Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Simulations of Hayabusa2 Atmospheric Entry and Comparisons with Data from the Imaging Campaign

Results from flow and radiation simulations for the Hayabusa2 Sample Return Capsule (SRC) along its best-estimated trajectory (BET) are presented. Flow fields are first computed at several points along the best-estimated trajectory for a freestream consisting of N2, O2, Ar, CO2, and H2O; the last three are trace species in Earth’s atmosphere. The thermal response of an assumed ablative material is estimated and flow fields are recomputed at each time point with modified surface temperature distributions. The spectral radiance, from the combination of an aeroheated capsule and the high-temperature shock layer around it, is computed on an imaging plane for a given view angle and slant range at each time point. The radiance is transported through the intervening atmosphere between the Hayabusa2 SRC and the observing aircraft and upon integration over solid angle representing the field of view of the instruments converted to a spectral irradiance. The spectral irradiance is convolved with the instrument function to obtain results that can be directly compared with measurement. Fair to good comparisons with measurements required shifting the time coordinate of measurements by 7.5 s. The disagreement between prediction and measurement is substantial after about 72.5 s along the BET. Additional computations seem to support the idea of flow transition over the capsule.

Atmospheric entry↗

Skylab investigation of the upwelling off the Northwest coast of Africa

The upwelling off the NW coast of Africa in the vicinity of Cape Blanc was studied in February - March 1974 from aircraft and in September 1973 from Skylab. The aircraft study was designed to determine the effectiveness of a differential radiometer in quantifying surface chlorophyll concentrations. Photographic images of the S190A Multispectral Camera and the S190B Earth Terrain Camera from Skylab were used to study distributional patterns of suspended material and to locate ocean color boundaries. The thermal channel of the S192 Multispectral Scanner was used to map sea-surface temperature distributions offshore of Cape Blanc. Correlating ocean color changes with temperature gradients is an effective method of qualitatively estimating biological productivity in the upwelling region off Africa.

Szekielda, K. H.↗

Measurement bias in self-heating x-ray free electron laser experiments from diffraction studies of phase transformation in titanium

X-ray self-heating is a common by-product of X-ray Free Electron Laser (XFEL) techniques that can affect targets, optics, and other irradiated materials. Diagnosis of heating and induced changes in samples may be performed using the x-ray beam itself as a probe. However, the relationship between conditions created by and inferred from x-ray irradiation is unclear and may be highly dependent on the material system under consideration. Here, we report on a simple case study of a titanium foil irradiated, heated, and probed by a MHz XFEL pulse train at 18.1 keV delivered by the European XFEL using measured x-ray diffraction to determine temperature and finite element analysis to interpret the experimental data. We find a complex relationship between apparent temperatures and sample temperature distributions that must be accounted for to adequately interpret the data, including beam averaging effects, multivalued temperatures due to sample phase transitions, and jumps and gaps in the observable temperature near phase transformations. The results have implications for studies employing x-ray probing of systems with large temperature gradients, particularly where these gradients are produced by the beam itself. Finally, this study shows the potential complexity of studying nonlinear sample behavior, such as phase transformations, where biasing effects of temperature gradients can become paramount, precluding clear observation of true transformation conditions.

Crystallography↗

Bifurcation-like transition of divertor conditions induced by X-point radiation in KSTAR L-mode plasmas *

Abstract Density ramps with ion grad B drift directed into lower single null KSTAR L-mode plasmas are associated with a simultaneous and abrupt reduction of the divertor particle flux on both low- and high-field-side targets when the mid-plane line averaged electron density reaches a given level. Target embedded Langmuir probe signals show a clear ‘cliff edge’ behavior similar to that observed in the divertor target electron temperature in DIII-D H-mode plasmas (Eldon et al 2017 Nucl. Fusion 57 066039; McLean et al 2015 J. Nucl. Mater. 463 533–6). The collapse of the particle flux is observed along the whole divertor target area (from private flux region to the far scrape-off layer (SOL)). The critical upstream density of this target flux cliff is invariant under fuel gas throughput modulation. The transition along the cliff occurs in tens of milliseconds. With the cliff, carbon impurities and deuterium neutrals transported through the X-point to the core produce a strong radiation spot near the X-point, seen on bolometric signals, and increase the upstream density. The experimental observations are consistent with time-dependent SOLPS-ITER simulations, which also demonstrate an abrupt transition of the target flux and upstream density with the increase in X-point radiation. The timescale of the cliff predicted by SOLPS-ITER is consistent with the experiment, although, it is influenced by gas throughput or time-dependent numerical methods. In the L-mode phase space of separatrix electron density and temperature, branches are divided based on target temperature, because the latter is strongly coupled to the radiation front and ionization front due to the monotonic characteristic of the parallel electron temperature distribution. Since the H-mode condition operates at a much higher upstream density and electron temperature in phase space, dissipation from sputtered carbon alone leads to the density limit before reaching the X-point radiation condition. This is therefore consistent with the fact that cliffs have never been observed in H-mode KSTAR experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave technique measures plasma characteristics

Plasma electron density and temperature distribution are measured by passing a high frequency millimeter wave through plasma. Variations in density and temperature are determined by measuring insertion loss as the plasma travels between the microwave transmitting and receiving antennas.

