Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Optimizing disk registration algorithms for nanobeam electron diffraction strain mapping

Scanning nanobeam electron diffraction strain mapping is a technique by which the positions of diffracted disks sampled at the nanoscale over a crystalline sample can be used to reconstruct a strain map over a large area. However, it is important that the disk positions are measured accurately, as their positions relative to a reference are directly used to calculate strain. Here in this study, we compare several correlation methods using both simulated and experimental data in order to directly probe susceptibility to measurement error due to non-uniform diffracted disk illumination structure. We found that prefiltering the diffraction patterns with a Sobel filter before performing cross correlation or performing a square-root magnitude weighted phase correlation returned the best results when inner disk structure was present. Lastly, we have tested these methods both on simulated datasets, and experimental data from unstrained silicon as well as a twin grain boundary in 304 stainless steel.

36 MATERIALS SCIENCE↗

A reference-area-free strain mapping method using precession electron diffraction data

Here, in this work, we developed a method using precession electron diffraction data to map the residual elastic strain at the nano-scale. The diffraction pattern of each pixel was first collected and denoised. Template matching was then applied using the center spot as the mask to identify the positions of the diffraction disks. Statistics of distances between the selected diffracted disks enable the user to make an informed decision on the reference and to generate strain maps. Strain mapping on an unstrained single crystal sapphire shows the standard deviation of strain measurement is 0.5%. With this method, we were able to successfully measure and map the residual elastic strain in VO 2 on sapphire and martensite in a Ni 50.3 Ti 29.7 Hf 20 shape memory alloy. This approach does not require the user to select a “strain-free area” as a reference and can work on datasets even with the crystals oriented away from zone axes. This method is expected to provide a robust and more accessible alternative means of studying the residual strain of various material systems that complements the existing algorithms for strain mapping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron X-ray diffraction study of double perovskites Sr 2 R NbO 6 ( R = Sm, Gd, Dy, Ho, Y, Tm, and Lu)

A series of double-perovskite oxides, Sr 2 R NbO 6 ( R = Sm, Gd, Dy, Ho, Y, Tm, and Lu) were prepared and their crystal structure and powder diffraction reference patterns were determined using the Rietveld analysis technique. The crystal structure of each of the Sr 2 R NbO 6 phase is reported in this paper. The R = Gd, Ho, and Lu samples were studied using synchrotron radiation, while R = Sm, Dy, Y, and Tm samples were studied using laboratory X-ray diffraction. Members of Sr 2 R NbO 6 are monoclinic with a space group of P 2 1 / n and are isostructural with each other. Following the trend of “lanthanide contraction”, from R = Sm to Lu, the lattice parameters “ a ” of these compounds decreases from 5.84672(10) to 5.78100(3) Å, b from 5.93192(13) to 5.80977(3) Å, c from 8.3142(2) to 8.18957(5) Å, and V decreases from 288.355(11) to 275.057(2) Å 3 . In this double-perovskite series, the R 3+ and Nb 5+ ions are structurally ordered. The average Nb–O bond length is nearly constant, while the average R –O bond length decreases with the decreasing ionic radius of R 3+ . Powder diffraction patterns for these compounds have been submitted to the Powder Diffraction File (PDF).

36 MATERIALS SCIENCE↗

Grazing-Angle Neutron Diffraction Study of the Water Distribution in Membrane Hemifusion: From the Lamellar to Rhombohedral Phase

The water distribution between lipid bilayers is important in understanding the role of the hydration force at different steps of the membrane fusion pathway. Here in this study, we used grazing-angle neutron diffraction to map out the water distribution in lipid bilayers transiting from a lamellar structure to the hemifusion “stalk” structure in a rhombohedral phase. Under osmotic pressure exerted by different levels of relative humidity, the lipid membrane sample was maintained in equilibrium at different lattices suitable for neutron diffraction. The D 2 O used to hydrate the lipid membrane sample stood out from the lipid in the reconstructed structure because of its much higher coherent neutron scattering length density. The density map indicates that water dissociated from the headgroup in the lamellar phase. In the rhombohedral phase, water was significantly reduced and was squeezed into pockets around the stalk. This study complements earlier structural studies by grazing-angle X-ray diffraction, which is sensitive to only the parts of the structure with high electron density (such as phosphors). The experiment also demonstrated that the recently developed time-of-flight small-angle neutron scattering beamline at the Spallation Neutron Source is suitable for grazing-angle neutron diffraction to provide the structures of large unit cells on the order of a few nanometers, such as biomembrane structures.

