Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

TU-FG-BRB-06: A Prompt Gamma-Ray Spectroscopy System for Clinical Studies of in Vivo Proton Range Verification

Purpose: We present a new system to perform prompt gamma-ray spectroscopy during proton pencil-beam scanning treatments, which enables in vivo verification of the proton range. This system will be used for the first clinical studies of this technology. Methods: After successful pre-clinical testing of prompt gamma-ray spectroscopy, a full scale system for clinical studies is now being assembled. Prompt gamma-rays will be detected during patient treatment using an array of 8 detector modules arranged behind a tungsten collimator. Each detector module consists of a lanthanum(III) bromide scintillator, a photomultiplier tube, and custom electronics for stable high voltage supply and signal amplification. A new real-time data acquisition and control system samples the signals from the detectors with analog-to-digital converters, analyses events of interest, and communicates with the beam delivery systems. The timing of the detected events was synchronized to the cyclotron radiofrequency and the pencil-beam delivery. Range verification is performed by matching measured energy- and timeresolved gamma-ray spectra to nuclear reaction models based on the clinical treatment plan. Experiments in phantoms were performed using clinical beams in order to assess the performance of the systems. Results: The experiments showed reliable real-time analysis of more than 10 million detector events per second. The individual detector modules acquired accurate energy- and time-resolved gamma-ray measurements at a rate of 1 million events per second, which is typical for beams delivered with a clinical dose rate. The data acquisition system successfully tracked the delivery of the scanned pencil-beams to determine the location of range deviations within the treatment field. Conclusion: A clinical system for proton range verification using prompt gamma-ray spectroscopy has been designed and is being prepared for use during patient treatments. We anticipate to start a first clinical study in the near future. This work was supported by the Federal Share of program income earned by Massachusetts; General Hospital on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Search for Anomalous Production of Multilepton Events in $pp$ Collisions at $\sqrt{s}=7$ TeV

A search for anomalous production of events with three or more isolated leptons in pp collisions at sqrt(s) = 7 TeV is presented. The data, corresponding to an integrated luminosity of 4.98 inverse femtobarns, were collected by the CMS experiment at the LHC during the 2011 run. The search is applicable to any model of new physics that enhances multiple lepton production. The observed multilepton events are categorized into exclusive search channels based on the identity and kinematics of the objects in the events. An estimate of the standard-model background rates from data is emphasized, but simulation is also used to estimate some of the background rates. The search results are interpreted in the context of supersymmetry, including both R-parity-conserving and R-parity-violating models. We derive exclusion limits as a function of squark, gluino, and chargino masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EdgeAI: Machine learning via direct attached accelerator for streaming data processing at high shot rate x-ray free-electron lasers

We present a case for low batch-size inference with the potential for adaptive training of a lean encoder model. We do so in the context of a paradigmatic example of machine learning as applied in data acquisition at high data velocity scientific user facilities such as the Linac Coherent Light Source-II x-ray Free-Electron Laser. We discuss how a low-latency inference model operating at the data acquisition edge can capitalize on the naturally stochastic nature of such sources. We simulate the method of attosecond angular streaking to produce representative results whereby simulated input data reproduce high-resolution ground truth probability distributions. By minimizing the mean-squared error between the decoded output of the latent representation and the ground truth distributions, we ensure that the encoding layers and resulting latent representation maintains full fidelity for any downstream task, be it classification or regression. We present throughput results for data-parallel inference of various batch sizes, some with throughput exceeding 100 k images per second. We also show in situ training below 10 s per epoch for the full encoder–decoder model as would be relevant for streaming and adaptive real-time data production at our nation’s scientific light sources.

97 MATHEMATICS AND COMPUTING↗

Implementation of Dynamic Extensible Adaptive Locally Exchangeable Measures (IDEALEM) v 0.1

Handling large streaming data is essential for various applications such as network traffic analysis, social networks, energy cost trends, and environment modeling. However, it is in general intractable to store, compute, search, and retrieve large streaming data. This software addresses a fundamental issue, which is to reduce the size of large streaming data and still obtain accurate statistical analysis. As an example, when a high-speed network such as 100 Gbps network is monitored, the collected measurement data rapidly grows so that polynomial time algorithms (e.g., Gaussian processes) become intractable. One possible solution to reduce the storage of vast amounts of measured data is to store a random sample, such as one out of 1000 network packets. However, such static sampling methods (linear sampling) have drawbacks: (1) it is not scalable for high-rate streaming data, and (2) there is no guarantee of reflecting the underlying distribution. In this software, we implemented a dynamic sampling algorithm, based on the recent technology from the relational dynamic bayesian online locally exchangeable measures, that reduces the storage of data records in a large scale, and still provides accurate analysis of large streaming data. The software can be used for both online and offline data records.

