Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Fabrication and Characterization of Elliptically-Curved, Laterally-Graded Multilayers for Focusing X-ray Polychromator Applications

We have developed a novel X-ray multilayer working as a focusing polychromator. A multilayer mirror enables independent designs of the focal length and the spectral dispersion, and much higher throughput than the curved crystal. Our ion beam sputtering deposition apparatus has a speed programmable shuttering system for control of the lateral thickness gradient. A SiC/C and three V/C multilayers were deposited on each 150 mm long Si wafers. Period thicknesses are tuned to the designed energy of 5-12 keV, 12-19 keV, 19-26 keV and 26-33 keV, respectively. Four multilayers were clamped to form a 600 mm long 5-33 keV range elliptic mirror on a shaped Cu base plate. The focal length is 700 mm, which is large enough for setups around the sample position. The energy calibration was performed at BL-15C of the Photon Factory based on absorption edges of metal foils, which was in good agreement with the period thickness measured by a laboratory X-ray diffractometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synchronized monochromator and insertion device energy scans at SLS

Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

43 PARTICLE ACCELERATORS↗

Medipix3 array high performance read-out board for synchrotron research

The Medipix3 ASIC is one of the most advanced chip that is presently available to build photon counting area detectors. The capabilities of the chip include adjacent pixels charge summing circuitry to sort out the distortion due to charge sharing, simultaneous counting and read-out that enables frames to be acquired without dead time, the colour mode of operation that enables up to eight energy bands to be acquired. In order to fully exploit the capabilities of the Medipix3 chip in synchrotron research, a high performance electronic board capable of driving large arrays of chips is necessary. We propose a parallel read-out board of Medipix3 chip arrays with a scalable architecture that allows driving the Medipix3 chip in all of its modes of operation. The board functions include the control of the chip arrays, data formatting and data compression, the management of the communications with the data storage devices, and operation in various trigger modes. In addition to this the board will have some 'intelligence' embedded. This will add some very important features to the final detector such as pattern recognition, capability of variable frame duration as a function of the photon flux, feedback to other equipment and real time calculations of data relevant to experiments such as the autocorrelation function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ASTRO-H Mission

The joint JAXA/NASA Astro-H mission is the sixth in a series of X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). The planned launch date is 2014. Astro-H will investigate the physics of the high-energy universe by performing high-resolution, high-throughput spectroscopy with moderate spatial resolution over the 0.3-600 keV energy range. ASTRO-H is a combination of wide band X-ray spectroscopy (3-80 keV) provided by focusing hard X-ray mirrors and hard X-ray imaging detectors, and high energy-resolution soft X-ray spectroscopy (0.3-10 keV) provided by thin-foil X-ray optics and a micro-calorimeter array. The mission will also carry an X-ray CCD camera as a focal plane detector for a soft X-ray telescope and a non-focusing soft gamma-ray detector. The simultaneous broad bandpass, coupled with high spectral resolution of {Delta}E{approx}7 eV by the micro-calorimeter will enable a wide variety of important science themes to be pursued.

79 ASTRONOMY AND ASTROPHYSICS↗

Grating spectrometer system for beam emission spectroscopy diagnostics using high-energy negative-ion-based neutral beam injection on LHD

A beam emission spectroscopy (BES) system was developed for density gradient and fluctuation diagnostics in the Large Helical Device (LHD). In order to cover the large Doppler shift of the H{alpha} beam emission because of the high-energy negative-ion-based neutral beam atom (acceleration voltage V{sub acc}=90-170 kV) and the large motional Stark splitting due to the large vxB field (magnetic field B=3.0 T), a grating spectrometer was used instead of a conventional interference filter system. The reciprocal linear dispersion is about 2 nm/mm, which is sufficient to cover the motional Stark effect spectra using an optical fiber with a diameter of 1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Baryon spectroscopy: Recent results from the Crystal Barrel/TAPS experiment at ELSA

To understand the spectrum and the properties of baryon resonances, the CBELSA/TAPS experiment at ELSA investigates the photoproduction of single- and multi-meson final states off the nucleon. In the latter final states baryon cascades via Dp and Dh and also via higher mass baryon resonances are clearly observed. A partial wave analysis based on single and double meson photoproduction data as well as data from other reactions allows a first determination of resonance properties including partial decay widths of various N* and {Delta}* states. Those include also the decays into the different p{pi}{sup 0{pi}0} and p{pi}{sup 0{eta}} decay channels resulting partly in unexpected results. Recently not only single but also double polarisation experiments have been performed, which are absolutelly necessary to resolve ambiguities in the partial wave analyses (PWA) used to extract the resonances from the data; without the measurement of polarisation observables a model-independent PWA will not be possible. Polarisation observables have been investigated using linearly, circularly polarized or unpolarized photons impinging on an longitudinally polarized or unpolarized target. Given the angular coverage of the Crystal-Barrel/TAPS experiment this data cover almost the full angular range and phase space. This data will provide key information for the partial wave analyses and brings us one step closer towards the needed complete experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In-medium modifications of the {omega} meson

