Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Automated defect analysis in electron microscopic images

Electron microscopy and defect analysis are a cornerstone of materials science, as they offer detailed insights on the microstructure and performance of a wide range of materials and material systems. Building a robust and flexible platform for automated defect recognition and classification in electron microscopy will result in the completion of analysis orders of magnitude faster after images are recorded, or even online during image acquisition. Automated analysis has the potential to be significantly more efficient, accurate, and repeatable than human analysis, and it can scale with the increasingly important methods of automated data generation. Herein, an automated recognition tool is developed based on a computer vison–based approach; it sequentially applies a cascade object detector, convolutional neural network, and local image analysis methods. We demonstrate that the automated tool performs as well as or better than manual human detection in terms of recall and precision and achieves quantitative image/defect analysis metrics close to the human average. The proposed approach works for images of varying contrast, brightness, and magnification. Furthermore, these promising results suggest that this and similar approaches are worth exploring for detecting multiple defect types and have the potential to locate, classify, and measure quantitative features for a range of defect types, materials, and electron microscopic techniques.

47 OTHER INSTRUMENTATION↗

Physiological Imaging-Defined, Response-Driven Subvolumes of a Tumor

Purpose: To develop an image analysis framework to delineate the physiological imaging-defined subvolumes of a tumor in relating to treatment response and outcome. Methods and Materials: Our proposed approach delineates the subvolumes of a tumor based on its heterogeneous distributions of physiological imaging parameters. The method assigns each voxel a probabilistic membership function belonging to the physiological parameter classes defined in a sample of tumors, and then calculates the related subvolumes in each tumor. We applied our approach to regional cerebral blood volume (rCBV) and Gd-DTPA transfer constant (K{sup trans}) images of patients who had brain metastases and were treated by whole-brain radiation therapy (WBRT). A total of 45 lesions were included in the analysis. Changes in the rCBV (or K{sup trans})–defined subvolumes of the tumors from pre-RT to 2 weeks after the start of WBRT (2W) were evaluated for differentiation of responsive, stable, and progressive tumors using the Mann-Whitney U test. Performance of the newly developed metrics for predicting tumor response to WBRT was evaluated by receiver operating characteristic (ROC) curve analysis. Results: The percentage decrease in the high-CBV-defined subvolumes of the tumors from pre-RT to 2W was significantly greater in the group of responsive tumors than in the group of stable and progressive tumors (P<.007). The change in the high-CBV-defined subvolumes of the tumors from pre-RT to 2W was a predictor for post-RT response significantly better than change in the gross tumor volume observed during the same time interval (P=.012), suggesting that the physiological change occurs before the volumetric change. Also, K{sup trans} did not add significant discriminatory information for assessing response with respect to rCBV. Conclusion: The physiological imaging-defined subvolumes of the tumors delineated by our method could be candidates for boost target, for which further development and evaluation is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

REMODEL: Rethinking Deep CNN Models to Detect and Count on a NeuroSynaptic System

In this work, we perform analysis of detection and counting of cars using a low-power IBM TrueNorth Neurosynaptic System. For our evaluation we looked at a publicly-available dataset that has overhead imagery of cars with context present in the image. The trained neural network for image analysis was deployed on the NS16e system using IBM's EEDN training framework. Through multiple experiments we identify the architectural bottlenecks present in TrueNorth system that does not let us deploy large neural network structures. Following these experiments we propose changes to CNN model to circumvent these architectural bottlenecks. The results of these evaluations have been compared with caffe-based implementations of standard neural networks that were deployed on a Titan-X GPU. Results showed that TrueNorth can detect cars from the dataset with 97.60% accuracy and can be used to accurately count the number of cars in the image with 69.04% accuracy. The car detection accuracy and car count (–/+ 2 error margin) accuracy are comparable to high-precision neural networks like AlexNet, GoogLeNet, and ResCeption, but show a manifold improvement in power consumption.