59 BASIC BIOLOGICAL SCIENCES↗

High-Temperature Neutron Diffraction Study of Vanadium and Vanadium–Niobium Null-Matrix Alloy for Spectrum Normalization

This study systematically evaluates a vanadium–niobium (V 94.1 Nb 5.9 ) null-matrix alloy as a reference material for neutron spectrum normalization and compares its performance with that of pure vanadium under identical experimental conditions. Neutron diffraction experiments are conducted on the VULCAN Engineering Materials Diffractometer at the Spallation Neutron Source, Oak Ridge National Laboratory, over a temperature range from room temperature to 1200 °C under vacuum. Pure vanadium exhibited distinct Bragg peaks across all temperatures, with its diffraction behavior influenced by both sample orientation and temperature. As the temperature increased, the diffraction peaks shifted to larger d-spacings and decreased in intensity, while spectral deviation near d ≈ 2.8 Å exceeded 10% at 1200 °C. In contrast, the V–Nb alloy produced a nearly featureless spectrum over the full d-spacing range, confirming near-complete cancellation of coherent scattering over the wide temperature range. Its spectra were insensitive to sample orientation, temperature, and microstructural evolution, with spectral deviation around d ≈ 2.8 Å exceeded 5% at 1200 °C. In conclusion, these results demonstrate that the V–Nb null-matrix alloy provides a thermally stable, efficient, and reliable normalization standard for time-of-flight diffractometers or other instrument where it is needed, enabling reduced data acquisition time and improved data quality in high-temperature neutron diffraction experiments.

Alloys↗

Powder diffraction

Powder diffraction is a non-destructive technique, which is experimentally simple in principle. Because the physics behind diffraction is well understood, an exceptionally large amount of information can be obtained from a single measurement. The positions and relative intensities of the peaks yield a fingerprint that can be used for qualitative phase analysis. Quantitative phase analysis can be obtained by detailed analysis of the intensities. Unit cells can be derived from the peak positions. Crystal structures can be solved using powder diffraction data and refined by the Rietveld method. The peak profiles contain information about crystallite size, strain and nanostructure. Non-idealities in the intensities give information on texture. Abandoning the crystallographic model provides information about local structure, by pair distribution function analysis. For powder diffraction, everything is a sample; the technique is commonly applied to characterize minerals, ceramics, metals and alloys, catalysts, polymers, pharmaceuticals, organic compounds, environmental and forensic samples, among others. The major features of contemporary laboratory powder diffractometers are described. Methods for obtaining suitable powder specimens are summarized. Major applications of qualitative and quantitative phase analysis, structure solution, size/strain/nanostructure analysis using peak profiles, texture analysis and pair distribution function analysis are introduced.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Empirically testing vaterite structural models using neutron diffraction and thermal analysis

Otoliths, calcium carbonate (CaCO 3 ) ear bones, are among the most commonly used age and growth structures of fishes. Most fish otoliths are comprised of the most dense CaCO 3 polymorph, aragonite. Sturgeon otoliths, in contrast, have been characterized as the rare and structurally enigmatic polymorph, vaterite a metastable polymorph of CaCO 3 . Vaterite is an important material ranging from biomedical to personal care applications although its crystal structure is highly debated. We characterized the structure of sturgeon otoliths using thermal analysis and neutron powder diffraction, which is used non-destructively. We confirmed that while sturgeon otoliths are primarily composed of vaterite, they also contain the denser CaCO 3 polymorph, calcite. For the vaterite fraction, neutron diffraction data provide enhanced discrimination of the carbonate group compared to x-ray diffraction data, owing to the different relative neutron scattering lengths, and thus offer the opportunity to uniquely test the more than one dozen crystal structural models that have been proposed for vaterite. Of those, space group P6 5 22 model, a = 7.1443(4)Å , c = 25.350(4)Å , V = 1121.5(2)Å 3 provides the best fit to the neutron powder diffraction data, and allows for a structure refinement using rigid carbonate groups.

60 APPLIED LIFE SCIENCES↗

Advanced x-ray stress analysis method for a single crystal using different diffraction plane families

Generalized formula of the x-ray stress analysis for a single crystal with unknown stress-free lattice parameter was proposed. This method enables us to evaluate the plane stress states with any combination of diffraction planes. We can choose and combine the appropriate x-ray sources and diffraction plane families, depending on the sample orientation and the apparatus, whenever diffraction condition is satisfied. The analysis of plane stress distributions in an iron single crystal was demonstrated combining with the diffraction data for Fe{l_brace}211{r_brace} and Fe{l_brace}310{r_brace} plane families.

