Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

IGCC performance comparison for variations in gasifier type and gas turbine firing temperature

Performance estimates were made for a series of integrated coal gasification combined cycle (IGCC) power systems using three generic types of coal gasification subsystems. The objectives of this study were (1) to provide a self consistent comparison of IGCC systems using different types of gasifiers and different oxidants and (2) to use this framework of cases to evaluate the effect of a gas turbine firing temperature and cooling approach an overall system efficiency. The basic IGCC systems considered included both air and oxygen blown versions of a fluidized bed gasifier, represented by the Westinghouse design, and an entrained bed gasifier, represented by the Texaco design. Also considered were systems using an oxygen blown, fixed bed gasifier, represented by the British Gas Corporation (BGC) slagging gasifier. All of these gasifiers were integrated with a combined cycle using a gas turbine firing temperature of 1700 K (2600 F) and a compressor pressure ratio of 16:1. Steam turbine throttle conditions were chosen to be 16.6 MPa/811 K (2400 psia/1000 F) with a single reheat to 810 K (1000 F). Some of these cases were modified to allow the evaluation of the effect of gas turbine firing temperature. Turbine firing temperatures from state of the art 1365 K (2000 F) to an advanced technology 1920 K (3000 F) were analyzed. A turbine cooling technology that maintains metal temperatures below acceptable limits was assumed for each level of firing temperature. System performance comparisons were made using three advanced turbine cooling technologies for the 1920 K (3000 F) firing temperature. The results indicate that the IGCC using the BGC gasifier had the highest net system efficiency (42.1 percent) of the five gasification cases considered.

Stochl, R. J.↗

Toward an AI-Powered Software Pipeline for Real-Time Tracking and Analysis of Wildfire and Smoke

Real-time tracking of wildfires and smoke is crucial for effective response, minimizing damage, protecting lives, and efficiently managing resources during fire emergencies. We develop a web-based AI-powered pipeline that detects wildfires in aerial video and estimates deployment-relevant behavior metrics, including cumulative burned area, burned-area growth rate, fire spread direction, and smoke dispersion. The system combines a YOLO-based detector with YCbCr-based fire segmentation, HSV-based smoke segmentation, Farneback optical flow, and centroid-based spatiotemporal tracking. Using ground sampling distance (GSD), pixel-level fire masks are converted to physical burned-area measurements by correlating fire pixel counts with camera altitude and tilt angle. We benchmark YOLO variants and non-YOLO baselines (GoogLeNet, CNN, DBN, Autoencoder, U-Net, and AlexNet) on the IEEE FLAME dataset and a newly created aerial frame dataset, Wildfire-DB. Cross-dataset evaluation uses a strict threshold-transfer protocol: decision thresholds are selected on FLAME validation and transferred unchanged to Wildfire-DB to quantify generalization under domain shift. YOLOv6 achieves the strongest cross-dataset frame-level fire detection on Wildfire-DB (ROC-AUC 0.8200, PR-AUC 0.8044, and transferred-threshold F1 0.7596). For tracking-oriented deployment requiring oriented localization, YOLO11-OBB provides the most reliable cross-dataset behavior among OBB-capable models while remaining computationally feasible. To analyze the feasibility of UAV deployment, we further measure inference efficiency using synchronized GPU and CPU power logs on a fixed workload of 1569 frames. YOLO-family models process the video in 5.73–12.47 seconds with net energy of 1247.28–1775.39 J, substantially lower latency and energy than heavier classification and reconstruction baselines. Overall, model optimality depends on operational objectives: YOLOv6 is best for cross-dataset detection robustness, whereas YOL...

Color segmentation↗

Safety-Class Uninterruptable Power Supply General Contractor for the TA-55 TRP II Project: REQUEST FOR QUALIFICATION No. ADPM-002 - PREQUALIFICATION CRITERIA

LANS is seeking to establish qualified suppliers for the procurement and construction of a Safety-Class Uninterruptable Power Supply (UPS) facility in accordance with ASME NQA-1 2008 and 2009 addenda. This scope includes Work required to construct a new UPS facility at Technical Area (TA)-55 including procurement, construction, installation, and post installation testing of all structures, systems, and equipment (e.g., foundations, concrete, structural steel, building components, HVAC, fire protection, site utilities) excluding the UPS system itself. Design of the facility and associated infrastructure are provided by LANL. Final design of the UPS system will be provided by the UPS Integrator under separate contract. Procurement of all safety-related components (specified by LANL) must be in accordance with NQA-1 and must be purchased from qualified suppliers that have an NQA-1 program or through Commercial Grade Dedication (CGD) in accordance with NQA-1a-2009, Subpart 2.14. The SUBCONTRACTOR shall plan, schedule, coordinate, test, inspect and assure effective performance of all aspects of the Work as described herein.

