we demonstrate the applicability of the cylindrical shell derivation to a flexible planar sheet of known Am-241, Eu-152, and Cs-137 activity that we rolled into a symmetrical cylindrical shell of radioactivity. Using the geometry correction equation of reference 1, we calculate geometry correction values using the known detector and source dimensions combined with source to detector distances. We then compare measured detection efficiencies from a cylindrical shell of activity for the 185.7-keV photon (U-235) and for the 414.3-keV photon (Pu-239) with those determined for a 12-inch point source(2,7) to demonstrate agreement between experiment and the theoretically calculated values derived by the Savannah River National Laboratory (SRNL) authors of reference 1. We demonstrate this geometry correction first for the 185.7- and 414.3-keV {gamma}-rays. But because the detector was point source calibrated at 12 inches for the energy range (60 -1700) keV (using two distinct sources) to map its intrinsic efficiency, the geometry correction for any acquisition configuration holds for all photon energies.2 We demonstrate that for ten photon energies in the range 121 keV to 967 keV. The good agreement between experiment and calculation is demonstrated at five source to detector distances using the identical shielded HpGe detector of references 4-7 as well as with a separate HpGe detector. We then extend the measurement to include a single acquisition where the flexible source is wrapped around the bare detector in a symmetrical cylinder that radiates on both faces of the detector as well as on to the detector's cylindrical sides of known dimensions. We derive the exact calculus to calculate the flux of the source on to the cylindrical sides of the detector. We then demonstrate outstanding agreement between the measured efficiency for the two primary U-235 and Pu-239 photons in this oven source configuration compared to the point source of activity for which the detector was originally calibrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

BAYESIAN CALIBRATION OF SAFETY CODES USING DATA FROM SEPARATE-AND INTEGRAL EFFECTS TESTS

Large-scale system codes for simulation of safety performance of nuclear plants may contain parameters whose values are not known very accurately. In order to be able to use the results of these simulation codes with confidence, it is important to learn how the uncertainty on the values of these parameters affects the output of the codes. New information from tests or operating experience is incorporated into safety codes by a process known as calibration, which reduces uncertainty in the output of the safety code, and thereby improves its support for decision-making. Modern analysis capabilities afford very significant improvements on classical ways of doing calibration, and the work reported here implements some of those improvements. The key innovation has come from development of safety code surrogate model (code emulator) construction and prediction algorithms. A surrogate is needed for calibration of plant-scale simulation codes because the multivariate nature of the problem (i.e., the need to adjust multiple uncertain parameters at once to fit multiple pieces of new information) calls for multiple evaluations of performance, which, for a computation-intensive model, makes calibration very computation-intensive. Use of a fast surrogate makes the calibration processes used here with Markov Chain Monte Carlo (MCMC) sampling feasible. Moreover, most traditional surrogates do not provide uncertainty information along with their predictions, but the Gaussian Process (GP) based code surrogates used here do. This improves the soundness of the code calibration process. Results are demonstrated on a simplified scenario with data from Separate and Integral Effect Tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calibration of a Passive Neutron Counter with {sup 242}Pu Standards - 16450

At the Los Alamos National Laboratory TA 55 facility, a large quantity of Heat Source (HS) and MT42 (primarily {sup 242}Pu) has been designated for disposal as TRU waste. The waste, to be packaged in either 55 gal drums or Pipe Overpack Containers (POCs), is scheduled to be assayed with the TA 55 HENC 3 system. The system is owned and operated by the Nuclear Waste Partnership (NWP) under a contract with the Carlsbad DoE field office. The HENC 3 is a combined passive neutron/gamma assay system. The neutron component of the system was previously calibrated up to 21.9 g of {sup 240}Pu effective. This corresponds to approximately 9 g of typical HS plutonium and 13 g of MT42 waste. In order to reduce packaging efforts and radiation dose for waste handling personnel, LANL has requested an increase in the HENC 3 calibration limit to approximate the maximum allowable shipping and storage limits for TRU waste. To increase the limits, NWP has obtained the use of well characterized MT42 source materials. The sources, developed and owned by LANL, range from to 5 g to 200 g of plutonium enriched to 86.6% {sup 242}Pu. Using these sources in combination, multiple measurements were performed with both 55-gal drums and POCs to determine their suitability for extending the neutron calibration range of the system. The results of the measurements were (1) compared to the existing calibration for consistency and (2) used to extend the calibration range to 307 g of {sup 240}Pu effective. This report will discuss the elements of the neutron component of the HENC 3 system, the calibration extension effort, problems encountered, and the results of the measurements. As a result of the extension, HS and MT42 materials can be assayed in 55-gal drums and POCs up to their allowable shipping limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SISTec: Mathematical Calibration of Large Clearance Monitors - 18265

