Search NASA⌕ Search

SEARCH · Search NASA

Results for “High resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

New spectral features of stratospheric trace gases identified from high-resolution infrared balloon-borne and laboratory spectra

A new Michelson-type interferometer system operating in the infrared at very high resolution has been used to record numerous balloon-borne solar absorption spectra of the stratosphere, ground-based solar absorption spectra, and laboratory spectra of molecules of atmospheric interest. In the present work results obtained for several important stratospheric trace gases, HNO3, CIONO2, HO2NO2, NO2, and COF2, in the 8- to 12-micron spectral region are reported. Many new features of these gases have been identified in the stratospheric spectra. Comparison of the new spectra with line-by-line simulations shows that previous spectral line parameters are often inadequate and that new analysis of high-resolution laboratory and atmospheric spectra and improved theoretical calculations will be required for many bands. Preliminary versions of several sets of improved line parameters under development are discussed.

Goldman, A.↗

Lycoris - A large-area, high resolution beam telescope

We note that a high-resolution beam telescope is one of the most important and demanding infrastructure components at any test beam facility. Its main purpose is to provide reference particle tracks from the incoming test beam particles to the test beam users, which allows measurement of the performance of the device-under-test (DUT). LYCORIS, a six-plane compact beam telescope with an active area of ~ 10 x 10 cm 2 (extensible to 10 x 20 cm 2 ) was installed at the DESY II Test Beam Facility in 2019, to provide a precise momentum measurement in a 1 T solenoid magnet or to provide tracking over a large area. The overall design of Lycoris will be described as well as the performance of the chosen silicon sensor. The 25 μm pitch micro-strip sensor used for Lycoris was originally designed for the SiD detector concept for the International Linear Collider. It adopts a second metallization layer to route signals from strips to the bump-bonded KPiX ASIC and uses a wire-bonded flex cable for the connection to the DAQ and the power supply system. This arrangement eliminates the need for a dedicated hybrid PCB. Its performance was tested for the first time in this project. The system has been evaluated at the DESY II Test Beam Facility in several test-beam campaigns and has demonstrated an average single-point resolution of 7.07 μm.

47 OTHER INSTRUMENTATION↗

Deriving Iodine-free Spectra for High-resolution Echelle Spectrographs

We describe a new method to derive clean, iodine-free spectra directly from observations acquired using high-resolution echelle spectrographs equipped with iodine cells. The main motivation to obtain iodine-free spectra is to use portions of the spectrum that are superimposed with the dense forest of iodine absorption lines, in order to retrieve lines that can be used to monitor the magnetic activity of the star, helping to validate candidate planets. In short, we provide a straightforward methodology to clean the spectra using the forward model used to derive radial velocities, the line spread function information plus the stellar spectrum without iodine to reconstruct and subtract the iodine spectrum from the observations. We show our results using observations of the star τ Ceti acquired with the Planet Finder Spectrograph (PFS), High Resolution Echelle Spectrometer (HIRES), and University College London Echelle Spectrograph (UCLES), reaching an iodine-free spectrum correction at the ∼1% rms level. We additionally discuss the limitations and further applications of the method.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved simulation of extreme precipitation in a high-resolution atmosphere model

Climate models often underestimate the magnitude of extreme precipitation. We compare the performance of a high-resolution (~0.25°) time-slice atmospheric simulation (1979–2005) of the Community Earth System Model 1.0 in representing daily extreme precipitation events against those of the same model at lower resolutions (~1° and 2°). We find significant increases in the simulated levels of daily extreme precipitation over Europe, the United States, and Australia. In many cases the increase in high percentiles (>95th) of daily precipitation leads to better agreement with observational data sets. For lower percentiles, we find that increasing resolution does not significantly increase values of simulated precipitation. We argue that the reduced biases mainly result from the higher resolution models resolving more key physical processes controlling heavy precipitation. Lastly, we conclude that while high resolution is vital for accurately simulating extreme precipitation, considerable biases remain at the highest available model resolutions.

