Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Cast Glance Near Infrared Imaging Observations of the Space Shuttle During Hypersonic Re-Entry

High resolution calibrated infrared imagery of the Space Shuttle was obtained during hypervelocity atmospheric entries of the STS-119, STS-125 and STS128 missions and has provided information on the distribution of surface temperature and the state of the airflow over the windward surface of the Orbiter during descent. This data collect was initiated by NASA s Hypersonic Thermodynamic Infrared Measurements (HYTHIRM) team and incorporated the use of air- and land-based optical assets to image the Shuttle during atmospheric re-entry. The HYTHIRM objective is to develop and implement a set of mission planning tools designed to establish confidence in the ability of an existing optical asset to reliably acquire, track and return global quantitative surface temperatures of the Shuttle during entry. On Space Shuttle Discovery s STS-119 mission, NASA flew a specially modified thermal protection system tile and instrumentation package to monitor heating effects from boundary layer transition during re-entry. On STS-119, the windward airflow on the port wing was deliberately disrupted by a four-inch wide and quarter-inch tall protuberance built into the modified tile. In coordination with this flight experiment, a US Navy NP-3D Orion aircraft was flown 28 nautical miles below Discovery and remotely monitored surface temperature of the Orbiter at Mach 8.4 using a long-range infrared optical package referred to as Cast Glance. Approximately two months later, the same Navy Cast Glance aircraft successfully monitored the surface temperatures of the Orbiter Atlantis traveling at approximately Mach 14.3 during its return from the successful Hubble repair mission. In contrast to Discovery, Atlantis was not part of the Boundary Layer Transition (BLT) flight experiment, thus the vehicle was not configured with a protuberance on the port wing. In September 2009, Cast Glance was again successful in capturing infrared imagery and monitoring the surface temperatures on Discovery s next flight, STS-128. Again, NASA flew a specially modified thermal protection system tile and instrumentation package to monitor heating effects from boundary layer transition during re-entry. During this mission, Cast Glance was able to image laminar and turbulent flow phenomenology optimizing data collection for Mach 14.7. The purpose of this paper is to describe key elements associated with STS-119/125/128 mission planning and execution from the perspective of the Cast Glance flight crew that obtained the imagery. The paper will emphasize a human element of experience, expertise and adaptability seamlessly coupled with Cast Glance system and sensor technology required to manually collect the required imagery. Specific topics will include a near infrared (NIR) camera upgrade that was implemented just prior to the missions, how pre-flight radiance modeling was utilized to optimize the IR sensor configuration, communications, the development of aircraft test support positions based upon Shuttle trajectory information, support to contingencies such as Shuttle one orbit wave-offs/west coast diversions and then the Cast Glance perspective during an actual Shuttle imaging mission.

Tack, Steve↗

Field Exploration and Life Detection Sampling for Planetary Analogue Research (FELDSPAR): Variability and Correlation in Biomarker and Mineralogy Measurements from Icelandic Mars Analogues

In situ exploration of planetary environments allows biochemical analysis of sub-centimeter-scale samples; however, landing sites are selected a priori based on measurable meter- to kilometer-scale geological features. Optimizing life detection mission science return requires both understanding the expected biomarker distributions across sample sites at different scales and efficiently using first-stage in situ geochemical instruments to justify later-stage biological or chemical analysis. Icelandic volcanic regions have an extensive history as Mars analogue sites due to desiccation, low nutrient availability, and temperature extremes, in addition to the advantages of geological youth and isolation from anthropogenic contamination. Many Icelandic analogue sites are also rugged and remote enough to create the same type of instrumentation and sampling constraints typically faced by robotic exploration.

