Search NASA⌕ Search

SEARCH · Search NASA

Results for “Component sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Reaction Optimization for Enzymatic Deconstruction of Industrially Relevant Nylon Composites

Plastics such as polyamides (PAs) possess unique physicochemical properties that make them indispensable in modern society. However, their energy‐intensive production and challenging end‐of‐life management highlight the urgent need for efficient recycling or remanufacturing solutions. Enzymatic depolymerization offers a promising route toward circular recycling, yet remains constrained by limited enzyme characterization, lack of validation under industrially relevant conditions and substrates, and overall performance. Here, we optimized the reaction conditions for three recently discovered nylon‐degrading enzymes. One of them, Nyl12, achieved product titers with PA6 and PA66 that exceed previously reported values, without enzyme engineering or substrate pretreatment. We further demonstrated the scalability of the process and its application to complex PA‐based materials used in microelectronic components. Analysis of substrate features, including surface area and particle size, revealed key parameters governing enzymatic activity and provided a framework for future pretreatment and process optimization efforts. In combination, these efforts provide a new benchmark for enzymatic nylon recycling.

nylon↗

The role of basis set superposition error in water addition reactions to Ln(III) cations

Our goal in this work was to characterize the importance of basis set superposition error (BSSE) in the reaction energetics of water addition to highly charged metal ions that exhibit strong ion-dipole interactions with water. The gas phase water addition reactions, M(H₂O)³+N + H₂O → M(H₂O)³+N + ₁ [M = La(III), Lu(III); N = 0–8] have been studied, with a particular emphasis on a posteriori methods for calculating BSSE and its constituent energetic components as a function of M(H₂O) ³+N cluster size and water basis set. Because of accumulation of BSSE within the subclusters in the reaction series, the successive reaction counterpoise method for determining the BSSE correction interaction energies is advocated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Gamma-Method for Monitoring Ash Content of Coal

A brief analysis is given of the modern instrumental methods of monitoring the ash content of coal. Their particulars and drawbacks are examined. A neutron gamma-method of monitoring the ash content is proposed on the basis of integrated use of prompt γ-radiation accompanying inelastic scattering of fast neutrons and radiative capture of thermal neutrons by nuclei of the primary elements comprising the organic and mineral components of coal. The instrumental-methodological parameters of monitoring (sizes of the analyzed samples, energy intervals of the detected gamma radiation) making it possible to the increase the sensitivity of the method with respect to the ash content and to minimize the impact of the variability of the moisture content of coal on its material composition, are optimized. The method has been certified and recommended for representative monitoring of the quality of coarse coal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intracellular lysyl oxidase: Effect of a specific inhibitor on nuclear mass in proliferating cells

LOX, the principal enzyme involved in crosslinking of collagen, was the first of several lysyl oxidase isotypes to be characterized. Its active form was believed to be exclusively extracellular. Active LOX was later reported to be present in cell nuclei; its function there is unknown. LOX expression opposes the effect of mutationally activated Ras, which is present in about 30% of human cancers. The mechanism of LOX in countering the action of Ras is also unknown. In the present work, assessment of nuclear protein for possible effects of lysyl oxidase activity led to the discovery that proliferating cells dramatically increase their nuclear protein content when exposed to BAPN ({beta}-aminopropionitrile), a highly specific lysyl oxidase inhibitor that reportedly blocks LOX inhibition of Ras-induced oocyte maturation. In three cell types (PC12 cells, A7r5 smooth muscle cells, and NIH 3T3 fibroblasts), BAPN caused a 1.8-, 1.7-, and 2.1-fold increase in total nuclear protein per cell, respectively, affecting all major components in both nuclear matrix and chromatin fractions. Since nuclear size is correlated with proliferative status, enzyme activity restricting nuclear growth may be involved in the lysyl oxidase tumor suppressive effect. Evidence is also presented for the presence of apparent lysyl oxidase isotype(s) containing a highly conserved LOX active site sequence in the nuclei of PC12 cells, which do not manufacture extracellular lysyl oxidase substrates. Results reported here support the hypothesis that nuclear lysyl oxidase regulates nuclear growth, and thereby modulates cell proliferation.