We have investigated the in-medium modifications of {omega} mesons in photoproduction experiments using the Crystal Barrel(CB)/TAPS detector system at the ELSA accelerator facility in Bonn. {omega}-mesons were reconstructed using the {omega}{yields}{pi}{sup 0{gamma}} channel. In a first analysis of the data set on a Nb target, published by D. Trnka et al.. [1], evidence for an in-medium mass shift of the {omega}-meson was deduced from the observed {omega} lineshape. The signal shape is, however, sensitive to the background subtraction and fitting procedure as pointed out in the literature [2, 3]. For this reason a re-analysis of the same data set was initiated with the goal to reduce the background and to deduce the shape and the absolute magnitude of the background directly from the data. Here we present recent results from this re-analysis. The omega signal resulting after background subtraction has been compared to different scenarios of Gi-BUU transport model calculations for the full incident photon energy range (900-2200 MeV) and near the production threshold (900-1400 MeV).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra-High Gradient S-band Linac for Laboratory and Industrial Applications

A strong demand for high gradient structures arises from the limited real estate available for linear accelerators. RadiaBeam Technologies is developing a Doubled Energy Compact Accelerator (DECA) structure: an S-band standing wave electron linac designed to operate at accelerating gradients of up to 50 MV/m. In this paper, we present the radio-frequency design of the DECA S-band accelerating structure, operating at 2.856 GHz in the {pi}-mode. The structure design is heavily influenced by NLC collaboration experience with ultra high gradient X-band structures; S-band, however, is chosen to take advantage of commonly available high power S-band klystrons.

43 PARTICLE ACCELERATORS↗

Carbon-doped single-crystalline SiGe/Si thermistor with high temperature coefficient of resistance and low noise level

SiGe (C)/Si(C) multiquantum wells have been studied as a thermistor material for future bolometers. A thermistor material for uncooled Si-based thermal detectors with thermal coefficient of resistance of 4.5%/K for 100x100 {mu}m{sup 2} pixel sizes and low noise constant (K{sub 1/f}) value of 4.4x10{sup -15} is presented. The outstanding performance of the devices is due to Ni-silicide contacts, smooth interfaces, and high quality multiquantum wells containing high Ge content.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vector meson production and DVCS at HERA

An overview of the latest results obtained by the H1 and ZEUS experiments at HERA on diffractive production of Vector Mesons and Deeply Virtual Compton Scattering (DVCS) is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nanofabrication of Optical Elements for SXR and EUV Applications: Ion Beam Lithography as a New Approach

Diffractive optical elements are important components for applications in soft x-ray and extreme ultraviolet radiation. At present, the standard fabrication method for such optics is based on electron beam lithography followed by nanostructuring. This requires a series of complex processes including exposure, reactive ion-etching, and electro-plating. We report on experiments showing the single-step fabrication of such elements using ion beam lithography. Both transmission and reflection gratings were fabricated and successfully implemented as spectrometers at laboratory soft x-ray sources. Additionally, first steps toward zone plate fabrication are described.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Laser Doppler visualisation of the fields of three-dimensional velocity vectors with the help of a minimal number of CCD cameras

We discuss the possibility of laser Doppler visualisation and measurement of the field of three-dimensional velocity vectors by suppressing the multiparticle scattering influence on the measurement results, when using one CCD camera. The coordinate measuring basis is formed due to switching of the directions and the frequency of spatially combined laser sheets, the frequency being synchronised with the CCD-camera operation. The field of the velocity vectors without the contribution from the multiparticle scattering is produced from the linear combinations of normalised laser sheet images detected with a CCD camera in a frequency-demodulated scattered light. The method can find applications not only in laser diagnostics of gas and condensed media but also in the Doppler spectroscopy of light fields scattered by multiparticle dynamic structures. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TIME-DEPENDENT MODELS FOR THE AFTERGLOWS OF MASSIVE BLACK HOLE MERGERS

The Laser Interferometer Space Antenna (LISA) will detect gravitational wave signals from coalescing pairs of massive black holes (MBHs) in the total mass range (10{sup 5}-10{sup 7})/(1 + z) M{sub sun} out to cosmological distances. Identifying and monitoring the electromagnetic (EM) counterparts of these events would enable cosmological studies and offer new probes of gas physics around well-characterized MBHs. Milosavljevic and Phinney proposed that a circumbinary disk around a binary of mass {approx}10{sup 6} M{sub sun} will emit an accretion-powered X-ray afterglow approximately one decade after the gravitational wave event. We revisit this scenario by using Green's function solutions to calculate the temporal viscous evolution and the corresponding EM signature of the circumbinary disk. Our calculations suggest that an EM counterpart may become observable as a rapidly brightening source soon after the merger, i.e., several years earlier than previously thought. The afterglow can reach super-Eddington luminosities without violating the local Eddington flux limit. It is emitted in the soft X-ray by the innermost circumbinary disk, but it may be partially reprocessed at optical and infrared frequencies. We also find that the spreading disk becomes increasingly geometrically thick close to the central object as it evolves, indicating that the innermost flow could become advective and radiatively inefficient, and generate a powerful outflow. We conclude that the mergers of MBHs detected by LISA offer unique opportunities for monitoring, on humanly tractable timescales, the viscous evolution of accretion flows and the emergence of outflows around MBHs with precisely known masses, spins, and orientations.

