Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Oglala Omaste 2020

Oglala Lakota Housing Authority (OLHA), the tribally designated housing entity of the Oglala Sioux Tribe, installed solar photovoltaic (PV) systems on six tribal buildings, including the Oglala Lakota Housing Authority administration building, four Veterans Affairs Supportive Housing (HUD-VASH) homes, and one Rural Innovation Fund (RIF) home. Combined, the total solar PV capacity of this project is approximately 54 kilowatts-direct current (kW-DC), offsetting an estimated 74,176 kilowatt-hours (kWh) per year and saving OLHA and tenants of the tribally owned residences approximately $\$$8,226 annually. The lifetime savings of the project is estimated to be $\$$380,344. The project aligns with energy goals of OLHA and the Oglala Sioux Tribe to reduce energy costs for low rent tenants and to reduce our carbon footprint; both of which are in line with Lakota values.

14 SOLAR ENERGY↗

Is Clean Hydrogen Production a Good Fit for Questa? (Final Economic Impact Results) [Slides]

The Village of Questa, New Mexico is aiming to become a regional clean energy hub with robust and diverse employment opportunities for the local community supported by the energy sector and by other businesses inspired or attracted by abundant clean energy, outdoor recreation, and cultural opportunities. A coalition of stakeholders in the Village of Questa, comprising the Village, Kit Carson Electric Cooperative (KCEC), Questa Economic Development Fund, and Chevron, is exploring options to develop hydrogen production facilities as an opportunity to create jobs, provide reliable clean energy, and utilize former mine resources. Questa is home to a molybdenum mine owned by Chevron that closed in 2014. Several residents in Questa and surrounding communities lost their jobs when the mine closed and transitioned from active operations into environmental remediation. Although remediation efforts have been ongoing since 2014 and are expected to continue for at least 16 more years, the number of jobs with Chevron is much smaller now than it was before the closure. Between available workforce, brownfield land, and water rights formerly supporting mine operations but now in a transition period, there are considerable local resources that could be directed toward clean energy generation. Questa's electricity supply is already 100% solar during daylight hours thanks to Kit Carson Electric Cooperative's (KCEC's) strategic decision-making and partnering over the last decade. Now, Questa, KCEC, and Chevron are exploring the potential costs and benefits of siting an electrolytic hydrogen production facility and additional solar photovoltaic (PV) capacity in Questa to further advance the region's clean energy economy. In this report, we estimated the potential economic impacts (i.e., jobs, value added, gross output, tax revenue) of constructing and operating a combined hydrogen (32 MW polymer electrolyte membrane electrolizer + 7.5 MW fuel cell) and solar facility (22.5 MW) in the Village of Questa, as well as the resulting economic spillovers to Taos County and the state of New Mexico. We employ an input-output model that leverages IMPLAN's economic data for the region complemented by construction and operating expenses estimated by NREL and feedback from the local coalition to evaluate the direct, indirect and induced effects of the project construction (transient impacts) and operation (more permanent impacts). Based on the area's average trade profile, feedback from the coalition and current market conditions, these projects are expected to support 487 full-time equivalent jobs during construction, generating $\$24$ million in income for those workers and $\$82$ million in local economic activity in the state. Of those jobs, 106 are expected to be construction sector jobs. These investments are also estimated to add $\$36.5$ million to New Mexico's gross state product (GSP). In the Village of Questa, we estimate 16 jobs will be supported in construction and transportation industries, generating $\$0.9$ million in earnings. In Taos County, the construction phase is expected to support 285 jobs primarily in construction and professional services, while manufacturing jobs dominate the results for the Rest of New Mexico. The Village is also estimated to receive $\$0.9$ million in tax revenue from the construction phase alone. Once in operation, the project continues to impact the state and Questa. Around 20 jobs (full-time equivalent for each year of operation) are supported across New Mexico, with approximately 11 directly employed in Questa by both facilities. The total annual local economic activity supported by ongoing operations is just over $\$1.3$ million/yr, generating $\$1.6$ million/yr in additional income in the state. Annual operations are estimated to add $\$2.1$ million to the state's GSP. The Village is expected to receive around $\$43,000$/yr in tax revenue. Impacts vary significantly depending on which businesses are supplying materials, equipment and services, and where construction workers reside. Choosing local suppliers will most benefit Questa and the New Mexico economy, adding up to 500 jobs during construction and 13 long-term jobs. Local and state governments may consider ways to incentivize local businesses in order to maximize economic benefits.

