Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

SU-E-J-90: MRI-Based Treatment Simulation and Patient Setup for Radiation Therapy of Brain Cancer

Purpose: Traditional radiation therapy of cancer is heavily dependent on CT. CT provides excellent depiction of the bones but lacks good soft tissue contrast, which makes contouring difficult. Often, MRIs are fused with CT to take advantage of its superior soft tissue contrast. Such an approach has drawbacks. It is desirable to perform treatment simulation entirely based on MRI. To achieve MR-based simulation for radiation therapy, bone imaging is an important challenge because of the low MR signal intensity from bone due to its ultra-short T2 and T1, which presents difficulty for both dose calculation and patient setup in terms of digitally reconstructed radiograph (DRR) generation. Current solutions will either require manual bone contouring or multiple MR scans. We present a technique to generate DRR using MRI with an Ultra Short Echo Time (UTE) sequence which is applicable to both OBI and ExacTrac 2D patient setup. Methods: Seven brain cancer patients were scanned at 1.5 Tesla using a radial UTE sequence. The sequence acquires two images at two different echo times. The two images were processed using in-house software. The resultant bone images were subsequently loaded into commercial systems to generate DRRs. Simulation and patient clinical on-board images were used to evaluate 2D patient setup with MRI-DRRs. Results: The majority bones are well visualized in all patients. The fused image of patient CT with the MR bone image demonstrates the accuracy of automatic bone identification using our technique. The generated DRR is of good quality. Accuracy of 2D patient setup by using MRI-DRR is comparable to CT-based 2D patient setup. Conclusion: This study shows the potential of DRR generation with single MR sequence. Further work will be needed on MR sequence development and post-processing procedure to achieve robust MR bone imaging for other human sites in addition to brain.

60 APPLIED LIFE SCIENCES↗

TH-CD-207B-03: How to Quantify Temporal Resolution in X-Ray MDCT Imaging?

Purpose: In modern CT scanners, a quantitative metric to assess temporal response, namely, to quantify the temporal resolution (TR), remains elusive. Rough surrogate metrics, such as half of the gantry rotation time for single source CT, a quarter of the gantry rotation time for dual source CT, or measurements of motion artifact’s size, shape, or intensity have previously been used. In this work, a rigorous framework which quantifies TR and a practical measurement method are developed. Methods: A motion phantom was simulated which consisted of a single rod that is in motion except during a static period at the temporal center of the scan, termed the TR window. If the image of the motion scan has negligible motion artifacts compared to an image from a totally static scan, then the system has a TR no worse than the TR window used. By repeating this comparison with varying TR windows, the TR of the system can be accurately determined. Motion artifacts were also visually assessed and the TR was measured across varying rod motion speeds, directions, and locations. Noiseless fan beam acquisitions were simulated and images were reconstructed with a short-scan image reconstruction algorithm. Results: The size, shape, and intensity of motion artifacts varied when the rod speed, direction, or location changed. TR measured using the proposed method, however, was consistent across rod speeds, directions, and locations. Conclusion: Since motion artifacts vary depending upon the motion speed, direction, and location, they are not suitable for measuring TR. In this work, a CT system with a specified TR is defined as having the ability to produce a static image with negligible motion artifacts, no matter what motion occurs outside of a static window of width TR. This framework allows for practical measurement of temporal resolution in clinical CT imaging systems. Funding support: GE Healthcare; Conflict of Interest: Employee, GE Healthcare.

60 APPLIED LIFE SCIENCES↗

NMR_DIFFSIM v. 1.0

The software generates and analyzes nuclear magnetic resonance spin diffusion simulations for the purpose of measuring domain sizes or spin diffusion constants in a heterogenous sample. Its primary capabilities are: 1. It solves the spin magnetization diffusion equation to simulate the results of a spin diffusion experiment using any structural input geometry, including structure models generated by molecular dynamics or other computational or experimental methods. 2. It compares the results of simulations on an input structure to experimental data, providing a data fitting algorithm to extract physical information from the experimental data via the simulation. 3. It can provide statistical measures to compare correlations between structural models, to determine domain clustering and connectedness, and to provide goodness-of-fit measures including chord length distributions, chi-squared values, Pearson coefficients and pair correlation functions. 4. It provides output reports, data files, and movies to visualize simulation results.

