Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital data acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

An Investigation of Surge in a High-Speed Centrifugal Compressor Using Digital PIV

Compressor stall is a catastrophic breakdown of the flow in a compressor, which con lead to a loss of engine power, large pressure transients in the inlet/nacelle, and engine flameout. The implementation of active or passive strategies for controlling rotating stall and surge can significantly extend the stable operating range of a compressor without substantially sacrificing performance. It is crucial to identify the dynamic changes occurring in the flow field prior to rotating stall and surge in order to control these events successfully. Generally, pressure transducer measurements are made to capture the transient response of a compressor prior to rotating stall. In this investigation, Digital Particle Imaging Velocimetry (DPIV) is used in conjunction with dynamic pressure transducers to capture transient velocity and pressure measurements simultaneously in the nonstationary flow field during compressor surge. DPIV is an instantaneous, planar measurement technique that is ideally suited for studying transient flow phenomena in highspeed turbomachinery and has been used previously to map the stable operating point flow field in the diffuser of a high-speed centrifugal compressor. Through the acquisition of both DPIV images and transient pressure data, the time evolution of the unsteady flow during surge is revealed.

Wernet, Mark P.↗

Avionics for a Small Robotic Inspection Spacecraft

A report describes the tentative design of the avionics of the Mini-AERCam -- a proposed 7.5-in. (approximately 19-cm)-diameter spacecraft that would contain three digital video cameras to be used in visual inspection of the exterior of a larger spacecraft (a space shuttle or the International Space Station). The Mini-AERCam would maneuver by use of its own miniature thrusters under radio control by astronauts inside the larger spacecraft. The design of the Mini-AERCam avionics is subject to a number of constraints, most of which can be summarized as severely competing requirements to maximize radiation hardness and maneuvering, image-acquisition, and data-communication capabilities while minimizing cost, size, and power consumption. The report discusses the design constraints, the engineering approach to satisfying the constraints, and the resulting iterations of the design. The report places special emphasis on the design of a flight computer that would (1) acquire position and orientation data from a Global Positioning System receiver and a microelectromechanical gyroscope, respectively; (2) perform all flight-control (including thruster-control) computations in real time; and (3) control video, tracking, power, and illumination systems.

Abbott, Larry↗

SU-E-J-251: Fast MR-Based DRR Generation Using Highly Undersampled 3D Radial Trajectories

Purpose: The construction of a digitally reconstructed radiograph (DRR) from a magnetic resonance image (MRI) is possible if the cortical bone signal can be acquired and separated from air and soft tissue. This may be accomplished by subtracting a long echo-time, in-phase, gradient echo (GRE) image volume from an ultra-short echo time free induction decay (FID) image to produce a bone-enhanced (BE) image that reveals cortical bone. One limitation of this approach is the length of time required for data acquisition, which can limit the quality of the DRRs due to patient and organ motion. This study aimed to significantly reduce the acquisition time without compromising DRR quality. Methods: Brain data were acquired from two volunteers using a 3T MR scanner (Ingenia, Philips Healthcare). The FID and GRE images were acquired in a single acquisition using a 3D radial readout sequence with the following parameters: TE1=0.142ms (ultra-short), TE2=2.197ms (nearly in-phase), 2*2*2mm3 isotropic voxels, 250*250*250mm3 FOV. To reduce the acquisition time, k-space was sampled at 75, 50 and 25% of a full 3D sphere . The TE2 image was subtracted from the TE1 image to generate the BE images. The BE images were used to generate DRRs using the Pinnacle treatment planning system (Philips-version 9.2). The quality of the DRRs was evaluated qualitatively by 5 board certified medical physicists for clinical usefulness. Results: The acquisition time for 75, 50 and 25% sampling schemes were 219s, 146s, and 73s, respectively, the latter of which was a four-fold reduction in scan time compared to a 300s fully-sampled acquisition. All DRRs obtained were of acceptable quality and were shown to have sufficient information for clinical 2D image matching. Conclusion: Undersampling k-space while maintaining the same range of frequency information results in significantly reduced scan time and clinically acceptable DRR image quality. Drs. B Traughber and R Muzic have research support from Philips Healthcare. Drs. M Traughber and L Hu are employees of Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

EXSCLAIM!