08 HYDROGEN↗

Is Clean Hydrogen Production a Good Fit for Questa? Final Economic Impact Results

The Village of Questa, New Mexico is aiming to become a regional clean energy hub with robust and diverse employment opportunities for the local community supported by the energy sector and by other businesses inspired or attracted by abundant clean energy, outdoor recreation, and cultural opportunities. A coalition of stakeholders in the Village of Questa, comprising the Village, Kit Carson Electric Cooperative (KCEC), Questa Economic Development Fund, and Chevron, is exploring options to develop hydrogen production facilities as an opportunity to create jobs, provide reliable clean energy, and utilize former mine resources. Questa is home to a molybdenum mine owned by Chevron that closed in 2014. Several residents in Questa and surrounding communities lost their jobs when the mine closed and transitioned from active operations into environmental remediation. Although remediation efforts have been ongoing since 2014 and are expected to continue for at least 16 more years, the number of jobs with Chevron is much smaller now than it was before the closure. Between available workforce, brownfield land, and water rights formerly supporting mine operations but now in a transition period, there are considerable local resources that could be directed toward clean energy generation. Questa's electricity supply is already 100% solar during daylight hours thanks to Kit Carson Electric Cooperative's (KCEC's) strategic decision-making and partnering over the last decade. Now, Questa, KCEC, and Chevron are exploring the potential costs and benefits of siting an electrolytic hydrogen production facility and additional solar photovoltaic (PV) capacity in Questa to further advance the region's clean energy economy. In this report, we estimated the potential economic impacts (i.e., jobs, value added, gross output, tax revenue) of constructing and operating a combined hydrogen (32 MW polymer electrolyte membrane electrolizer + 7.5 MW fuel cell) and solar facility (22.5 MW) in the Village of Questa, as well as the resulting economic spillovers to Taos County and the state of New Mexico. We employ an input-output model that leverages IMPLAN's economic data for the region complemented by construction and operating expenses estimated by NREL and feedback from the local coalition to evaluate the direct, indirect and induced effects of the project construction (transient impacts) and operation (more permanent impacts). Based on the area's average trade profile, feedback from the coalition and current market conditions, these projects are expected to support 487 full-time equivalent jobs during construction, generating $\$24$ million in income for those workers and $\$82$ million in local economic activity in the state. Of those jobs, 106 are expected to be construction sector jobs. These investments are also estimated to add $\$36.5$ million to New Mexico's gross state product (GSP). In the Village of Questa, we estimate 16 jobs will be supported in construction and transportation industries, generating $\$0.9$ million in earnings. In Taos County, the construction phase is expected to support 285 jobs primarily in construction and professional services, while manufacturing jobs dominate the results for the Rest of New Mexico. The Village is also estimated to receive $\$0.9$ million in tax revenue from the construction phase alone. Once in operation, the project continues to impact the state and Questa. Around 20 jobs (full-time equivalent for each year of operation) are supported across New Mexico, with approximately 11 directly employed in Questa by both facilities. The total annual local economic activity supported by ongoing operations is just over $\$1.3$ million/yr, generating $\$1.6$ million/yr in additional income in the state. Annual operations are estimated to add $\$2.1$ million to the state's GSP. The Village is expected to receive around $\$43,000$/yr in tax revenue. Impacts vary significantly depending on which businesses are supplying materials, equipment and services, and where construction workers reside. Choosing local suppliers will most benefit Questa and the New Mexico economy, adding up to 500 jobs during construction and 13 long-term jobs. Local and state governments may consider ways to incentivize local businesses in order to maximize economic benefits.