97 MATHEMATICS AND COMPUTING↗

Manual versus digital Landsat analysis for delineating river flooding

It has been found that flood boundary information derived from Landsat images, acquired at different flood stages, could be used to develop an empirical model for estimating the extent of flooding on the basis of in situ measurements of river discharge. An investigation was undertaken to determine whether improved results might have been obtained through digital image analysis or by including other Landsat spectral bands. The study area encompasses a highly flood-prone reach of the Black River in Lewis County, NY. It was found that visual analysis of aerial photographs and a Landsat band 7 image gave similar results. Visual and digital analysis of Landsat band 7 data gave similar results, and digital analysis of Landsat band 7 data gave results which were at least as good as digital analysis of combinations of spectral bands.

Philipson, W. R.↗

Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. Conclusions: The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.

60 APPLIED LIFE SCIENCES↗

Synthetic Promoter Screening Using Poplar Mesophyll Protoplast Transformation

Plant protoplasts are useful to study both transcriptional regulation and protein subcellular localization in rapid screens. Protoplast transformation can be used in automated platforms for design-build-test cycles of plant promoters, including synthetic promoters. A notable application of protoplasts comes from recent successes in dissecting synthetic promoter activity with poplar mesophyll protoplasts. For this purpose, we constructed plasmids with TurboGFP driven by a synthetic promoter together with TurboRFP constitutively controlled by a 35S promoter, to monitor transformation efficiency, allowing versatile screening of high numbers of cells by monitoring green fluorescent protein expression in transformed protoplasts. Herein, we introduce a protocol for poplar mesophyll protoplast isolation followed by protoplast transformation and image analysis for the selection of valuable synthetic promoters.

59 BASIC BIOLOGICAL SCIENCES↗

Inferring morphology and strength of magnetic fields from proton radiographs

Proton radiography is an important diagnostic method for laser plasma experiments and is particularly important in the analysis of magnetized plasmas. The theory of radiographic image analysis has heretofore only permitted somewhat limited analysis of the radiographs of such plasmas. We furnish here a theory that remedies this deficiency. We show that to linear order in magnetic field gradients, proton radiographs are projection images of the MHD current along the proton trajectories. We demonstrate that in the linear regime (i.e., the small image contrast regime), the full structure of the projected perpendicular magnetic field can be reconstructed by solving a steady-state inhomogeneous 2-dimensional diffusion equation sourced by the radiograph fluence contrast data. Here, we explore the validity of the scheme with increasing image contrast, as well as limitations of the inversion method due to the Poisson noise, discretization errors, radiograph edge effects, and obstruction by laser target structures. We also provide a separate analysis that is suited to the inference of isotropic-homogeneous magnetic turbulence spectra. Finally, we discuss extension of these results to the nonlinear regime (i.e., the order unity image contrast regime).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct evidence of atomic-scale structural fluctuations in catalyst nanoparticles

Rational catalyst design requires an atomic scale mechanistic understanding of the chemical pathways involved in the catalytic process. A heterogeneous catalyst typically works by adsorbing reactants onto its surface, where the energies for specific bonds to dissociate and/or combine with other species (to form desired intermediate or final products) are lower. Here, using the catalytic growth of single-walled carbon nanotubes (SWCNTs) as a prototype reaction, we show that the chemical pathway may in-fact involve the entire catalyst particle, and can proceed via the fluctuations in the formation and decomposition of metastable phases in the particle interior. We record in situ and at atomic resolution, the dynamic phase transformations occurring in a Cobalt catalyst nanoparticle during SWCNT growth, using a state-of-the-art environmental transmission electron microscope (ETEM). The fluctuations in catalyst carbon content are quantified by the automated, atomic-scale structural analysis of the time-resolved ETEM images and correlated with the SWCNT growth rate. We find the fluctuations in the carbon concentration in the catalyst nanoparticle and the fluctuations in nanotube growth rates to be of complementary character. These findings are successfully explained by reactive molecular dynamics (RMD) simulations that track the spatial and temporal evolution of the distribution of carbon atoms within and on the surface of the catalyst particle. We anticipate that our approach combining real-time, atomic-resolution image analysis and molecular dynamics simulations will facilitate catalyst design, improving reaction efficiencies and selectivity towards the growth of desired structure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An image classification deep-learning algorithm for shrapnel detection from ultrasound images

