Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Quantitative Infrared Image Analysis Of Thermally-Thin Cellulose Surface Temperatures During Upstream and Downstream Microgravity Flame Spread from A Central Ignition Line

Surface view calibrated infrared images of ignition and flame spread over a thin cellulose fuel were obtained at 30 Hz during microgravity flame spread tests in the 10 second Japan Microgravity Center (JAMIC). The tests also used a color video of the surface view and color images of the edge view using 35 millimeter 1600 Kodak Ektapress film at 2 Hz. The cellulose fuel samples (50% long fibers from lumi pine and 50% short fibers from birch) were made with an area density of 60 grams per square meters. The samples were mounted in the center of a 12 centimeter wide by 16 centimeter tall flow duct that uses a downstream fan to draw the air through the flow duct. Samples were ignited after the experiment package was released using a straight hot wire across the center of the 7.5 centimeter wide by 14 centimeter long samples. One case, at 1 atmosphere 35%O2 in N2, at a forced flow of 10 centimeters per second, is presented here. In this case, as the test progresses, the single flame begins to separate into simultaneous upstream and downstream flames. Surface temperature profiles are evaluated as a function of time, and temperature gradients for upstream and downstream flame spread are measured. Flame spread rates from IR image data are compared to visible image spread rate data. IR blackbody temperatures are compared to surface thermocouple readings to evaluate the effective emissivity of the pyrolyzing surface. Preheat lengths are evaluated both upstream and downstream of the central ignition point. A surface energy balance estimates the net heat flux from the flame to the fuel surface along the length of the fuel.

Olson, Sandra L.↗

Validation and Development of a Fast-Running CFD Model for the No-Vent Fill of Liquid Propellant Tank

Cryogenic fluids, while offering higher energy density than storable propellants, present several handling challenges, including gradual boil-off and tank self-pressurization. Transferring these propellants between tanks can be problematic, as the receiving tank's temperature and pressure often lead to flashing and rapid boil-off upon injection. The No-Vent Fill (NVF) technique mitigates these risks by preventing liquid fuel from being expelled overboard. By controlling tank pressure and ensuring appropriate condensation in the ullage region, the NVF process avoids exceeding vent pressure limits. In this study, Loci/STREAM-VOF simulations were compared with data from NASA K-site test runs on a 2.1 cubic meter tank with a bottom orifice under various no-vent fill conditions, including different wall temperatures, flow rates, and inlet liquid temperatures. The effort demonstrated that Loci/STREAM-VOF is capable of quantitatively capturing the important physics of NVF with submerged jets: (1) validation of the liquid-vapor interface turbulence velocity using previous experimental data showed good agreement at different fill levels; (2) validation of the CFD Stanton number for mass transfer provided an adequate mass transfer coefficient range; (3) consistent pressure agreements were found in the pressure history for both cold and warm conditions; and (4) the variations of final pressure with flow rate and inlet liquid temperature were well predicted by the CFD simulation. The application of NVF for low-gravity conditions will be studied in future work.

CFD↗

Validation and Development of a Fast-Running CFD Model for the No-Vent Fill of Liquid Propellant Tank

Cryogenic fluids, while offering higher energy density than storable propellants, present several handling challenges, including gradual boil-off and tank self-pressurization. Transferring these propellants between tanks can be problematic, as the receiving tank's temperature and pressure often lead to flashing and rapid boil-off upon injection. The No-Vent Fill (NVF) technique mitigates these risks by preventing liquid fuel from being expelled overboard. By controlling tank pressure and ensuring appropriate condensation in the ullage region, the NVF process avoids exceeding vent pressure limits. In this study, Loci/STREAM-VOF simulations were compared with data from NASA K-site test runs on a 2.1 cubic meter tank with a bottom orifice under various no-vent fill conditions, including different wall temperatures, flow rates, and inlet liquid temperatures. The effort demonstrated that Loci/STREAM-VOF is capable of quantitatively capturing the important physics of NVF with submerged jets: (1) validation of the liquid-vapor interface turbulence velocity using previous experimental data showed good agreement at different fill levels; (2) validation of the CFD Stanton number for mass transfer provided an adequate mass transfer coefficient range; (3) consistent pressure agreements were found in the pressure history for both cold and warm conditions; and (4) the variations of final pressure with flow rate and inlet liquid temperature were well predicted by the CFD simulation. The application of NVF for low-gravity conditions will be studied in future work.