54 ENVIRONMENTAL SCIENCES↗

A non-LTE model for the Jovian methane infrared emissions at high spectral resolution

High resolution spectra of Jupiter in the 3.3 micrometer region have so far failed to reveal either the continuum or the line emissions that can be unambiguously attributed to the nu(sub 3) band of methane (Drossart et al. 1993; Kim et al. 1991). Nu(sub 3) line intensities predicted with the help of two simple non-Local Thermodynamic Equilibrium (LTE) models -- a two-level model and a three-level model, using experimentally determined relaxation coefficients, are shown to be one to three orders of magnitude respectively below the 3-sigma noise level of these observations. Predicted nu(sub 4) emission intensities are consistent with observed values. If the methane mixing ratio below the homopause is assumed as 2 x 10(exp -3), a value of about 300 K is derived as an upper limit to the temperature of the high stratosphere at microbar levels.

Halthore, Rangasayi N.↗

Fast high-resolution prediction of multi-phase flow in fractured formations

The success of a thermal water flood for enhanced oil recovery (EOR) depends on a detailed representation of the geometrical and hydraulic properties of the fracture network, which induces discrete, channelized flow behavior. The resulting high-resolution model is typically computationally very demanding. Here, we use the Proper Orthogonal Decomposition Mapping Method to reconstruct high-resolution solutions based on efficient low-resolution solutions. The method requires training a reduced order model (ROM) using high- and low-resolution solutions determined for a relatively short simulation time. For a cyclic EOR operation, the oil production rate and the heterogeneous structure of the oil saturation are accurately reproduced even after 105 cycles, reducing the computational cost by at least 85%. Finally, the method described is general and can be potentially utilized with any multiphase flow model.

54 ENVIRONMENTAL SCIENCES↗

Development of a lab-scale, high-resolution, tube-generated X-ray computed-tomography system for three-dimensional (3D) materials characterization

The design and construction of a modular high resolution X-ray computed tomography (XCT) system is highlighted in this paper. The design approach is detailed for meeting a specified set of instrument performance goals tailored towards experimental versatility and high resolution imaging. The XCT tool is unique in the detector and X-ray source design configuration, enabling control in the balance between detection efficiency and spatial resolution. The system package is also unique: The sample manipulation approach implemented enables a wide gamut of in situ experimentation to analyze structure evolution under applied stimulus, by optimizing scan conditions through a high degree of controllability. The component selection and design process is detailed: Incorporated components are specified, custom designs are shared, and the approach for their integration into a fully functional XCT scanner is provided. Custom designs discussed include the dual-target X-ray source cradle which maintains position and trajectory of the beam between the two X-ray target configurations with respect to a scintillator mounting and positioning assembly and the imaging sensor, as well as a novel large-format X-ray detector with enhanced adaptability. The instrument is discussed from an operational point of view, including the details of data acquisition and processing implemented for 3D imaging via micro-CT. The performance of the instrument is demonstrated on a silica-glass particle/hydroxyl-terminated-polybutadiene (HTPB) matrix binder PBX simulant. Post-scan data processing, specifically segmentation of the sample's relevant microstructure from the 3D reconstruction, is provided to demonstrate the utility of the instrument. - Highlights: • Custom built X-ray tomography system for microstructural characterization • Detector design for maximizing polychromatic X-ray detection efficiency • X-ray design offered for maximizing X-ray flux with respect to imaging resolution • Novel lab-scale XCT data acquisition and data processing methods • 3D characterization of glass-bead mock plastic-bonded-explosive stimulant.

