Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Accuracy of Proton Beam Range Verification Using Post-Treatment Positron Emission Tomography/Computed Tomography as Function of Treatment Site

Purpose: For 23 patients, an off-line positron emission tomography scan and a computed tomography scan after proton radiotherapy was performed at the Massachusetts General Hospital to assess in vivo treatment verification. A well-balanced population of patients was investigated to assess the effect of the tumor location on the accuracy of the technique. Methods and Materials: Range verification was achieved by comparing the measured positron emission tomography activity distributions with the corresponding Monte Carlo-simulated distributions. Observed differences in the distal end of the activity distributions were analyzed as potential indicators for the range differences between the actual delivered and planned dose. Results: The average spatial agreement between the measured and simulated activity distribution was within {+-}3 mm, and the corresponding average absolute agreement was within {+-}45% (derived from gamma index analysis). The mean absolute range deviation at 93 randomly chosen positions in 17 treatment fields delivered to 11 patients was 3.6 mm. Characteristic differences in the agreement of the measured and simulated activity distribution for the different tumor/target sites were found. This resulted from the different effect of factors such as biologic washout effects, motion, or limitations in the Monte Carlo-simulated activity patterns. Conclusion: We found that intracranial and cervical spine patients can greatly benefit from off-line positron emission tomography and computed tomography range verification. However, for the successful application of the method to patients with abdominopelvic tumors, major technological and methodologic improvements are needed. Among the intracranial and cervical spine target sites, patients with arteriovenous malformations or metal implants represent groups that could especially benefit from the approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of a Novel Algorithm For Generating Synthetic CT Images From Magnetic Resonance Imaging Data Sets for Prostate Cancer Radiation Therapy

Purpose: To describe and evaluate a method for generating synthetic computed tomography (synCT) images from magnetic resonance simulation (MR-SIM) data for accurate digitally reconstructed radiograph (DRR) generation and dose calculations in prostate cancer radiation therapy. Methods and Materials: A retrospective evaluation was performed in 9 prostate cancer patients who had undergone MR-SIM in addition to CT simulation (CT-SIM). MR-SIM data were used to generate synCT images by using a novel, voxel-based weighted summation approach. A subset of patients was used for weight optimization, and the number of patients to use during optimization was determined. Hounsfield unit (HU) differences between CT-SIM and synCT images were analyzed via mean absolute error (MAE). Original, CT-based treatment plans were mapped onto synCTs. DRRs were generated, and agreement between CT and synCT-generated DRRs was evaluated via Dice similarity coefficient (DSC). Dose was recalculated, and dose-volume metrics and gamma analysis were used to evaluate resulting treatment plans. Results: Full field-of-view synCT MAE across all patients was 74.3 ± 10.9 HU with differences from CTs of 2.0 ± 8.1 HU and 11.9 ± 46.7 HU for soft tissue structures (prostate, bladder, and rectum) and femoral bones, respectively. Calculated DSCs for anterior-posterior and lateral DRRs were 0.90 ± 0.04 and 0.92 ± 0.05, respectively. Differences in D99%, mean dose, and maximum dose to the clinical target volume from CT-SIM dose calculations were 0.75% ± 0.35%, 0.63% ± 0.34%, and 0.54% ± 0.33%, respectively, for synCT-generated plans. Gamma analysis (2%/2 mm dose difference/distance to agreement) revealed pass rates of 99.9% ± 0.1% (range, 99.7%-100%). Conclusion: Generated synCTs enabled accurate DRR generation and dose computation for prostate MR-only simulation. Dose recalculated on synCTs agreed well with original planning distributions. Further validation using a larger patient cohort is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding of martensitic (TiCu)-based bulk metallic glasses through deformation behavior of a binary Ti{sub 50}Cu{sub 50} martensitic alloy

A binary Ti{sub 50}Cu{sub 50} martensitic alloy having similar atomic clusters to (TiCu)-based martensitic bulk metallic glasses presents a large plastic strain of 18.04% with high fracture strength of 1705 MPa. Detailed microstructural investigations point out that martensite embedded in {gamma}-TiCu matrix is effective to dissipate localization of the shear stress thus leading to rotational propagation, interaction, and multiplication of the shear bands. Furthermore, the propagation of microcracks formed by local stress transition during deformation is hindered by the martensite.