CFD↗

DistOPF: Advanced Solutions for Distribution Optimal Power Flow Analysis - DistOPF v0.2 Documentation

To achieve an affordable and reliable energy system, research on power distribution system is often focused on integration of distributed generators, energy storage solution, EV charging, smart meters, and other advanced assets that may benefit from or require more advanced control and optimization techniques. Despite this focus on advanced distribution system topics, early researchers and grid scientists often start from scratch when developing optimization programs for power distribution systems. This report introduces DistOPF, a Python package that consolidates years of research into a versatile and modular tool. DistOPF provides researchers with essential capabilities to solve distribution system Optimal Power Flow (OPF) problems using standard network models. Additionally, it offers a platform to benchmark both new and existing algorithms against established test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulating Regional Groundwater Flow in the Vicinity of the Nevada National Security Site, Nye County, Nevada - 16104

The Death Valley Regional Groundwater Flow System (DVRFS) occupies an area of about 70,000 km{sup 2} in south-central Nevada and southeastern California. Interest in this system stems from the need to (1) understand the groundwater flow paths and travel times associated with potential migration of radioactive material from the Nevada National Security Site (NNSS) where underground nuclear testing was conducted from 1956 to 1992; (2) characterize the groundwater system in the vicinity of the proposed high-level radioactive waste repository at Yucca Mountain, Nev.; and (3) address a variety of potential effects from NNSS activities on users down gradient from the NNSS and Yucca Mountain. A single groundwater flow model of the DVRFS has been developed that integrates data and results of two previous regional-scale models and supports Department of Energy (DOE) programs at the NNSS. The numerical model was constrained by organizing hydrogeologic data and interpretations in three-dimensional (3D) geographic information systems and constructing a digital three-dimensional (3D) hydrogeologic framework model (HFM) to represent 27 hydrogeologic units (HGUs) and major structures in the DVRFS region. The 3D hydrogeologic data sets were discretized to 1,500 meters (m) grid cell resolution for input arrays required for the model. The DVRFS was simulated using the USGS 3D groundwater-flow modeling code MODFLOW-2000. Two examples showing how the DVRFS regional model is used by the DOE as part of waste management activities at the NNSS: (1) use of the regional model to provide the boundary conditions for site-scale models, and (2) use of the regional model to assess changes in hydraulic gradient and flow paths in the regional flow system resulting from changes in pumping in various areas of interest. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NASA Ames Laminar Flow Supersonic Wind Tunnel (LFSWT) Tests of a 10 deg Cone at Mach 1.6

This work is part of the ongoing qualification of the NASA Ames Laminar Flow Supersonic Wind Tunnel (LFSWT) as a low-disturbance (quiet) facility suitable for transition research. A 10 deg cone was tested over a range of unit Reynolds numbers (Re = 2.8 to 3.8 million per foot (9.2 to 12.5 million per meter)) and angles of incidence (O deg to 10 deg) at Mach 1.6. The location of boundary layer transition along the cone was measured primarily from surface temperature distributions, with oil flow interferometry and Schlieren flow visualization providing confirmation measurements. With the LFSWT in its normal quiet operating mode, no transition was detected on the cone in the test core, over the Reynolds number range tested at zero incidence and yaw. Increasing the pressure disturbance levels in the LFSWT test section by a factor of five caused transition onset on the cone within the test core, at zero incidence and yaw. When operating the LFSWT in its normal quiet mode, transition could only be detected in the test core when high angles of incidence (greater than 5 deg) for cones were set. Transition due to elevated pressure disturbances (Tollmien-Schlichting) and surface trips produced a skin temperature rise of order 4 F (2.2 C). Transition due to cross flows on the leeward side of the cone at incidence produced a smaller initial temperature rise of only order 2.5 F (1.4 C), which indicates a slower transition process. We can conclude that these cone tests add further proof that the LFSWT test core is normally low-disturbance (pressure fluctuations greater than 0.1%), as found by associated direct flow quality measurements discussed in this report. Furthermore, in a quiet test environment, the skin temperature rise is sensitive to the type of dominant instability causing transition. The testing of a cone in the LFSWT provides an excellent experiment for the development of advanced transition detection techniques.