42 ENGINEERING↗

SpaceX Dragon Air Circulation System

The Dragon capsule is a reusable vehicle being developed by Space Exploration Technologies (SpaceX) that will provide commercial cargo transportation to the International Space Station (ISS). Dragon is designed to be a habitable module while it is berthed to ISS. As such, the Dragon Environmental Control System (ECS) consists of pressure control and pressure equalization, air sampling, fire detection, illumination, and an air circulation system. The air circulation system prevents pockets of stagnant air in Dragon that can be hazardous to the ISS crew. In addition, through the inter-module duct, the air circulation system provides fresh air from ISS into Dragon. To utilize the maximum volume of Dragon for cargo packaging, the Dragon ECS air circulation system is designed around cargo rack optimization. At the same time, the air circulation system is designed to meet the National Aeronautics Space Administration (NASA) inter-module and intra-module ventilation requirements and acoustic requirements. A flight like configuration of the Dragon capsule including the air circulation system was recently assembled for testing to assess the design for inter-module and intra-module ventilation and acoustics. The testing included the Dragon capsule, and flight configuration in the pressure section with cargo racks, lockers, all of the air circulation components, and acoustic treatment. The air circulation test was also used to verify the Computational Fluid Dynamics (CFD) model of the Dragon capsule. The CFD model included the same Dragon internal geometry that was assembled for the test. This paper will describe the Dragon air circulation system design which has been verified by testing the system and with CFD analysis.

Hernandez, Brenda↗

CONUS and Global Carbon Consumption Database for Wildland Fire

Fire plays a significant role on both national and global scales, profoundly impacting landscapes shaped by human activity as well as wildlands. Even though fire can be devastating, wildland fire is a natural and integral force on our landscapes. Fires can also serve to reduce fuels to mitigate wildfire risk and maintain healthy ecosystem functions. However, the smoke produced by fires, regardless of their size or purpose, can pose adverse effects on human health when inhaled downwind. Understanding the influence of smoke on air quality and human well-being necessitates the quantification of emissions that fires release into the atmosphere. In response to this need, we have developed a carbon consumption database for the Continental United States (CONUS) and are developing a global carbon consumption database, both of which are directly link to distinct fuels within various fire danger categories. Fuel Characteristic Classification System (FCCS) fuels are used to parameterize biomass, and consumption is broken down into five Fire Danger categories (Low, Moderate, High, Very High, Extreme), for both ‘new’ and ‘residual’ burning scenarios. Residual burned area is defined as burning in areas that have recently burned. We implemented the FCCS 30-meter CONUS fuelbed dataset during the 2019 Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) campaign to estimate daily carbon emissions. Our emissions estimates were rigorously compared against in-situ measurements of CO2, CO, and black carbon aerosols, revealing a robust agreement between the two datasets. The 300-meter global database builds upon the foundations of the Pettinari, M. Lucrecia (2015) Global Fuelbed database, a global fuel map with standardized FCCS biomass parameters. These products can serve as valuable tools when used in conjunction with burned area data to rapidly and accurately estimate carbon consumed and released into the atmosphere.

FCCS↗

Thermodynamic performance and cost optimization of a novel hybrid thermal-compressed air energy storage system design

Compressed Air Energy Storage (CAES) can potentially allow renewable energy sources to meet electricity demands as reliably as coal-fired power plants. However, conventional CAES systems rely on the combustion of natural gas, require large storage volumes, and operate at high pressures, which possess inherent problems such as high costs, strict geological locations, and the production of greenhouse gas emissions. A novel and patented hybrid thermal-compressed air energy storage (HT-CAES) design is presented which allows a portion of the available energy, from the grid or renewable sources, to operate a compressor and the remainder to be converted and stored in the form of heat, through joule heating in a sensible thermal storage medium. The HT-CAES design incudes a turbocharger unit that provides supplementary mass flow rate alongside the air storage. The hybrid design and the addition of a turbocharger have the beneficial effect of mitigating the shortcomings of conventional CAES systems and its derivatives by eliminating combustion emissions and reducing storage volumes, operating pressures, and costs. Storage efficiency and cost are the two key factors, which upon integration with renewable energies would allow the sources to operate as independent forms of sustainable energy. The potential of the HT-CAES design is illustrated through a thermodynamic optimization study, which outlines key variables that have a major impact on the performance and economics of the storage system. The optimization analysis quantifies the required distribution of energy between thermal and compressed air energy storage, for maximum efficiency, and for minimum cost. This study provides a roundtrip energy and exergy efficiency map of the storage system and illustrates a trade off that exists between its capital cost and performance.

