Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Charged-Particle Calibration Of Spacecraft-Ranging Signals

Report discusses determination of effective densities of electrically charged particles along paths of microwave signals transmitted to and from spacecraft and use of those densities to calibrate measured signal-propagation times, used to compute distances between ground stations and spacecraft. Oriented toward selection of method of calibration optimal with respect to three criteria: minimization of range error and of root-mean-square uncertainty in range error; minimization of amount, complexity, and/or cost of equipment; and capability of calibrating changes in group velocities of signals on ranging channel.

Nguyen, Tien M.↗

Photocatalytic Active Radiation Measurements and Use

Photocatalytic materials are being used to purify air, to kill microbes, and to keep surfaces clean. A wide variety of materials are being developed, many of which have different abilities to absorb various wavelengths of light. Material variability, combined with both spectral illumination intensity and spectral distribution variability, will produce a wide range of performance results. The proposed technology estimates photocatalytic active radiation (PcAR), a unit of radiation that normalizes the amount of light based on its spectral distribution and on the ability of the material to absorb that radiation. Photocatalytic reactions depend upon the number of electron-hole pairs generated at the photocatalytic surface. The number of electron-hole pairs produced depends on the number of photons per unit area per second striking the surface that can be absorbed and whose energy exceeds the bandgap of the photocatalytic material. A convenient parameter to describe the number of useful photons is the number of moles of photons striking the surface per unit area per second. The unit of micro-einsteins (or micromoles) of photons per m2 per sec is commonly used for photochemical and photoelectric-like phenomena. This type of parameter is used in photochemistry, such as in the conversion of light energy for photosynthesis. Photosynthetic response correlates with the number of photons rather than by energy because, in this photochemical process, each molecule is activated by the absorption of one photon. In photosynthesis, the number of photons absorbed in the 400 700 nm spectral range is estimated and is referred to as photosynthetic active radiation (PAR). PAR is defined in terms of the photosynthetic photon flux density measured in micro-einsteins of photons per m2 per sec. PcAR is an equivalent, similarly modeled parameter that has been defined for the photocatalytic processes. Two methods to measure the PcAR level are being proposed. In the first method, a calibrated spectrometer with a cosine receptor is used to measure the spectral irradiance. This measurement, in conjunction with the photocatalytic response as a function of wavelength, is used to estimate the PcAR. The photocatalytic response function is determined by measuring photocatalytic reactivity as a function of wavelength. In the second method, simple shaped photocatalytic response functions can be simulated with a broad-band detector with a cosine receptor appropriately filtered to represent the spectral response of the photocatalytic material. This second method can be less expensive than using a calibrated spectrometer.

Davis, Bruce A.↗

Calibration of solar cells by the reference cell method - The spectral mismatch problem

The calibration of solar cells by means of solar simulators and calibrated reference cells has always been faced with the problem of errors due to source spectral irradiance mismatch and cell spectral response mismatch. A general expression is derived in this paper to enable calculation of mismatch error. The information required to make this calculation is the relative spectra responses of the test and reference cells, and the relative spectral irradiance of the simulator (over the spectral range defined by cell response). The spectral irradiance of the solar standard is assumed given. Experimental results are presented.

Seaman, C. H.↗

Electromagnetic energy calibration of the SoLid detector with horizontal muons

SoLid is a neutrino experiment at very-short baselinesearching for active-to-sterile oscillations of reactorantineutrinos. The detection principle is based on the pairing oftwo types of solid scintillators: polyvinyl toluene and $^{6}$Li:ZnS(Ag), which is a new technology used in this field ofPhysics. In addition to good neutron-gamma discrimination, thissetup allows the detector to be highly segmented; the basicdetection unit is a 5 cm cube. High segmentation provides numerousadvantages including precise localisation of the Inverse Beta Decay(IBD) products, the derivation of an antineutrino energy estimatorbased on the isolated positron energy, and a powerful backgroundreduction tool that relies on the topological signature of thesignal. Finally, the system is read out by a network ofwavelength-shifting fibres coupled to photosensors. A relativeelectromagnetic calibration is performed with horizontal cosmicmuons. This source poses the simplest calibration problem in which asingle detection unit is involved. In addition, large muon energydeposits allow us to perform a calibration at the most detailedlevel (i.e. per fibre) and to accurately define the fraction ofenergy escaping to neighbouring detection cells. A statisticalprecision at the sub-percent level is reached. The paper alsodiscusses two methods to calibrate the absolute energy scale andpresents their implementation and results. The first method relieson horizontal muons, though the precision is limited to around 10%because of the uncertainty in the energy distribution of suchmuons. A novel, alternative method based on the radioactiveamericium-beryllium source is proposed. It takes advantage of theelectron-positron pair-production process and provides a calibrationpoint at 3.4 MeV (i.e. in the core of the IBD positronspectrum). The paper is concluded with various cross-check includinga determination of the energy spectrum of the standard cosmogenicbackground candle: $^{12}$B.