36 MATERIALS SCIENCE↗

SU-E-T-339: Dosimetric Verification of Acuros XB Dose Calculation Algorithm On An Air Cavity for 6-MV Flattening Filter-Free Beam

Purpose: This study was to verify the accuracy of Acuros XB (AXB) dose calculation algorithm on an air cavity for a single radiation field using 6-MV flattening filter-free (FFF) beam. Methods: A rectangular slab phantom containing an air cavity was made for this study. The CT images of the phantom for dose calculation were scanned with and without film at measurement depths (4.5, 5.5, 6.5 and 7.5 cm). The central axis doses (CADs) and the off-axis doses (OADs) were measured by film and calculated with Analytical Anisotropic Algorithm (AAA) and AXB for field sizes ranging from 2 Χ 2 to 5 Χ 5 cm{sup 2} of 6-MV FFF beams. Both algorithms were divided into AXB-w and AAA -w when included the film in phantom for dose calculation, and AXB-w/o and AAA-w/o in calculation without film. The calculated OADs for both algorithms were compared with the measured OADs and difference values were determined using root means squares error (RMSE) and gamma evaluation. Results: The percentage differences (%Diffs) between the measured and calculated CAD for AXB-w was most agreement than others. Compared to the %Diff with and without film, the %Diffs with film were decreased than without within both algorithms. The %Diffs for both algorithms were reduced with increasing field size and increased relative to the depth increment. RMSEs of CAD for AXB-w were within 10.32% for both inner-profile and penumbra, while the corresponding values of AAA-w appeared to 96.50%. Conclusion: This study demonstrated that the dose calculation with AXB within air cavity shows more accurate than with AAA compared to the measured dose. Furthermore, we found that the AXB-w was superior to AXB-w/o in this region when compared against the measurements.

60 APPLIED LIFE SCIENCES↗

MO-F-16A-05: Spot-Scanning Proton Therapy Patient-Specific Quality Assurance: Our Methodology and Results From 295 Treatment Plans

Purpose: To report on the patient-specific quality assurance (PSQA) results for 295 spot-scanning proton therapy treatment plans from the MD Anderson PTC-Houston. We show how the results differed by treatment site and how they were affected by the treatment plan optimization method and by a range shifter in the treatment field. We also discuss some causes of PSQA problems. Methods: The PSQA procedure, which is designed to verify both the accuracy of the treatment planning system's (Eclipse™ v8.9) dose calculations and the dose delivery of the Hitachi PROBEAT synchrotron, consists of (1) an end-to-end test in which the beam is delivered and measured at the prescribed gantry angle, and (2) additional dose plane measurements made from gantry angle 270°. HPlusQA™ software automatically performs the gamma analysis with criteria 3% (dose tolerance), 3 mm (distance-to-agreement, DTA) and 2%, 2 mm. Passing is defined as at least 90% of the pixels having a gamma score less than 1. Results: The PSQA gamma passing rate was 96.2% for 3%, 3 mm, and 85.3% for 2%, 2 mm. The rate depended on the treatment site. For example, the 3%, 3 mm passing rate was 95% for head and neck plans, vs 100% for prostate plans. The passing rates of multi- vs. single-field optimization plans did not significantly differ. However, the rate for fields with range shifters was 94.8±0.6%, vs 99.0±0.6% for those without (p = 0.002). Longitudinal dose gradients caused most of the low scores. Overestimation of the calculated dose proximal to the spread-out Bragg peak (SOBP) caused many of the others. Conclusion: The planned and delivered doses consistently agreed within tolerance levels. Minor dose modeling deficiencies remain proximal to the SOBP. The 3% dose tolerance, 3 mm DTA, with 90% pixel passing rate is a reasonable action level for 2D gamma comparisons.