Sorte, Eric↗

Advanced Fossil Energy Separations and Analysis Research – Thermal Desorption Using Spouted Beds

Mercury and other contaminants in emissions from coal-fired power plants are of interest due to the cost associated with capture and disposal of toxic mercury species. It had recently been postulated in the fossil energy community that spouted beds may be a viable coal pre-treatment technique for thermal desorption of mercury. Spouted beds have the potential to be a near-ideal solid-gas contactor for desorption of mercury species, especially with a few proposed design changes specific for this application. Introduction of draft tubes for spouted beds has addressed some issues with scale-up to better handle the throughput and particle size found in coal-fired power plants. In Phase I, Mainstream Engineering invented and developed a Venturi draft tube spouted bed (VDTSB) to enable process scale-up with fine coal particles and to improve heat and mass transfer. The VDTSB concept increases suction at the bottom of the bed to better entrain material (and reduce the propensity for bridging) at the bottom of the conical vessel. The main advantages of this patent-pending approach are the ability to accept a wide range of coal particle sizes, good heat/mass transfer, process scalability, and robustness. The desorber design was optimized through bed flow visualization experiments; these experiments demonstrated the increased throughput and ease of process scale-up. A high-temperature pilot-scale VDTSB desorber system was designed, fabricated, commissioned, and tested. The heat and mass transfer rates with the VDTSB were measured and compared to a baseline spouted bed with and without a conventional straight draft tube. Pilot-scale VDTSB system performance tests were completed with the Energy and Environmental Research Center (EERC) to measure the rate of mercury desorption over a range of pulverized coal particle sizes, bed temperatures, and reactor geometry. Based on performance results, an initial technoeconomic analysis (TEA) was completed to estimate the cost reduction for emissions treatment compared to current flue-gas mercury capture systems. The following was accomplished in Phase I: Developed scalable design correlations for high-throughput spouted bed systems; Determined cycle time distribution (CTD) and turnover time for straight and Venturi draft tube spouted beds, and showed the VDTSB had lower cycle time (faster turnover) than the straight draft tube (SDT); Reduced weighted-average turnover time by 14% to 43% with Venturi draft tube; narrowed the CTD by up to 75%; Measured heat and mass transfer within the pilot-scale VDTSB desorber and showed that the highest heat transfer rate was 2.98 kW/m 2 ·s with 400 µm particles at a 10 L/min motive gas flowrate; Measured mercury (Hg) desorption rate for lignite, bituminous, and subbituminous coal at 200 °C, 225 °C, 250 °C and 275 °C; Achieved 5.6×10 -10 kg/m 2 -h, 2.6×10 -10 kg/m 2 -h, and 6.5×10 -11 kg/m 2 -h Hg removal rates for lignite, bituminous, and sub-bituminous coals, respectively with no loss in volatile matter and an increase in heating value due to a reduction in moisture content; The unoptimized VDTSB pilot desorber decreased the total mercury concentration of lignite and bituminous coal tests by 61% (dry basis). The subbituminous Powder River Basin (PRB) coal showed a reduction of 18%; Based on our TEA of coal-fired power plants, implementing the VDTSB for coal pretreatment could reduce the mercury capture capital and operating expenses by 36% and 38%, respectively, which exceeded the target goal of 25% reduction; A patent application was prepared, and the results were presented at the 2017 AIChE Annual Meeting (Minneapolis, MN).