Wolf, Stephen W. D.↗

Fluid property and operational effects on swirl injector atomization

Results of atomization tests of rocket injection elements are correlated in terms of the test fluid properties and the injection element operating conditions. The type of element modeled has a central, swirling liquid oxidizer flow; and a coaxial, axial gaseous fuel flow. Results of the correlations describe the effect of geometry, fluid properties, and operating conditions on liquid atomization. The ranges of test conditions allow reasonable extrapolation to actual high-pressure engine operating conditions. At such conditions, the swirl element should produce exceptionally finely-atomized and well-distributed spray for high combustion performance. United Technologies Research Center (UTRC) completed a test program to measure fluid spray atomization, in terms of droplet size and droplet size distributions, for swirling-flow injection elements. Element sizes and dimensions covered ranges of dimensions representative of typical cryogenic (O2/H2) liquid rocket engine practice. Relevant dimensions include the element diameter, the tangential-entry metering slot length, and the coastal fuel slot radial gap. Test fluids included water, simulated Jet-A, and Freon 113. These fluids cover ranges of properties which include or approach those of liquid oxygen. Gaseous nitrogen simulated the coaxial gaseous hydrogen fuel flow.

Cox, G. B., Jr.↗

Monitoring Hexavalent Chromium in the Columbia River Hypo-rheic Zone - 16405

Concentrations of hexavalent chromium in groundwater at the 100-BC reactor area, located on the U.S. Department of Energy's Hanford Site, exceed the State of Washington's surface water quality criterion of 10 μg/L. Groundwater discharge to the Columbia River is the primary pathway for contaminants to reach potential receptors. Additional monitoring was needed in order to make an informed decision about groundwater remediation. An array of 23 hypo-rheic sampling points (HSPs) was installed and monitored. The HSPs consist of stainless-steel tubing with 15-cm long mesh screens at depths ranging from 0.15 to 1 meter in the riverbed. The HSPs, which are fully submerged at all river stages, were installed and sampled from a boat using low-flow pumping. The HSPs provided permanent sampling points to obtain samples of hypo-rheic zone water. They were equally suitable for high-frequency sampling, with up to 48 samples collected from each HSP over a 4-day period, and long-term monitoring, with monthly grab samples collected over a 2-year period. The HSPs could be sampled at any river stage, which varied up to 3 meters daily and 4 meters seasonally. Pumping rates were kept low to ensure representative sampling and avoid hydraulic short-circuiting. Short-term increases in river stage did not suppress hexavalent chromium concentrations. Monthly sampling showed that hexavalent chromium concentrations and specific conductance did decline during periods of sustained, seasonally high river stage. Concentrations varied from <2 μg/L during high river stage to 25 μg/L during moderate to low river stage, compared to 50 to 60 μg/L in near-river monitoring wells. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recover Act. Verification of Geothermal Tracer Methods in Highly Constrained Field Experiments