Leonard, W. F.↗

Stellar model chromospheres. VIII - 70 Ophiuchi A /K0 V/ and Epsilon Eridani /K2 V/

Model atmospheres for the late-type active-chromosphere dwarf stars 70 Oph A and Epsilon Eri are computed from high-resolution Ca II K line profiles as well as Mg II h and k line fluxes. A method is used which determines a plane-parallel homogeneous hydrostatic-equilibrium model of the upper photosphere and chromosphere which differs from theoretical models by lacking the constraint of radiative equilibrium (RE). The determinations of surface gravities, metallicities, and effective temperatures are discussed, and the computational methods, model atoms, atomic data, and observations are described. Temperature distributions for the two stars are plotted and compared with RE models for the adopted effective temperatures and gravities. The previously investigated T min/T eff vs. T eff relation is extended to Epsilon Eri and 70 Oph A, observed and computed Ca II K and Mg II h and k integrated emission fluxes are compared, and full tabulations are given for the proposed models. It is suggested that if less than half the observed Mg II flux for the two stars is lost in noise, the difference between an active-chromosphere star and a quiet-chromosphere star lies in the lower-chromospheric temperature gradient.

Kelch, W. L.↗

Two-dimensional model of a Space Station Freedom thermal energy storage canister

The Solar Dynamic Power Module being developed for Space Station Freedom uses a eutectic mixture of LiF-CaF2 phase change salt contained in toroidal canisters for thermal energy storage. Results are presented from heat transfer analyses of the phase change salt containment canister. A 2-D, axisymmetric finite difference computer program which models the canister walls, salt, void, and heat engine working fluid coolant was developed. Analyses included effects of conduction in canister walls and solid salt, conduction and free convection in liquid salt, conduction and radiation across salt vapor filled void regions and forced convection in the heat engine working fluid. Void shape, location, growth or shrinkage (due to density difference between the solid and liquid salt phases) were prescribed based on engineering judgement. The salt phase change process was modeled using the enthalpy method. Discussion of results focuses on the role of free-convection in the liquid salt on canister heat transfer performance. This role is shown to be important for interpreting the relationship between ground based canister performance (in l-g) and expected on-orbit performance (in micro-g). Attention is also focused on the influence of void heat transfer on canister wall temperature distributions. The large thermal resistance of void regions is shown to accentuate canister hot spots and temperature gradients.

Kerslake, Thomas W.↗

Unsteady analysis of hot streak migration in a turbine stage

Two- and three-dimensional Navier-Stokes analyses are used to predict unsteady viscous rotor-stator interacting flow in the presence of a combustor hot streak. Predicted results are presented for a two-dimensional three-stator/four-rotor, a two-dimensional one-stator/one-rotor, and a three-dimensional one-stator/one-rotor simulation of hot streak migration through a turbine stage. Comparison of these results with experimental data demonstrates the capability of the three-dimensional procedure to capture most of the flow physics associated with hot streak migration including the effects of combustor hot streaks on turbine rotor surface temperatures. It is noted that blade count ratio has little effect on predicted time-averaged surface pressure and temperature distributions, but a substantial effect on the unsteady flow characteristics. It is shown that high-temperature hot streak fluid accumulates on the pressure surface of the rotor blades, resulting in a high time-averaged surface temperature 'hot spots'.

Dorney, Daniel J.↗

Two-dimensional model of a Space Station Freedom thermal energy storage canister

The Solar Dynamic Power Module being developed for Space Station Freedom uses a eutectic mixture of LiF-CaF2 phase change salt contained in toroidal canisters for thermal energy storage. Results are presented from heat transfer analyses of the phase-change salt containment canister. A 2-D, axisymmetric finite-difference computer program which models the canister walls, salt, void, and heat engine working fluid coolant was developed. Analyses included effects of conduction in canister walls and solid salt, conduction and free convection in liquid salt, conduction and radiation across salt vapor filled void regions, and forced convection in the heat engine working fluid. Void shape, location, and growth or shrinkage (due to density difference between the solid and liquid salt phases) were prescribed based on engineering judgement. The salt phase change process was modeled using the enthalpy method. Discussion of results focuses on the role of free-convection in the liquid salt on canister heat transfer performance. This role is shown to be important for interpreting the relationship between groundbased canister performance (in 1-g) and expected on-orbit performance (in micro-g). Attention is also focused on the influence of void heat transfer on canister wall temperature distributions. The large thermal resistance of void regions is shown to accentuate canister hot spots and temperature gradients.