60 APPLIED LIFE SCIENCES↗

SU-E-T-772: Uncertainties in Treatment Planning for IROC-Houston Proton Phantom QA Program Due to Variable CT Technique and Proton Energy

Purpose: To understand the uncertainties in proton therapy treatment planning for the IROC- Houston proton phantom QA program due to variations in CT technique and proton energy. Methods: A CT phantom used by IROC-H during therapy site visits was scanned using three CT techniques (80, 120, 140kV) with a CT scanner used for proton therapy simulations and irradiated with a passively scattered beam at three energies (140, 200, 250 MeV) to measure, respectively, HU and Relative Linear Stopping Power (RLSP) in order to create HU to RLSP calibration curves for comparison with reference curves used by current proton treatment planning systems. The phantom has proton equivalent materials with a wide variety of HU and RLSPs to allow for the creation of a calibration curve for common tissue equivalent materials. Treatment plans were created for a lung phantom using the various CT technique/ beam energy calibration curves to determine the differences in the dose distributions by performing a gamma analysis. Results: Comparison of the calibration curves created using the phantom materials showed a maximum difference of 12% for a given material between the custom curve and the reference curve currently used by the treatment planning system. The highest differences were a Result of using an 80 kV CT technique and a 250 MeV high proton energy. A comparison of the completed treatment plans will be presented. Conclusion: These results indicate the possibility of differences in proton HU to RLSP calibration curves caused by varying CT technique and proton energy that could manifest as differences in planned and delivered dose distributions, particularly at high proton energies and low kV CT techniques. These differences could Result in discrepancies not accounted for by IROC-Houston and could possibly affect proton institutions’ pass rate when irradiating the proton phantoms.

60 APPLIED LIFE SCIENCES↗

Spectrophotometry of beta Lyrae

Two hundred and fourteen scans over the wavelength region 1100 A to 1800 A with 10 A resolution were obtained by OAO spacecraft for the eclipsing binary Beta Lyrae between JD 2440889.5 and JD 2440904.5. Preliminary results indicate that: (1) The intensity at primary minimum is almost exactly one-half that at maximum and that the primary eclipse is less deep than that in the visual or longer ultraviolet wavelengths; (2) except for the 1100 to 1200 A region, the depth of the primary eclipse appears independent of wavelength; (3) the energy distribution at secondary minimum is similar to that at primary; (4) the two most prominent emission lines match well both with Si IV and C IV emission observed in gamma Vel and imply an exciting source of high temperature; (5) the emission lines do not show variation with phase.

Houck, T. E.↗

SU-E-T-609: Evaluation of Transit Dosimetry Software Using Heterogeneous Phantom

Purpose: The purpose of this work was to evaluate limits and capabilities in the transit dosimetry software for use with the TomoTherapy system by irradiating a heterogeneous phantom. Methods: Helical TomoTherapy plan was created using CIRS phantom (model 062M) with nine various tissue equivalent inserts (lung inhale 0.2 g/cm{sup 3}, lung exhale 0.5 g/cm{sup 3}, adipose 0.96 g/cm{sup 3}, breast 0.99 g/cm{sup 3}, water 1.01 g/cm{sup 3}, muscle 1.06 g/cm{sup 3}, liver 1.07 g/cm{sup 3}, trabecular bone 1.16 g/cm{sup 3}, and dense bone 1.53 g/cm{sup 3}). Targets were contoured within every insert. The phantom was scanned with a 50 cm field of view and 3 mm slice width. Images were imported into the TomoTherapy TPS. A plan was generated to deliver 20 Gy to every insert (2 Gy per fraction) with a jaw width of 2.5 cm, a pitch of 0.430 and an actual modulation factor of 2.621. After the radiation delivery the planning CT, the RT structure, the RT plan, and the RT dose (DICOM format) as well as the exit detector sinogram were imported into the Dosimetry Check software (Math Resolutions, LLC). The 3D delivered doses were reconstructed from the exit detector data by correcting for phantom and couch attenuation. The resulting dose distribution were compared with the TPS planned dose using gamma index. Results: Using the clinical gamma criteria, 3% and 3 mm, all tissue equivalent inserts had a passing percentage of 100% except for 0.2 g/cm{sup 3} and 0.5 g/cm{sup 3} density inserts (gamma value of 81.67% and 99.18% respectively). Conclusion: The evaluated transit dosimetry software provides an independent verification of helical TomoTherapy plans giving additional confidence in the treatment delivery, however, an overestimation of the reconstructed dose in low density materials has been revealed. Implementation of Monte Carlo algorithm for exit dose reconstruction should improve dosimetric accuracy in heterogeneous patient tissues. Agreement with Math Resolutions.

