Search NASA⌕ Search

SEARCH · Search NASA

Results for “Display type.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Eye-tracking of nodule detection in lung CT volumetric data

Purpose: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. Methods: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. Results: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25–30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. Conclusions: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.

60 APPLIED LIFE SCIENCES↗

InterSpec v. 1.0.8

SAND2021-4823 O InterSpec decodes and displays gamma radiation data from a variety of handheld, laboratory, and fixed installation detector types. Once loaded, InterSpec provides a means to interactively analyze the data via a peak-based methodology. InterSpec assists with isotope identification and determines the source strength and shielding characteristics of the measured item. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, William↗

InterSpec v. 1.0.9

SAND2021-4823 O InterSpec decodes and displays gamma radiation data from a variety of handheld, laboratory, and fixed installation detector types. Once loaded, InterSpec provides a means to interactively analyze the data via a peak-based methodology. InterSpec assists with isotope identification and determines the source strength and shielding characteristics of the measured item. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, William↗

FALDO: a semantic standard for describing the location of nucleotide and protein feature annotation

Nucleotide and protein sequence feature annotations are essential to understand biology on the genomic, transcriptomic, and proteomic level. Using Semantic Web technologies to query biological annotations, there was no standard that described this potentially complex location information as subject-predicate-object triples. In this paper, we have developed an ontology, the Feature Annotation Location Description Ontology (FALDO), to describe the positions of annotated features on linear and circular sequences. FALDO can be used to describe nucleotide features in sequence records, protein annotations, and glycan binding sites, among other features in coordinate systems of the aforementioned “omics” areas. Using the same data format to represent sequence positions that are independent of file formats allows us to integrate sequence data from multiple sources and data types. The genome browser JBrowse is used to demonstrate accessing multiple SPARQL endpoints to display genomic feature annotations, as well as protein annotations from UniProt mapped to genomic locations. Our ontology allows users to uniformly describe – and potentially merge – sequence annotations from multiple sources. Finally, data sources using FALDO can prospectively be retrieved using federalised SPARQL queries against public SPARQL endpoints and/or local private triple stores.

59 BASIC BIOLOGICAL SCIENCES↗

ImagingReso: A Tool for Neutron Resonance Imaging

ImagingReso is an open-source Python library that simulates the neutron resonance signal for neutron imaging measurements. By defining the sample information such as density, thickness in the neutron path, and isotopic ratios of the elemental composition of the material, this package plots the expected resonance peaks for a selected neutron energy range. Various sample types such as layers of single elements (Ag, Co, etc. in solid form), chemical compounds (UO 3 , Gd 2 O 3 , etc.), or even multiple layers of both types can be plotted with this package. As a result, major plotting features include display of the transmission/attenuation in wavelength, energy, and time scale, and show/hide elemental and isotopic contributions in the total resonance signal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The autophagy receptor NBR1 directs the clearance of photodamaged chloroplasts

The ubiquitin-binding NBR1 autophagy receptor plays a prominent role in recognizing ubiquitylated protein aggregates for vacuolar degradation by macroautophagy. Here, we show that upon exposing Arabidopsis plants to intense light, NBR1 associates with photodamaged chloroplasts independently of ATG7, a core component of the canonical autophagy machinery. NBR1 coats both the surface and interior of chloroplasts, which is then followed by direct engulfment of the organelles into the central vacuole via a microautophagy-type process. The relocalization of NBR1 into chloroplasts does not require the chloroplast translocon complexes embedded in the envelope but is instead greatly enhanced by removing the self-oligomerization mPB1 domain of NBR1. The delivery of NBR1-decorated chloroplasts into vacuoles depends on the ubiquitin-binding UBA2 domain of NBR1 but is independent of the ubiquitin E3 ligases SP1 and PUB4, known to direct the ubiquitylation of chloroplast surface proteins. Compared to wild-type plants, nbr1 mutants have altered levels of a subset of chloroplast proteins and display abnormal chloroplast density and sizes upon high light exposure. We postulate that, as photodamaged chloroplasts lose envelope integrity, cytosolic ligases reach the chloroplast interior to ubiquitylate thylakoid and stroma proteins which are then recognized by NBR1 for autophagic clearance. This study uncovers a new function of NBR1 in the degradation of damaged chloroplasts by microautophagy.

59 BASIC BIOLOGICAL SCIENCES↗

Oceanographic biooptical profiling system

A new oceanographic instrument to measure underwater optical, biological, and physical properties has been designed, built, and used extensively at sea. The new instrument system is a significant advance that permits optimum sampling strategies using ship, aircraft, and satellite optical sensors for ocean research. The design criteria for the biooptical profiling system included the rapid acquisition of data to accommodate shipboard synoptic sampling; the measurement of the necessary parameters for providing appropriate contemporaneous surface data for remote sensors; the compatibility of the data acquisition system with conventional conductivity temperature depth-type cables and winches on the oceanographic fleet; the capability of real-time display of data along with rapid preliminary data reduction at sea. The primary instrument package in this profiling system is a new microprocessor controlled multiwavelength spectroradiometer. A description of the instrument and examples of data are presented.