Sim, Alex↗

Technical Note: EGSnrc-based dosimetric study of the BEBIG {sup 60}Co HDR brachytherapy sources

Purpose: The purpose of this work is to calculate two-dimensional (2D) dose rate distributions around the BEBIG (Eckert and Ziegler, BEBIG GmbH, Germany) models GK60M21 (old) and Co0.A86 (new) {sup 60}Co high dose rate brachytherapy sources in an unbounded liquid water phantom. The study includes calculation of absorbed dose to water-kerma ratio D/K around the BEBIG sources and a {sup 60}Co point source in water. A comparison is made with previously published data. Methods: The EGSnrcMP Monte Carlo code system is used to calculate the absorbed dose and water-kerma in water and air-kerma strength in vacuum. EGSnrcMP-based user codes such as EDKnrc, FLURZnrc, and DOSRZnrc are employed in the work. Results: The value of D/K reaches a maximum of 1.040{+-}0.002 for the {sup 60}Co point source (constant between 3.6 and 4.5 mm from the source) and 1.076{+-}0.002 for the BEBIG sources (constant between 2.6 and 3.2 mm along the transverse axis of the sources). Dose rate data for the new and old sources are comparable to published data for radial distances r>0.5 cm. Differences up to 9% are observed at points close to the source (r=0.25 cm). In addition for the new source, compared to previously published data, dose rate data are higher by 14% along the longitudinal axis where the source cable is connected. Dose rate differences on the longitudinal axis ({theta}=180 deg.) of this source are explained by varying the length of the simulated source cable. Conclusions: The 2D rectangular data set calculated in the present work could be considered for quality control on radiotherapy treatment planning systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Feasibility of Moving PMU Data in the Future Power Grid

The power grid is a complex network connecting electricity providers with their consumers. With an increasing consumer base requiring more resources and the requirement to integrate significant renewable sources, maintaining the network requires new and innovative management solutions. To manage this complexity and provide precise, real-time views of the grid, Phasor Measurement Units (PMUs) are undergoing widespread deployment. These units provide measurements as often as 60 times per second, with an accurate time identifier attached to each reading, enabling real-time monitoring of the network. However, this new capability generates much more data than the current infrastructure is designed to handle. With the expectation that there will eventually be tens of thousands of PMUs monitoring the transmission lines, the power community is looking towards accumulating multiple terabytes of data per day - several orders of magnitude beyond current data acquisition rates. This has led to questions being raised in the power community about whether or not a significant research effort is required to effectively transfer the volume of information generated by these new data streams. This paper answers that question by comparing a worst-case data generation scenario with several alternative networking protocols and historical trends in protocol advancement. Based on this analysis we are able to conclude that transferring the information between the PMUs and the resulting data repositories is feasible. We recognize that there are issues beyond transferring the data that need to be addressed such as effective access to historical data, data transfer latency, cyber security, and data analysis. There is also an extensive engineering trade-off that the power companies will need to make to decide the best mix of networking protocols for their particular PMU deployments, since that requires significant assumptions about proprietary information including deployment cost, deployment schedules, PMU locations, and available resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

THE CONTINUING OUTBURST OF V1647 ORIONIS: WINTER/SPRING 2011 OBSERVATIONS

We present optical and near-IR observations of the young eruptive variable star V1647 Orionis which illuminates McNeil's Nebula. In late 2003, V1647 Ori was observed to brighten by around 5 mag to r' = 17.7. In early 2006 the star faded back to its quiescent brightness of r' {approx} 23, however in mid-2008 it brightened yet again by {approx}5 mag. Our new observations, taken in early 2011, show V1647 Ori to be in an elevated photometric state with an optical brightness similar to the value found at the start of the 2003 and 2008 outbursts. Optical images taken between 2008 and 2011 suggest that the star has remained in outburst from mid-2008 to the present. H{alpha} and the far-red Ca II triplet lines remain in emission with H{alpha} possessing a significant P Cygni profile. A self-consistent study of the accretion luminosity and rate using data taken in 2004, 2007, 2008, and 2011 indicates that when bright, V1647 Ori has values of 16 {+-} 2 L{sub sun} and (4 {+-} 2) x 10{sup -6} M{sub sun} yr{sup -1}, respectively. We support the premise that the accretion luminosity and rate both declined by a factor of 2-3 during the 5 mag fading in 2007. However, a significant part of the fading was due to either variable extinction or dust reformation. We discuss these new observations in relation to previous published data and the classification schemes for young eruptive variables.