36 MATERIALS SCIENCE↗

Diffractive-refractive optics: X-ray collimator

Diffractive-refractive optics are x-ray focusing monochromators based on the diffraction on profiled crystal surface. Diffraction on longitudinal parabolic groove machined in crystal surface forms a sagittaly focused synchrotron radiation beam. Such kind of monochromator may be realized as a crystal with parabolic hole, where the beam is diffracted on the inner wall of the hole. Two such asymmetrically cut crystals set into antiparallel position, creating a dispersive (+,-,-,+) arrangement, form a sagittaly focusing x-ray monochromator which should be practically aberration-free. The focusing properties of such kind of monochromator are discussed in detail and it is shown for the first time that it can be used not only for focusing but also for creating highly parallel monochromatic beam in the broad region of the Bragg angles. This device with parabolic hole has not been tested experimentally yet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new large radius imaging plate camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by multiexposure method

A new large radius imaging plate diffraction camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by means of multiple exposures has been developed for an insertion device beamline of SPring-8, Japan. The new imaging plate camera consists of a large radius cylindrical shape imaging plate cassette that is 400 mm in length and 954.9 mm in cylinder radius. The cassette is designed to be mounted on the 2{theta} arm of the diffractometer of BL15XU in SPring-8. One imaging plate covers 24 deg. and several times of exposure changing the 2{theta}-setting angle is necessary to obtain whole powder diffraction data up to a high angle region. One pixel of the imaging plate corresponds to 0.003 deg. in 2{theta} when the readout pixel size is 50 {mu}m squares. Separately collected data are translated to 2{theta}-intensity format and are connected by comparing the peak and background intensity included in the overlapped area. The exposure time is less than 120 s for most samples and the readout time is about 3 min; thus, the total measurement time for one powder diffraction pattern is less than 20 min. The measurement time is the same order as the continuous 2{theta}-scanning method of the third generation synchrotron powder diffractometer. The angular resolution of the new imaging plate camera was evaluated by comparing the full width at half maximum of the 111 reflection of NBS-Si. The observed angular resolution is not so high as a powder diffractometer with a Si or a Ge analyzer monochromator in the third generation synchrotron facility but higher than a powder diffractometer with a Ge analyzer monochromator at a bending magnet beamline of the second generation synchrotron. The Rietveld analysis of NBS-CeO{sub 2} was successfully carried out with the data taken by the new imaging plate camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theory of ultrafast electron diffraction: The role of the electron bunch properties

We present a general formalism for scattering of electron bunches used in ultrafast electron diffraction experiments. To perform the scattering calculation, we associate the classical distribution function that describes the electron bunch just before scattering with the asymptotic-in Wigner distribution. Using single scattering and far-field approximations, we derive an expression for the diffracted signal and discuss the effects of the different bunch parameters on the measured diffracted flux. We identify the transverse and longitudinal coherence lengths and discuss the importance of these length scales in diffraction pattern formation. We present sample numerical calculations for scattering by nanosize particles based on our model and discuss the results in terms of bunch and scattering target parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electro-optic sampling for time resolving relativistic ultrafast electron diffraction

The Pegasus laboratory at UCLA features a state-of-the-art electron photoinjector capable of producing ultrashort (<100 fs) high-brightness electron bunches at energies of 3.75 MeV. These beams recently have been used to produce static diffraction patterns from scattering off thin metal foils, and it is foreseen to take advantage of the ultrashort nature of these bunches in future pump-probe time-resolved diffraction studies. In this paper, single shot 2-d electro-optic sampling is presented as a potential technique for time of arrival stamping of electron bunches used for diffraction. Effects of relatively low bunch charge (a few 10's of pC) and modestly relativistic beams are discussed and background compensation techniques to obtain high signal-to-noise ratio are explored. From these preliminary tests, electro-optic sampling is suitable to be a reliable nondestructive time stamping method for relativistic ultrafast electron diffraction at the Pegasus lab.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffractive processes in electron-proton and proton-proton collisions

In this paper we give a brief description of diffractive processes. We focus on ep collisions at HERA and outline key features of exclusive diffraction in hadron-hadron collision. We discuss respectively: diffractive parton distributions of the proton obtained from DGLAP fits to HERA data, including the twist-4 contribution, afterwards diffractive charm production from dipole model and at the end shortly exclusive production of a Higgs boson in pp scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffraction-controlled backscattering threshold and application to Raman gap