The prediction of the geothermal system efficiency is strong linked to the character of the flow system that connects injector and producer wells. If water flow develops channels or “short circuiting” between injection and extraction wells thermal sweep is poor and much of the reservoir is left untapped. The purpose of this project was to understand how channelized flow develops in fracture geothermal reservoirs and how it can be measured in the field. We explored two methods of assessing channelization: hydraulic connectivity tests and tracer tests. These methods were tested at a field site using two verification methods: ground penetrating radar (GPR) images of saline tracer and heat transfer measurements using distributed temperature sensing (DTS). The field site for these studies was the Altona Flat Fractured Rock Research Site located in northeastern New York State. Altona Flat Rock is an experimental site considered a geologic analog for some geothermal reservoirs given its low matrix porosity. Because soil overburden is thin, it provided unique access to saturated bedrock fractures and the ability image using GPR which does not effectively penetrate most soils. Five boreholes were drilled in a “five spot” pattern covering 100 m2 and hydraulically isolated in a single bedding plane fracture. This simple system allowed a complete characterization of the fracture. Nine small diameter boreholes were drilled from the surface to just above the fracture to allow the measurement of heat transfer between the fracture and the rock matrix. The focus of the hydraulic investigation was periodic hydraulic testing. In such tests, rather than pumping or injection in a well at a constant rate, flow is varied to produce an oscillating pressure signal. This pressure signal is sensed in other wells and the attenuation and phase lag between the source and receptor is an indication of hydraulic connection. We found that these tests were much more effective than constant pumping tests in identifying a poorly connected well. As a result, we were able to predict which well pairs would demonstrate channelized flow. The focus of the tracer investigation was multi-ionic tests. In multi-ionic tests several ionic tracers are injected simultaneously and the detected in a nearby pumping well. The time history of concentration, or breakthrough curve, will show a separation of the tracers. Anionic tracers travel with the water but cationic tracer undergo chemical exchange with cations on the surface of the rock. The degree of separation is indicative of the surface area exposed to the tracer. Consequently, flow channelization will tend to decrease the separation in the breakthrough. Estimation of specific surface area (the ration of fracture surface area to formation volume) is performed through matching the breakthrough curve with a transport model. We found that the tracer estimates of surface area were confirmed the prediction of channelized flow between well pairs produced by the periodic hydraulic tests. To confirm that the hydraulic and tracer tests were correctly predicting channelize flow, we imaged the flow field using surface GPR. Saline water was injected between the well pairs which produced a change in the amplitude and phase of the reflected radar signal. A map was produced of the migration of saline tracer from these tests which qualitatively confirmed the flow channelization predicted by the hydraulic and tracer tests. The resolution of the GPR was insufficient to quantitatively estimate swept surface area, however. Surface GPR is not applicable in typical geothermal fields because the penetration depths do not exceed 10’s of meters. Nevertheless, the method of using of phase to measure electrical conductivity and the assessment of antennae polarization represent a significant advancement in the field of surface GPR. The effect of flow character on fracture / rock thermal exchange was evaluated using heated water as a tracer. Water elevated 30 degrees C above the formation water was circulated between two wells pairs. One well pair had been identified in hydraulic and tracer testing as well connected and the other poorly connected. Temperature rise was measured in the adjacent rock matrix using coiled fiber optic cable interrogated for temperature using a DTS. This experimental design produced over 4000 temperature measurements every hour. We found that heat transfer between the fracture and the rock matrix was highly impacted by the character of the flow field. The strongly connected wells which had demonstrated flow channelization produced heat rise in a much more limited area than the more poorly connected wells. In addition, the heat increase followed the natural permeability of the fracture rather than the induced flow field. The primary findings of this work are (1) even in a single relatively planar fracture, the flow field can be highly heterogeneous and exhibit flow channeling, (2) channeling results from a combination of fracture permeability structure and the induced flow field, and (3) flow channeling leads to reduced heat transfer. Multi-ionic tracers effectively estimate relative surface area but an estimate of ion-exchange coefficients are necessary to provide an absolute measure of specific surface area. Periodic hydraulic tests also proved a relative indicator of connectivity but cannot prove an absolute measure of specific surface area.

15 GEOTHERMAL ENERGY↗

Geosat Data Assimilation with Application to the Eastern North Atlantic

An attempt is made to determine the three-dimensional ocean circulation from satellite altimeter measurements by assimilating Geosat sea surface height data into an eddy-resolving QuasiGeostrophic (QG) model of the eastern North Atlantic Ocean. Results are tested against independent information from hydrographic field observations and moored current meter data collected during the Geosat ERM. The comparison supports the concept of inferring aspects of the three-dimensional flow field from sea surface height observations by combining altimetric measurements with the dynamics of ocean circulation models. A Holland-type QG model with open boundaries is set up on a 2000 km X 2000 km domain of the eastern North Atlantic between 25 deg. and 45 deg. N, 32 deg. and 8 deg. W. By using a simple nudging technique, about two years of Geosat altimeter data are assimilated into the model every five days as space-time objective analyses on the model grid. The error information resulting from the analysis is used during the assimilation procedure to account for data uncertainties. Results show an intense eddy field, which in the surface layer interacts with a meandering Azores Front. Compared to Geosat, the model leads to smoothed fields that follow the observations. Model simulations are significantly correlated with hydrographic data from March 1988 and June 1989, both close to the surface and in the subsurface. Good agreement is also found between the model velocity fields and moored current meter data in the top two model layers. The agreement is visually weak in the bottom layer, although a coherence analysis reveals an agreement between the model simulation and current meter data over the full water column at periods exceeding 80 days.