25 ENERGY STORAGE↗

Time Dependent Analysis of Laser Heating of Metal Parts in Contact with HE

We consider the time dependent heat transfer of laser energy impinging on metal parts that are in contact with high explosives (HE). The predecessor to this calculation was TN-J4-17-2109, “Heat Transfer Analysis from Laser Energy on Metal Parts in Contact with HE”, which considered the time independent heat transfer and compared to experimental results. The intent here is to extend those results to the time dependent case. The steady-state results were developed because they were the “worst case” from a safety perspective: the steady state represents the highest possible temperature excursion. However, we found that the temperatures achieved were well above the safety limits established by the DOE High Explosives Safety Manual. Moreover, they were well above the safety limit published by the LANL / Weapons Facilities Operations (WFO) in WFO-OS-ES-48, which establishes an upper temperature limit of 70°C for metal in contact with High Explosive (HE). The J-4 response to the original results was to design, build, and deploy an interlock system for DARHT that would ensure no laser energy on the firing point when both personnel and HE were present. This system was tested and proved effective, refer TP-DARHT-1150, (12/19/2016). It was reviewed and approved by the LANL Explosives Instrumentation Review Committee, refer PRES-J4-16-2140, “DARHT Laser Diagnostics Interlock System: Presentation to the EIRC”, (2016). Although the interlock system prevented personnel from being on the firing point under conditions where the diagnostic lasers would heat metal above the WFO limit, the WFO limit was still exceeded during the Multiplexed Photonic Doppler Velocimetry (MPDV) tuning process. The only practical solution is to limit the amount of time that the MPDV lasers are engaged at full power. The diagnostics interlock system was implemented with laser shutters that can fully interrupt the beams, and these shutters can be used to limit the amount of time that the lasers will impinge on the hydrotest assembly. It is the purpose of this paper to provide quantitative guidance on what length of time can be permitted during this tuning process. Therefore, we will solve the time-dependent heat transfer equation to determine the temperature increase as a function of time. This function can be inverted to determine the maximum allowable time for energizing the lasers based on the maximum allowable temperature at the metal to HE interface.

42 ENGINEERING↗

Shared Knowledge for Decision-making on Environment and Health Issues in the Arctic

This paper will describe a remote sensing and GIs-based system to bring indigenous traditional knowledge together with contemporary scientific knowledge to address impacts resulting from changes in climate, environment, weather and pollution in the Arctic. As scientists and policy-makers from both indigenous and non-indigenous communities continue to build closer partnerships to address common sustainability issues such as the health impacts of climate change and anthropogenic activities, it becomes increasingly important to create shared information management systems which integrate all relevant factors for optimal information sharing and decision-making. This system is being designed to bring together remotely sensed, indigenous and other data and observations for analysis, measuring, and monitoring parameters of interest (e.g., snow cover, rainfall, temperature, ice conditions, vegetation, infrastructure, fires). A description of the system and its components as well as a preliminary application of the system in the Arctic will be presented.

Maynard, Nancy G.↗

Wet countdown demonstration and flight readiness firing

The prelaunch tests for the Space Transportation System 1 flight are briefly described. Testing is divided into two major sections: the wet countdown demonstration test/flight readiness firing, which includes a 20 second test firing of the orbiter's three main engines, and a mission verification test, which is centered on flight and landing operations. The functions of the countdown sequence are listed and end of mission and mission abort exercises are described.

Source record↗

Assessment of the impact of dipped guideways on urban rail transit systems: Ventilation and safety requirements

The ventilation and fire safety requirements for subway tunnels with dipped profiles between stations as compared to subway tunnels with level profiles were evaluated. This evaluation is based upon computer simulations of a train fire emergency condition. Each of the tunnel configurations evaluated was developed from characteristics that are representative of modern transit systems. The results of the study indicate that: (1) The level tunnel system required about 10% more station cooling than dipped tunnel systems in order to meet design requirements; and (2) The emergency ventilation requirements are greater with dipped tunnel systems than with level tunnel systems.