79 ASTRONOMY AND ASTROPHYSICS↗

EXQUISITE NOVA LIGHT CURVES FROM THE SOLAR MASS EJECTION IMAGER (SMEI)

We present light curves of three classical novae (CNe; KT Eridani, V598 Puppis, V1280 Scorpii) and one recurrent nova (RS Ophiuchi) derived from data obtained by the Solar Mass Ejection Imager (SMEI) on board the Coriolis satellite. SMEI provides near complete skymap coverage with precision visible-light photometry at 102 minute cadence. The light curves derived from these skymaps offer unprecedented temporal resolution around, and especially before, maximum light, a phase of the eruption normally not covered by ground-based observations. They allow us to explore fundamental parameters of individual objects including the epoch of the initial explosion, the reality and duration of any pre-maximum halt (found in all three fast novae in our sample), the presence of secondary maxima, speed of decline of the initial light curve, plus precise timing of the onset of dust formation (in V1280 Sco) leading to estimation of the bolometric luminosity, white dwarf mass, and object distance. For KT Eri, Liverpool Telescope SkyCamT data confirm important features of the SMEI light curve and overall our results add weight to the proposed similarities of this object to recurrent rather than to CNe. In RS Oph, comparison with hard X-ray data from the 2006 outburst implies that the onset of the outburst coincides with extensive high-velocity mass loss. It is also noted that two of the four novae we have detected (V598 Pup and KT Eri) were only discovered by ground-based observers weeks or months after maximum light, yet these novae reached peak magnitudes of 3.46 and 5.42, respectively. This emphasizes the fact that many bright novae per year are still overlooked, particularly those of the very fast speed class. Coupled with its ability to observe novae in detail even when relatively close to the Sun in the sky, we estimate that as many as five novae per year may be detectable by SMEI.

79 ASTRONOMY AND ASTROPHYSICS↗

PLASMA MOTIONS AND HEATING BY MAGNETIC RECONNECTION IN A 2007 MAY 19 FLARE

Based on scanning spectroscopic observations with the Hinode EUV imaging spectrometer, we have found a loop-top hot source, a fast jet nearby, and an inflow structure flowing to the hot source that appeared in the impulsive phase of a long-duration flare at the disk center on 2007 May 19. The hot source observed in Fe XXIII and Fe XXIV emission lines has the electron temperature of 12 MK and density of 1 Multiplication-Sign 10{sup 10} cm{sup -3}. It shows excess line broadening, which exceeds the thermal Doppler width by {approx}100 km s{sup -1}, with a weak redshift of {approx}30 km s{sup -1}. We have also observed a blueshifted faint jet whose Doppler velocity exceeds 200 km s{sup -1} with an electron temperature of 9 MK. Coronal plasmas with electron temperature of 1.2 MK and density of 2.5 Multiplication-Sign 10{sup 9} cm{sup -3} that flow into the loop-top region with a Doppler velocity of 20 km s{sup -1} have been identified in the Fe XII observation. They disappeared near the hot source, possibly by being heated to the hotter faint jet temperature. From the geometrical relationships of these phenomena, we conclude that they provide evidence for magnetic reconnection that occurs near the loop-top region. The estimated reconnection rate is 0.05-0.1, which supports the Petschek-type magnetic reconnection. Further supporting evidence for the presence of the slow-mode and fast-mode MHD shocks in the reconnection geometry is given based on the observed quantities.

79 ASTRONOMY AND ASTROPHYSICS↗

THE INFRARED SPECTRUM OF URANIUM HOLLOW CATHODE LAMPS FROM 850 nm to 4000 nm: WAVENUMBERS AND LINE IDENTIFICATIONS FROM FOURIER TRANSFORM SPECTRA

We provide new measurements of wavenumbers and line identifications of 10, 100 U I and U II near-infrared (NIR) emission lines between 2500 cm{sup -1} and 12, 000 cm{sup -1} (4000-850 nm) using archival Fourier transform spectrometer spectra from the National Solar Observatory. This line list includes isolated uranium lines in the Y, J, H, K, and L bands (0.9-1.1 {mu}m, 1.2-1.35 {mu}m, 1.5-1.65 {mu}m, 2.0-2.4 {mu}m, and 3.0-4.0 {mu}m, respectively), and provides six times as many calibration lines as thorium in the NIR spectral range. The line lists we provide enable inexpensive, commercially available uranium hollow cathode lamps to be used for high-precision wavelength calibration of existing and future high-resolution NIR spectrographs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calomplification — the power of generative calorimeter models

Motivated by the high computational costs of classical simulations, machine-learned generative models can be extremely useful in particle physics and elsewhere. They become especially attractive when surrogate models can efficiently learn the underlying distribution, such that a generated sample outperforms a training sample of limited size. This kind of GANplification has been observed for simple Gaussian models. We show the same effect for a physics simulation, specifically photon showers in an electromagnetic calorimeter.

47 OTHER INSTRUMENTATION↗