20 FOSSIL-FUELED POWER PLANTS↗

Shocked poststarburst galaxy survey. II. The molecular gas content and properties of a subset of spogs

We present CO(1–0) observations of objects within the Shocked POststarburst Galaxy Survey taken with the Institut de Radioastronomie Millimétrique 30 m single dish and the Combined Array for Research for Millimeter Astronomy interferometer. Shocked poststarburst galaxies (SPOGs) represent a transitioning population of galaxies, with deep Balmer absorption (EW{sub Hδ}>5 A-ring ), consistent with an intermediate-age (A-star) stellar population, and ionized gas line ratios inconsistent with pure star formation. The CO(1–0) subsample was selected from SPOGs detected by the Wide-field Infrared Survey Explorer with 22 μm flux detected at a signal-to-noise ratio (S/N) > 3. Of the 52 objects observed in CO(1–0), 47 are detected with S/N > 3. A large fraction (37%–46% ± 7%) of our CO-SPOG sample were visually classified as morphologically disrupted. The H{sub 2} masses detected were between 10{sup 8.7−10.8} M{sub ⊙}, consistent with the gas masses found in normal galaxies, though approximately an order of magnitude larger than the range seen in poststarburst galaxies. When comparing the 22 μm and CO(1–0) fluxes, SPOGs diverge from the normal star-forming relation, having 22 μm fluxes in excess of the relation by a factor of 〈ϵ{sub MIR}〉=4.91{sub −0.39}{sup +0.42}, suggestive of the presence of active galactic nuclei (AGNs). The Na i D characteristics of CO-SPOGs show that it is likely that many of these objects host interstellar winds. Objects with large Na i D enhancements also tend to emit in the radio, suggesting possible AGN driving of neutral winds.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced Pool Boiling of Low-Pressure Refrigerants on Round Tubes- An Experimental Evaluation

Pool boiling heat transfer is one of the most effective heat transfer methos and crucial for several energy conversion processes such as electronic cooling, steam generation, water purification and thermal management. Enhancing boiling heat transfer around the tubes enables higher heat flux, which can improve the efficiency and lead to compact heat exchangers. Delaying the onset of critical heat flux (CHF) allows for higher CHFs and protects equipment during anomalous transient conditions. Growing interest in process intensification and delayed CHF has motivated the current study. An experimental approach has been deployed to investigate a potential technique to enhance the pool boiling performance around small diameter tubes by open cell metal foams. The findings for nucleate pool boiling of Novec HFE 7000 on the externally enhanced and smooth tubes are reported. The enhanced tube comprised of compressed aluminum foam brazed around. All the samples were horizontally oriented, and the experiments were performed under ambient pressure conditions. The heat transfer measurements for the smooth tubes were compared with several existing correlations and established the baseline. The preliminary results showed that the aluminum foam effectively enhanced the heat transfer coefficient and delayed the onset of critical heat flux. In addition, the pool boiling process around the round tube sample was visualized from both side and front views to comprehend the heat transfer mechanisms underlying substantial enhancement observed during experiments.

Yang, Cheng-Min↗

SU-E-I-20: Dead Time Count Loss Compensation in SPECT/CT: Projection Versus Global Correction

Purpose: To compare projection-based versus global correction that compensate for deadtime count loss in SPECT/CT images. Methods: SPECT/CT images of an IEC phantom (2.3GBq 99mTc) with ∼10% deadtime loss containing the 37mm (uptake 3), 28 and 22mm (uptake 6) spheres were acquired using a 2 detector SPECT/CT system with 64 projections/detector and 15 s/projection. The deadtime, Ti and the true count rate, Ni at each projection, i was calculated using the monitor-source method. Deadtime corrected SPECT were reconstructed twice: (1) with projections that were individually-corrected for deadtime-losses; and (2) with original projections with losses and then correcting the reconstructed SPECT images using a scaling factor equal to the inverse of the average fractional loss for 5 projections/detector. For both cases, the SPECT images were reconstructed using OSEM with attenuation and scatter corrections. The two SPECT datasets were assessed by comparing line profiles in xyplane and z-axis, evaluating the count recoveries, and comparing ROI statistics. Higher deadtime losses (up to 50%) were also simulated to the individually corrected projections by multiplying each projection i by exp(-a*Ni*Ti), where a is a scalar. Additionally, deadtime corrections in phantoms with different geometries and deadtime losses were also explored. The same two correction methods were carried for all these data sets. Results: Averaging the deadtime losses in 5 projections/detector suffices to recover >99% of the loss counts in most clinical cases. The line profiles (xyplane and z-axis) and the statistics in the ROIs drawn in the SPECT images corrected using both methods showed agreement within the statistical noise. The count-loss recoveries in the two methods also agree within >99%. Conclusion: The projection-based and the global correction yield visually indistinguishable SPECT images. The global correction based on sparse sampling of projections losses allows for accurate SPECT deadtime loss correction while keeping the study duration reasonable.