08 HYDROGEN↗

Balancing CO 2 Pipeline Infrastructure Challenges

Conference presentation at American Association of Petroleum Geologists (AAPG) Carbon Capture, Utilization, and Storage (CCUS) Conference, Houston, Texas, March 28–30, 2022. This study on the pipeline systems revealed challenges that a pipeline system will face: a) pipeline cost estimates and cost drivers, b) cost and hydraulics optimization, and c) temperature effects on the pipeline capacity and maximum injection pressure at an injection well.

01 COAL, LIGNITE, AND PEAT↗

FINAL REPORT WIND POWER WARM SPRINGS RESERVATION TRIBAL LANDS DOE GRANT NUMBER DE-FG36-07GO17077 SUBMITTED BY WARM SPRINGS POWER & WATER ENTERPRISES A CORPORATE ENTITY OF THE CONFEDERATED TRIBES OF WARM SPRINGS WARM SPRINGS, OREGON

Wind Generation Feasibility Warm Springs Power and Water Enterprises (WSPWE) is a corporate entity owned by the Confederated Tribes of the Warm Springs Reservation, located in central Oregon. The organization is responsible for managing electrical power generation facilities on tribal lands and, as part of its charter, has the responsibility to evaluate and develop renewable energy resources for the Confederated Tribes of Warm Springs. WSPWE recently completed a multi-year-year wind resource assessment of tribal lands, beginning with the installation of wind monitoring towers on the Mutton Mountains site in 2003, and collection of on-site wind data is ongoing. The study identified the Mutton Mountain site on the northeastern edge of the reservation as a site with sufficient wind resources to support a commercial power project estimated to generate over 226,000 MWh per year. Initial estimates indicate that the first phase of the project would be approximately 79.5 MW of installed capacity. This Phase 2 study expands and builds on the previously conducted Phase 1 Wind Resource Assessment, dated June 30, 2007. In order to fully assess the economic benefits that may accrue to the Tribes through wind energy development at Mutton Mountain, a planning-level opinion of probable cost was performed to define the costs associated with key design and construction aspects of the proposed project. This report defines the Mutton Mountain project costs and economics in sufficient detail to allow the Tribes to either build the project themselves or contract with a developer under the most favorable terms possible for the Tribes.

17 WIND ENERGY↗

What's in WIPP? Packaging TRU Waste to Enhance WIPP's Capacity - 16515

Beginning in 1999, and continuing for 15 years, the US DOE Waste Isolation Pilot Plant (WIPP) repository successfully disposed of defense Transuranic (TRU) waste. Six of the originally planned ten disposal panels were filled before two unrelated accidents temporarily halted disposal operations in February 2014. Based on counting the gross volume of all containers emplaced in WIPP to date, a little more than half of the legislated volume capacity has been subscribed (91,000 cubic meters). This paper describes the many different packaging configurations that have been used to ship TRU waste to WIPP, and makes observations that may enhance the repository capacity when shipments resume. The contents of shipments to WIPP are limited by many requirements of the repository waste acceptance criteria. These criteria derive from three primary sources; 1) the Certificate of Compliance (CoC), issued by the NRC for Type B shipping packaging used by WIPP; 2) The Hazardous Waste Facility Permit, issued by the New Mexico Environment Department; and 3) the WIPP facility's own Documented Safety Analysis (DSA), developed under DOE's regulation 10CFR830. To meet these criteria, various TRU waste forms have been packaged in different ways, with varying packaging efficiency. Of course, there is an overall upper limit on WIPP's volume capacity that was legislated as part of the WIPP Land Withdrawal Act. The volume counted against this limit has been calculated by simply summing the volumes of individual payload containers shipped to and emplaced at WIPP. This method counts significant non-waste volumes inside the containers due to over-packing inner containers and partially filled containers. Without some change to how disposal volumes are calculated, or how waste is packaged, the amount of TRU waste yet to be shipped to WIPP could exceed the legislated capacity. Concepts to enhance the packaging efficiency of future waste shipments to WIPP are presented. Approximate estimates of the waste versus non-waste volumes that have been emplaced to date are discussed. This paper only considers contact handled TRU waste (i.e., contact dose rates < 2 mSv/hr). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-time global flood estimation using satellite-based precipitation and a coupled land surface and routing model