Planetary↗

NASA Langley Aerothermodynamics Laboratory: Hypersonic Testing Capabilities

A description of the NASA Langley Research Center’s Langley Aerothermodynamics Laboratory (LAL) will be presented in the paper, along with descriptions and details of the facility test techniques and recent upgrades. The LAL consists of three hypersonic blow-down wind tunnels covering Mach numbers of 6 and 10 and unit Reynolds number ranges of 0.5 to 8.3 million per foot as well as a 60-ft Vacuum Sphere Test Chamber. LAL facilities are used to study and define the aerodynamic performance and aeroheating characteristics of flight vehicle concepts. Data collected in the facilities have been used for design and optimization, anchoring computational predictions, generation of aerodynamic databases and design of Thermal Protection Systems. Over the years modifications and enhancements have been made to the facility hardware and instrumentation to increase efficiency, data quality, capabilities and reliability to better meet the programmatic requirements. Recent utilization information illustrates the need for the capabilities associated with these facilities. Recent test programs include the Space Shuttle Program, Crew Exploration Vehicle/Orion/Multi-Purpose Crew Vehicle, Hypersonic International Flight Research Experimentation (HIFiRE), Mars Science Laboratory, Hypersonic Inflatable Aerodynamic Decelerator System (HIADS) and X-51 among others and usage has been split between NASA, Commercial Crew, Department of Defense and private company programs. Plans for future improvements to the facility infrastructure and instrumentation will also be presented.

Karen Berger↗

DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Specification of Optical Bandpass Filters for Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS)

Advanced optical bandpass filters for the Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS) have been developed on a filter-by-filter basis through detailed studies which take into account the instrument's science goals, available optical filter fabrication technology, and developments in ACS's charge-coupled-device (CCD) detector technology. These filters include a subset of filters for the Sloan Digital Sky Survey (SDSS) which are optimized for astronomical photometry using today's charge-coupled-devices (CCD's). In order for ACS to be truly advanced, these filters must push the state-of-the-art in performance in a number of key areas at the same time. Important requirements for these filters include outstanding transmitted wavefront, high transmittance, uniform transmittance across each filter, spectrally structure-free bandpasses, exceptionally high out of band rejection, a high degree of parfocality, and immunity to environmental degradation. These constitute a very stringent set of requirements indeed, especially for filters which are up to 90 mm in diameter. The highly successful paradigm in which final specifications for flight filters were derived through interaction amongst the ACS Science Team, the instrument designer, the lead optical engineer, and the filter designer and vendor is described. Examples of iterative design trade studies carried out in the context of science needs and budgetary and schedule constraints are presented. An overview of the final design specifications for the ACS bandpass and ramp filters is also presented.

Leviton, Douglas B.↗

High-Power Targetry for Muon Production

The production of high-intensity muon beams is crucial for advancing particle and accelerator physics, both now and in the future. Achieving these high-intensity goals requires overcoming significant challenges in high-power targetry. Here, we will outline the key challenges and explore the selection of target materials, focusing on muon production and susceptibility to radiation damage -- key factors for optimal target designs.

43 PARTICLE ACCELERATORS↗

Smokeless Chimney using Smoke Opacity as a Combustion Control Parameter (CRADA Final Report)

If operated poorly, wood burning heaters can produce large amounts of particulate matter (PM). Although several instruments are available to monitor PM, most require dilution air and are unable to sample directly from a flue due to the high PM concentrations and temperatures. Opacity sensors can measure color, opacity and smoke density from wood heater stacks. They operate by transmitting a light beam through the emission source and measuring the amount of light intensity lost (opacity) and light not reflected (color). Although opacity sensors are used in several areas, none have been thoroughly evaluated or optimized for measuring smoke from wood heaters.

47 OTHER INSTRUMENTATION↗

Optimizing the Model of the Viking-400 UAS

This project intends to update and redesign imperfections in the scanned 3D CAD model of the Viking 400 aircraft. This aircraft, similar to the Sierra-B UAS, will carry payloads of scientific instruments for research purposes. The goals of this project are to modify the current scanned model such that it better represents the physical qualities of the aircraft, as well as creating the features that are missing from the model. As the model was imported from a different software, many of the critical surfaces did not accurately reflect the actual aircraft. Those parts of the model were redesigned entirely so that they can be edited for future use, as well as correctly representing the aircraft as it is now. Additionally, parts of the aircraft that did not appear in the scanned model were designed and added to the new model. In order to prioritize ease of use for future missions, the model has been reorganized in a logical fashion that enables modification of specific parts of the aircraft. The organization of this model imitates the drawing tree of the Sierra-B, with the intention of maintaining a functional system of redesign, analysis, and implementation. Ultimately, this project will be a catalyst for making Viking 400 into a functional aircraft and increasing scientific research in airborne vehicles.