60 APPLIED LIFE SCIENCES↗

DEEP NEAR-IR OBSERVATIONS OF THE GLOBULAR CLUSTER M4: HUNTING FOR BROWN DWARFS

We present an analysis of deep Hubble Space Telescope (HST)/Wide Field Camera 3 near-IR (NIR) imaging data of the globular cluster (GC) M4. The best-photometry NIR color–magnitude diagram (CMD) clearly shows the main sequence extending toward the expected end of the hydrogen-burning limit and going beyond this point toward fainter sources. The white dwarf (WD) sequence can be identified. As such, this is the deepest NIR CMD of a GC to date. Archival HST optical data were used for proper-motion cleaning of the CMD and for distinguishing the WDs from brown dwarf (BD) candidates. Detection limits in the NIR are around F110W ≈ 26.5 mag and F160W ≈ 27 mag, and in the optical around F775W ≈ 28 mag. Comparing our observed CMDs with theoretical models, we conclude that we have reached beyond the H-burning limit in our NIR CMD and are probably just above or around this limit in our optical–NIR CMDs. Thus, any faint NIR sources that have no optical counterpart are potential BD candidates, since the optical data are not deep enough to detect them. We visually inspected the positions of NIR sources that are fainter than the H-burning limit in F110W and for which the optical photometry did not return a counterpart. We found in total five sources for which we did not get an optical measurement. For four of these five sources, a faint optical counterpart could be visually identified, and an upper optical magnitude was estimated. Based on these upper optical magnitude limits, we conclude that one source is likely a WD, one source could be either a WD or BD candidate, and the remaining two sources agree with being BD candidates. No optical counterpart could be detected for just one source, which makes this source a good BD candidate. We conclude that we found in total four good BD candidates.

79 ASTRONOMY AND ASTROPHYSICS↗

Zunyimycin C inhibits the proliferation of lung cancer cells by inducing apoptosis through an AKT-related mechanism

Objective: Zunyimycin C is a novel halogenated type II polyketide derived from the fermentation product of the Streptomyces species with notable antibiotic activity. However, it is still unclear whether zunyimycin C could inhibit the activity of cancer cells. In this study, human lung adenocarcinoma cell line A549, the large-cell lung cancer cell line NCI-H460 and the non-small-cell lung cancer cell line NCI-H1299 were employed to determine the in vitro anticancer properties of zunyimycin C and underlying molecular mechanisms. Materials and methods: The cellular viability and proliferative properties of lung cancer cells were investigated using the Cell Counting Kit-8 and colony formation assay, respectively. The mRNA expression of apoptotic genes related to lung cancer was studied using reverse-transcription polymerase chain reaction. The apoptotic ratio was measured through flow cytometry. The protein expression was visualized via western blotting using specific antibodies. Results: Zunyimycin C could inhibit cell proliferation and induce apoptosis in a dose-dependent manner. The expression levels of apoptosis-related proteins (i.e., BAX, cleaved-caspase-3, and cleaved-caspase-9) were increased compared with the control group. However, the levels of Bcl-2 and phosphorylated AKT were decreased by administration by zunyimycin C. Conclusions: Collectively, these results implied that zunyimycin C could inhibit cell proliferation and induce apoptosis via AKT phosphorylation.