Ultrasound imaging is essential for non-invasively diagnosing injuries where advanced diagnostics may not be possible. However, image interpretation remains a challenge as proper expertise may not be available. In response, artificial intelligence algorithms are being investigated to automate image analysis and diagnosis. Here, we highlight an image classification convolutional neural network for detecting shrapnel in ultrasound images. As an initial application, different shrapnel types and sizes were embedded first in a tissue mimicking phantom and then in swine thigh tissue. The algorithm architecture was optimized stepwise by minimizing validation loss and maximizing F1 score. The final algorithm design trained on tissue phantom image sets had an F1 score of 0.95 and an area under the ROC curve of 0.95. It maintained higher than a 90% accuracy for each of 8 shrapnel types. When trained only on swine image sets, the optimized algorithm format had even higher metrics: F1 and area under the ROC curve of 0.99. Overall, the algorithm developed resulted in strong classification accuracy for both the tissue phantom and animal tissue. This framework can be applied to other trauma relevant imaging applications such as internal bleeding to further simplify trauma medicine when resources and image interpretation are scarce.

59 BASIC BIOLOGICAL SCIENCES↗

Morphology of Nano and Micro Fiber Structures in Ultrafine Particles Filtration

Selected procedures permitting to prepare homogeneous nanofibre structures of the desired morphology by employing a suitable combination of variables during the electrospinning process are presented. A comparison (at the same pressure drop) was made of filtration capabilities of planar polyurethane nanostructures formed exclusively by nanofibres, space polycarbonate nanostructures having bead spacers, structures formed by a combination of polymethyl methacrylate micro- and nanofibres and polypropylene meltblown microstructures, through which ultrafine particles of ammonium sulphate 20-400 nm in size were filtered. The structures studied were described using a new digital image analysis technique based on black and white images obtained by scanning electron microscopy. More voluminous structures modified with distance microspheres and having a greater thickness and mass per square area of the material, i.e. structures possessing better mechanical properties, demanded so much in nanostructures, enable preparation of filters having approximately the same free volume fraction as flat nanofibre filters but an increased effective fibre surface area, changed pore size morphology and, consequently, a higher filter quality.

36 MATERIALS SCIENCE↗

Implementation and characterization of a 320-slice volumetric CT scanner for simulation in radiation oncology

Purpose: Effective target definition and broad employment of treatment response assessment with dynamic contrast-enhanced CT in radiation oncology requires increased speed and coverage for use within a single bolus injection. To this end, a novel volumetric CT scanner (Aquilion One, Toshiba, Tochigi Pref., Japan) has been installed at the Princess Margaret Hospital for implementation into routine CT simulation. This technology offers great advantages for anatomical and functional imaging in both scan speed and coverage. The aim of this work is to investigate the system's imaging performance and quality as well as CT quantification accuracy which is important for radiotherapy dose calculations. Methods: The 320-slice CT scanner uses a 160 mm wide-area (2D) solid-state detector design which provides the possibility to acquire a volumetric axial length of 160 mm without moving the CT couch. This is referred to as ''volume'' and can be scanned with a rotation speed of 0.35-3 s. The scanner can also be used as a 64-slice CT scanner and perform conventional (axial) and helical acquisitions with collimation ranges of 1-32 and 16-32 mm, respectively. Commissioning was performed according to AAPM Reports TG 66 and 39 for both helical and volumetric imaging. Defrise and other cone-beam image analysis tests were performed. Results: Overall, the imaging spatial resolution and geometric efficiency (GE) were found to be very good (>10 lp/mm, <1 mm spatial integrity and GE{sub 160mm}=85%) and within the AAPM guidelines as well as IEC recommendations. Although there is evidence of some cone-beam artifacts when scanning the Defrise phantom, image quality was found to be good and sufficient for treatment planning (soft tissue noise <10 HU). Measurements of CT number stability and contrast-to-noise values across the volume indicate clinically acceptable scan accuracy even at the field edge. Conclusions: Initial experience with this exciting new technology confirms its accuracy for routine CT simulation within radiation oncology and allows for future investigations into specialized dynamic volumetric imaging applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mapping Benthic Habitat Conditions and Seafloor Deposits using Sediment Profile Imaging and a Semiautomated Image Processing System