Wandrocke, Evan W. J.↗

A convergence metric for counting statistics in time-resolved small angle neutron scattering

Here, this work introduces a model-independent, dimensionless metric for predicting optimal measurement duration in time-resolved small-angle neutron scattering using early-time data. Built on a Gaussian process regression framework, the method reconstructs scattering profiles with quantified uncertainty, even from sparse or noisy measurements. Demonstrated on the EQ-SANS instrument at the Spallation Neutron Source, the approach generalizes to general SANS instruments with a two-dimensional detector. A key result is the discovery of a dimensionless convergence metric revealing a universal power-law scaling in profile evolution across soft matter systems. When time is normalized by a system-specific characteristic time t*, the variation in inferred profiles collapses onto a single curve with an exponent between −2 and −1. This trend emerges within the first ten time steps, enabling early prediction of measurement sufficiency. The method supports real-time experimental optimization and is especially valuable for maximizing efficiency in low-flux environments such as compact accelerator-based neutron sources.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, aLIBS system was designed and assembled at the NASA Langley Research Center (LaRC) to enable detection of ultra low concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization ofCFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity

Rodolfo I. Ledesma↗

Particle detection by a light-scattering technique

Instrument measures concentration of small particles in aqueous medium in terms of amount of light scattered and degree to which light transmission is attenuated. Sensitivity to small particles is optimized because both scattered and transmitted illumination levels are detected by photodiodes.

Kormanyos, S.↗

A sleep diary and questionnaire study of naturally short sleepers

Whereas most people require more than 6 h of sleep to feel well rested, there appears to be a group of people who can function well on between 3 and 6 h of sleep. The aims of the present study were to compare 12 naturally short (3-6 h) sleepers (9 males 3 females, mean age 39.6 years, SD age 10.1 years) recruited by a media publicity campaign with age, gender and chronotype matched medium length (7-8.5 h) sleepers on various measures. Measurement instruments included diaries and questionnaires to assess sleep duration and timing, as well as questionnaire assessments of sleep pathology, morningness-eveningness, extroversion, neuroticism, pathological daytime sleepiness, subclinical hypomania, optimism, depressive symptoms, exercise, and work habits. Few measures showed reliable differences between naturally short sleepers and controls except the obvious ones related to sleep duration. There was, however, some evidence for subclinical hypomanic symptoms in naturally short sleepers.

NASA Discipline Regulatory Physiology↗

Improved Nuclear Reactor and Shield Mass Model for Space Applications

New technologies are being developed to explore the distant reaches of the solar system. Beyond Mars, solar energy is inadequate to power advanced scientific instruments. One technology that can meet the energy requirements is the space nuclear reactor. The nuclear reactor is used as a heat source for which a heat-to-electricity conversion system is needed. Examples of such conversion systems are the Brayton, Rankine, and Stirling cycles. Since launch cost is proportional to the amount of mass to lift, mass is always a concern in designing spacecraft. Estimations of system masses are an important part in determining the feasibility of a design. I worked under Michael Barrett in the Thermal Energy Conversion Branch of the Power & Electric Propulsion Division. An in-house Closed Cycle Engine Program (CCEP) is used for the design and performance analysis of closed-Brayton-cycle energy conversion systems for space applications. This program also calculates the system mass including the heat source. CCEP uses the subroutine RSMASS, which has been updated to RSMASS-D, to estimate the mass of the reactor. RSMASS was developed in 1986 at Sandia National Laboratories to quickly estimate the mass of multi-megawatt nuclear reactors for space applications. In response to an emphasis for lower power reactors, RSMASS-D was developed in 1997 and is based off of the SP-100 liquid metal cooled reactor. The subroutine calculates the mass of reactor components such as the safety systems, instrumentation and control, radiation shield, structure, reflector, and core. The major improvements in RSMASS-D are that it uses higher fidelity calculations, is easier to use, and automatically optimizes the systems mass. RSMASS-D is accurate within 15% of actual data while RSMASS is only accurate within 50%. My goal this summer was to learn FORTRAN 77 programming language and update the CCEP program with the RSMASS-D model.