A widely used land surface model, the Variable Infiltration Capacity (VIC) model, is coupled with a newly developed hierarchical dominant river tracing-based runoff-routing model to form the Dominant river tracing-Routing Integrated with VIC Environment (DRIVE) model, which serves as the new core of the real-time Global Flood Monitoring System (GFMS). The GFMS uses real-time satellite-based precipitation to derive flood monitoring parameters for the latitude band 50°N–50°S at relatively high spatial (~12 km) and temporal (3 hourly) resolution. Examples of model results for recent flood events are computed using the real-time GFMS (http://flood.umd.edu). To evaluate the accuracy of the new GFMS, the DRIVE model is run retrospectively for 15 years using both research-quality and real-time satellite precipitation products. Evaluation results are slightly better for the research-quality input and significantly better for longer duration events (3 day events versus 1 day events). Basins with fewer dams tend to provide lower false alarm ratios. For events longer than three days in areas with few dams, the probability of detection is ~0.9 and the false alarm ratio is ~0.6. In general, these statistical results are better than those of the previous system. Streamflow was evaluated at 1121 river gauges across the quasi-global domain. Validation using real-time precipitation across the tropics (30°S–30°N) gives positive daily Nash-Sutcliffe Coefficients for 107 out of 375 (28%) stations with a mean of 0.19 and 51% of the same gauges at monthly scale with a mean of 0.33. Finally, there were poorer results in higher latitudes, probably due to larger errors in the satellite precipitation input.

flood modelling, flood detection, VIC, DRT, DRIVE,↗

Evaluating national hydrogen refueling infrastructure requirement and economic competitiveness of fuel cell electric long-haul trucks

This study explored the national hydrogen refueling infrastructure requirement along major United States (US) interstate highway corridors to support the deployment of fuel cell electric trucks (FCETs) for the national long-haul trucking fleet. Given the long-haul trucking shipment demand in 2025 projected by the Freight Analysis Framework, locations and capacities of hydrogen stations were identified for inter-zone freight flows, and the total daily refueling demand was estimated for intra-zone flows for each FAF zone. Based on the infrastructure deployment results, we conducted an economic feasibility analysis of FCETs by evaluating the total ownership cost. We found that when the FCET penetration is relatively high (e.g., 10% penetration), FCETs become more competitive in terms of fuel cost and idling cost and could be economic viable if the incremental vehicle cost is reduced to meet the near-term FCET technology cost targets and the liquefaction cost is reduced to an optimal case. We also observed that the station cost depends on regional factors, particularly regional demand, which is used to determine station capacity. Thus, one possible strategy for station roll-out is to have early investment in target regions where station costs are expected to be relatively low such as the Pacific and West South Central regions.

33 ADVANCED PROPULSION SYSTEMS↗

Optimized Floating Offshore Wind Turbine Substructure Design Trends for 10–30 MW Turbines in Low-, Medium-, and High-Severity Wave Environments

Floating offshore wind is a promising renewable energy source, as 60% of the wind resources globally are found at depths requiring floating technologies, it minimizes construction at sea, and provides opportunities for industrialization given a lower site dependency. While floating offshore wind has numerous advantages, a current obstacle is its cost in comparison to more established energy sources. One cost-reduction approach for floating wind is increasing turbine capacities, which minimizes the amount of foundations, moorings, cables, and O&M equipment. This work presents trends in mass-optimized VolturnUS hull designs as turbine capacity increases for various wave environments. To do this, a novel rapid hull optimization framework is presented that employs frequency domain modeling, estimations of statistical extreme responses, industry constructability requirements, and genetic algorithm optimization to generate preliminary mass-optimal VolturnUS hull designs for a given turbine design and set of site conditions. Using this framework, mass-optimized VolturnUS hull designs were generated for 10–30 MW turbines for wave environments of varying severities. These design studies show that scaling up turbine capacities increases the mass efficiency of substructure designs, with decreasing returns, throughout the examined turbine capacity range. Additionally, increased wave environment severity is shown to increase the required mass of a given substructure design.