79 ASTRONOMY AND ASTROPHYSICS↗

Writing ROOT Data in Parallel with TBufferMerger

Experiments at the Large Hadron Collider (LHC) produce tens of petabytes of new data in ROOT format per year that need to be processed and analysed. In the next decade, following the planned upgrades of the LHC and its detectors, this data production rate is expected to increase at least ten-fold. Therefore, optimizing the ROOT I/O subsystem is of critical importance to the success of the LHC physics programme. This contribution presents ROOT’s approach for writing data from multiple threads to a single output file in an efficient way. Technical aspects of the implementation—the TBufferMerger class—and programming model examples are described. Measurements of runtime performance and the overall improvement relative to the case of serial data writing are also discussed.

47 OTHER INSTRUMENTATION↗

Risk-Aware Measurement Synchronization and Recovery for DSSE With Heterogeneous Data Sources

Power distribution systems are increasingly integrating heterogeneous sensors with varying data reporting rates and types, which pose challenges to achieving observability at the desired temporal resolution of distribution system state estimation (DSSE). Multisensor failures caused by extreme events exacerbate these issues, introducing substantial uncertainties into DSSE. This article proposes a novel solution to these challenges by ensuring high-resolution system observability despite heterogeneous data sources and multisensor failures. First, a deep learning architecture combining long short-term memory (LSTM) and graph convolutional network (GCN) is employed to synchronize meters with different reporting rates, aiming to achieve system observability. A random-walk-model-based approach is introduced to generate pseudo-measurements while properly characterizing their uncertainties under multisensor failures. Finally, a disaster-risk-informed observability metric (RiOM) is defined to quantify the uncertainty associated with state estimation results. The proposed framework offers deeper insights into the system observability on the fly compared with conventional analysis. The effectiveness of the framework is demonstrated on an IEEE standard test case and a large-scale real-world distribution feeder in mid-Minnesota in the U.S.

97 MATHEMATICS AND COMPUTING↗

A performance study of the time-varying cache behavior: a study on APEX, Mantevo, NAS, and PARSEC

Cache has long been used to minimize the latency of main memory accesses by storing frequently used data near the processor. Processor performance depends on the underlying cache performance. Therefore, significant research has been done to identify the most crucial metrics of cache performance. Although the majority of research focuses on measuring cache hit rates and data movement as the primary cache performance metrics, cache utilization is significantly important. We investigate the application’s locality using cache utilization metrics. In addition, we present cache utilization and traditional cache performance metrics as the program progresses providing detailed insights into the dynamic application behavior on parallel applications from four benchmark suites running on multiple cores. We explore cache utilization for APEX, Mantevo, NAS, and PARSEC, mostly scientific benchmark suites. Our results indicate that 40% of the data bytes in a cache line are accessed at least once before line eviction. Also, on average a byte is accessed two times before the cache line is evicted for these applications. Moreover, we present runtime cache utilization, as well as, conventional performance metrics that illustrate a holistic understanding of cache behavior. To facilitate this research, we build a memory simulator incorporated into the Structural Simulation Toolkit (Rodrigues et al. in SIGMETRICS Perform Eval Rev 38(4):37–42, 2011). Finally, our results suggest that variable cache line size can result in better performance and can also conserve power.

97 MATHEMATICS AND COMPUTING↗

Gaussian processes for autonomous data acquisition at large-scale synchrotron and neutron facilities

The execution and analysis of complex experiments are challenged by the vast dimensionality of the underlying parameter spaces. Although an increase in data-acquisition rates should allow broader querying of the parameter space, the complexity of experiments and the subtle dependence of the model function on input parameters remains daunting owing to the sheer number of variables. New strategies for autonomous data acquisition are being developed, with one promising direction being the use of Gaussian process regression (GPR). GPR is a quick, non-parametric and robust approximation and uncertainty quantification method that can be applied directly to autonomous data acquisition. We review GPR-driven autonomous experimentation and illustrate its functionality using real-world examples from large experimental facilities in the USA and France. We introduce the basics of a GPR-driven autonomous loop with a focus on Gaussian processes, and then shift the focus to the infrastructure that needs to be built around GPR to create a closed loop. Finally, the case studies we discuss show that Gaussian-process-based autonomous data acquisition is a widely applicable method that can facilitate the optimal use of instruments and facilities by enabling the efficient acquisition of high-value datasets.