Due to recent improvements in image resolution and acquisition speed, materials microscopy is experiencing an explosion of published imaging data. The standard publication format, while sufficient for traditional data ingestion scenarios where a select number of images can be critically examined and curated manually, is not conducive tolarge-scale data aggregation or analysis, hindering data sharing and reuse. Most images in publications are presented as components of a larger figure with their explicit context buried in the main body or caption text, so even if aggregated, collections of images with weak or no digitized contextual labels have limited value. To solve the problem of curating labeled microscopy data from literature, we introduce the EXSCLAIM! Python toolkit for the automatic EXtraction, Separation, and Caption-based natural Language Annotation of IMages from scientific literature. The software is implemented through a three part pipeline: the JournalScraper, which searches the web and downloads figures and captions based on a user provided query, the CaptionDistributor, which separates caption text based on the subfigure each portion of the caption refers to, and the FigueSeparator, which separates figures into component subfigures and extracts other visual information. Also included is a Django user interface for exploring the resulting dataset.

CHAN, MARIA↗

An Investigation of Surge in a High-Speed Centrifugal Compressor Using Digital PIV

Compressor stall is a catastrophic breakdown of the flow in a compressor, which can lead to a loss of engine power, large pressure transients in the inlet/nacelle and engine flameout. The implementation of active or passive strategies for controlling rotating stall and surge can significantly extend the stable operating range of a compressor without substantially sacrificing performance. It is crucial to identify the dynamic changes occurring in the flow field prior to rotating stall and surge in order to successfully control these events. Generally, pressure transducer measurements are made to capture the transient response of a compressor prior to rotating stall. In this investigation, Digital Particle Imaging Velocimetry (DPIV) is used in conjunction with dynamic pressure transducers to simultaneously capture transient velocity and pressure measurements in the non-stationary flow field during compressor surge. DPIV is an instantaneous, planar measurement technique which is ideally suited for studying transient flow phenomena in high speed turbomachinery and has been used previously to successfully map the stable operating point flow field in the diffuser of a high speed centrifugal compressor. Through the acquisition of both DPIV images and transient pressure data, the time evolution of the unsteady flow during surge is revealed.

Wernet, Mark P.↗

Boreal canopy surfaces from spaceborne stereogrammetry

Surface elevation estimates from high resolution spaceborne image (HRSI) stereogrammetry are used to examine fine-scaled structure of boreal forest canopies. These data can depict detailed spatial patterns of vertical forest structure at remote sites across the circumpolar domain where these estimates would otherwise be unavailable. This work examines where these estimates are most effective at describing vertical forest structure to explain which canopy surfaces they represent. We evaluated the variation in canopy surface estimates captured from four general types of HRSI digital surface models (DSMs) across the full range of boreal canopy cover. These DSMs, classified into 4 types by grouping them according to the acquisition's (1) sun elevation angle (low or high) and (2) seasonality-driven ground surface condition (snow presence/absence), vary with acquisition characteristics and the details of this variation continues to be studied. We explored some of this variation by comparing the distributions of differences in boreal canopy percentile heights derived from reference small footprint lidar in Tanana Valley, Alaska with canopy surface elevations derived from these 4 types of HRSI DSMs. We examined how canopy surface estimates from HRSI DSMs differ according to acquisition characteristics and canopy cover, and ultimately which canopy surfaces are represented in these DSMs. Our results help clarify which boreal canopy surfaces are representative of those captured with HRSI DSMs. They show that in the Tanana Valley (1) DSMs grouped by sun elevation angle and ground surface condition provide different surface estimates of boreal canopies; (2) the two DSM types that appear to most differently capture boreal forest canopy surfaces are DSMs from snow-free images acquired at sun elevation angles <30° (Low sun elev. & snow-free) and those with snow-cover at sun elevation angles ≥30° (High sun elev. & snow-free); (3) DSMs with snow most often do not capture upper canopy surfaces; (4) the “Low sun elev. & snow-free” DSMs resolve surfaces that are most representative of upper canopy surfaces (dense forests >60% cover, 70th–80th percentile heights); and (5) in the most dense forests (>80% cover) where canopy gaps are least likely to bias downward the average surface estimates, the snow-free DSM types are representative of 70th - 80th percentile heights (“Low sun elev. & snow-free”) and 60th–70th percentile heights (“High sun elev. & snow-free”). The combination of horizontal structure (canopy cover) and acquisition characteristics affect the boreal vertical structure (canopy surface height) estimates from spaceborne stereogrammetry. These effects should be considered when analyzing products derived from HRSI DSMs, and as part of a comprehensive approach to spaceborne remote sensing of circumpolar boreal forests.

forest structure↗

Hardware-Based Randomized Encoding for Sensor Authentication in Power Grid SCADA Systems

Supervisory Control and Data Acquisition (SCADA) systems are utilized extensively in critical power grid infrastructures. Modern SCADA systems have been proven to be susceptible to cyber-security attacks and require improved security primitives in order to prevent unwanted influence from an adversarial party. One section of weakness in the SCADA system is the integrity of field level sensors providing essential data for control decisions at a master station. In this paper we propose a lightweight hardware scheme providing inferred authentication for SCADA sensors by combining an analog to digital converter and a permutation generator as a single integrated circuit. Through this method we encode critical sensor data at the time of sensing, so that unencoded data is never stored in memory, increasing the difficulty of software attacks. We show through experimentation how our design stops both software and hardware false data injection attacks occurring at the field level of SCADA systems.