VolturnUS↗

CHARGE-MAP: An integrated framework to study the multicriteria EV charging infrastructure expansion problem

The widespread adoption of electric vehicles (EVs) in recent years has necessitated the development of effective charging infrastructures. However, charging infrastructure expansion is a multifaceted problem that requires careful consideration of the existing infrastructure, spatiotemporal distribution of charging demands, power-grid capacity, and budget constraints. Here, to approach this complex problem, we present CHARGE-MAP, a data-driven simulation-optimization framework, focused on ensuring meaningful charging experience for individual EV owners. CHARGE-MAP integrates three modules: an agent-based simulation module that estimates spatiotemporal distribution of charging demands by modeling EV adopter mobility and charging behavior; an optimization module that determines optimal new charging station/charger locations and capacities, while minimizing expected detour distances and wait-times with a limited number of new stations; and a power module that determines how to connect the stations to the power grid while maintaining its stability. Using the state of Virginia (consisting of 95 counties and 38 independent cities) as a case study, our results show that CHARGE-MAP can meet the demand of ~198,600 predicted EVs with 1,305 new public charging stations and 2,164 new chargers. It reduces average detour distances for charging by 66% and wait-times at stations by 72% compared to the existing infrastructure. Furthermore, transformer capacity requirement analysis reveals that only 1.8% of residential transformers require upgrades, while over 80% of commercial charging locations can be supported with modest transformer infrastructure (25 to 50 kVA). This indicates that targeted investments can facilitate cost-effective EV integration. Consequently, CHARGE-MAP provides policymakers and urban planners with crucial data-driven insights for effective EV charging infrastructure expansion. Sign up for PNAS alerts.

charging infrastructure↗

Environmental factors have a greater influence on photosynthetic capacity in C 4 plants than biochemical subtypes or growth forms

Our understanding of how photosynthetic capacity varies among C 4 species and across growth and measurement conditions remains limited. We collated 1696 CO 2 response curves of net CO 2 assimilation rate (A/C i curves) from C 4 species grown and measured at various environmental conditions and used these data to estimate the apparent maximum carboxylation activity of phosphoenolpyruvate carboxylase (V pmaxA ) and CO 2 -saturated net photosynthetic rate (A max ), two key parameters describing photosynthetic capacity. We examined how V pmaxA and A max vary with species-specific traits, growth and measurement conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Stochastic simulation of pulverized coal (PC) processes

An increasing population and electricity demand in the U.S. require capacity expansion of power systems. The National Energy Technology Laboratory (NETL), U.S. Department of Energy (DOE), has invested considerable efforts on research and development to improve the design and simulation of these power plants. Incorporation of novel process synthesis techniques and realistic simulation methodologies yield optimal flowsheet configurations and accurate estimation of their performance parameters. To provide a better estimation of such performance indicators, simulation models should predict the process behavior based on not only deterministic values of well-known input parameters but also uncertain variables associated with simulation assumptions. In this work, the stochastic simulation of a load-following pulverized coal (PC) power plant takes into account the variation of three input variables, namely, atmospheric air temperature, atmospheric air humidity, and generation load. These uncertain variables are characterized with probability density functions (pdfs) obtained from available atmospheric and electrical energy generation data. The stochastic simulation is carried out by obtaining a sample of values from the pdfs that generates a set of scenarios under which the model is run. An efficient sampling technique [Hammersley sequence sampling (HSS)] guarantees a set of scenarios uniformly distributed throughout the uncertain variable range. Then, each model run generates results on performance parameters as cycle efficiency, carbon emissions, sulfur emissions, and water consumption that are statistically analyzed after all runs are completed. Among these parameters, water consumption is of importance because an increasing demand has been observed mostly in arid regions of the country and, therefore, constrains the operability of the processes. This water consumption is significantly affected by atmospheric uncertainties. The original deterministic process model simulation was designed in Aspen Plus, and a CAPE-OPEN compliant stochastic simulation capability is employed to run the uncertainty analysis. Initially, the influences of atmospheric conditions and load change on the performance parameters are analyzed separately to understand their individual influences on the process, and then their simultaneous variation is analyzed to generate more realistic estimations of the process performance.