60 APPLIED LIFE SCIENCES↗

Ultrafast x-ray imaging of coherently controlled molecular dynamics in real space and time

Coherent control aims to manipulate chemical processes on the latent length and timescales of atoms and bonds, scales that are intrinsic to molecular dynamics but not directly resolved by most experimental probes. As a result, existing coherent-control experiments, which overwhelmingly rely on spectroscopic observables, leave a crucial blind spot: the direct, real-space recovery of all atomic and molecular rearrangements in response to coherently controlled excitations. Here, we overcome this limitation by integrating a Tannor-Kosloff-Rice pump-control-probe scheme with ultrafast X-ray scattering to capture snapshots of the wavepacket motion in a benchmark molecular system. We demonstrate this by photoexciting diatomic iodine vapor with a visible pump pulse, selectively steering the wavepacket toward ground-state recombination or dissociative pathways with a time-delayed near-IR control pulse, and recording the dynamics with angstrom and femtosecond precision with an ultrashort hard X-ray probe pulse. By comparing these structural observations with numerical solutions of the time-dependent Schrödinger equation, we reveal how coherent control actively reshapes the molecular charge density distribution. Our results pave the way for leveraging structural feedback as a control handle and provide a fundamental microscopic visualization of quantum decoherence and energy redistribution at the atomic level.

Hopper, Thomas R. [SLAC National Accelerator Labor↗

Topological Characterization and Uncertainty Visualization of Atmospheric Rivers

Atmospheric rivers (ARs) are long, narrow regions of water vapor in the Earth's atmosphere that transport heat and moisture from the tropics to the mid-latitudes. ARs are often associated with extreme weather events in North America and contribute significantly to water supply and flood risk. However, characterizing ARs has been a major challenge due to the lack of a universal definition and their structural variations. Existing AR detection tools (ARDTs) produce distinct AR boundaries for the same event, making the risk assessment of ARs a difficult task. Understanding these uncertainties is crucial to improving the predictability of AR impacts, including their landfall areas and associated precipitation, which could cause catastrophic flooding and landslides over the coastal regions. In this work, we develop an uncertainty visualization framework that captures boundary and interior uncertainties, i.e., structural variations, of an ensemble of ARs that arise from a set of ARDTs. We first provide a statistical overview of the AR boundaries using the contour boxplots of Whitaker et al. that highlight the structural variations of AR boundaries based on their nesting relationships. We then introduce the topological skeletons of ARs based on Morse complexes that characterize the interior variation of an ensemble of ARs. We propose an uncertainty visualization of these topological skeletons, inspired by MetroSets of Jacobson et al. that emphasizes the agreements and disagreements across the ensemble members. Through case studies and expert feedback, we demonstrate that the two approaches complement each other, and together they could facilitate an effective comparative analysis process and provide a more confident outlook on an AR's shape, area, and onshore impact.

54 ENVIRONMENTAL SCIENCES↗

WE-AB-207A-08: BEST IN PHYSICS (IMAGING): Advanced Scatter Correction and Iterative Reconstruction for Improved Cone-Beam CT Imaging On the TrueBeam Radiotherapy Machine

Purpose: To improve CBCT image quality for image-guided radiotherapy by applying advanced reconstruction algorithms to overcome scatter, noise, and artifact limitations Methods: CBCT is used extensively for patient setup in radiotherapy. However, image quality generally falls short of diagnostic CT, limiting soft-tissue based positioning and potential applications such as adaptive radiotherapy. The conventional TrueBeam CBCT reconstructor uses a basic scatter correction and FDK reconstruction, resulting in residual scatter artifacts, suboptimal image noise characteristics, and other artifacts like cone-beam artifacts. We have developed an advanced scatter correction that uses a finite-element solver (AcurosCTS) to model the behavior of photons as they pass (and scatter) through the object. Furthermore, iterative reconstruction is applied to the scatter-corrected projections, enforcing data consistency with statistical weighting and applying an edge-preserving image regularizer to reduce image noise. The combined algorithms have been implemented on a GPU. CBCT projections from clinically operating TrueBeam systems have been used to compare image quality between the conventional and improved reconstruction methods. Planning CT images of the same patients have also been compared. Results: The advanced scatter correction removes shading and inhomogeneity artifacts, reducing the scatter artifact from 99.5 HU to 13.7 HU in a typical pelvis case. Iterative reconstruction provides further benefit by reducing image noise and eliminating streak artifacts, thereby improving soft-tissue visualization. In a clinical head and pelvis CBCT, the noise was reduced by 43% and 48%, respectively, with no change in spatial resolution (assessed visually). Additional benefits include reduction of cone-beam artifacts and reduction of metal artifacts due to intrinsic downweighting of corrupted rays. Conclusion: The combination of an advanced scatter correction with iterative reconstruction substantially improves CBCT image quality. It is anticipated that clinically acceptable reconstruction times will result from a multi-GPU implementation (the algorithms are under active development and not yet commercially available). All authors are employees of and (may) own stock of Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Plant density and enhanced plant vigor estimation for high-resolution images v1