60 APPLIED LIFE SCIENCES↗

Gelatin-Derived Graphene–Silicate Hybrid Materials Are Biocompatible and Synergistically Promote BMP9-Induced Osteogenic Differentiation of Mesenchymal Stem Cells

Graphene-based materials are used in many fields but have found only limited applications in biomedicine, including bone tissue engineering. Here, we demonstrate that novel hybrid materials consisting of gelatin-derived graphene and silicate nanosheets of Laponite (GL) are biocompatible and promote osteogenic differentiation of mesenchymal stem cells (MSCs). Homogeneous cell attachment, long-term proliferation, and osteogenic differentiation of MSCs on a GL-scaffold were confirmed using optical microscopy and scanning electron microscopy. GL-powders made by pulverizing the GL-scaffold were shown to promote bone morphogenetic protein (BMP9)-induced osteogenic differentiation. GL-powders increased the alkaline phosphatase (ALP) activity in immortalized mouse embryonic fibroblasts but decreased the ALP activity in more-differentiated immortalized mouse adipose-derived cells. Note, however, that GL-powders promoted BMP9-induced calcium mineral deposits in both MSC lines, as assessed using qualitative and quantitative alizarin red assays. Furthermore, the expression of chondro-osteogenic regulator markers such as Runx2, Sox9, osteopontin, and osteocalcin was upregulated by the GL-powder, independent of BMP9 stimulation; although the powder synergistically upregulated the BMP9-induced Osterix expression, the adipogenic marker PPAR gamma was unaffected. Furthermore, in vivo stem cell implantation experiments demonstrated that GL-powder could significantly enhance the BMP9-induced ectopic bone formation from MSCs. Collectively, our results strongly suggest that the GL hybrid materials promote BMP9-induced osteogenic differentiation of MSCs and hold promise for the development of bone tissue engineering platforms.

Zou, Yulong↗

Mg and Al-induced phase transformation and stabilization of Ga 2 O 3 -based $\gamma$-phase spinels

Ga 2 O 3 films were deposited on (100) MgAl 2 O 4 spinel substrates at 550, 650, 750, and 850 °C using metal-organic chemical vapor deposition and investigated using x-ray diffraction and transmission electron microscopy. A phase-pure γ-Ga 2 O 3 -based material having an inverse spinel structure was formed at 850 °C; a mixture of the γ-phase and β-Ga 2 O 3 was detected in films grown at 750 °C. Only β-Ga 2 O 3 was determined in the films deposited at 650 and 550 °C. A β- to γ-phase transition occurred from the substrate/film interface during growth at 750 °C. The growth and stabilization of the γ-phase at the outset of film growth at 850 °C was affected by the substantial Mg and Al chemical interdiffusion from the MgAl 2 O 4 substrate observed in the energy-dispersive x-ray spectrum. Further, atomic-scale investigations via scanning transmission electron microscopy of the films grown at 750 and 850 °C revealed a strong tetrahedral site preference for Ga and an octahedral site preference for Mg and Al. It is postulated that the occupation of these atoms in these particular sites drives the β-Ga 2 O 3 to γ-phase transition and markedly enhances the thermal stability of the latter phase at elevated temperatures.

42 ENGINEERING↗

Formation and Morphology of "shish-like" Fibril Crystals of Aliphatic Polyesters from the Sheared Melt

We found the formation of 'shish-like' fibril crystals of aliphatic polyesters such as poly(L-lactic acid) (PLLA), poly({var_epsilon}-caprolactone) (PCL), poly(12-hydroxydodecanoic acid) (PHDA) and poly(16-hydroxyhexadecanoic acid) (PHHA) from the sheared melt with shear rate {gamma} = 5 s{sup -1} observed by polarizing optical microscope (POM). The melting temperature T{sub m}s of obtained fibril crystals of PLLA and PCL were higher than those of spherulites and were close to the equilibrium melting temperature T{sub m}{sup 0}. The small angle X-ray scattering (SAXS) patterns from the bulk sample including fibril crystals, small amount of unoriented small crystals and amorphous showed no peaks arose from the existence of long periods in fibril crystals. These are the evidence that the observed fibril crystals consist of assemblies of a lot of extended chain crystals (ECCs). We observed the morphology of moderately extracted single strand of fibril crystals at the magnification of POM by means of scanning electron microscope. We found that macroscopic fibril crystals of PLLA with diameter d = 10 {micro}m consist of the bundle structure of microscopic fibril crystals with d = 2 {micro}m. From POM observation of the formation of fibril crystals of PLLA and PCL, we showed phase diagrams of molecular weight M and crystallization temperature T{sub c} for the formation of fibril crystals. From these phase diagrams, we evaluated a critical M and T{sub c} for the formation of fibril crystals. Moreover, from the sequential melting and crystallization experiments, it was implied that the entanglement and transesterification play an important role on the formation of fibril crystals of aliphatic polyesters.