97 MATHEMATICS AND COMPUTING↗

Modeling the cooldown of cryocooler conduction-cooled devices

Cryocooler conduction cooled devices can experience significant cooldown time due to lower available cooling capacity compares to convection cooled devices. Therefore, the cooldown time is an important design parameter for conduction cooled devices. This article introduces a framework developed in Python for calculating the cooldown profiles and cooldown time of cryocooler conduction-cooled devices such as superconducting magnets and accelerator cavities. The cooldown time estimation problem is essentially a system of ordinary first-order differential equations comprising the material properties (temperature dependent thermal conductivity and specific heat capacity) of the components intertwined with the prevailing heat transfer channels (conduction, radiation, and heat flow across pressed contacts) and the cryocooler capacity. The formulation of this ODE system is first presented. This ODE system is then solved using the in-built Python library odeint. A case study is presented comprising a small cryocooler conduction-cooled copper stabilized niobium-titanium magnet. The case study is supplemented with the Python script enabling the reader to simply tweak the device design parameters and optimize the design from the point of view of slow/fast cooldown.

43 PARTICLE ACCELERATORS↗

Quantifying the Solar Energy Resource for Puerto Rico

After Hurricane Maria, multiple U.S. Department of Energy laboratories studied the state of the electric grid in Puerto Rico and analyzed grid resilience and grid integration of renewable energy. As part of the work done at the National Renewable Energy Laboratory, researchers created new solar resource data, conducted a technical potential and supply curve analysis, and studied the interannual variability of the solar resource. A new methodology was developed to downscale solar resource data from the National Solar Radiation Data Base (NSRDB) from a 4-km x 4-km spatial and 30-minute temporal resolution to a 2 km x 2 km and 5-minute resolution. This methodology primarily used simple physical principles to develop high-resolution cloud properties which were then used to compute solar radiation. The high-resolution datasets were validated against ground measurements and the error metrics were found to be similar to the original lower resolution dataset. Using 20 years of downscaled data from the NSRDB multi-year capacity factors for photovoltaics (PV) were developed for both single-axis tracking and fixed latitude-tilt configurations. Use of the multi-year data provides the ability to understand variability in capacity factors due to variability in weather over a long period of time. For Puerto Rico the coastal regions were found to have significant higher capacity factors than inland. Using land-use and terrain information a technical potential analysis was conducted for Puerto Rico. This analysis restricted single PV plant development to a maximum of 100 MW nameplate capacity. The nameplate capacity for each municipality were then determined. Based on our assumptions, 56 of the 78 total municipalities of Puerto Rico contain some level of solar capacity. Most of the interior municipalities did not have any capacity because of the geographic exclusions used in this study. The lowest capacity for a PV plant observed in a municipality was 10 MW. The maximum capacity within a county was 2,000 MW. Further a supply curve analysis was conducted by taking the results of the technical potential and quantifying system and transmission costs. The levelized cost of energy (LCOE) was calculated for each theoretical PV plant site, and the levelized cost of transmission was added to the LCOE to produce a total cost estimate for each site. The results of the supply curve analysis allow for a relative comparison of the cost for integrating new PV capacity into the grid. This analysis indicates that cheaper total LCOE sites tend to be larger in capacity. The total capacity in this study was found to be far beyond the maximum peak load for the island. However, this study does not consider the economic and market potential for development. The cumulative capacity presented in this study assumes that the best locations are developed first and ignores the complex decision paths for new power plant development. Therefore, this analysis can only be treated as illustrative. Finally this study investigates the impact of inter-annual variability of resource using a variety of metrices including probability of exceedance and variation in capacity factor and LCOE. This study demonstrates that the capacity factor or LCOE could vary by over 10% year to year. This clearly indicates the risks involved in using any particular year of data and clearly points to the use of multi-year data to reduce some of the risks related to variability in weather.