Stammer, Detlef↗

Dry calibration of electromagnetic flowmeters based on numerical models combining multiple physical phenomena (multiphysics)

This paper presents a method for dry calibration of an electromagnetic flowmeter (EMF). This method, which determines the voltage induced in the EMF as conductive liquid flows through a magnetic field, numerically solves a coupled set of multiphysical equations with measured boundary conditions for the magnetic, electric, and flow fields in the measuring pipe of the flowmeter. Specifically, this paper details the formulation of dry calibration and an efficient algorithm (that adaptively minimizes the number of measurements and requires only the normal component of the magnetic flux density as boundary conditions on the pipe surface to reconstruct the magnetic field involved) for computing the sensitivity of EMF. Along with an in-depth discussion on factors that could significantly affect the final precision of a dry calibrated EMF, the effects of flow disturbance on measuring errors have been experimentally studied by installing a baffle at the inflow port of the EMF. Results of the dry calibration on an actual EMF were compared against flow-rig calibration; excellent agreements (within 0.3%) between dry calibration and flow-rig tests verify the multiphysical computation of the fields and the robustness of the method. As requiring no actual flow, the dry calibration is particularly useful for calibrating large-diameter EMFs where conventional flow-rig methods are often costly and difficult to implement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary design of a helium cryogenic system for SAND detector at LBNF-DUNE near site

The Long-Baseline Neutrino Facility (LBNF) is providing a helium cryogenic system to support the superconducting solenoid magnet of the System for on-Axis Neutrino Detection (SAND) for the Deep Underground Neutrino Experiment (DUNE) Near Site at Fermilab in Batavia, IL. The design started in 2020 and construction is set to begin in the mid 2020‘s.The helium cryogenic system primarily consists of a helium refrigerator system, distribution valve boxes, vacuum-jacketed helium and nitrogen transfer lines, warm gaseous helium transfer system, instruments and control system, and gaseous helium storage tanks. It is designed to provide supercritical helium at around 3 bara and 5 K with expansion from 3 to 1.2 bara in the SAND cryostat and 70K forced cold gas helium to cool the thermal shields of the SAND cryostat. The SAND superconductive magnet is indirectly cooled through a liquid helium thermosiphon cycle. A pair of 3 kA leads is cooled by the gas helium vaporized from the liquid helium reservoir in the cryostat turret. The helium system will share the liquid nitrogen tank and liquid nitrogen phase separator with the Near Site Liquid Argon system. The helium recycle compressor system, GHe tanks and LN2 tank will be located on the Surface. The cryogenic facilities including refrigerator cold box, valve boxes and LN2 phase separator will be located on the shaft cryo-mezzanine in the underground cavern. The shaft connecting surface and cavern is more than 60 meter deep. The helium vacuum-jacketed transfer line between the cold box and the SAND magnet is more than 50 meter long. This paper presents the preliminary design of the helium cryogenic system including the design scheme, process flow diagram, heat load estimates, layout plan and so on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Completion Report for Model Evaluation Well ER-11-2: Corrective Action Unit 98: Frenchman Flat