36 MATERIALS SCIENCE↗

Fatigue crack growth rates of X100 steel welds in high pressure hydrogen gas considering residual stress effects

Fatigue crack growth rate (FCGR) data were measured in high pressure hydrogen gas versus stress intensity factor range (ΔK) in specimens removed from a X100 welded steel pipe. Three distinct regions of the pipe weld were examined: base metal, weld fusion zone, and heat affected zone. Tests were performed at a load ratio (R) of 0.5, frequency of 1 Hz, and at a hydrogen gas pressure of 21 MPa. Tests were also performed in air at 10 Hz as a reference. Fatigue crack growth rates were observed to be over an order of magnitude higher for tests performed in hydrogen compared to the rates from tests in air. Residual stress measurements were collected on identical specimens cut from the base metal, weld, and heat affected zone to account for their influence on measured FCGR data. The slitting method provided residual stress and residual stress intensity factor (K res ), the effect of which was removed from the FCGR data using K norm in order to provide a more direct comparison of crack growth resistance of the base metal, weld and heat affected zone. Prior to accounting for residual stress, FCGR in hydrogen gas appeared to be highest in the weld fusion zone. Furthermore, after accounting for residual stress effects, the weld fusion zone FCGR data converged to the base metal FCGR data, which underscores the importance of accounting for residual stress effects when assessing fatigue performance.

42 ENGINEERING↗

Observation of cold Rb{sub 2} molecules trapped in an optical dipole trap using a laser-pulse-train technique

In this work, we have developed and characterized a laser-pulse-train technique to observe cold Rb{sub 2} molecules trapped in an optical dipole trap. The molecules are produced in a magneto-optical trap, and then loaded into a crossed optical dipole trap. The time evolution of the molecular population is obtained by applying a laser pulse train, which photoionizes the ground-state molecules through intermediate molecular bands. Our results show that this technique allows us to obtain a faster data acquisition rate of the time evolution of the molecule population than other techniques.

74 ATOMIC AND MOLECULAR PHYSICS↗

Elucidation of Ultrafast Decay, Vibrational Beating, and Slow Decay Processes of Excited Azulene

Azulene’s nonradiative decay dynamics and kinetics from its singlet excited-states were studied using mixed-reference spin-flip time-dependent density functional theory (MRSF-TDDFT) combined with trajectory surface-hopping nonadiabatic molecular dynamics (NAMD) and Fermi’s golden rule (FGR) rate theory. The NAMD dynamics reproduce experimental observations that the S 1 → S 0 decay is accelerated and exhibits a crossover from mono- to biexponential kinetics with increasing excess vibrational energy. Minimum-energy-path analyses reveal a continuous S 1 /S 0 conical-intersection seam slightly above the S 1 minimum, providing readily accessible funnels. Time-resolved normal-mode projections reveal selective energy funneling into C–C stretching modes at 1272, 1528, and 1692 cm –1 . Constructive combinations of the latter two modes appear to promote rapid access to the conical-intersection seam, whereas their beating at ∼ 160 fs imposes a natural limit on the decrease of the decay time upon a further increase of excess energies, suggesting that their interference delays the decay. Here, the FGR rate calculation data for the S 1 → S 0 transition reaffirm that the nonradiative decay proceeds mainly near or through the conical intersection, rather than via simple nonadiabatic derivative coupling around the minimum of S 1 . On the other hand, the FGR rates indicate that S 2 decays predominantly to S 0 , as the S 2 –S 1 vibronic coupling is exceptionally weak, which serves as a primary cause for azulene’s characteristic anti-Kasha emission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-A-12A-09: Absolute Blood Flow Measurement in a Cardiac Phantom Using Low Dose CT