14 SOLAR ENERGY↗

Supercondutivity at 9K in Mo 5 PB 2 with evidence for multiple gaps

Superconductivity is observed with critical temperatures near 9 K in the tetragonal compound Mo 5 PB 2 . This material adopts the Cr 5 B 3 structure type common to superconducting Nb 5 Si 3–x Bx, Mo 5 SiB 2 , and W 5 SiB 2 , which have critical temperatures of 5.8–7.8 K. We have synthesized polycrystalline samples of the compound, made measurements of electrical resistivity, magnetic susceptibility, and heat capacity, and performed first-principles electronic structure calculations. The highest T c value (9.2 K) occurs in slightly phosphorus rich samples, with composition near Mo 5 P 1.1 B 1.9 , and the upper critical field H c2 at T = 0 is estimated to be ≈17 kOe. Together, the measurements and band-structure calculations indicate intermediate coupling (λ=1.0), phonon mediated superconductivity. Here, the temperature dependence of the heat capacity and upper critical field H c2 below T c suggest multiple superconducting gaps may be present.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimation of future outflows of e-waste in India

The purpose of this study is to construct an approach and a methodology to estimate the future outflows of electronic waste (e-waste) in India. Consequently, the study utilizes a time-series multiple lifespan end-of-life model proposed by Peralta and Fontanos for estimating the current and future quantities of e-waste in India. The model estimates future e-waste generation quantities by modeling their usage and disposal. The present work considers two scenarios for the approximation of e-waste generation based on user preferences to store or to recycle the e-waste. This model will help formal recyclers in India to make strategic decisions in planning for appropriate recycling infrastructure and institutional capacity building. Also an extension of the model proposed by Peralta and Fontanos is developed with the objective of helping decision makers to conduct WEEE estimates under a variety of assumptions to suit their region of study. During 2007-2011, the total WEEE estimates will be around 2.5 million metric tons which include waste from personal computers (PC), television, refrigerators and washing machines. During the said period, the waste from PC will account for 30% of total units of WEEE generated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anomalous Lattice Properties of Manganese Monosilicide: the Thermodynamic Approach

The temperature dependences of the thermal and elastic MnSi properties are analyzed within the limits of the self-consistent approach. The role of the anharmonicity of acoustic and optical lattice vibrations is analyzed. It is demonstrated that anomalously weak anharmonicity is characteristic for acoustic phonons. In particular, this explains the temperature dependence of the MnSi bulk compressive modulus. The one-electron contribution is estimated and the anomalous non-lattice contribution to the formation of the temperature dependences of heat capacity and volume thermal expansion coefficients.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ferromagnetic ordering in ThSi{sub 2} type CeAu{sub 0.28}Ge{sub 1.72}

The compound CeAu{sub 0.28}Ge{sub 1.72} crystallizes in the ThSi{sub 2} structure type in the tetragonal space group I4{sub 1}/amd with lattice parameters a=b=4.2415(6) A c=14.640(3) A. CeAu{sub 0.28}Ge{sub 1.72} is a polar intermetallic compound having a three-dimensional Ge/Au polyanion sub-network filled with Ce atoms. The magnetic susceptibility data show Curie-Weiss law behavior above 50 K. The compound orders ferromagnetically at {approx}8 K with estimated magnetic moment of 2.48 mu{sub B}/Ce. The ferromagnetic ordering is confirmed by the heat capacity data which show a rise at {approx}8 K. The electronic specific heat coefficient (gamma) value obtained from the paramagnetic temperature range 15-25 K is {approx}124(5) mJ/ mol K{sup 2}. The entropy change due to the ferromagnetic transition is {approx}4.2 J/mol K which is appreciably reduced compared to the value of R ln(2) expected for a crystal-field-split doublet ground state and/or Kondo exchange interactions. - Graphical abstract: CeAu{sub 0.28}Ge{sub 1.72} crystallizes in the ThSi{sub 2} structure type in the tetragonal space group I4{sub 1}/amd and orders ferromagnetically at {approx}8 K.

36 MATERIALS SCIENCE↗