42 ENGINEERING↗

Astronomical and statistical algorithms used in the Space Telescope guide star selection system

The construction of the Space Telescope Guide Star Catalog from digitized Schmidt survey plates covering the entire sky is described. In order to provide sufficient pointing information, the Guide Star Selection System has to contain a catalog of 20 million guide star candidates in the range of 9.0 to 14.5 visual magnitudes. An image inventory process extracts the relevant object data; after photometric and astrometric calibration the data are screened to arrive at suitable guide star candidates. The selection process for a given target takes into account geometric and photometric parameters of the field, scheduling information, and acquisition probabilities for each guide star pair.

Jenkner, H.↗

Micro-XRF for In Situ Geological Exploration of Other Planets

In situ analysis of rock chemistry is a fundamental tool for exploration of planets. To meet this need, a high-spatial-resolution micro x-ray fluorescence (Micro-XRF) instrument was developed that is capable of determining the elemental composition of rocks (elements Na U) with 100 microns spatial resolution, thus providing insight to the composition of features as small as sand grains and individual laminae. The resulting excitation beam is of sufficient intensity that high signal-to-noise punctual spectra are acquired in seconds to a few minutes using an Amptek Silicon Drift Detector (SDD). The instrument features a tightly focused x-ray tube and HVPS developed by Moxtek that provides up to 200 micro-A at 10 to 50 keV, with a custom polycapillary optic developed by XOS Inc. and integrated into a breadboard Micro-XRF (see figure). The total mass of the complete breadboard instrument is 2.76 kg, including mounting hardware, mounting plate, camera, laser, etc. A flight version of this instrument would require less than 5W nominal power and 1.5 kg mass. The instrument includes an Amptek SDD that draws 2.5 W and has a resolution of 135 to 155 eV FWHM at 5.9 keV. It weighs 180 g, including the preamplifier, digital pulse processor, multichannel analyzer, detector and preamp power supplies, and packaging. Rock samples are positioned relative to the instrument by a three-axis arm whose position is controlled by closed-loop translators (mimicking the robotic arm of a rover). The distance from the source to the detector is calculated from the position of a focused laser beam on the sample as imaged by the camera. The instrument enables quick scans of major elements in only 1 second, and rapid acquisition (30 s) of data with excellent signal-to-noise and energy resolution for trace element analysis

Wade, Lawrence A.↗

Real-time in Situ Signal-to-noise Ratio Estimation for the Assessment of Operational Communications Links

The work presented here formulates the rigorous statistical basis for the correct estimation of communication link SNR of a BPSK, QPSK, and for that matter, any M-ary phase-modulated digital signal from what is known about its statistical behavior at the output of the receiver demodulator. Many methods to accomplish this have been proposed and implemented in the past but all of them are based on tacit and unwarranted assumptions and are thus defective. However, the basic idea is well founded, i.e., the signal at the output of a communications demodulator has convolved within it the prevailing SNR characteristic of the link. The acquisition of the SNR characteristic is of the utmost importance to a communications system that must remain reliable in adverse propagation conditions. This work provides a correct and consistent mathematical basis for the proper statistical 'deconvolution' of the output of a demodulator to yield a measure of the SNR. The use of such techniques will alleviate the need and expense for a separate propagation link to assess the propagation conditions prevailing on the communications link. Furthermore, they are applicable for every situation involving the digital transmission of data over planetary and space communications links.

