Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A two dimensional interface element for coupling of independently modeled three dimensional finite element meshes and extensions to dynamic and non-linear regimes

The work reported here pertains only to the first year of research for a three year proposal period. As a prelude to this two dimensional interface element, the one dimensional element was tested and errors were discovered in the code for built-up structures and curved interfaces. These errors were corrected and the benchmark Boeing composite crown panel was analyzed successfully. A study of various splines led to the conclusion that cubic B-splines best suit this interface element application. A least squares approach combined with cubic B-splines was constructed to make a smooth function from the noisy data obtained with random error in the coordinate data points of the Boeing crown panel analysis. Preliminary investigations for the formulation of discontinuous 2-D shell and 3-D solid elements were conducted.

Aminpour, Mohammad↗

Investigation of several aspects of LANDSAT-4 data quality

No insurmountable problems in change detection analysis were found when portions of scenes collected simultaneously by LANDSAT 4 MSS and either LANDSAT 2 or 3. The cause of the periodic noise in LANDSAT 4 MSS images which had a RMS value of approximately 2DN should be corrected in the LANDSAT D instrument before its launch. Analysis of the P-tape of the Arkansas scene shows bands within the same focal plane very well registered except for the thermal band which was misregistered by approximately three 28.5 meter pixels in both directions. It is possible to derive tight confidence bounds for the registration errors. Preliminary analyses of the Sacramento and Arkansas scenes reveals a very high degree of consistency with earlier results for bands 3 vs 1, 3 vs 4, and 3 vs 5. Results are presented in table form. It is suggested that attention be given to the standard deviations of registrations errors to judge whether or not they will be within specification once any known mean registration errors are corrected. Techniques used for MTF analysis of a Washington scene produced noisy results.

Wrigley, R. C.↗

HRA Aerospace Challenges

Compared to equipment designed to perform the same function over and over, humans are just not as reliable. Computers and machines perform the same action in the same way repeatedly getting the same result, unless equipment fails or a human interferes. Humans who are supposed to perform the same actions repeatedly often perform them incorrectly due to a variety of issues including: stress, fatigue, illness, lack of training, distraction, acting at the wrong time, not acting when they should, not following procedures, misinterpreting information or inattention to detail. Why not use robots and automatic controls exclusively if human error is so common? In an emergency or off normal situation that the computer, robotic element, or automatic control system is not designed to respond to, the result is failure unless a human can intervene. The human in the loop may be more likely to cause an error, but is also more likely to catch the error and correct it. When it comes to unexpected situations, or performing multiple tasks outside the defined mission parameters, humans are the only viable alternative. Human Reliability Assessments (HRA) identifies ways to improve human performance and reliability and can lead to improvements in systems designed to interact with humans. Understanding the context of the situation that can lead to human errors, which include taking the wrong action, no action or making bad decisions provides additional information to mitigate risks. With improved human reliability comes reduced risk for the overall operation or project.

DeMott, Diana↗

Technology Advancement of the Visible Nulling Coronagraph

The critical high contrast imaging technology for the Extrasolar Planetary Imaging Coronagraph (EPIC) mission concept is the visible nulling coronagraph (VNC). EPIC would be capable of imaging jovian planets, dust/debris disks, and potentially super-Earths and contribute to answering how bright the debris disks are for candidate stars. The contrast requirement for EPIC is 10(exp 9) contrast at 125 milli-arseconds inner working angle. To advance the VNC technology NASA/Goddard Space Flight Center, in collaboration with Lockheed-Martin, previously developed a vacuum VNC testbed, and achieved narrowband and broadband suppression of the core of the Airy disk. Recently our group was awarded a NASA Technology Development for Exoplanet Missions to achieve two milestones: (i) 10(exp 8) contrast in narrowband light, and, (ii) 10(ecp 9) contrast in broader band light; one milestone per year, and both at 2 Lambda/D inner working angle. These will be achieved with our 2nd generation testbed known as the visible nulling testbed (VNT). It contains a MEMS based hex-packed segmented deformable mirror known as the multiple mirror array (MMA) and coherent fiber bundle, i.e. a spatial filter array (SFA). The MMA is in one interferometric arm and works to set the wavefront differences between the arms to zero. Each of the MMA segments is optically mapped to a single mode fiber of the SFA, and the SFA passively cleans the sub-aperture wavefront error leaving only piston, tip and tilt error to be controlled. The piston degree of freedom on each segment is used to correct the wavefront errors, while the tip/tilt is used to simultaneously correct the amplitude errors. Thus the VNT controls both amplitude and wavefront errors with a single MMA in closed-loop in a vacuum tank at approx.20 Hz. Herein we will discuss our ongoing progress with the VNT.