In most classic analytical models of linear stimulated scatter, light diffraction is omitted, a priori. However, modern laser optic typically includes a variant of the random phase plate [Y. Kato et al., Phys. Rev. Lett. 53, 1057 (1984)], resulting in diffraction limited laser intensity fluctuations - or localized speckles - which may result in explosive reflectivity growth as the average laser intensity approaches a critical value [H. A. Rose and D. F. DuBois, Phys. Rev. Lett. 72, 2883 (1994)]. Among the differences between stimulated Raman scatter (SRS) and stimulated Brillouin scatter is that the SRS scattered light diffracts more strongly than the laser light with increase of electron density. This weakens the tendency of the SRS light to closely follow the most amplified paths, diminishing gain. Let G{sub 0} be the one-dimensional power gain exponent of the stimulated scatter. In this paper we show that differential diffraction gives rise to an increase of G{sub 0} at the SRS physical threshold with increase of electron density up to a drastic disruption of SRS as electron density approaches one fourth of its critical value from below. For three wave interaction lengths not small compared to a speckle length, this is a physically robust Raman gap mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single and Central Diffractive Higgs Production at the LHC

The single and central diffractive production of the Standard Model Higgs boson is computed using the diffractive factorization formalism, taking into account a parametrization for the Pomeron structure function provided by the H1 Collaboration. We compute the cross sections at NLO accuracy for the gluon fusion process, since it is the leading mechanism for the Higgs boson production. The gap survival probability is also introduced to include the rescattering corrections due to spectator particles present in the interaction. The diffractive ratios are predicted for proton-proton collisions at the LHC, since the beam luminosity is favorable to the Higgs boson detection. These results provide updated estimations for the fraction of single and central diffractive events in the LHC kinematical regime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffractive heavy quark production in AA collisions at the LHC at NLO

The single and double diffractive cross sections for heavy quarks production are evaluated at NLO accuracy for hadronic and heavy ion collisions at the LHC. Diffractive charm and bottom production is the main subject of this work, providing predictions for CaCa, PbPb and pPb collisions. The hard diffraction formalism is considered using the Ingelman-Schlein model where a recent parametrization for the Pomeron structure function (DPDF) is applied. Absorptive corrections are taken into account as well. The diffractive ratios are estimated and theoretical uncertainties are discussed. Comparison with competing production channels is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Online in situ x-ray diffraction setup for structural modification studies during swift heavy ion irradiation

The high energy density of electronic excitations due to the impact of swift heavy ions can induce structural modifications in materials. We present an x-ray diffractometer called ALIX (''Analyse en Ligne sur IRRSUD par diffraction de rayons X''), which has been set up at the low-energy beamline (IRRadiation SUD - IRRSUD) of the Grand Accelerateur National d'Ions Lourds facility, to allow the study of structural modification kinetics as a function of the ion fluence. The x-ray setup has been modified and optimized to enable irradiation by swift heavy ions simultaneously to x-ray pattern recording. We present the capability of ALIX to perform simultaneous irradiation-diffraction by using energy discrimination between x-rays from diffraction and from ion-target interaction. To illustrate its potential, results of sequential or simultaneous irradiation-diffraction are presented in this article to show radiation effects on the structural properties of ceramics. Phase transition kinetics have been studied during xenon ion irradiation of polycrystalline MgO and SrTiO{sub 3}. We have observed that MgO oxide is radiation-resistant to high electronic excitations, contrary to the high sensitivity of SrTiO{sub 3}, which exhibits transition from the crystalline to the amorphous state during irradiation. By interpreting the amorphization kinetics of SrTiO{sub 3}, defect overlapping models are discussed as well as latent track characteristics. Together with a transmission electron microscopy study, we conclude that a single impact model describes the phase transition mechanism.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Central diffraction in proton-proton collisions at {radical}(s) = 7TeV with ALICE at LHC

A double-gap topology is used for filtering central-diffractive events from a protonproton minimum-bias data sample at a centre-of-mass energy Central diffraction in proton-proton collisions at {radical}(s) = 7TeV. This topology is defined by particle activity in the ALICE central barrel and absence of particle activity outside. The fraction of events satisfying the double-gap requirement R{sub DG} is found to be 7.63{+-}0.02(st at.){+-}0.87(syst.) Multiplication-Sign 10{sup -4}. The background of this double-gap fraction is estimated by studying the contributions of non-diffractive, single-and double-diffractive dissociation processes as modelled by Monte Carlo event generators, and is found to be about 10%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