Purpose: To investigate a first pass analysis technique to measure absolute flow from low dose CT images in a cardiac phantom. This technique can be combined with a myocardial mass assignment to yield absolute perfusion using only two volume scans and reduce the radiation dose to the patient. Methods: A four-chamber cardiac phantom and perfusion chamber were constructed from poly-acrylic and connected with tubing to approximate anatomical features. The system was connected to a pulsatile pump, input/output reservoirs and power contrast injector. Flow was varied in the range of 1-2.67 mL/s with the pump operating at 60 beats/min. The system was imaged once a second for 14 seconds with a 320-row scanner (Toshiba Medical Systems) using a contrast-enhanced, prospective-gated cardiac perfusion protocol. Flow was calculated by the following steps: subsequent images of the perfusion volume were subtracted to find the contrast entering the volume; this was normalized by an upstream, known volume region to convert Hounsfield (HU) values to concentration; this was divided by the subtracted images time difference. The technique requires a relatively stable input contrast concentration and no contrast can leave the perfusion volume before the flow measurement is completed. Results: The flow calculated from the images showed an excellent correlation with the known rates. The data was fit to a linear function with slope 1.03, intercept 0.02 and an R{sup 2} value of 0.99. The average root mean square (RMS) error was 0.15 mL/s and the average standard deviation was 0.14 mL/s. The flow rate was stable within 7.7% across the full scan and served to validate model assumptions. Conclusion: Accurate, absolute flow rates were measured from CT images using a conservation of mass model. Measurements can be made using two volume scans which can substantially reduce the radiation dose compared with current dynamic perfusion techniques.

60 APPLIED LIFE SCIENCES↗

Fluidization Regime Mapping Analysis for 200 μm Glass Beads in a Circulating Fluidized Bed Riser

Powerpoint slides for an oral presentation at the 2024 Clearwater Clean Energy Conference. It includes a brief discussion of a recently developed non-dimensional map for scaling circulating fluidized bed risers using velocity and solids circulation rate ratios. Data is presented for a set of experiments conducted in NETL’s 12-inch cold flow circulating fluidized bed (CFCFB) riser with 200 micron diameter glass beads, showing a strong dependance between solids volume fraction profiles and the solids circulation rate ratio.

Rowan, Steven↗

Fluidization Regime Mapping Analysis for 200 μm Glass Beads in a Circulating Fluidized Bed Riser

This paper was an executive summary for an oral presentation to be included in the conference proceedings of the 2024 Clearwater Clean Energy Conference. It includes a brief discussion of a recently developed non-dimensional map for scaling circulating fluidized bed risers using velocity and solids circulation rate ratios. Data is presented for a set of experiments conducted in NETL’s 12-inch cold flow circulating fluidized bed (CFCFB) riser with 200 micron diameter glass beads, showing a strong dependance between solids volume fraction profiles and the solids circulation rate ratio.

Rowan, Steven↗

Deriving the Intrahepatic Arteriovenous Shunt Rate from CT Images and Biochemical Data Instead of from Arterial Perfusion Scintigraphy in Hepatic Arterial Infusion Chemotherapy

The purpose of the present study was to elucidate a method for predicting the intrahepatic arteriovenous shunt rate from computed tomography (CT) images and biochemical data, instead of from arterial perfusion scintigraphy, because adverse exacerbated systemic effects may be induced in cases where a high shunt rate exists. CT and arterial perfusion scintigraphy were performed in patients with liver metastases from gastric or colorectal cancer. Biochemical data and tumor marker levels of 33 enrolled patients were measured. The results were statistically verified by multiple regression analysis. The total metastatic hepatic tumor volume (V{sub metastasized}), residual hepatic parenchyma volume (V{sub residual}; calculated from CT images), and biochemical data were treated as independent variables; the intrahepatic arteriovenous (IHAV) shunt rate (calculated from scintigraphy) was treated as a dependent variable. The IHAV shunt rate was 15.1 {+-} 11.9%. Based on the correlation matrixes, the best correlation coefficient of 0.84 was established between the IHAV shunt rate and V{sub metastasized} (p < 0.01). In the multiple regression analysis with the IHAV shunt rate as the dependent variable, the coefficient of determination (R{sup 2}) was 0.75, which was significant at the 0.1% level with two significant independent variables (V{sub metastasized} and V{sub residual}). The standardized regression coefficients ({beta}) of V{sub metastasized} and V{sub residual} were significant at the 0.1 and 5% levels, respectively. Based on this result, we can obtain a predicted value of IHAV shunt rate (p < 0.001) using CT images. When a high shunt rate was predicted, beneficial and consistent clinical monitoring can be initiated in, for example, hepatic arterial infusion chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