36 MATERIALS SCIENCE↗

TH-A-BRF-03: Evaluation of Synthetic CTs Generated Using MR-SIM Data

Purpose: To describe and evaluate a novel algorithm for generating synthetic CT images from MR-SIM data for dose calculations in MR-only treatment planning. Methods: A voxel-based weighted summation method was implemented to generate synthetic CT (synCT) images. MR data were acquired using Philips 1.0T Panorama high-field open MR-SIM. Retrospective patient data from seven prostate patients and one brain patient (three lesions) enrolled in an IRB-approved study were used. 3D T1-weighted fast field echo and 3D T2-weighted turbo spin echo sequences were utilized for all patients. A 3D balanced turbo field echo sequence using spectral presaturation with inversion recovery was acquired for prostate patients, but 3D ultra-short echo time (UTE)-DIXON was instead acquired for the brain patient to amplify bone signal for semi-automatic bone segmentation. Weight optimization was performed using a training subset of patients. HU value differences between planning CT and synCTs were analyzed using mean absolute error (MAE). Original patient CT-based treatment plans were mapped onto synCTs, dose was recalculated using original leaf motion and MU values, and DRRs were generated. Dosevolume metrics and gamma analysis were used for dosimetric evaluation. Results: Average whole-body MAE of synCTs across all patients was 75+12 HU. In prostate cancer patients, average HU difference between planning and synCTs was 0.9±1.0% for soft tissue structures and 4.3±2.5% for bony structures. DRRs were generated from synCTs and qualitatively showed good geometric agreement with planning CT-generated DRRs. D99, mean dose, and maximum dose to CTV calculated using the synCT remained within 1.2% of planning CT-based dose calculations. All gamma analysis evaluated at 2%/2mm dose difference/distance to agreement) pass rates were greater than 95% with an average of 99.9±0.1% for prostate patients and 98.4±2.2% for three brain lesions. Conclusion: SynCTs were generated with clinically acceptable accuracy comparable to planning CTs, enabling dose computations for MR-only simulation. Research supported in part by a grant from Philips HealthCare (Best, Netherlands)

60 APPLIED LIFE SCIENCES↗

Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method

Purpose:A dosimetric system formed by Gafchromic EBT2 radiochromic film and Epson Expression 10000XL flatbed scanner was commissioned for dosimetry. In this paper, several open questions concerning the commissioning of radiochromic films for dosimetry were addressed: (a) is it possible to employ this dosimetric system in reflection mode; (b) if so, can the methods used in transmission mode also be used in reflection mode; (c) is it possible to obtain accurate absolute dose measurements with Gafchromic EBT2 films; (d) which calibration method should be followed; (e) which calibration models should be used; and (f) does three-color channel dosimetry offer a significant improvement over single channel dosimetry. The purpose of this paper is to help clarify these questions. Methods: In this study, films were scanned in reflection mode, the effect of surrounding film was evaluated and the feasibility of EBT2 film dosimetry in reflection mode was studied. EBT2's response homogeneity has been reported to lead to excessive dose uncertainties. To overcome this problem, a new plan-based calibration method was implemented. Plan-based calibration can use every pixel and each of the three color channels of the scanned film to obtain the parameters of the calibration model. A model selection analysis was conducted to select lateral correction and sensitometric curve models. The commonly used calibration with fragments was compared with red-channel plan-based calibration and with three-channel plan-based calibration. Results: No effect of surrounding film was found in this study. The film response inhomogeneity in EBT2 films was found to be important not only due to differences in the fog but also due to differences in sensitivity. The best results for lateral corrections were obtained using absolute corrections independent of the dose. With respect to the sensitometric curves, an empirical polynomial fit of order 4 was found to obtain results equivalent to a gamma-distributed single hit model based on physical assumptions. Three-channel dosimetry was found to be substantially superior to red-channel dosimetry. Conclusions: Reflection mode with Gafchromic EBT2 radiochromic film was found to be a viable alternative to transmission mode. The same methods that are used in transmission mode can be followed in reflection mode. A novel plan-based method was developed for calibration and multichannel dosimetry. This novel method offers increased robustness against film response inhomogeneities and reduces considerably the time required for calibration.