Source record↗

Integrating Land Cover Modeling and Adaptive Management to Conserve Endangered Species and Reduce Catastrophic Fire Risk

Land cover modeling is used to inform land management, but most often via a two-step process where science informs how management alternatives can influence resources and then decision makers can use this to make decisions. A more efficient process is to directly integrate science and decision making, where science allows us to learn to better accomplish management objectives and is developed to address specific decisions. Co-development of management and science is especially productive when decisions are complicated by multiple objectives and impeded by uncertainty. Multiple objectives can be met by specification of tradeoffs, and relevant uncertainty can be addressed through targeted science (i.e., models and monitoring). We describe how to integrate habitat and fuels monitoring with decision making focused on dual objectives of managing for endangered species and minimizing catastrophic fire risk. Under certain conditions, both objectives might be achieved by a similar management policy, but habitat trajectories suggest tradeoffs. Knowledge about system responses to actions can be informed by applying competing management actions to different land units in the same system state and by ideas about fire behavior. Monitoring and management integration is important to optimize state-specific management decisions and increase knowledge about system responses. We believe this approach has broad utility for and cover modeling programs intended to inform decision making.

adaptive management↗

A study of marine stratocumulus using lidar and other FIRE aircraft observations

The National Center for Atmospheric Research (NCAR) airborne infrared lidar system (NAILS) used in the 1987 First ISCCP Regional Experiment (FIRE) off the coast of California is a 10.6 microns wavelength carbon dioxide lidar system constructed by Ron Schwiesow and co-workers at NCAR. The lidar is particularly well suited for detailed observations of cloud shapes; i.e., height of cloud top (when flying above cloud and looking down) and cloud base (when flying below cloud and looking up) along the flight path. A brief summary of the lidar design characteristics is given. The lidar height resolution of plus or minus 3 m allows for the distance between the aircraft and cloud edge to be determined with this accuracy; however, the duration of the emitted pulse is approximately 3 microseconds, which corresponds to a 500 m pulse length. Therefore, variations in backscatter intensities within the clouds can normally not be resolved. Hence the main parameter obtainable from the lidar is distance to cloud; in some cases the cloud depth can also be determined. During FIRE the lidar was operational on 7 of the 10 Electra flights, and data were taken when the distance between cloud and aircraft (minimum range) was at least 500 m. The lidar was usually operated at 8 Hz, which at a flight speed of 100 m s(-1) translates into a horizontal resolution of about 12 m. The backscatter as function of time (equivalent to distance) for each laser pulse is stored in digital form on magnetic tape. Currently, three independent variables are available to the investigators on the FIRE Electra data tapes: lidar range to cloud, strength of return (relative power), and pulse width of return, which is related to penetration depth.

Jensen, Jorgen B.↗

Carbon footprints of heating oil and LPG heating systems

For European homes without access to the natural gas grid, the main fuels-of-choice for heating are heating oil and LPG. How do the carbon footprints of these compare? Existing literature does not clearly answer this, so the current study was undertaken to fill this gap. Footprints were estimated in seven countries that are representative of the EU and constitute two-thirds of the EU-27 population: Belgium, France, Germany, Ireland, Italy, Poland and the UK. Novelties of the assessment were: systems were defined using the EcoBoiler model; well-to-tank data were updated according to most-recent research; and combustion emission factors were used that were derived from a survey conducted for this study. The key finding is that new residential heating systems fuelled by LPG are 20% lower carbon and 15% lower overall-environmental-impact than those fuelled by heating oil. An unexpected finding was that an LPG system's environmental impact is about the same as that of a bio heating oil system fuelled by 100% rapeseed methyl ester, Europe's predominant biofuel. Moreover, a 20/80 blend (by energy content) with conventional heating oil, a bio-heating-oil system generates a footprint about 15% higher than an LPG system's. The final finding is that fuel switching can pay off in carbon terms. If a new LPG heating system replaces an ageing oil-fired one for the final five years of its service life, the carbon footprint of the system's final five years is reduced by more than 50%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electric Vehicle Fire Primer for Fleet Managers

The U.S. Department of Energy's Vehicle Technologies Office provides project assistance through Clean Cities, technical expertise, and funding to help stake-holders implement alternative fuels and electric vehicles (EVs). Fleet managers considering EVs can learn about the potential for EV fires and measures to help reduce fire risk.