The package contains algorithms for the estimation of sprout/plant density and the corresponding enhanced plant vigor from remotely sensed (RS) images. These algorithms aim to improve the plant characterization and monitoring in the early season when the soil component is significant compared to the plant spatial coverage. In such a scenario, the identification of sprouts (or plants) and the estimation of plant vegetation indexes can be performed only using UAV-acquired images. Additionally, because of the extremely high resolution, gridding becomes necessary to improve visualization and provide more informative maps. However, to capture the real range of values of the VIs, it is important to avoid the inclusion of those pixels belonging to the soil component. The sprout/plant density estimation algorithm takes in input a classification map and uses the vegetation class to estimates the plant density within a user-defined grid using a floating window. Similarly, the enhanced plant vigor algorithm takes in input the vegetation index and the classification map. The enhanced vegetation index is computed for each pixel as the average value among those pixels that belong to the vegetation class within a floating window. The software is developed for the MATLAB environment.

Falco, Nicola↗

In Search of Optimum Fresh-Cut Raw Material: Using Computer Vision Systems as a Sensory Screening Tool for Browning-Resistant Romaine Lettuce Accessions

The popularity of ready-to-eat (RTE) salads has prompted novel technology to prolong the shelf life of their ingredients. Fresh-cut romaine lettuce is widely used in RTE salads; however, its tendency to quickly discolor continues to be a challenge for the industry. Selecting the ideal lettuce accessions for use in RTE salads is essential to ensure maximum shelf life, and it is critical to have a practical way to assess and compare the quality of multiple lettuce accessions that are being considered for use in fresh-cut applications. Thus, in this work we aimed to determine whether a computer vision system (CVS) composed of image acquisition, processing, and analysis could be effective to detect visual quality differences among 16 accessions of fresh-cut romaine lettuce during postharvest storage. The CVS involved a post-capturing color correction, effective image segmentation, and calculation of a browning index, which was tested as a predictor of quality and shelf life of fresh-cut romaine lettuce. The results demonstrated that machine vision software can be implemented to replace or supplement the scoring of a trained panel and instrumental quality measurements. Overall visual quality, a key sensory parameter that determines food preferences and consumer behavior, was highly correlated with the browning index, with a Pearson correlation coefficient of −0.85. Other important sensory decision parameters were also strongly or moderately correlated with the browning index, with Pearson correlation coefficients of −0.84 for freshness, 0.79 for off odor, and 0.57 for browning. The ranking of the accessions according to quality acceptability from the sensory evaluation produced a similar pattern to those obtained with the CVS. This study revealed that multiple lettuce accessions can be effectively benchmarked for their performance as fresh-cut sources via a CVS-based method. Future opportunities and challenges in using machine vision image processing to predict consumer preferences for RTE salad greens is also discussed.

Agriculture↗

Heavy-Duty Nonroad Material Handler Electrification Part 1: Real-World Drive Cycle Development