60 APPLIED LIFE SCIENCES↗

SU-E-T-678: Response Calibration Using Electron Depth-Dose Data for MRI-Based 3D Polymer Gel Dosimetry

Purpose: To evaluate a calibration method using the depth-dose data of an electron beam for MRI-based polymer gel dosimetry. Methods: MAGAT was manufactured in-house to fill two 400mL-cylindrical phantoms and nine 22mL-glass vials. Phantom-A was irradiated along the cylinder axis with a 9MeV electron beam of 6 cm x 6 cm field size (FS). Phantom-B was irradiated with a 6MV photon beam of 3 cm x 3 cm FS by a 360-degree arc technique. Eight vials were irradiated in a water-bath to various doses with a 20 cm x 20 cm FS 6MV photon beam. All irradiated phantoms and one un-irradiated vial were scanned with a 3T MRI scanner to obtain the spin-spin relaxation rate (R2) distributions. By comparing the measured R2-to-depth data with the known depth-dose data for Phantom-A, R2-to-dose calibration data were obtained (e-beam method). Another calibration data were obtained from the 9 vials data (9-vial method). We tested two regression equations, i.e., third-order polynomial and tangent functions, and two dose normalization methods, i.e., one-point and two-point methods. Then, these two calibration methods were used to obtain the 3D dose distribution of Phantom-B and evaluated by comparing the measured data with the dose distribution from a treatment planning system. The comparison was made with gamma passing rate (2%/2mm criteria). Results: We did not observe a clear advantage of the e-beam method over the 9-vial method for the 3D dose comparison with the test case. Nevertheless, we found that the e-beam method required a smaller dose scaling for the dose comparison. Furthermore, the tangent function showed better data fitting than the polynomial function with smaller uncertainty of the estimated coefficients. Conclusions: Considering the overall superior performance, we recommend the e-beam method with the tangent function as the regression equation and one-point dose normalization for the MRI-based polymer gel dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

60 APPLIED LIFE SCIENCES↗

Retrievals of Cloud Droplet Size from the RSP Data: Validation Using in Situ Measurements

We present comparisons of cloud droplet size distributions retrieved from the Research Scanning Polarimeter (RSP) data with correlative in situ measurements made during the North Atlantic Aerosols and Marine Ecosystems Study (NAAMES). This field experiment was based at St. Johns airport, Newfoundland, Canada with the latest deployment in May - June 2016. RSP was onboard the NASA C-130 aircraft together with an array of in situ and other remote sensing instrumentation. The RSP is an along-track scanner measuring polarized and total reflectances in9 spectral channels. Its unique high angular resolution allows for characterization of liquid water droplet size using the rainbow structure observed in the polarized reflectances in the scattering angle range between 135 and 165 degrees. A parametric fitting algorithm applied to the polarized reflectances provides retrievals of the droplet effective radius and variance assuming a prescribed size distribution shape (gamma distribution). In addition to this, we use a non-parametric method, Rainbow Fourier Transform (RFT), which allows us to retrieve the droplet size distribution (DSD) itself. The latter is important in the case of clouds with complex structure, which results in multi-modal DSDs. During NAAMES the aircraft performed a number of flight patterns specifically designed for comparison of remote sensing retrievals and in situ measurements. These patterns consisted of two flight segments above the same straight ground track. One of these segments was flown above clouds allowing for remote sensing measurements, while the other was at the cloud top where cloud droplets were sampled. We compare the DSDs retrieved from the RSP data with in situ measurements made by the Cloud Droplet Probe (CDP). The comparisons show generally good agreement with deviations explainable by the position of the aircraft within cloud and by presence of additional cloud layers in RSP view that do not contribute to the in situ DSDs. In the latter case the distributions retrieved from the RSP data were consistent with the multi-layer cloud structures observed in the correlative High Spectral Resolution Lidar (HSRL) profiles. The comparison results provide a rare validation of polarimetric droplet size retrieval techniques, which can be used for analysis of satellite data on global scale.