36 MATERIALS SCIENCE↗

HIGH-RESOLUTION CH OBSERVATIONS OF TWO TRANSLUCENT MOLECULAR CLOUDS

We present high-resolution (1.'3 x 1.'6) observations of the CH {sup 2}{pi}{sub 1/2} (F = 1-1) emission line at 3335 MHz in two high-latitude translucent clouds, MBM 3 and 40. At the assumed cloud distances, the angular resolution corresponds to {approx}0.05 pc, nearly an order of magnitude better than previous studies. Comparisons of the CH emission with previously obtained CO(1-0) data are difficult to interpret: the CO and CH line emission correlates in MBM 40 but not in MBM 3. In both clouds, there is a spatial offset in the peak emission, and perhaps in velocity for MBM 40. The difference in emission characteristics for the two tracers are noticeable in these two nearby clouds because of the high spatial resolution. Since both CH and CO are deemed to be reliable tracers of H{sub 2}, our results indicate that more care should be taken when using one of these tracers to determine the mass of a nearby molecular cloud.

79 ASTRONOMY AND ASTROPHYSICS↗

The Usefulness of Ultra-High Resolution Microstructural Studies for Understanding Localized Corrosion Behavior of Al Alloys

The corrosion behavior of different tempers of two aluminum alloys, AA7050 and an experimental Al-Mg-Cu-Si alloy, was studied in NaCl solution by anodic polarization and scanning electron microscopy and was correlated with differences in the microstructure. Potentiodynamic polarization experiments were performed on samples from the exact sheets used by others to study the microstructure evolution during the early stages of the precipitation sequence by high-resolution characterization tools [i.e., high-resolution transmission electron microscopy and atom probe tomography (APT)]. The usefulness of information from these state-of-the-art tools to lead to a better understanding about the effects of nanoscale segregation on localized corrosion of aluminum alloys is discussed. APT was able to provide information about the composition of the solid solution matrix region between the fine-scale hardening particles, which is not possible by any other technique. Some of the changes in corrosion behavior, e.g., the breakdown potentials, with temper could be rationalized based on changes in the matrix composition. The formation of corrosion-susceptible surface layers on as-polished AA7050 depended on the predominant type of hardening particle. The lack of detailed knowledge of the grain boundary region limited the applicability of the microstructural information generated by previous studies for understanding intergranular corrosion.

Kappes, M.↗

Detection and Bulk Properties of the HR 8799 Planets with High-resolution Spectroscopy

Using the Keck Planet Imager and Characterizer, we obtained high-resolution (R ~ 35,000) K-band spectra of the four planets orbiting HR 8799. We clearly detected H{sub 2}O and CO in the atmospheres of HR 8799 c, d, and e, and tentatively detected a combination of CO and H{sub 2}O in b. These are the most challenging directly imaged exoplanets that have been observed at high spectral resolution to date when considering both their angular separations and flux ratios. We developed a forward-modeling framework that allows us to jointly fit the spectra of the planets and the diffracted starlight simultaneously in a likelihood-based approach and obtained posterior probabilities on their effective temperatures, surface gravities, radial velocities, and spins. We measured vsin (i) values of 10.1{sub -2.7}{sup +2.8} km s{sup -1} for HR 8799 d and 15.0{sub -2.6}{sup +2.3} km s{sup -1} for HR 8799 e, and placed an upper limit of <14 km s{sup -1} of HR 8799 c. Under two different assumptions of their obliquities, we found tentative evidence that rotation velocity is anticorrelated with companion mass, which could indicate that magnetic braking with a circumplanetary disk at early times is less efficient at spinning down lower-mass planets.

74 ATOMIC AND MOLECULAR PHYSICS↗

Gas-phase fragmentation studies of cyclic oligo-β-(1→6)-D-glucosamines by electrospray ionization mass spectrometry using a hybrid high-resolution mass spectrometer

Positive and negative ion high-resolution electrospray ionization mass spectra (MS and MS{sub 2}) of cyclooligo-β-(1→6)-D-glucosamines and cyclooligo-β-(1→6)-N-acetyl-D-glucosamines were acquired and interpret. It was shown that the cleavages of glycosidic bonds are the main processes in the decay of protonated and metallated molecules. In addition, elimination of the water molecules (and ammonia for cyclooligo-β-(1→6)-D-glucosamines) was observed along with other processes including the unknown skeletal rearrangement. A primary fragmentation of the negatively charged ions (deprotonated molecules) differed from that of the positively charged ones.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excitonic Energy Landscape of the Y16F Mutant of the Chlorobium tepidum Fenna–Matthews–Olson (FMO) Complex: High Resolution Spectroscopic and Modeling Studies