ADVANCED PROPULSION SYSTEMS↗

Absorption/Desorption based high efficiency Supercritical Carbon Dioxide Power Cycles - Final Scientific/Technical Report

The team of Southwest Research Institute® (SwRI®) and Thar Energy LLC (Thar) are advancing the state of the art in fossil-fired closed Brayton supercritical carbon dioxide (sCO 2 ) power cycles. This current effort is focused on evaluating the integration of a fossil-based thermal system with closed Brayton sCO 2 power blocks to understand the impact of thermal integration on plant performance and identification of current technology gaps. This effort is extending the current understanding of how fossil-based thermal systems may best be integrated with recuperated closed Brayton cycles based on the overall impact on the integrated plant efficiency, cost, and operating characteristics. System Engineering Design and Thermodynamic Analysis is being utilized to (1) identify technical challenges impacting the integration of fossil-based thermal sources with highly recuperated closed Brayton sCO 2 power cycles, (2) evaluate the impact of boiler design and sCO 2 cycle configuration on integrated plant performance, cost, and operability, and (3) evaluate technology readiness of the integrated system and identify specific technologies requiring development of advanced fossil-based sCO 2 cycles. Engineering evaluation is being applied to coal- and natural gas-fired thermal systems for sCO 2 power cycles to evaluate current boiler technologies and challenges associated with adapting those to a sCO 2 based configuration. This includes technical evaluation of the sCO 2 heat exchanger design and anticipated performance impacts on the thermal system. In addition to the general evaluation of indirect fossil fires closed Brayton sCO 2 cycles, this effort is also evaluating a novel indirect sCO 2 power cycle that utilizes an absorption/desorption circuit to minimize compression work by 40% to 65%. This translates to a thermodynamic cycle efficiency improvement of 3.2 points for a simple recuperated cycle using a binary CO 2 + Acetone working fluid.

20 FOSSIL-FUELED POWER PLANTS↗

Flammability of Materials on the Moon

Lunar gravity has been found to increase the limits of flammability for some materials compared to Earth gravity, presenting a goldilocks zone of reduced convective heat loss, while generating enough buoyant flow to replenish fresh oxygen into the flame zone. Combined with the elevated oxygen concentrations of planned Space Exploration Atmospheres (Sea), a long duration fire experiment in Lunar gravity is important to help understand and mitigate the increased risk. Flammability of Materials on the Moon (FM2) is a robotic, self-contained, combustion chamber which will be sent to the surface of the Moon on a Commercial Lunar Payload Services (CLPS) lander mission CP-21. The environmental control system can replicate and conduct fire experiments automatically in the expected atmospheres, specifically 21% oxygen at 14.7 psia, and 34% oxygen at 8.2 psia, which are of immediate interest to the Human Lander System (HLS) and Lunar Rover. The laboratory prototype became operational this summer. There are four samples currently planned; two SIBAL fabrics (cotton/fiberglass blend) which will be burned in air and two acrylic rods which will be burned in Normoxic Space Exploration Atmospheres (SEA). One of each fuel will be burned upward and downward. SIBAL fabric has been found to only burn downward in air in lunar gravity (via Lunar gravity centrifuge and parabolic flight) where on Earth’s gravity it extinguishes immediately after ignition.

Jennifer Zayac↗

Developing Standards to Qualify a Fine Water Mist Fire Extinguisher for Human Spaceflight

NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen systems increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide, so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. Compared to the carbon dioxide based Portable Fire Extinguisher, the flight qualification of Fine Water Mist systems requires special care. Qualification of the CO2 based Portable Fire Extinguisher began with the assumption that any fire on ISS would be extinguished if the air in the fire environment reached a critical concentration of CO2. Qualification of a CO2 based system requires the developers to make assertions and assumptions about vehicle geometry and the ability of the extinguisher to deliver CO2 in different geometric configurations, but the developers did not need to make assertions or assumptions about the size of the fire, the temperature, or the heat generation rate. Fine Water Mist systems extinguish a fire predominantly by removing heat -- so qualification standards must evaluate geometry, but also temperature, heat transfer, and heat generation rate. This paper outlines and describes the methods used to develop standards used to qualify Fine Water Mist systems for a human spaceflight environment.

Graf, John↗