Manning, Robert M.↗

Four dimensional magnetic resonance imaging with retrospective k-space reordering: A feasibility study

Purpose: Current four dimensional magnetic resonance imaging (4D-MRI) techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of a new strategy for 4D-MRI which is based on retrospective k-space reordering. Methods: We simulated a k-space reordered 4D-MRI on a 4D digital extended cardiac-torso (XCAT) human phantom. A 2D echo planar imaging MRI sequence [frame rate (F) = 0.448 Hz; image resolution (R) = 256 × 256; number of k-space segments (N{sub KS}) = 4] with sequential image acquisition mode was assumed for the simulation. Image quality of the simulated “4D-MRI” acquired from the XCAT phantom was qualitatively evaluated, and tumor motion trajectories were compared to input signals. In particular, mean absolute amplitude differences (D) and cross correlation coefficients (CC) were calculated. Furthermore, to evaluate the data sufficient condition for the new 4D-MRI technique, a comprehensive simulation study was performed using 30 cancer patients’ respiratory profiles to study the relationships between data completeness (C{sub p}) and a number of impacting factors: the number of repeated scans (N{sub R}), number of slices (N{sub S}), number of respiratory phase bins (N{sub P}), N{sub KS}, F, R, and initial respiratory phase at image acquisition (P{sub 0}). As a proof-of-concept, we implemented the proposed k-space reordering 4D-MRI technique on a T2-weighted fast spin echo MR sequence and tested it on a healthy volunteer. Results: The simulated 4D-MRI acquired from the XCAT phantom matched closely to the original XCAT images. Tumor motion trajectories measured from the simulated 4D-MRI matched well with input signals (D = 0.83 and 0.83 mm, and CC = 0.998 and 0.992 in superior–inferior and anterior–posterior directions, respectively). The relationship between C{sub p} and N{sub R} was found best represented by an exponential function (C{sub P}=100(1−e{sup −0.18N{sub R}}), when N{sub S} = 30, N{sub P} = 6). At a C{sub P} value of 95%, the relative error in tumor volume was 0.66%, indicating that N{sub R} at a C{sub P} value of 95% (N{sub R,95%}) is sufficient. It was found that N{sub R,95%} is approximately linearly proportional to N{sub P} (r = 0.99), and nearly independent of all other factors. The 4D-MRI images of the healthy volunteer clearly demonstrated respiratory motion in the diaphragm region with minimal motion induced noise or aliasing. Conclusions: It is feasible to generate respiratory correlated 4D-MRI by retrospectively reordering k-space based on respiratory phase. This new technology may lead to the next generation 4D-MRI with high spatiotemporal resolution and optimal tumor contrast, holding great promises to improve the motion management in radiotherapy of mobile cancers.

60 APPLIED LIFE SCIENCES↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping the Rainforest of the Sea: Global Coral Reef Maps for Global Conservation

Coral reefs are the center of marine biodiversity, yet are under threat with an estimated 60% of coral reef habitats considered at risk by the World Resources Institute. The location and extent of coral reefs in the world are the basic information required for resource management and as a baseline for monitoring change. A NASA sponsored partnership between remote sensing scientists, international agencies and NGOs, has developed a new generation of global reef maps based on data collected by satellites. The effort, dubbed the Millennium Coral Reef Map aims to develop new methods for wide distribution of voluminous satellite data of use to the conservation and management communities. We discuss the tradeoffs between remote sensing data sources, mapping objectives, and the needs for conservation and resource management. SeaWiFS data were used to produce a composite global shallow bathymetry map at 1 km resolution. Landsat 7/ETM+ data acquisition plans were modified to collect global reefs and new operational methods were designed to generate the firstever global coral reef geomorphology map. We discuss the challenges encountered to build these databases and in implementing the geospatial data distribution strategies. Conservation applications include a new assessment of the distribution of the world s marine protected areas (UNEPWCMC), improved spatial resolution in the Reefs at Risk analysis for the Caribbean (WRI), and a global basemap for the Census of Marine Life's OBIS database. The Millennium Coral Reef map and digital image archive will pay significant dividends for local and regional conservation projects around the globe. Complete details of the project are available at http://eol.jsc.nasa.gov/reefs.

Robinson, Julie A.↗

Automated Production of Movies on a Cluster of Computers

A method of accelerating and facilitating production of video and film motion-picture products, and software and generic designs of computer hardware to implement the method, are undergoing development. The method provides for automation of most of the tedious and repetitive tasks involved in editing and otherwise processing raw digitized imagery into final motion-picture products. The method was conceived to satisfy requirements, in industrial and scientific testing, for rapid processing of multiple streams of simultaneously captured raw video imagery into documentation in the form of edited video imagery and video derived data products for technical review and analysis. In the production of such video technical documentation, unlike in production of motion-picture products for entertainment, (1) it is often necessary to produce multiple video derived data products, (2) there are usually no second chances to repeat acquisition of raw imagery, (3) it is often desired to produce final products within minutes rather than hours, days, or months, and (4) consistency and quality, rather than aesthetics, are the primary criteria for judging the products. In the present method, the workflow has both serial and parallel aspects: processing can begin before all the raw imagery has been acquired, each video stream can be subjected to different stages of processing simultaneously on different computers that may be grouped into one or more cluster(s), and the final product may consist of multiple video streams. Results of processing on different computers are shared, so that workers can collaborate effectively.