Lyon, Richard G.↗

Analysis of the new polarimeter for the Marshall Space Flight Center vector magnetograph

The magnetograph was upgraded in both electronic control of the magnetograph hardware and in the polarization optics. The problems associated with the orignal polarimeter were: (1) field of view errors associated with the natural birefringence of the KD*P crystals; (2.) KD*P electrode failure due to the halfwave dc voltage required in one of the operational sequences; and (3) breakdown of the retardation properties of some KD*Ps when exposed to a zero to halfwave modulation (DC) scheme. The new polarimeter gives up the flexibility provided by two variable waveplates to adjust the retardances of the optics for a particular polarization measurement, but solves the problems associated with the original polarimeter. With the addition of the quartz quarterwave plates, a new optical alignment was developed to allow the remaining KD*P to correct for errors in the waveplates. The new optical alignment of the polarimeter is prescribed. The various sources of error, and how those errors are minimized so that the magnetograph can look at the transverse field in real time are discussed.

West, E. A.↗

The Algorithm Theoretical Basis Document for Tidal Corrections

This Algorithm Theoretical Basis Document deals with the tidal corrections that need to be applied to range measurements made by the Geoscience Laser Altimeter System (GLAS). These corrections result from the action of ocean tides and Earth tides which lead to deviations from an equilibrium surface. Since the effect of tides is dependent of the time of measurement, it is necessary to remove the instantaneous tide components when processing altimeter data, so that all measurements are made to the equilibrium surface. The three main tide components to consider are the ocean tide, the solid-earth tide and the ocean loading tide. There are also long period ocean tides and the pole tide. The approximate magnitudes of these components are illustrated in Table 1, together with estimates of their uncertainties (i.e. the residual error after correction). All of these components are important for GLAS measurements over the ice sheets since centimeter-level accuracy for surface elevation change detection is required. The effect of each tidal component is to be removed by approximating their magnitude using tidal prediction models. Conversely, assimilation of GLAS measurements into tidal models will help to improve them, especially at high latitudes.

Fricker, Helen A.↗

Determination of Small Animal Long Bone Properties Using Densitometry

Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased precision and repeatability. Standard deviations for the femur are consistent with those of the phantom. We conclude that in conjunction with digital image enhancement, densitometry scans are suitable for non-destructive determination of areal properties of small animal bones of comparable size to our phantom, allowing prediction of Imax and Imin within 2.5% and Theta within a fraction of a degree. This method represents a considerable extension of current methods of analyzing bone tissue distribution in small animal bones.

Breit, Gregory A.↗

Progress of Coating Stress Compensation of Silicon Mirrors for Lynx X-ray Telescope Mission Concept Using Thermal Oxide Patterning Method

A thermal oxide patterning method has proven to be effective for correcting coating-stress-induced distortion on flat silicon wafers. We report progress on developing this method for correcting curved silicon mirrors distorted by front-side iridium coatings. Owing to the difference in geometry, a finite element model has been established to calculate the appropriate duty cycle maps in thermal oxide hexagon patterns used for compensation. In addition, a photolithographic process, along with three-dimensional printed equipment, has been developed for creating patterns precisely on the back side of curved mirrors. The developed method has been used to recover the original surface shape of two silicon mirrors which are 100-mm long, 0.5-mm thick, having 312-mm radius of curvature, and 30 deg in azimuthal span (Wolter-I geometry). These mirrors’ front sides are sputter-coated by 20-nm iridium layers with ∼-70 N∕m integrated stress. Measurement results show that the developed method can mitigate coating-induced distortion by a factor of ∼5 in RMS height and ∼4 in RMS slope error, corresponding to ∼0.5 arc sec RMS slope error. Residual errors after correction are dominated by midfrequency ripples created during the annealing process, which will be resolved in the future. The presented method is precise and inexpensive and a potential candidate for resolving the coating stress issue for Lynx optics in the future.

x-ray↗