Abreu, Y. [Antwerp U.]↗

On the system stability and calibration of the image plate/scanner system for plasma diagnosis at the National Ignition Facility

At the National Ignition Facility (NIF), storage phosphor image plates (IP) are used extensively for recording x-rays, charged particles, and neutrons. For x-ray imaging and spectroscopy, absolute and relative calibrations are important for extracting plasma information from the diagnostics. We use Fuji MS, SR, and TR image plates that have been cut to fit custom diagnostic envelopes. The image plates are scanned on a General Electric FLA 7000 IP flying spot scanner. Calibrations for sensitivity, spatial scale, and temperature dependent fade are applied. During a set of recent calibrations, we noticed large shifts in the absolute calibration of the image plate system. The possible source of these shifts is discussed. We discuss scanner stability and a method for calibration. We discuss the fade and temperature effects of the image plates and how this correction is applied within the NIF environment. Here, we also compare our NIF GE FLA 7000 IP scanner with a new General Electric Amersham Typhoon IP scanner.

47 OTHER INSTRUMENTATION↗

Overview of Photovoltaic Calibration and Measurement Standards at GRC

Photovoltaic (PV) systems (cells and arrays) for spacecraft power have become an international market. This market demands accurate prediction of the solar array power output in space throughout the mission life of the spacecraft. Since the beginning of space flight, space-faring nations have independently developed methods to calibrate solar cells for power output in low Earth orbit (LEO). These methods rely on terrestrial, laboratory, or extraterrestrial light sources to simulate or approximate the air mass zero (AM0) solar intensity and spectrum.

Baraona, Cosmo↗

Digital Calibration of TR Modules for Real-Tme Digital Beamforming SweepSAR Architectures

Real-time digital beamforming, combined with lightweight, large aperture reflectors, enable a new architecture, which is the baseline for the proposed DESDynI [Deformation, Ecosystem Structure, and Dynamics of Ice] SAR [Synthetic Aperture Radar] Instrument (or DSI). This new instrument concept requires new methods for calibrating multiple simultaneous channels. The calibration of current state-of-the-art Electronically Steered Arrays typically involves pre-flight TR (Transmit/Receive) module characterization over temperature, and in-flight correction based on measured temperatures. This method ignores the effects of element aging and any drifts unrelated to temperature. We are developing new digital calibration of digital beamforming arrays, which helps to reduce development time, risk and cost. Precision calibrated TR modules enable real-time beamforming architectures by accurately tracking modules' characteristics through closed-loop digital calibration, which tracks systematic changes regardless of temperature. The benefit of this effort is that it would enable a new, lightweight radar architecture, with on-board digital beamforming. This provides significantly larger swath coverage than conventional SAR architectures

Hoffman, James Patrick↗

X-ray spectrometer throughput model for (selected) flat Bragg crystal spectrometers on laser plasma facilities

At large laser faculties, such as OMEGA and the National Ignition Facility (NIF), x-ray spectrometers are provided by the facility to diagnose plasma conditions or monitor backlighters. Often the calibration of these spectrometers is unknown or out of date. In response to this situation, we present a simple ray trace method to calibrate flat crystal spectrometers using only basic information regarding the optical design of the spectrometer. This model is then used to output photometric throughput estimates, dispersion, solid angle, and spectral resolution estimates. This model is applied to the mono angle crystal spectrometer and Super Snout I at the NIF and the X-Ray Spectrometer at the OMEGA laser facility

47 OTHER INSTRUMENTATION↗

The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements

This study addresses the effect of calibration methodologies on calibration responsivities and the resulting impact on radiometric measurements. The calibration responsivities used in this study are provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides outdoor calibration responsivity of pyranometers and pyrheliometers at a 45 degree solar zenith angle and responsivity as a function of solar zenith angle determined by clear-sky comparisons to reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison of the test radiometer under calibration to a reference radiometer of the same type. These different methods of calibration demonstrated 1percent to 2 percent differences in solar irradiance measurement. Analyzing these values will ultimately enable a reduction in radiometric measurement uncertainties and assist in developing consensus on a standard for calibration.

14 SOLAR ENERGY↗

Recommended Practices in Thrust Measurements

Accurate, direct measurement of thrust or impulse is one of the most critical elements of electric thruster characterization, and one of the most difficult measurements to make. The American Institute of Aeronautics and Astronautics has started an initiative to develop standards for many important measurement processes in electric propulsion, including thrust measurements. This paper summarizes recommended practices for the design, calibration, and operation of pendulum thrust stands, which are widely recognized as the best approach for measuring micro N- to mN-level thrust and micro Ns-level impulse bits. The fundamentals of pendulum thrust stand operation are reviewed, along with its implementation in hanging pendulum, inverted pendulum, and torsional balance configurations. Methods of calibration and recommendations for calibration processes are presented. Sources of error are identified and methods for data processing and uncertainty analysis are discussed. This review is intended to be the first step toward a recommended practices document to help the community produce high quality thrust measurements.