Nail, Jasper↗

Digital receiver simulation

Digital simulation of the data link for the Saturn-Uranus spacecraft design is summarized. The data link is a 40 watt, 400 MegaHertz, 44 bit-a-second link, a power starved link, and uses convolution coding. Aspects of the link of particular interest are atmospheric scintillation and the Doppler to data rate ratio. The major characteristics of the scintillation are modeled in terms of tapped delay lines. A candidate system design and receiver design is developed. A computer flow diagram depicting a routine for the error rate and one for acquisition is presented. Various coding algorithms are analyzed since the convolution code is sensitive to the distribution of error and the actual pattern of the error.

Hinrichs, C.↗

The UOSAT magnetometer experiment

The magnetometer aboard the University of Surrey satellite (UOSAT) and its associated electronics are described. The basic fluxgate magnetometer employed has a dynamic range of plus or minus 8000 nT with outputs digitized by a 12-bit successive approximation A-D converter having a resolution of plus or minus 2 nT. Noise in the 3-13 Hz bandwidth is less than 1 nT. A bias field generator extends the dynamic range to plus or minus 64,000 nT with quantization steps of 8000 nT. The magnetometer experiment is expected to provide information on the secular variation of the geomagnetic field, and the decay rate of the dipole term. Special emphasis will be placed on the acquisition of real time and memory data over the poles which can be correlated with that from Magsat.

Acuna, M. H.↗

A method of determining attitude from magnetometer data only

Presented here is a new algorithm to determine attitude using only magnetometer data under the following conditions: (1) internal torques are known and (2) external torques are negligible. Torque-free rotation of a spacecraft in thruster firing acquisition phase and its magnetic despin in the B-dot mode give typical examples of such situations. A simple analytical formula has been derived in the limiting case of a spacecraft rotating with constant angular velocity. The formula has been tested using low-frequency telemetry data for the Earth Radiation Budget Satellite (ERBS) under normal conditions. Observed small oscillation of body-fixed components of the angular velocity vector near their mean values result in relatively minor errors of approximately 5 degrees. More significant errors come from processing digital magnetometer data. Higher resolution of digitized magnetometer measurements would significantly improve the accuracy of this deterministic scheme. Tests of the general version of the developed algorithm for a free-rotating spacecraft and for the B-dot mode are in progress.

Natanson, G. A.↗

Evaluation of a Variable-Aperture Full-Ring SPECT System using Large-Area Pixelated CZT Modules: A Simulation Study for Brain SPECT Applications

Single photon emission computed tomography (SPECT) scanner using cadmium zinc telluride (CZT) offers improved imaging capability over conventional NaI (Tl)-based SPECT scanner. We aim to demonstrate a full-ring SPECT system design with eight large-area CZT detectors that can be used for a broad spectrum of SPECT radiopharmaceuticals and provides higher sensitivity and better spatial resolution than those of conventional NaI (Tl)-based gamma cameras. A newly-designed full-ring SPECT system is composed of 8 large-area CZT cameras (128 mm × 179.2 mm effective area) that can be independently swiveled around their own axes of rotation independently and can have radial motion for varying aperture sizes that can be adapted to different sizes of imaging volume. Extended projection data were generated by conjoining projections of two adjacent detectors to overcome the limited field-of-view (FOV) by each CZT camera. Using Monte Carlo simulations, we evaluated this new system design with digital phantoms including a Derenzo hot-rod phantom and a Zubal brain phantom. Comparison of performance metrics such as spatial resolution, sensitivity, contrast-to-noise ratio (CNR), and contrast-recovery ratio were made between our design and a conventional SPECT scanner. The proposed scanner could result in up to about 3 times faster in acquisition time over conventional scan time at same acquisition time per step. The spatial resolution of our proposed scanner was similar or better to that of the conventional scanner, and there was significant performance improvement over the conventional scanner particularly in sensitivity (approximately 4 times). Overall, we successfully reconstructed the phantom image for both 99 mTc-based perfusion and 123 I-based dopamine transporter (DaT) brain studies simulated for our new design. In particular, the striatal/background contrast-recovery ratio in 3-to-1 reference ratio was over the 0.8 for the 123 I-based DaT study. In conclusion, we demonstrated the potential of our new full-ring CZT SPECT design, showing improved performance metrics such as improved system sensitivity and CNR while maintaining other important imaging parameters such as spatial resolution.

36 MATERIALS SCIENCE↗