Smith, R. C.↗

Sandqvist 187 - A dense molecular cloud in Norma

Observations of Sandqvist 187, an elongated dust cloud in the southern constellation Norma are presented and discussed. The cloud contains two Herbig-Haro objects, HH 56 and HH 57. HH 57 currently displays on its NE edge a 17th mag variable star of the FU Ori type. Using the Columbia University 1.2 m millimeter-wave telescope at Cerro Tololo, the region is mapped and an extended CO cloud which envelops and is elongated along the optical dust cloud is found. The position of maximum CO emission coincides with HH 56 and HH 57. Assuming a distance of 0.7 kpc, the total mass of the cloud is found to be close to 500 solar masses. The CO spectra show evidence of a molecular flow. Photographs and CCD images obtained mostly with the CTIO 4 m telescope show the detailed optical structure of the dark cloud's core region. The Herbig-Haro object HH 56 appears to be related to an emission-line star embedded in the small nebula Reipurth 13, not to the FU Ori star in HH 57.

Alvarez, H.↗

The kinetic approach in magnetospheric plasma transport modeling

The need for a kinetic approach in magnetospheric plasma transport problems is reviewed, as are the trends in its recent applications. The need for kinetic modeling is particularly obvious when confronted with the astonishing variety of magnetospheric particle measurements that display compelling energy and pitch angle-related spatial and/or temporal dispersion, and various types of highly non-Maxwellian features in the distribution functions. Global problems in which the kinetic approach has recently been applied include solar wind plasma injection and dispersion over the cusp, substorm particle injection near synchronous orbit, synergistic energization of ionospheric ions into ring current populations by waves and induced electric field-driven convection, and ionospheric outflow from restricted source regions into the magnetosphere. Kinetic modeling can include efforts ranging from test-particle techniques to particle-in-cell studies, and this range is considered here. There are some areas where fluid and kinetic approaches have been combined or patched together, and these will be briefly discussed.

Horwitz, J. L.↗

Optical studies in the holographic ground station

The Holographic Group System (HGS) Facility in rooms 22 & 123, Building 4708 has been developed to provide for ground based research in determining pre-flight parameters and analyzing the results from space experiments. The University of Alabama, Huntsville (UAH) has researched the analysis aspects of the HGS and reports their findings here. Some of the results presented here also occur in the Facility Operating Procedure (FOP), which contains instructions for power up, operation, and powerdown of the Fluid Experiment System (FES) Holographic Ground System (HGS) Test Facility for the purpose of optically recording fluid and/or crystal behavior in a test article during ground based testing through the construction of holograms and recording of videotape. The alignment of the optical bench components, holographic reconstruction and and microscopy alignment sections were also included in the document for continuity even though they are not used until after optical recording of the test article) setup of support subsystems and the Automated Holography System (AHS) computer. The HGS provides optical recording and monitoring during GCEL runs or development testing of potential FES flight hardware or software. This recording/monitoring can be via 70mm holographic film, standard videotape, or digitized images on computer disk. All optical bench functions necessary to construct holograms will be under the control of the AHS personal computer (PC). These include type of exposure, time intervals between exposures, exposure length, film frame identification, film advancement, film platen evacuation and repressurization, light source diffuser introduction, and control of realtime video monitoring. The completed sequence of hologram types (single exposure, diffuse double exposure, etc.) and their time of occurrence can be displayed, printed, or stored on floppy disk posttest for the user.

Workman, Gary L.↗

Fourier domain target transformation analysis in the thermal infrared

Remote sensing uses of principal component analysis (PCA) of multispectral images include band selection and optimal color selection for display of information content. PCA has also been used for quantitative determination of mineral types and abundances given end member spectra. The preliminary results of the investigation of target transformation PCA (TTPCA) in the fourier domain to both identify end member spectra in an unknown spectrum, and to then calculate the relative concentrations of these selected end members are presented. Identification of endmember spectra in an unknown sample has previously been performed through bandmatching, expert systems, and binary classifiers. Both bandmatching and expert system techniques require the analyst to select bands or combinations of bands unique to each endmember. Thermal infrared mineral spectra have broad spectral features which vary subtly with composition. This makes identification of unique features difficult. Alternatively, whole spectra can be used in the classification process, in which case there is not need for an expert to identify unique spectra. Use of binary classifiers on whole spectra to identify endmember components has met with some success. These techniques can be used, along with a least squares fit approach on the endmembers identified, to derive compositional information. An alternative to the approach outlined above usese target transformation in conjunction with PCA to both identify and quantify the composition of unknown spectra. Preprocessing of the library and unknown spectra into the fourier domain, and using only a specific number of the components, allows for significant data volume reduction while maintaining a linear relationship in a Beer's Law sense. The approach taken here is to iteratively calculate concentrations, reducing the number of endmember components until only non-negative concentrations remain.