Kerslake, Thomas W.↗

Computational aspects of chemically reacting flows

An implicit, time-dependent approach is taken to solve the inviscid conservative equations in a vertex-based finite-volume formulation. The convective fluxes are estimated by a modified Riemann solver, and higher-order accuracy is obtained by means of the MUSCL. Implicit techniques are adopted to deal with the equation stiffness as a result of the clustered grid and chemical source term. The real-gas Roe matrix and the ADI and LU schemes have been tested on the sample problems: hypersonic flow over blunt configurations, such as the forebody of a double ellipse, and the near wake of a conic aerobrake. Temperature distribution and standoff distance are validated against the shock-fitting, central-differencing results. Equilibrium temperature may be recovered by artificially increasing the chemical rates at the wall. The present method satisfactorily resolves the flow structure, including the strong expansion behind the flat base. The relative merits and performance of the real-gas TVD and implicit schemes are discussed briefly.

Li, C. P.↗

SAGE II stratospheric density and temperature retrieval experiment

This paper describes a stratospheric density and temperature retrieval experiment based on the solar occultation measurement of the Stratospheric Aerosol and Gas Experiment (SAGE II). The entire retrieval analysis involves two inversion steps: the vertical structure inversion, which derives the profile of local atmospheric extinction from SAGE II limb optical depth data, and the species inversion, which inverts the concentration of air molecules, aerosols, ozone, and nitrogen dioxide from the derived atmospheric extinction at five SAGE II short wavelengths (0.385, 0.448, 0.453, 0.525, and 0.600 microns). The derived density profile is then used to infer the temperature distribution, assuming that the atmosphere is in hydrostatic equilibrium and obeys the ideal gas law. The temperature profiles retrieved from the SAGE II observations are compared with near-coincident, in both time and space, French Rayleigh lidar and NASA Wallops Flight Facility rocket datasonde soundings as well as the National Meteorological Center (NMC) data analyses. The results indicate that the mean SAGE II temperature agrees with the mean lidar measurements to within 2 C at altitudes from 30.5 to 52.5 km. The SAGE II and datasonde observations agree to within about 4 C in approximately the same altitude region.

Wang, Pi-Huan↗

Experimental Study of Combined Forced and Free Laminar Convection in a Vertical Tube

An apparatus was built to verify an analysis of combined forced and free convection in a vertical tube with uniform wall heat flux and to determine the limits of the analysis. The test section was electrically heated by resistance heating of the tube wall and was instrumented with thermocouples in such a way that detailed thermal entrance heat-transfer coefficients could be obtained for both upflow and downflow and any asymmetry in wall temperature could be detected. The experiments showed that fully developed heat-transfer results, predicted by a previous analysis, were confirmed over the range of Rayleigh numbers investigated. The concept of "locally fully developed" heat transfer was established. This concept involves the assumption that the fully developed heat-transfer analysis can be applied locally even though the Rayleigh number is varying along the tube because of physical-property variations with temperature. Thermal entrance region data were obtained for pure forced convection and for combined forced and free convection. The analysis of laminar pure forced convection in the thermal entrance region conducted by Siegel, Sparrow, and Hallman was experimentally confirmed. A transition to an eddy motion, indicated by a fluctuation in wall temperature was found in many of the upflow runs. A stability correlation was found. The fully developed Nusselt numbers in downflow were below those for pure forced convection but fell about 10 percent above the analytical curve. Quite large circumferential variations in wall temperature were observed in downflow as compaired with those encountered in upflow, and the fully developed Nussalt numbers reported are based on average wall temperatures determined by averaging the readings of two diametrically opposite wall thermocouples at each axial position. With larger heating rates in downflow the wall temperature distributions strongly suggested a cell flow near the bottom. At still larger heating rates the wall temperatures varied in a periodic way.

Hallman, Theodore M.↗

Physics Based Modeling and Rendering of Vegetation in the Thermal Infrared

We outline a procedure for rendering physically-based thermal infrared images of simple vegetation scenes. Our approach incorporates the biophysical processes that affect the temperature distribution of the elements within a scene. Computer graphics plays a key role in two respects. First, in computing the distribution of scene shaded and sunlit facets and, second, in the final image rendering once the temperatures of all the elements in the scene have been computed. We illustrate our approach for a simple corn scene where the three-dimensional geometry is constructed based on measured morphological attributes of the row crop. Statistical methods are used to construct a representation of the scene in agreement with the measured characteristics. Our results are quite good. The rendered images exhibit realistic behavior in directional properties as a function of view and sun angle. The root-mean-square error in measured versus predicted brightness temperatures for the scene was 2.1 deg C.