Objectives/Scope: Sediment profile imaging (SPI) technology characterizes in situ physical, geochemical, and biological seafloor features. SPI was required by Mexico’s Agency for Safety, Energy, and Environment in 2017 for environmental baseline surveys (EBS) of oil lease blocks in the southern Gulf of Mexico. Because of its ability to provide information on benthic community health and the distribution of very thin (down to the centimeter scale) layers of deposited materials, SPI technology is highly effective for mapping drill cuttings or drilling muds released around wellheads during exploration or production and documenting their ecological impacts. SPI technology has not been widely used in the oil and gas industry for EBS or other monitoring activities. A primary objective of this work is to improve the transparency and consistency of the SPI data generation and data management process. Methods, Procedures, Process: The SPI camera works like an inverted periscope and obtains an undisturbed 21x15-cm cross-sectional image of the upper sediment column. The camera is internally powered and can be deployed rapidly from a standard winch in depths to 4,000 m. Many stations can be sampled in a single day by “pogo-sticking” across a survey area. Sediment grain size, penetration depth, surface boundary roughness, natural and anthropogenic depositional layers, depth of the oxidized surface sediment layer, maximum biogenic mixing depth, and infaunal successional stage can be directly measured at sea or immediately following the cruise. Final SPI data sets can be provided within a few weeks of the survey. Results, Observations, Conclusions: Details on the features measured in SPI images and the underlying interpretive paradigms are presented. To standardize the SPI data generation process, Integral Consulting Inc. has developed 1) a semiautomated image analysis platform, and 2) a SPI data-specific database architecture that allows both numerical and non-numerical metrics to be incorporated into a standard database structure. An integrated, software-based SPI analysis platform has been developed that imports image files and metadata and provides a graphical user interface. The software automatically stores the data, which can then be reviewed for quality assurance, plotted, statistically analyzed, and mapped or exported to other platforms (e.g., Esri ArcGIS©) for further evaluation. Image processing algorithms have been developed using a combination of open-source and commercially available software packages (e.g., MATLAB® and OpenCV) to automatically quantify key parameters. Novel/Additive Information: SPI technology’s underutilization in the oil and gas industry may be in part due to a lack of standardization in the measurement of basic features in SPI images. A primary objective of this work is to develop a streamlined, standardized, and transparent process for generating and managing SPI data.

02 PETROLEUM↗

Application of an electronic image analyzer to dimensional measurements from neutron radiographs

Means of obtaining improved dimensional measurements from neutron radiographs of nuclear fuel elements are discussed. The use of video-electronic image analysis relative to edge definition in radiographic images is described. Based on this study, an edge definition criterion is proposed for overcoming image unsharpness effects in taking accurate diametral measurements from radiographs. An electronic density slicing method for automatic edge definition is described. Results of measurements made with video micrometry are compared with scanning microdensitometer and micrometric physical measurements. An image quality indicator for estimating photographic and geometric unsharpness is described.

Vary, A.↗

Tracking Visible Targets Automatically

Report summarizes techniques for automatic pointing of scientific instruments by reference to visible targets. Applications foreseen in industrial robotics. Measurement done by image analysis based on gradient edge location, image-centroid location and/or outline matching.