Anderson, D. L.↗

The VIS-AD data model: Integrating metadata and polymorphic display with a scientific programming language

The VIS-AD data model integrates metadata about the precision of values, including missing data indicators and the way that arrays sample continuous functions, with the data objects of a scientific programming language. The data objects of this data model form a lattice, ordered by the precision with which they approximate mathematical objects. We define a similar lattice of displays and study visualization processes as functions from data lattices to display lattices. Such functions can be applied to visualize data objects of all data types and are thus polymorphic.

Hibbard, William L.↗

Using Videos Derived from Simulations to Support the Analysis of Spatial Awareness in Synthetic Vision Displays

The evaluation of human-centered systems can be performed using a variety of different methodologies. This paper describes a human-centered systems evaluation methodology where participants watch 5-second non-interactive videos of a system in operation before supplying judgments and subjective measures based on the information conveyed in the videos. This methodology was used to evaluate the ability of different textures and fields of view to convey spatial awareness in synthetic vision systems (SVS) displays. It produced significant results for both judgment based and subjective measures. This method is compared to other methods commonly used to evaluate SVS displays based on cost, the amount of experimental time required, experimental flexibility, and the type of data provided.

Boton, Matthew L.↗

Realtime Multichannel System for Beat to Beat QT Interval Variability

The measurement of beat-to-beat QT interval variability (QTV) shows clinical promise for identifying several types of cardiac pathology. However, until now, there has been no device capable of displaying, in real time on a beattobeat basis, changes in QTV in all 12 conventional leads in a continuously monitored patient. While several software programs have been designed to analyze QTV, heretofore, such programs have all involved only a few channels (at most) and/or have required laborious user interaction or offline calculations and postprocessing, limiting their clinical utility. This paper describes a PC-based ECG software program that in real time, acquires, analyzes and displays QTV and also PQ interval variability (PQV) in each of the eight independent channels that constitute the 12lead conventional ECG. The system also processes certain related signals that are derived from singular value decomposition and that help to reduce the overall effects of noise on the realtime QTV and PQV results.

Starc, Vito↗

Robot Teleoperation and Perception Assistance with a Virtual Holographic Display

Teleoperation of robots in space from Earth has historically been dfficult. Speed of light delays make direct joystick-type control infeasible, so it is desirable to command a robot in a very high-level fashion. However, in order to provide such an interface, knowledge of what objects are in the robot's environment and how they can be interacted with is required. In addition, many tasks that would be desirable to perform are highly spatial, requiring some form of six degree of freedom input. These two issues can be combined, allowing the user to assist the robot's perception by identifying the locations of objects in the scene. The zSpace system, a virtual holographic environment, provides a virtual three-dimensional space superimposed over real space and a stylus tracking position and rotation inside of it. Using this system, a possible interface for this sort of robot control is proposed.

asteroid missions↗

Coming of Age: Polarization as a Probe of Plant Canopy Water Status

We tested the hypothesis that the relative water content (RWC) of the sunlit leaves in a plant canopy may be estimated from polarized canopy imagery. Recently (IGARSS, July 27-31, 2015, Milan, Italy), we reported the results of laboratory polarization measurements of single detached leaves during dry down. We found that RWC was linearly related to the ratio of the reflectance of the interior of the leaf and the leaf transmittance. Here we report application of the laboratory results to estimate RWC for sunlit leaves in a plant canopy. Using a commercial-off-the-shelf (COTS) Nikon 810 camera with Nikkor 300 mm lens and Polaroid type HN-22 linear polarizer, we photographed in the principle plane a plant canopy displaying a gradient of water stress and collected, at each of multiple points along the gradient, two images, one with the polarization filter oriented for maximum scene response and a second with the filter oriented for minimum scene response. We converted the digital values in the two images to reflectance factor with reference to images of a white, flat, horizontal Spectralon surface. We classified the polarization imagery, identifying reflecting leaves, transmitting leaves, other sunlit vegetation and shadows. For each image pair we normalized the leaf internal reflectance by dividing by the cosine of the angle of incidence of the sunlight on the leaf, selected the leaf maximum transmittance in the scene and divided to obtain the ratio reflectance/transmittance, which we compared with leaf RWC. We determined the leaf relative water content by harvesting a section of leaf and immediately placing it in a sealed container in an ice chest. Later in the laboratory the leaf sample was weighed, rehydrated, weighed, dried and again weighed. RWC was determined using the standard formula. Our experimental results support our hypothesis, suggesting that the RWC of sunlit leaves in a plant canopy may be estimated from analysis of polarization imagery collected by a COTS camera system. Unlike remotely sensed estimates of canopy equivalent water thickness, our estimates of the RWC of sunlit canopy leaves provide leaf physiological information. We propose RWC estimates based upon sunlit leaves are more relevant to assessing the water status of a plant canopy than would be RWC estimates based upon large FOV canopy measurements.