60 APPLIED LIFE SCIENCES↗

Sculpting 2D Crystals via Membrane Contractions before and during Solidification

When phospholipids crystallize within the otherwise fluid membranes of giant unilamellar vesicles, the resulting molecularly thin “2D” solids exhibit great variety in their morphology evolution. For example, within membranes containing moderate amounts of the crystallizing component, crystals grow with a fixed morphology depending on vesicle size. Conversely for membranes containing large amounts of the crystallizing species, we find small compact crystals on vesicles of all sizes. However, on large vesicles, growing crystals sprout flower petals that lengthen progressively. These behaviors result from two combined mechanisms: first, like other 2D solids, the shear rigidity of phospholipid crystals renders them intolerant to morphologies with nonzero Gaussian curvature. As a result and especially at elevated membrane tension, the cost of bending elasticity is reduced at the expense of line energy by the formation of flowers as opposed to compact crystals. Second, the composition-dependent tension rise during cooling relaxes via water permeation of the membrane with a time constant scaling as R2. The amount of crystal formed for a small decrease in temperature determines this composition-dependent increase in stress from thermal contractions versus solidification. Surface Evolver computations were motivated using the predicted tension evolution to develop a processing space that maps to experimental observations for initial and growing crystal morphology. Important variable groups are identified, including a scaled ratio of bending to line energy, a vesicle-size-independent group for membrane contractions, and a time constant for stress relaxation. Though processing stresses ultimately relax, the crystal morphology persists well beyond the processing window.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interior Decoration of Stable Metal–Organic Frameworks

Metal–organic frameworks (MOFs) are a diverse class of hybrid organic/inorganic crystalline materials composed of metal-containing nodes held in place by organic linkers. Through a discerning selection of these components, many properties such as the internal surface area, cavity size and shape, catalytic properties, thermal properties, and mechanical properties may be manipulated. Because of this high level of tunability, MOFs have been heralded as ideal platforms for various applications including gas storage, separation, catalysis, and chemical sensing.(1-8) Regrettably, these theoretical possibilities are limited by the reality of constraining conditions for solvothermal synthesis, which typically include high temperatures (usually over 100 °C), the use of specific solvents, and necessary exposure to acidic or basic conditions. In order to incorporate more delicate functionalities, postsynthesis decoration methods were developed. This feature article focuses on developed interior decoration methods for stable MOFs and the dynamic relationship between such methods and MOF stability. In particular, methods to transform organic, inorganic, and organometallic MOF parts as well as combination techniques, the generation of defects, and the inclusion of enzymes are addressed.

36 MATERIALS SCIENCE↗

Kinetic theory of magnetized dusty plasmas with dust particles charged by collisional processes and by photoionization

In this work, we detail the derivation of a plasma kinetic theory leading to the components of the dielectric tensor for a magnetized dusty plasma with variable charge on the dust particles, considering that the dust component of the plasma contains spherical dust particles with different sizes, which are charged both by inelastic collisions of electrons and ions and by photoionization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluorescence imaging of viscous materials in the ultraviolet-visible wavelength range

This paper presents an approach of an innovative measurement principle for the quality control of viscous materials during a manufacturing process based on fluorescence imaging. The main contribution to the state of the art provided by this measurement system is that three equal fluorescence images of a static or moving viscous object are available in different optical paths. The independent images are obtained by two beam splitters which are connected in series. Based on these images, it is possible to evaluate each image separately. In our case, three optical bandpass filters with different center wavelengths of 405 nm, 420 nm, and 440 nm were used to filter the separate fluorescence images. The developed system is useable for the detection of impurities in the micrometer range. Further, incorrect mixing ratios of particular components and wrong single components in the viscous materials can be detected with the setup. Moreover, it is possible to realize static and dynamic measurements. In this case the maximum speed of the objects was 0.2 m/s for the dynamic measurements. Advantages of this measurement setup are the universality due to the use of optical standard components, the small dimension and the opportunity to integrate it easily into ongoing processes. In addition, the measurement system works on a non-contact basis. Thus, the expense for maintenance is at a very low level compared to currently available measurement setups for the investigated application. Furthermore, the setup provides for the first time a simultaneous analysis of more than one component and the detection of impurities concerning their nature and size in a manufacturing process.