One major path for clearance of large amount of waste arising from the decommission of nuclear power plants is based on measurement with large clearance monitors (also known as free release measurement facilities). These devices utilize multi-detector plastic scintillator arrays (large clearance monitors can consist of up to 24 plastic scintillators) to offer both, extremely low minimum detectable activities (MDA) and short measurement times for waste packages weighing up to one metric ton. However, a major problem with these devices is to obtain nuclide specific efficiencies, especially for geometrically complex large waste packages. Normal procedure for estimating the efficiency is to device dummy waste packages and attach point sources with well-known activities to unfavourable positions in these packages. In accordance with this procedure, calibration factors can be derived in a radiological conservative way. Devising such test dummies is not always possible and the procedure is prone to generating large measurement uncertainties. In this publication, we propose a new method to derive calibration factors by means of the Los Alamos National Laboratory (LANL) simulation tool Monte Carlo N-Particle (MCNP) and a statistical-phenomenological model for the detector characterization. In a multi-step approach, first the detector response for a distribution of activity in a waste package is calculated and subsequently the detectors are mathematically characterized. Applying state of the art statistical and optimizing procedures, parameters for the detector response are derived in a self-consistent way. This also allows to rigorously propagate the uncertainties to the final calculated calibration factors according to the Guide to the Expression of Uncertainty in Measurement (GUM supplement 1). To validate the derived parameters for the detector characterization a minimally invasive experimental setup was devised and installed into the large clearance monitor. It consisted of an aluminum swivel arm which could position point sources to the relevant coordinates. The so collected measurement data not only allowed to investigate the precision of the calculated calibration factors, but also to probe the location of concentrated activity sources in the waste package. Furthermore, data on measurements with dummy waste packages were collected to test the reproducibility of well-known calibration factors. We present the software tool SIStec, which will provide an intuitive user-interface to generate and simulate waste package models and execute the above-mentioned method. Using SIStec, different scenarios for the distribution of activity in the waste package can be probed. This will also allow to optimize the clearance process on various levels. For example, measurement time for pre-measurements can be reduced in exchange for unfavourable calibration factors, which would still allow to meet the regulator limits for clearance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spatiotemporal Automatic Calibration of Infrastructure Lidar, Radar, and Camera with a Global Navigation Satellite System: Preprint

Robust and accurate perception is important for modern intelligent transportation systems (ITS), which use sensors of various modalities for data fusion to create a digital twin of an intersection. Sensor calibration is an important process that creates a unified coordinate frame for the sensor output data so that it can be used for data fusion. Classical approaches for sensor calibration are time-consuming, require an overlapping field of view for feature matching, and are not feasible for ITS application as they cause disruptions in the flow of traffic. In this paper, we present a spatiotemporal automatic calibration approach to calibrate multiple infrastructure lidar, radar, and cameras installed at a traffic intersection. The approach uses global navigation satellite system (GNSS) positioning information shared by connected vehicles, and when the vehicle is detected by the sensor, we match the sensor detections with the GNSS coordinates. The proposed algorithm is evaluated with a real-world dataset utilizing detections from two radars, cameras, and lidars with a test vehicle instrumented with a post-processing kinematic (PPK)-corrected GNSS driving past the sensors installed at a four-way traffic intersection. The experimental results show that the proposed automatic calibration approach can achieve the transformation with a root mean squared error of less than 0.5 for radar and lidar and less than 2 for camera detections. The ability to rapidly calibrate sensors not only benefits initial installations, but can also be used for system health monitoring, while utilizing available connected vehicle data to test the real-time sensor fidelity and operational status.

ADVANCED PROPULSION SYSTEMS↗

Application of Indirect Quantification of 133mXe to Calibration of HPGe Detector

The INL Noble Gas Laboratory provides intercomparison samples for the noble gas analysis laboratories as part of the CTBTO PrepCom IMS. Xe-133m is one of the four relevant radionuclides in nuclear explosion monitoring. Without commercially available Xe-133m calibration standards laboratories must create and improve calibration methods. Improvements in calibration methods at the INL NGL benefit the CTBTO PrepCom through better certified values for Xe-133m intercomparison samples. Calibration of High Purity Germanium detectors for Xe-133m quantification is complicated by the coexistence of Xe-133 in samples under analysis. Xe-133 is typically produced in larger quantities, has higher gamma emission probabilities, and its gammas are detected more efficiently than Xe-133m. Xe-133m activity of samples can be indirectly inferred through the 133:133m activity ratio of a batch of material, and the Xe-133 counts in the assay of a small aliquot of the same material. This indirect quantification method can be leveraged to perform detector calibrations for quantification of Xe-133m. Calibrations can be performed by inferring the Xe-133m to certify the sample, and direct counting to determine detector efficiency. A comparison of method results will be shown.

133mXe↗

Uncertainty Estimate for the Outdoor Calibration of Solar Pyranometers: A Metrologist Perspective

Pyranometers are used outdoors to measure solar irradiance. By design, this type of radiometer can measure the; total hemispheric (global) or diffuse (sky) irradiance when the detector is unshaded or shaded from the sun disk, respectively. These measurements are used in a variety of applications including solar energy conversion, atmospheric studies, agriculture, and materials science. Proper calibration of pyranometers is essential to ensure measurement quality. This paper describes a step-by-step method for calculating and reporting the uncertainty of the calibration, using the guidelines of the ISO 'Guide to the Expression of Uncertainty in Measurement' or GUM, that is applied to the pyranometer; calibration procedures used at the National Renewable Energy Laboratory (NREL). The NREL technique; characterizes a responsivity function of a pyranometer as a function of the zenith angle, as well as reporting a single; calibration responsivity value for a zenith angle of 45 ..deg... The uncertainty analysis shows that a lower uncertainty can be achieved by using the response function of a pyranometer determined as a function of zenith angle, in lieu of just using; the average value at 45..deg... By presenting the contribution of each uncertainty source to the total uncertainty; users will be able to troubleshoot and improve their calibration process. The uncertainty analysis method can also be used to determine the uncertainty of different calibration techniques and applications, such as deriving the uncertainty of field measurements.

14 SOLAR ENERGY↗