estimates↗

Evaluation of Alternate Concepts for Synthetic Vision Flight Displays With Weather-Penetrating Sensor Image Inserts During Simulated Landing Approaches

A simulation study was conducted in 1994 at Langley Research Center that used 12 commercial airline pilots repeatedly flying complex Microwave Landing System (MLS)-type approaches to parallel runways under Category IIIc weather conditions. Two sensor insert concepts of 'Synthetic Vision Systems' (SVS) were used in the simulated flights, with a more conventional electro-optical display (similar to a Head-Up Display with raster capability for sensor imagery), flown under less restrictive visibility conditions, used as a control condition. The SVS concepts combined the sensor imagery with a computer-generated image (CGI) of an out-the-window scene based on an onboard airport database. Various scenarios involving runway traffic incursions (taxiing aircraft and parked fuel trucks) and navigational system position errors (both static and dynamic) were used to assess the pilots' ability to manage the approach task with the display concepts. The two SVS sensor insert concepts contrasted the simple overlay of sensor imagery on the CGI scene without additional image processing (the SV display) to the complex integration (the AV display) of the CGI scene with pilot-decision aiding using both object and edge detection techniques for detection of obstacle conflicts and runway alignment errors.

Parrish, Russell V.↗

Diverse Cd{sup II} coordination complexes derived from bromide isophthalic acid binding with auxiliary N-donor ligands

The coordination characteristics of 4-bromoisophthalic acid (4-Br-H{sub 2}ip) have been investigated in a series of Cd{sup II}-based frameworks. Hydrothermal reactions of Cd{sup II} salts and 4-Br-H{sub 2}ip together with flexible or semiflexible N-donor auxiliary ligands resulted in the formation of four three-dimensional coordination complexes with diverse structures: (Cd(bix){sub 0.5}(bix){sub 0.5}(4-Br-ip)]·H{sub 2}O){sub n} (1), [Cd(bbi){sub 0.5}(bbi){sub 0.5}(4-Br-ip)]{sub n} (2), ([Cd(btx){sub 0.5}(4-Br-ip)(H{sub 2}O)]·0.5CH{sub 3}OH·H{sub 2}O){sub n} (3) and ([Cd(bbt){sub 0.5}(4-Br-ip)(H{sub 2}O)]·3·5H{sub 2}O){sub n} (4). These compounds were characterized by elemental analyses, IR spectra, single-crystal and powder X-ray diffraction. They displayed diverse structures depending on the configuration of the 4-connected metal node, the coordination mode of the 4-Br-H{sub 2}ip, the coordination ability and conformationally flexibility of the N-donor auxiliary. Compound 1 exhibits 3-fold interpenetrated 6{sup 6} topology and compound 2 has a 4{sup 12} topology. Compounds 3–4 have similar 3D pillar-layered structures based on 3,4-connected binodal net with the Schläfli symbol of (4·3{sup 8}). The thermal stabilities and photoluminescence properties of them were discussed in detail. - Graphical abstract: Four 3D Cd{sup II} coordination complexes on the basis of 4-bromoisophthalic acid (4-Br-H{sub 2}ip) and two types of flexible (bbi, bbt) and semiflexible (bix, btx) N-donor ligands are prepared. They displayed diverse topology structures of 6{sup 6} (1), 4{sup 12} (2) and 4·3{sup 8} (3−4), depending on the configuration of the 4-connected metal node, the coordination mode of the 4-Br-H{sub 2}ip, the coordination ability and conformationally flexibility of the N-donor auxiliary ligand. - Highlights: • Four 3D Cd{sup II} coordination complexes based on 4-Br-H{sub 2}ip and flexible/semiflexible N-donor ligands have been synthesized. • They displayed diverse topology structures of 6{sup 6} for 1, 4{sup 12} for 2 and 4·3{sup 8} for 3–4. • The structural diversity depends on the configuration of 4-Br-H{sub 2}ip and the coordination behaviors of the auxiliary ligand.

36 MATERIALS SCIENCE↗