36 MATERIALS SCIENCE↗

Comparative study of magnetic ordering in bulk and nanoparticles of Sm{sub 0.65}Ca{sub 0.35}MnO{sub 3}: Magnetization and electron magnetic resonance measurements

To explore the effect of size reduction to nanoscale on the hole doped Sm{sub 0.65}Ca{sub 0.35}MnO{sub 3} compound, dc magnetic measurements and electron magnetic resonance (EMR) were done on bulk and nanoparticle samples in the temperature range 10 ≤ T ≤ 300 K. Magnetization measurement showed that the bulk sample undergoes a charge ordering transition at 240 K and shows a mixed magnetic phase at low temperature. However, the nanosample underwent a ferromagnetic transition at 75 K, and the charge ordered state was destabilized on size reduction down to nanoscale. The low-temperature ferromagnetic component is found to be enhanced in nanoparticles as compared to their bulk counterpart. Interestingly around room temperature, bulk particles show higher magnetization where as at low temperature nanoparticles show higher magnetization. Ferromagnetism in the bulk is due to super exchange where as ferromagnetism in nanoparticles is due to uncompensated spins of the surface layer. Temperature variation of EMR parameters correlates well with the results of magnetic measurements. The magnetic behaviour of the nanoparticles is understood in terms of the core shell scenario.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Specific features of fluorescence transfer in multiply scattering randomly inhomogeneous layers under intense laser pumping

Based on the analysis of experimental data on the effect of the pulsed laser pump intensity on the spectral properties and the size of the fluorescent response zone in randomly inhomogeneous fluorescent layers, we found that the amplification of spontaneous and stimulated emission significantly affects the statistical properties of the propagation lengths of the fluorescent field partial components in the layers. The experiments are performed with layers of SiO{sub 2} and TiO{sub 2} nanoparticles saturated with rhodamine 6G, pumped by 532-nm laser radiation in the intensity range corresponding to the transient regime from excitation of spontaneous fluorescence to random lasing in the layer. The experimental data are compared with the results of statistical modelling of fluorescence transfer. It is shown that, even at a pump intensity below the random lasing threshold, the spontaneous emission amplification in a layer leads to a significant increase in the contributions to the fluorescence response from partial components with propagation lengths much larger than the layer thickness. This can be interpreted as a manifestation of the quasi-waveguide effect, in which the probability of propagation of diffuse fluorescence components along the layer over distances many times greater than its thickness and the size of the pumped region increases significantly with a decrease in the characteristic radiation amplification length in the layer. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Design of Vacuum Pumping Systems for the Material Plasma Exposure eXperiment

The Material Plasma Exposure eXperiment (MPEX) vacuum pumping system is responsible for creating prototypic conditions in the plasma material interaction chamber that mimic those in a fusion reactor divertor region. Additionally, the vacuum system needs to minimize the pressure in the plasma heating region to improve the coupling of the electron cyclotron heating and ion cyclotron heating to the plasma, minimizing waste heat exhausted to high heat flux components. Here, the final design of the system has been sized to comply with the vacuum pump operating environment and to reduce the number of unique pumps required while meeting performance requirements. Bounding cases with and without the plasma present have been developed in the pumping analysis, and an initial calculation has been performed based on the plasma pumping identified in Proto-MPEX operation though this result will remain unverified until MPEX operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hypothesis tests on Rayleigh wave radiation pattern shapes: a theoretical assessment of idealized source screening

SUMMARY Shallow seismic sources excite Rayleigh wave ground motion with azimuthally dependent radiation patterns. We place binary hypothesis tests on theoretical models of such radiation patterns to screen cylindrically symmetric sources (like explosions) from non-symmetric sources (like non-vertical dip-slip or non-VDS faults). These models for data include sources with several unknown parameters, contaminated by Gaussian noise and embedded in a layered half-space. The generalized maximum likelihood ratio tests that we derive from these data models produce screening statistics and decision rules that depend on measured, noisy ground motion at discrete sensor locations. We explicitly quantify how the screening power of these statistics increase with the size of any dip-slip and strike-slip components of the source, relative to noise (faulting signal strength) and how they vary with network geometry. As applications of our theory, we apply these tests to (1) find optimal sensor locations that maximize the probability of screening non-circular radiation patterns and (2) invert for the largest non-VDS faulting signal that could be mistakenly attributed to an explosion with damage, at a particular attribution probability. Finally, we quantify how certain errors that are sourced by opening cracks increase screening rate errors. While such theoretical solutions are ideal and require future validation, they remain important in underground explosion monitoring scenarios because they provide fundamental physical limits on the discrimination power of tests that screen explosive from non-VDS faulting sources.

