Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

FFTF main heat transport system/dump heat exchanger testing and performance evaluation (initial pub date April 1978)

This report covers testing of a Main Heat Transport System/Dump Heat Exchanger (MHTS/DHX) for the Fast Flux Test Facility. The primary objective of the test program was to verify the design and generate experience in the installation, operation, and control of the DHX for FFTF. This report discusses test results related to erection, preoperational testing, in-service inspections, and steady-state and transient performance. Emphasis is placed on the effect of the test results on successful DHX operation at FFTF. 36 figures, 9 tables.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data, exergy, and energy analysis of a vertical-bore, ground-source heat pump to for domestic water heating under simulated occupancy conditions

Evidence is provided to support the view that greater than two-thirds of energy required to produce domestic hot water may be extracted from the ground which serves as renewable energy resource. The case refers to a 345 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days (3993 F-days) and CDD of 723 C-days (1301 F-days). The house is operated under simulated occupancy conditions in which the hot water use protocol is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which captures the water consumption lifestyles of the average family in the United States. The 5.275 (1.5-ton) water-to-water ground source heat pump (WW-GSHP) shared the same vertical bore with a 7.56 KW water-to-air ground source heat pump for space conditioning the same house. Energy and exergy analysis of data collected continuously over a twelve month period provide performance metrics and sources of inherent systemic inefficiencies. Data and analyses are vital to better understand how WW-GSHPs may be further improved to enable the ground to be used as a renewable energy resource.

15 GEOTHERMAL ENERGY↗

Heat shock protein 70 and heat shock protein 90 synergistically increase hepatitis B viral capsid assembly

Highlights: • Heat shock protein 70 (Hsp70) interacts with Cp149 dimer. • Hsp70 synergistically increases formation of HBV capsid with Hsp90. • Inhibition of Hsp70 reduces HBV biogenesis through suppression of HBV capsid assembly. Hepatitis B virus (HBV) infection can cause chronic liver diseases, cirrhosis, and hepatocellular carcinoma (HCC). Heat shock proteins (Hsps) are important factors in the formation of the HBV capsid and in genome replication during the viral life cycle. Hsp90 is known to promote capsid assembly. However, the functional roles of Hsp70 in HBV capsid assembly with Hsp90 have not been studied so far. Using microscale thermophoresis analyses and in vitro nucleocapsid formation assays, we found that Hsp70 bound to a HBV core protein dimer and facilitated HBV capsid assembly. Inhibition of Hsp70 by methylene blue (MB) led to a decrease in capsid assembly. Moreover, Hsp70 inhibition reduced intracellular capsid formation and HBV virus particle number in HepG2.2.15 cells. Furthermore, we examined synergism between Hsp70 and Hsp90 on HBV capsid formation in vitro. Our results clarify the role of Hsp70 in HBV capsid formation via an interaction with core dimers and in synergistically promoting capsid assembly with Hsp90.

60 APPLIED LIFE SCIENCES↗

Mixed convection heat transfer in a differentially heated cavity with two rotating cylinders

Mixed convection heat transfer in a differentially heated cavity with two rotating cylinders was studied numerically for various pertinent parameters such as Richardson number, Reynolds number, non-dimensional rotation speed of the cylinder, and the location of the cylinders. The results from these simulations were validated using an open-source spectral element code, Nek5000. The results of this study were presented in terms of streamlines, isotherms, local and average Nusselt number, and temperature profiles. The results illustrated that the average Nusselt number depends strongly on the rotation speed of the cylinder, Reynolds number, and Richardson number. However, the average Nusselt number was found to be independent of the rotation speed at high Richardson number (Ri = 10). In addition, the direction of the rotation speed of the cylinders has a profound effect on the average Nusselt. Finally, the study illustrated that the magnitude and direction of the rotation speed of the cylinders have a significant effect on the flow pattern and isotherms.

42 ENGINEERING↗