Knowing a detailed operating cycle is critical for developing and testing equipment. Operating cycles can be separated by two clear distinctions: (1) regulatory or non-regulatory and (2) application at the engine-only or full machine level. The Environmental Protection Agency’s (EPA) Nonroad Transient Cycle (NRTC) may be a good representation of engine use in many types of equipment, but there is a gap in standardized and validated drive cycles specifically for nonroad material handlers. Lacking a standardized drive cycle makes it difficult to accurately benchmark machine performance and validate new powertrain technologies. The objective of this investigation is to illustrate the development of a custom drive cycle augmented with real-world customer use data that serves multiple purposes: (1) understand the range of operation and utilization that formulated inputs for electrified architecture analysis and (2) develop a repetitive and consistent maneuver to establish baseline energy consumption enabling equivalent comparison to future electrified prototype builds. This article presents a solution specifically for a 23-ton nonroad material handler in which material handling, machine transport, and extended idle were homologated to form representative short cycles defined by machine velocity and hydraulic cylinder position. The most intensive material handling short cycles had a load factor of 40% and an average fuel rate of 16 L/h. Combined with a visual aid, the short cycles exhibited low variability, having less than 5% root mean square (RMS) error in lift and reach position with respect to the average. The machine’s performance on these short cycles at the Advanced Power Systems Research Center (APSRC) was compared to results from two real-world customer locations operating the instrumented test machine in a cyclical manner, and for similar ground conditions were found to be comparable in fuel consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local bilinear computation of Jacobi sets

Abstract We propose a novel method for the computation of Jacobi sets in 2D domains. The Jacobi set is a topological descriptor based on Morse theory that captures gradient alignments among multiple scalar fields, which is useful for multi-field visualization. Previous Jacobi set computations use piecewise linear approximations on triangulations that result in discretization artifacts like zig-zag patterns. In this paper, we utilize a local bilinear method to obtain a more precise approximation of Jacobi sets by preserving the topology and improving the geometry. Consequently, zig-zag patterns on edges are avoided, resulting in a smoother Jacobi set representation. Our experiments show a better convergence with increasing resolution compared to the piecewise linear method. We utilize this advantage with an efficient local subdivision scheme. Finally, our approach is evaluated qualitatively and quantitatively in comparison with previous methods for different mesh resolutions and across a number of synthetic and real-world examples.

97 MATHEMATICS AND COMPUTING↗

TU-G-BRA-02: Can We Extract Lung Function Directly From 4D-CT Without Deformable Image Registration?

Purpose: Dynamic CT ventilation imaging (CT-VI) visualizes air volume changes in the lung by evaluating breathing-induced lung motion using deformable image registration (DIR). Dynamic CT-VI could enable functionally adaptive lung cancer radiation therapy, but its sensitivity to DIR parameters poses challenges for validation. We hypothesize that a direct metric using CT parameters derived from Hounsfield units (HU) alone can provide similar ventilation images without DIR. We compare the accuracy of Direct and Dynamic CT-VIs versus positron emission tomography (PET) images of inhaled {sup 68}Ga-labelled nanoparticles (‘Galligas’). Methods: 25 patients with lung cancer underwent Galligas 4D-PET/CT scans prior to radiation therapy. For each patient we produced three CT- VIs. (i) Our novel method, Direct CT-VI, models blood-gas exchange as the product of air and tissue density at each lung voxel based on time-averaged 4D-CT HU values. Dynamic CT-VIs were produced by evaluating: (ii) regional HU changes, and (iii) regional volume changes between the exhale and inhale 4D-CT phase images using a validated B-spline DIR method. We assessed the accuracy of each CT-VI by computing the voxel-wise Spearman correlation with free-breathing Galligas PET, and also performed a visual analysis. Results: Surprisingly, Direct CT-VIs exhibited better global correlation with Galligas PET than either of the dynamic CT-VIs. The (mean ± SD) correlations were (0.55 ± 0.16), (0.41 ± 0.22) and (0.29 ± 0.27) for Direct, Dynamic HU-based and Dynamic volume-based CT-VIs respectively. Visual comparison of Direct CT-VI to PET demonstrated similarity for emphysema defects and ventral-to-dorsal gradients, but inability to identify decreased ventilation distal to tumor-obstruction. Conclusion: Our data supports the hypothesis that Direct CT-VIs are as accurate as Dynamic CT-VIs in terms of global correlation with Galligas PET. Visual analysis, however, demonstrated that different CT-VI algorithms might have varying accuracy depending on the underlying cause of ventilation abnormality. This research was supported by a National Health and Medical Research Council (NHMRC) Australia Fellowship, an Cancer Institute New South Wales Early Career Fellowship 13-ECF-1/15 and NHMRC scholarship APP1038399. No commercial funding was received for this work.

60 APPLIED LIFE SCIENCES↗