58 GEOSCIENCES↗

A dynamic collimation system for penumbra reduction in spot-scanning proton therapy: Proof of concept

Purpose: In the absence of a collimation system the lateral penumbra of spot scanning (SS) dose distributions delivered by low energy proton beams is highly dependent on the spot size. For current commercial equipment, spot size increases with decreasing proton energy thereby reducing the benefit of the SS technique. This paper presents a dynamic collimation system (DCS) for sharpening the lateral penumbra of proton therapy dose distributions delivered by SS. Methods: The collimation system presented here exploits the property that a proton pencil beam used for SS requires collimation only when it is near the target edge, enabling the use of trimmers that are in motion at times when the pencil beam is away from the target edge. The device consists of two pairs of parallel nickel trimmer blades of 2 cm thickness and dimensions of 2 cm × 18 cm in the beam's eye view. The two pairs of trimmer blades are rotated 90° relative to each other to form a rectangular shape. Each trimmer blade is capable of rapid motion in the direction perpendicular to the central beam axis by means of a linear motor, with maximum velocity and acceleration of 2.5 m/s and 19.6 m/s{sup 2}, respectively. The blades travel on curved tracks to match the divergence of the proton source. An algorithm for selecting blade positions is developed to minimize the dose delivered outside of the target, and treatment plans are created both with and without the DCS. Results: The snout of the DCS has outer dimensions of 22.6 × 22.6 cm{sup 2} and is capable of delivering a minimum treatment field size of 15 × 15 cm{sup 2}. Using currently available components, the constructed system would weigh less than 20 kg. For irregularly shaped fields, the use of the DCS reduces the mean dose outside of a 2D target of 46.6 cm{sup 2} by approximately 40% as compared to an identical plan without collimation. The use of the DCS increased treatment time by 1–3 s per energy layer. Conclusions: The spread of the lateral penumbra of low-energy SS proton treatments may be greatly reduced with the use of this system at the cost of only a small penalty in delivery time.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-I-67: X-Ray Fluorescence for Energy Response Calibration of a Photon Counting Detector: A Simulation Study

Purpose: To investigate the feasibility of energy calibration and energy response characterization of a photon counting detector using x-ray fluorescence. Methods: A comprehensive Monte Carlo simulation study was done to investigate the influence of various geometric components on the x-ray fluorescence measurement. Different materials, sizes, and detection angles were simulated using Geant4 Application for Tomographic Emission (GATE) Monte Carlo package. Simulations were conducted using 100 kVp tungsten-anode spectra with 2 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm2 in detection area. The fluorescence material was placed 300 mm away from both the x-ray source and the detector. For angular dependence measurement, the distance was decreased to 30 mm to reduce the simulation time. Compound materials, containing silver, barium, gadolinium, hafnium, and gold in cylindrical shape, were simulated. The object size varied from 5 to 100 mm in diameter. The angular dependence of fluorescence and scatter were simulated from 20° to 170° with an incremental step of 10° to optimize the fluorescence to scatter ratio. Furthermore, the angular dependence was also experimentally measured using a spectrometer (X-123CdTe, Amptek Inc., MA) to validate the simulation results. Results: The detection angle between 120° to 160° resulted in more optimal x-ray fluorescence to scatter ratio. At a detection angle of 120°, the object size did not have a significant effect on the fluorescence to scatter ratio. The experimental results of fluorescence angular dependence are in good agreement with the simulation results. The Kα and Kβ peaks of five materials could be identified. Conclusion: The simulation results show that the x-ray fluorescence procedure has the potential to be used for detector energy calibration and detector response characteristics by using the optimal system geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-293: Simplifying Assumption for Determining Sc and Sp

Purpose: Scp(mlc,jaw) is a two-dimensional function of collimator field size and effective field size. Conventionally, Scp(mlc,jaw) is treated as separable into components Sc(jaw) and Sp(mlc). Scp(mlc=jaw) is measured in phantom and Sc(jaw) is measured in air with Sp=Scp/Sc. Ideally, Sc and Sp would be able to predict measured values of Scp(mlc,jaw) for all combinations of mlc and jaw. However, ideal Sc and Sp functions do not exist and a measured two-dimensional Scp dataset cannot be decomposed into a unique pair of one-dimensional functions.If the output functions Sc(jaw) and Sp(mlc) were equal to each other and thus each equal to Scp(mlc=jaw){sup 0.5}, this condition would lead to a simpler measurement process by eliminating the need for in-air measurements. Without the distorting effect of the buildup-cap, small-field measurement would be limited only by the dimensions of the detector and would thus be improved by this simplification of the output functions. The goal of the present study is to evaluate an assumption that Sc=Sp. Methods: For a 6 MV x-ray beam, Sc and Sp were determined both by the conventional method and as Scp(mlc=jaw){sup 0.5}. Square field benchmark values of Scp(mlc,jaw) were then measured across the range from 2×2 to 29×29. Both Sc and Sp functions were then evaluated as to their ability to predict these measurements. Results: Both methods produced qualitatively similar results with <4% error for all cases and >3% error in 1 case. The conventional method produced 2 cases with >2% error, while the squareroot method produced only 1 such case. Conclusion: Though it would need to be validated for any specific beam to which it might be applied, under the conditions studied, the simplifying assumption that Sc = Sp is justified.