We report high-resolution (low-temperature) absorption, emission, and nonresonant/resonant hole-burned (HB) spectra and results of excitonic calculations using a non-Markovian reduced density matrix theory (with an improved algorithm for parameter optimization in heterogeneous samples) obtained for the Y16F mutant of the Fenna–Matthews–Olson (FMO) trimer from the green sulfur bacterium Chlorobium tepidum. We show that the Y16F mutant is a mixture of FMO complexes with three independent low-energy traps (located near 817, 821, and 826 nm), in agreement with measured composite emission and HB spectra. Two of these traps belong to mutated FMO subpopulations characterized by significantly modified low-energy excitonic states. Hamiltonians for the two major subpopulations (Sub 821 and Sub 817 ) provide new insight into extensive changes induced by the single-point mutation in the vicinity of BChl 3 (where tyrosine Y16 was replaced with phenylalanine F16). The average decay time(s) from the higher exciton state(s) in the Y16F mutant depends on frequency and occurs on a picosecond time scale.

59 BASIC BIOLOGICAL SCIENCES↗

The study of oxygen molecules on Pt (111) surface with high resolution x-ray photoemission spectroscopy

By using high resolution x-ray photoelectron spectroscopy, we show that inelastic scattering of photoelectron at low temperature (30-50 K) generates two kinds of oxygen species on Pt (111) surface. Intense synchrotron radiation source dissociates oxygen molecules into chemisorbed atomic oxygen and induces the formation of PtO on the surface. Estimated coverage of dissociated atomic oxygen is 0.5 ML, suggesting possible formation of p(2x1) surface structure, while PtO coverage shows saturation coverage of 0.5 ML. Molecular oxygen dosed at 30 K undergoes thermally activated transition from physisorbed to chemisorbed state at around 40 K.

36 MATERIALS SCIENCE↗

ELLERMAN BOMBS AT HIGH RESOLUTION. I. MORPHOLOGICAL EVIDENCE FOR PHOTOSPHERIC RECONNECTION

High-resolution imaging-spectroscopy movies of solar active region NOAA 10998 obtained with the Crisp Imaging Spectropolarimeter at the Swedish 1-m Solar Telescope show very bright, rapidly flickering, flame-like features that appear intermittently in the wings of the Balmer H{alpha} line in a region with moat flows and likely some flux emergence. They show up at regular H{alpha} blue-wing bright points that outline the magnetic network, but flare upward with much larger brightness and distinct 'jet' morphology seen from aside in the limbward view of these movies. We classify these features as Ellerman bombs and present a morphological study of their appearance at the unprecedented spatial, temporal, and spectral resolution of these observations. The bombs appear along the magnetic network with footpoint extents up to 900 km. They show apparent travel away from the spot along the pre-existing network at speeds of about 1 km s{sup -1}. The bombs flare repetitively with much rapid variation at timescales of seconds only, in the form of upward jet-shaped brightness features. These reach heights of 600-1200 km and tend to show blueshifts; some show bi-directional Doppler signature and some seem accompanied with an H{alpha} surge. They are not seen in the core of H{alpha} due to shielding by overlying chromospheric fibrils. The network where they originate has normal properties. The morphology of these jets strongly supports deep-seated photospheric reconnection of emergent or moat-driven magnetic flux with pre-existing strong vertical network fields as the mechanism underlying the Ellerman bomb phenomenon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plant respirometer enables high resolution of oxygen consumption rates

Plant respirometer permits high resolution of relatively small changes in the rate of oxygen consumed by plant organisms undergoing oxidative metabolism in a nonphotosynthetic state. The two stage supply and monitoring system operates by a differential pressure transducer and provides a calibrated output by digital or analog signals.

Foster, D. L.↗