Smith, J. A.↗

Design Considerations for Ceramic Matrix Composite Vanes for High Pressure Turbine Applications

Issues associated with replacing conventional metallic vanes with Ceramic Matrix Composite (CMC) vanes in the first stage of the High Pressure Turbine (HPT) are explored. CMC materials have higher temperature capability than conventional HPT vanes, and less vane cooling is required. The benefits of less vane coolant are less NOx production and improved vane efficiency. Comparisons between CMC and metal vanes are made at current rotor inlet temperatures and at an vane inlet pressure of 50 atm.. CMC materials have directionally dependent strength characteristics, and vane designs must accommodate these characteristics. The benefits of reduced NOx and improved cycle efficiency obtainable from using CMC vanes. are quantified Results are given for vane shapes made of a two dimensional CMC weave. Stress components due to thermal and pressure loads are shown for all configurations. The effects on stresses of: (1) a rib connecting vane pressure and suction surfaces; (2) variation in wall thickness; and (3) trailing edge region cooling options are discussed. The approach used to obtain vane temperature distributions is discussed. Film cooling and trailing edge ejection were required to avoid excessive vane material temperature gradients. Stresses due to temperature gradients are sometimes compressive in regions where pressure loads result in high tensile stresses.

Boyle, Robert J.↗

Flux distributions and colors of accretion disks

The disk model of Shakura and Sunyaev (1973) and Novikov and Thorne (1973) is used to calculate temperature distributions and integrated spectral fluxes for disks around a typical white dwarf and a typical neutron star, under the assumption that each element of the disk locally radiates as a blackbody. In addition, the disks' integrated UBV colors are calculated using the grid colors for real model atmospheres calculated by Buser and Kurucz (1978) and the observed colors given by Allen (1973). In all the calculations the effect of radiation from one part of the disk on all the other parts is included.

Pacharintanakul, P.↗

Effects of vegetation canopy structure on remotely sensed canopy temperatures

The effects of vegetation canopy structure on thermal infrared sensor response must be understood before vegetation surface temperatures of canopies with low percent ground cover can be accurately inferred. The response of a sensor is a function of vegetation geometric structure, the vertical surface temperature distribution of the canopy components, and sensor view angle. Large deviations between the nadir sensor effective radiant temperature (ERT) and vegetation ERT for a soybean canopy were observed throughout the growing season. The nadir sensor ERT of a soybean canopy with 35 percent ground cover deviated from the vegetation ERT by as much as 11 C during the mid-day. These deviations were quantitatively explained as a function of canopy structure and soil temperature. Remote sensing techniques which determine the vegetation canopy temperature(s) from the sensor response need to be studied.

Kimes, D. S.↗

Power system applications of fiber optic sensors

This document is a progress report of work done in 1985 on the Communications and Control for Electric Power Systems Project at the Jet Propulsion Laboratory. These topics are covered: Electric Field Measurement, Fiber Optic Temperature Sensing, and Optical Power transfer. Work was done on the measurement of ac and dc electric fields. A prototype sensor for measuring alternating fields was made using a very simple electroscope approach. An electronic field mill sensor for dc fields was made using a fiber optic readout, so that the entire probe could be operated isolated from ground. There are several instances in which more precise knowledge of the temperature of electrical power apparatus would be useful. This report describes a number of methods whereby the distributed temperature profile can be obtained using a fiber optic sensor. The ability to energize electronics by means of an optical fiber has the advantage that electrical isolation is maintained at low cost. In order to accomplish this, it is necessary to convert the light energy into electrical form by means of photovoltaic cells. JPL has developed an array of PV cells in gallium arsenide specifically for this purpose. This work is described.

Johnston, A. R.↗

An evaluation of the National Meteorological Center weekly hindcast of upper-ocean temperature along the eastern Pacific equator in January 1992

The upper-ocean temperature distribution along the Pacific equator from 139 to 103 deg W was observed in January 1992 with temperature profiles recorded from a ship and inferred from an ocean general circulation model calculation involving data assimilation (i.e., hindcast). An El Nino episode was in progress. The l00-m-thick mixed layer depth, the mixed-layer temperature, and the depth-averaged temperature below the thermocline were similar in both data products. Considerable differences occurred in the representation of the 15-25 C thermocline, such as the depth-averaged temperatures above and below the 20 C isotherm, the east-west slope of the 20 C isotherm, and a 1000-km-wide depression. The longitudinal-averaged root-mean-square difference between the hindcast and observed depths of the center of the thermocline was 17 m. Most of the disparities could be attributed to a high wavenumber transient event that the model-based assimilation system was not intended to resolve.

Halpern, David↗