07 ISOTOPE AND RADIATION SOURCES↗

Sci—Fri AM: Mountain — 01: Validation of a new formulism and the related correction factors on output factor determination for small photon fields

Small field dosimetry measurements including output factors are difficult due to lack of charged-particle equilibrium, occlusion of the radiation source, the finite size of detectors, and non-water equivalence of detector components. With available detectors significant variations could be measured that will lead to incorrect delivered dose to patients. IAEA/AAPM have provided a framework and formulation to correct the detector response in small photon fields. Monte Carlo derived correction factors for some commonly used small field detectors are now available, however validation has not been performed prior to this study. An Exradin A16 chamber, EDGE detector and SFD detector were used to perform the output factor measurement for a series of conical fields (5–30mm) on a Varian iX linear accelerator. Discrepancies up to 20%, 10% and 6% were observed for 5, 7.5 and 10 mm cones between the initial output factors measured by the EDGE detector and the A16 ion chamber, while the discrepancies for the conical fields larger than 10 mm were less than 4%. After the application of the correction, the output factors agree well with each other to within 1%. Caution is needed when determining the output factors for small photon fields, especially for fields 10 mm in diameter or smaller. More than one type of detector should be used, each with proper corrections applied to the measurement results. It is concluded that with the application of correction factors to appropriately chosen detectors, output can be measured accurately for small fields.

60 APPLIED LIFE SCIENCES↗

Use of regularized principal component analysis to model anatomical changes during head and neck radiation therapy for treatment adaptation and response assessment

Purpose: To develop standard (SPCA) and regularized (RPCA) principal component analysis models of anatomical changes from daily cone beam CTs (CBCTs) of head and neck (H&N) patients and assess their potential use in adaptive radiation therapy, and for extracting quantitative information for treatment response assessment. Methods: Planning CT images of ten H&N patients were artificially deformed to create “digital phantom” images, which modeled systematic anatomical changes during radiation therapy. Artificial deformations closely mirrored patients’ actual deformations and were interpolated to generate 35 synthetic CBCTs, representing evolving anatomy over 35 fractions. Deformation vector fields (DVFs) were acquired between pCT and synthetic CBCTs (i.e., digital phantoms) and between pCT and clinical CBCTs. Patient-specific SPCA and RPCA models were built from these synthetic and clinical DVF sets. EigenDVFs (EDVFs) having the largest eigenvalues were hypothesized to capture the major anatomical deformations during treatment. Results: Principal component analysis (PCA) models achieve variable results, depending on the size and location of anatomical change. Random changes prevent or degrade PCA’s ability to detect underlying systematic change. RPCA is able to detect smaller systematic changes against the background of random fraction-to-fraction changes and is therefore more successful than SPCA at capturing systematic changes early in treatment. SPCA models were less successful at modeling systematic changes in clinical patient images, which contain a wider range of random motion than synthetic CBCTs, while the regularized approach was able to extract major modes of motion. Conclusions: Leading EDVFs from the both PCA approaches have the potential to capture systematic anatomical change during H&N radiotherapy when systematic changes are large enough with respect to random fraction-to-fraction changes. In all cases the RPCA approach appears to be more reliable at capturing systematic changes, enabling dosimetric consequences to be projected once trends are established early in a treatment course, or based on population models.

60 APPLIED LIFE SCIENCES↗

Electric-field enhancement caused by subwavelength-sized particles located on the surface of multilayer dielectric mirrors

A laser pulse impinging on the surface of an optical component can interact with particles, such as contamination debris, to produce a scattered electric field, which, either by itself or combined with the incident laser field, coherently can significantly increase the local field intensity. This effect can be of critical importance as it can reduce the laser-induced–damage threshold of the affected component. In this work, we use a field-propagation code to improve understanding regarding the factors that determine the magnitude and location of the electric-field enhancement for the case of subwavelength-sized particles located on the surface of multilayer dielectric mirrors.

47 OTHER INSTRUMENTATION↗