Armstrong, R. W.↗

Atomization and combustion performance of antimisting kerosene and jet fuel

Combustion performance of antimisting kerosene (AMK) containing FM-9 polymer was investigated at various levels of degradation (restoration of AMK for normal use in a gas turbine engine). To establish the relationship of degradation and atomization to performance in an aircraft gas turbine combustor, sprays formed by the nozzle of a JT8-D combustor with Jet A and AMK at 1 atmosphere (atm) (14.1 lb/square in absolute) pressure and 22 C at several degradation levels were analyzed. A new spray characterization technique based on digital image analysis of high resolution, wide field spray images formed under pulsed ruby laser sheet illumination was developed. Combustion tests were performed for these fuels in a JT8-D single can combustor facility to measure combustion efficiency and the lean extinction limit. Correlation of combustion performance under simulated engine operating conditions with nozzle spray Sauter mean diameter (SMD) measured at 1 atm and 22 C were observed. Fuel spray SMD and hence the combustion efficiency are strongly influenced by fuel degradation level. Use of even the most highly degraded AMK tested (filter ratio = 1.2) resulted in an increase in fuel consumption of 0.08% to 0.20% at engine cruise conditions.

Fleeter, R.↗

SOT: A rapid prototype using TAE windows

The development of the window interface extension feature of the Transportable Applications Executive (TAE) is discussed. This feature is being used to prototype a space station payload interface in order to demonstrate and assess the benefits of using windows on a bit mapped display and also to convey the concept of telescience, the control and operation of space station payloads from remote sites. The prototype version of the TAE with windows operates on a DEC VAXstation 100. This workstation has a high resolution 19 inch bit mapped display, a keyboard and a three-button mouse. The VAXstation 100 is not a stand-alone workstation, but is controlled by software executing on a VAX/8600. A short scenario was developed utilizing the Solar Optical Telescope (SOT) as an example payload. In the scenario the end-user station includes the VAXstation 100 plus an image analysis terminal used to display the CCD images. The layout and use of the prototype elements, i.e., the root menu, payload status window, and target acquisition menu is described.

Stephens, Mark↗

Recent Advances in Soft Matter Characterization Capabilities Developed at NASA GRC for Lunar Exploration: Differential Dynamic Microscopy to Spectroscopy to Computer Vision

In 1991, famous French scientist Pierre-Gilles de Genes was awarded Nobel prize for his impactful research in soft matter, more specifically polymers. He is defined as the founding father of soft matter. In his Nobel lecture (https://www.nobelprize.org/uploads/2018/06/gennes-lecture.pdf ) he described soft matter aka complex fluids as materials with two primary features – (a) complexity and (b) flexibility. The sub-categories of soft matter (e.g.- granular materials, polymers, foams, colloids etc.) are defined on the basis of Pierre-Gilles de Gennes’ definition. At NASA GRC, we are pushing the boundaries for fundamental study of soft matter on Lunar Surface. With regard to Lunar surface science, we are focusing on developing capabilities pertaining to granular materials and bio-soft/active matter to facilitate future efforts in ISRU and bio-ISRU capabilities. In order to achieve fundamental goals of soft matter research within the limitations of Lunar environment, the scientific capabilities need to be small, flexible, modular, off the shelf and the focus needs to be more on developing an interdisciplinary capability that leverages the recent growth in AI/ML and Computer Vision to augment our understanding of fundamental science. This strategy would allow us to reduce our resource requirement during launch, installation, and occupied real estate footprint on Lunar surface In this talk, we will go over 3 different capabilities that we have developed in house and in close collaboration – (a) Differential Dynamic Microscopy (DDM), (b) Portable In-situ Chemical Spectroscopy (PICS) and (c) Computer Vision Enabled Observation. At very high level, Differential Dynamic Microscopy (DDM) allows us to study the structure-property-process relation (microrheology) of bio-soft/active matter using optical microscope and improved image analysis capabilities. PICS uses AI/ML-based advanced signal deconvolution and analysis technique that can work with existing portable spectroscopy tools to perform materials analysis (e.g.- granular materials and bio-soft/active matter) inspection on the go. Finally, computer vision enabled analysis allows us to use simple camera images for 3D reconstruction of experimental process and tracking of objects of interest in an experiment. We expect that this detailed process will allow us reach a thorough understanding of soft matter in Lunar environment. The capabilities developed by us will help to validate and establish fundamental understanding in Lunar environment. This will, in turn, allow us to guide future space exploration missions and expand the knowledge base of the scientific and engineering communities.

Suman Sinha Ray↗