microthrusters↗

Evaluation of Radiography for TRISO Buffer Layer Density Measurement

Tristructural isotropic (TRISO) fuel particles consist of a central uranium-bearing kernel and a series of coating layers designed to retain fission products and to ensure fuel performance. Several parameters such as thickness and density must be measured for these coating layers to show that they conform with fuel specifications. Current methods for measuring the density of pyrolytic carbon and silicon carbide layers (liquid gradient density column) and the buffer layer (mercury porosimetry) generate Resource Conservation and Recovery Act (RCRA) radiological-mixed waste. In addition, measurement of buffer and inner pyrolytic carbon layer densities require hot sampling or interrupted coating runs and the mercury porosimetry method used for buffer density measurement only measures the mean buffer density, not the interparticle distribution. A new approach has been evaluated to measure the density of coating layers in TRISO particles based on the dependence of x-ray attenuation in radiographs on material density. This method does not generate RCRA mixed waste, measures density on a particle-by-particle basis, and in principle is capable of measuring the density of all coating layers in a single process. Initial results using thinned TRISO particle sections to evaluate radiography measurement of density as a quality control characterization method are reported herein. In this work, the primary focus is on measurement of the density of the buffer layer; however, with appropriate calibration the method should be applicable to other coating layers. Improvements to the initial method and a full demonstration of the method on the remaining coating layers may be pursued as a future effort.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phase Calibration for the Block 1 VLBI System

Very Long Baseline Interferometry (VLBI) in the DSN provides support for spacecraft navigation, Earth orientation measurements, and synchronization of network time and frequency standards. An improved method for calibrating instrumental phase shifts has recently been implemented as a computer program in the Block 1 system. The new calibration program, called PRECAL, performs calibrations over intervals as small as 0.4 seconds and greatly reduces the amount of computer processing required to perform phase calibration.

Roth, M. G.↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Transfer Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m2 of those traceable to the World InfraRed Standard Group (WISG). The ACPs and pyrgeometer model PIR were deployed outdoors, and the irradiance measured by the PIR was compared against the irradiance measured by ACP95F3. Based on the results it is possible to achieve an uncertainty of ± 3.51 W/m2. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

absolute cavity pyrgeometer↗

Thermal emission spectroscopy for single nanoparticle temperature measurement: optical system design and calibration

Here, we report on the design of an optical system that allows measurement of 600–1650 nm emission spectra for individual nanoparticles (NPs), laser-heated in an electrodynamic trap in controlled atmospheres. A method to calibration of absolute intensity versus wavelength for very low emission intensities is discussed, and examples of NP graphite and carbon black spectra are used to illustrate the methodology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feedback-based calibration for rapid tuning and drift control of quantum processors

This presentation will cover an abstract that has been submitted to the conference, but will not include a paper publication. The presentation details an experimental method for calibrating quantum bits and quantum circuits. All of the data on the slides has been gathered via PyGSTi, an open-source Python-based software developed by Sandia's Quantum Performance Laboratory.

Magann, Alicia Bette↗

Mobile VLBI and GPS measurement of vertical crustal motion

Mobile Very Long Base Interferometry (VLBI) and Global Positioning System (GPS) geodetic measurements have many error sources in common. Calibration of the effects of water vapor on signal transmission through the atmosphere, however, remains the primary limitation to the accuracy of vertical crustal motion measurements made by either technique. The two primary methods of water vapor calibration currently in use for mobile VLBI baseline measurements were evaluated: radiometric measurements of the sky brightness near the 22 GHz emission line of free water molecules and surface meteorological measurements used as input to an atmospheric model. Based upon a limited set of 9 baselines, it is shown that calibrating VLBI data with water vapor radiometer measurements provides a significantly better fit to the theoretical decay model than calibrating the same data with surface meteorological measurements. The effect of estimating a systematic error in the surface meteorological calibration is shown to improve the consistency of the vertical baseline components obtained by the two calibration methods. A detailed error model for the vertical baseline components obtained indicates current mobile VLBI technology should allow accuracies of order 3 cm with WVR calibration and 10 cm when surface meteorological calibration is used.

Kroger, P. M.↗

Mobile very long baseline interferometry and Global Positioning System measurement of vertical crustal motion

Mobile Very Long Base Interferometry (VLBI) and Global Positioning System (GPS) geodetic measurements have many error sources in common. Calibration of the effects of water vapor on signal transmission through the atmosphere, however, remains the primary limitation to the accuracy of vertical crustal motion measurements made by either technique. The two primary methods of water vapor calibration currently in use for mobile VLBI baseline measurements were evaluated: radiometric measurements of the sky brightness near the 22 GHz emission line of free water molecules and surface meteorological measurements used as input to an atmospheric model. Based upon a limited set of 9 baselines, it is shown that calibrating VLBI data with water vapor radiometer measurements provides a significantly better fit to the theoretical decay model than calibrating the same data with surface meteorological measurements. The effect of estimating a systematic error in the surface meteorological calibration is shown to improve the consistency of the vertical baseline components obtained by the two calibration methods. A detailed error model for the vertical baseline components obtained indicates current mobile VLBI technology should allow accuracies of order 3 cm with WVR calibration and 10 cm when surface meteorological calibration is used.

Kroger, Peter M.↗