cloud droplets↗

SU-E-T-360: End-To-End Dosimetric Testing of a Versa HD Linear Accelerator with the Agility Head Modeled in Pinnacle3

Purpose: The Versa HD incorporates a variety of upgrades, primarily including the Agility head. The distinct dosimetric properties of the head from its predecessors combined with flattening-filter-free (FFF) beams require a new investigation of modeling in planning systems and verification of modeling accuracy. Methods: A model was created in Pinnacle{sup 3} v9.8 with commissioned beam data. Leaf transmission was modeled as <0.5% with maximum leaf speed of 3 cm/s. Photon spectra were tuned for FFF beams, for which profiles were modeled with arbitrary profiles rather than with cones. For verification, a variety of plans with varied parameters were devised, and point dose measurements were compared to calculated values. A phantom of several plastic water and Styrofoam slabs was scanned and imported into Pinnacle{sup 3}. Beams of different field sizes, SSD, wedges, and gantry angles were created. All available photon energies (6 MV, 10 MV, 18 MV, 6 FFF, 10 FFF) as well four clinical electron energies (6, 9, 12, and 15 MeV) were investigated. The plans were verified at a calculation point (8 cm deep for photons, variable for electrons) by measurement with a PTW Semiflex ionization chamber. In addition, IMRT testing was performed with three standard plans (step and shoot IMRT, small and large field VMAT plans). The plans were delivered on the Delta4 IMRT QA phantom (ScandiDos, Uppsala, Sweden). Results: Homogeneous point dose measurement agreed within 2% for all photon and electron beams. Open field photon measurements along the central axis at 100 cm SSD passed within 1%. Gamma passing rates were >99.5% for all plans with a 3%/3mm tolerance criteria. The IMRT QA results for the first 23 patients yielded gamma passing rates of 97.4±2.3%. Conclusion: The end-to-end testing ensured confidence in the ability of Pinnacle{sup 3} to model photon and electron beams with the Agility head.

60 APPLIED LIFE SCIENCES↗

Why accredit ISO/CEI 17025 a nuclear waste management laboratory? - 15112

When there is no storage, nor repository, available on a site, the entity in charge of nuclear waste management should find outlets in order to evacuate outside the site. Each outlet has his rules and waste acceptance criteria (packaging rules, physical/chemical/radiological criteria for example). Before you are able to evacuate your waste, an acceptance's process (or contract review) takes place. This process scans the entire measures implemented by the site in order to satisfy outlet's criteria. When the acceptance is obtained, shipments could be organized, and the process gets into an observation's phase. During this phase, the outlet could choose to inspect a finished nuclear waste package or to audit regularly the waste management process. In this last case, the outlet re-scans the entire documents and implemented measures. This audit lasts from one to several days. A way to tackle/approach the audit is to acknowledge, by a trusted third party (i.e. independent from the outlet), all or part of waste management system, in order to base one's reputation on this organism and win outlet's trust. For this purpose, the entity could choose certification or accreditation. Certification (ISO 9001 as often as not) aims at evaluating a system for managing the quality of one product or service. Accreditation (ISO 17025, for example) provides formal recognition for technical skills within a quality management system (clauses 5 and 4 of the ISO 17025 standard). In 2006, the LDM laboratory is the first French laboratory accredited, in accordance with ISO 17025 standard, for the characterization by gamma spectrometry on 100 L- and 200 L- radioactive waste drums (accreditation No 1-1712 - scope available on www.cofrac.fr). This accreditation allows the lab: - to update the quality management system, - to compile the entire technical file of the gamma-ray assay (description, evaluation of the uncertainties, calibration, proficiency testing programs, measurement procedures,...), - to pass previous identified constraints on to producers and nuclear waste package production, - to maintain permanent quality improvement loop, - to lighten the programs of outlets audits, through the acknowledgement of the technical competence of the laboratory to evaluate by gamma spectrometry the activity contained in our nuclear waste drums. On the other hand, the lab is re-evaluated periodically to ensure its continued compliance with requirements: within a 12 month's interval for an internal audit, with a 18 month's period for COFRAC (French sole official national accreditation body). Since 2006, the lab is accredited. His accreditation renewed in 2010. A new entire renewal audit is planned in 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