Model Evaluation Well ER-11-2 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of Nevada Environmental Management Operations at the Nevada National Security Site (formerly known as the Nevada Test Site). The well was drilled in August 2012 as part of a model evaluation program in the Frenchman Flat area of Nye County, Nevada. The primary purpose of the well was to provide detailed geologic, hydrogeologic, chemical, and radionuclide data that can be used to test and build confidence in the applicability of the Frenchman Flat Corrective Action Unit flow and transport models for their intended purpose. In particular, this well was designed to provide data to evaluate the uncertainty in model forecasts of contaminant migration from the upgradient underground nuclear test PIN STRIPE, conducted in borehole U-11b in 1966. Well ER-11-2 will provide information that can be used to refine the Phase II Frenchman Flat hydrostratigraphic framework model if necessary, as well as to support future groundwater flow and transport modeling. The main 31.1-centimeter (cm) hole was drilled to a total depth of 399.6 meters (m). A completion casing string was not set in Well ER-11-2. However, a piezometer string was installed in the 31.1-cm open hole. The piezometer is composed of 7.3-cm stainless-steel tubing hung on 6.0-cm carbon-steel tubing via a crossover sub. The piezometer string was landed at 394.5 m, for monitoring the lower tuff confining unit. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 m, various geophysical logs, water quality (including tritium and other test-related radionuclides) measurements, and water level measurements. The well penetrated 42.7 m of Quaternary and Tertiary alluvium and 356.9 m of Tertiary volcanic rock. The water-level measured in the piezometer string on September 25, 2012, was 353.8 m below ground surface. No tritium above levels detectable by field methods were encountered in this hole. No well development or hydrologic testing was conducted in this well immediately after completion, and future well development, sampling, and hydrologic testing planned for this well will be limited due to the diameter of the piezometer string. The stratigraphy, general lithology, and the water level are as expected, but the section of geology encountered is higher than expected due to faulting. No tritium above the minimum detection limit of the field equipment was detected because the target aquifer (the Topopah Spring aquifer) at Well ER-11-2 is structurally higher than expected and thus unsaturated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of LI-1542 reusable surface insulation system in a hypersonic stream

The thermal and structural performance of a large panel of LI-1542 reusable surface insulation tiles was determined by a series of cyclic heating tests using radiant lamps and aerothemal tests in the Langley 8-foot high-temperature structures tunnel. Aerothermal tests were conducted at a free-stream Mach number of 6.6, a total temperature of 1830 K, Reynolds numbers of 2.0 and 4,900,000 per meter, and dynamic pressures of 29 and 65 kPa. The results suggest that pressure gradients in gaps and flow impingement on the header walls at the end of longitudinal gaps are sources for increased gap heating. Temperatures higher than surface radiation equilibrium temperature were measured deep in gaps and at the header walls. Also, the damage tolerance of the LI-1542 tiles appears to be very high. Tile edge erosion rate was slow; could not be tolerated in a shuttle application. Tiles soaked with water and subjected to rapid depressurization and aerodynamic heating showed no visible evidence of damage.

Hunt, L. R.↗

Design and subscale tests of a diffuser system for a Mach 4 scramjet test facility

A fixed-geometry diffuser system was designed for use in Mach 4 free-jet tests of a hydrogen-burning modular scramjet engine. The scramjet engine has a rectangular cross section that blocks up to 33 percent of the existing tunnel nozzle exit area and swept leading edges of the scramjet produce an asymmetric downward flow that sharply increases when the scramjet inlet unstarts. Effects of these conditions on the operation of the diffuser system are not accurately predictable. An experimental investigation has therefore been conducted in unheated air using a subscale model of the tunnel-scramjet-diffuser system to substantiate the design. Test results showed that the preliminary design had to be modified to obtain an acceptable configuration of the nozzle exit, test cabin, and diffuser that would provide shock-free flow at the scramjet inlet for simulated Mach 4 flight at altitudes from 16,764 to 20,422 meters.

Andrews, E. H., Jr.↗

Sorting Titanium Welding Rods

Three types of titanium welding wires identified by their resistance to current flow. Welding-wire tester quickly identifies unknown titaniumalloy wire by touching wire with test probe, and comparing meter response with standard response. Before touching wire, tip of test probe dipped into an electrolyte.

Ross, W. D., Jr.↗

Pre-existing seed particles and the onset of condensation in cryogenic wind tunnels

The condensation research at NASA Langley Research Center has used a variety of experimental approaches to gather information on seed particles that can act as sites for condensation growth. Total pressure measurements have suggested that condensation growth is caused by impurities in the flow and not by unevaporated liquid nitrogen (LN2) droplets resulting from the LN2 injected to cool the 0.3-Meter Transonic Cryogenic Tunnel. A separate test with an optical droplet sizing probe, which was designed to detect droplets in the 2- to 300-micron range, confirmed the conclusions from the total pressure measurements and also discovered what appears to be solidified oil droplets having diameters of about 3 microns. These oil droplets appear to be the dominant source of seed particles above 2 microns. However, computer simulations of static pressure test data suggest that the measured condensation effects are the result of more numerous, smaller seeds with number densities on the order of 10 to the 12th per kilogram of the gas and diameters on the order of 0.5 microns.

Hall, R. M.↗