Robb, Kevin↗

Satellite Data Simulator Unit: A Multisensor, Multispectral Satellite Simulator Package

Several multisensor simulator packages are being developed by different research groups across the world. Such simulator packages [e.g., COSP , CRTM, ECSIM, RTTO, ISSARS (under development), and SDSU (this article), among others] share overall aims, although some are targeted more on particular satellite programs or specific applications (for research purposes or for operational use) than others. The SDSU or Satellite Data Simulator Unit is a general-purpose simulator composed of Fortran 90 codes and applicable to spaceborne microwave radiometer, radar, and visible/infrared imagers including, but not limited to, the sensors listed in a table. That shows satellite programs particularly suitable for multisensor data analysis: some are single satellite missions carrying two or more instruments, while others are constellations of satellites flying in formation. The TRMM and A-Train are ongoing satellite missions carrying diverse sensors that observe clouds and precipitation, and will be continued or augmented within the decade to come by future multisensor missions such as the GPM and Earth-CARE. The ultimate goals of these present and proposed satellite programs are not restricted to clouds and precipitation but are to better understand their interactions with atmospheric dynamics/chemistry and feedback to climate. The SDSU's applicability is not technically limited to hydrometeor measurements either, but may be extended to air temperature and humidity observations by tuning the SDSU to sounding channels. As such, the SDSU and other multisensor simulators would potentially contribute to a broad area of climate and atmospheric sciences. The SDSU is not optimized to any particular orbital geometry of satellites. The SDSU is applicable not only to low-Earth orbiting platforms as listed in Table 1, but also to geostationary meteorological satellites. Although no geosynchronous satellite carries microwave instruments at present or in the near future, the SDSU would be useful for future geostationary satellites with a microwave radiometer and/or a radar aboard, which could become more feasible as engineering challenges are met. In this short article, the SDSU algorithm architecture and potential applications are reviewed in brief.

Masunaga, Hirohiko↗

The SWIFT Gamma-Ray Burst X-Ray Telescope

The Swift Gamma-Ray Burst Explorer is designed to make prompt multi-wavelength observations of Gamma-Ray Bursts and GRB afterglows. The X-ray Telescope enables Swift to determine GRB positions with a few arcseconds accuracy within 100 seconds of the burst onset. The XRT utilizes a mirror set built for JET-X and an XMM-Newton/ EPIC MOS CCD detector to provide a sensitive broad-band (0.2-10 keV) X-ray imager with an effective area of more than 120 sq cm at 1.5 keV, a field of view of 23.6 x 23.6 arcminutes, and an angular resolution of 18 arcseconds (HPD). The detection sensitivity is 2x10(exp 14) erg/sq cm/s in 10(exp 4) seconds. The instrument provides automated source detection and position reporting within 5 seconds of target acquisition. It can also measure the redshifts of GRBs with Iron line emission or other spectral features. The XRT operates in an auto-exposure mode, adjusting the CCD readout mode automatically to optimize the science return as the source intensity fades. The XRT measures spectra and lightcurves of the GRB afterglow beginning about a minute after the burst and follows each burst for days or weeks. We provide an overview of the X-ray Telescope scientific background from which the systems engineering requirements were derived, with specific emphasis on the design and qualification aspects from conception through to launch. We describe the impact on cleanliness and vacuum requirements for the instrument low energy response and to maintain the high sensitivity to the fading signal of the Gamma-ray Bursts.

Hill, J. E.↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, a LIBS system was designed and assembled at NASA Langley Research Center (LaRC) to enable detection of ultralow concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization of CFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is also presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity.

Surface characterization, Carbon fiber reinforced ↗

Multi-Parameter Aerosol Scattering Sensor

This work relates to the development of sensors that measure specific aerosol properties. These properties are in the form of integrated moment distributions, i.e., total surface area, total mass, etc., or mathematical combinations of these moment distributions. Specifically, the innovation involves two fundamental features: a computational tool to design and optimize such sensors and the embodiment of these sensors in actual practice. The measurement of aerosol properties is a problem of general interest. Applications include, but are not limited to, environmental monitoring, assessment of human respiratory health, fire detection, emission characterization and control, and pollutant monitoring. The objectives for sensor development include increased accuracy and/or dynamic range, the inclusion in a single sensor of the ability to measure multiple aerosol properties, and developing an overall physical package that is rugged, compact, and low in power consumption, so as to enable deployment in harsh or confined field applications, and as distributed sensor networks. Existing instruments for this purpose include scattering photometers, direct-reading mass instruments, Beta absorption devices, differential mobility analyzers, and gravitational samplers. The family of sensors reported here is predicated on the interaction of light and matter; specifically, the scattering of light from distributions of aerosol particles. The particular arrangement of the sensor, e.g. the wavelength(s) of incident radiation, the number and location of optical detectors, etc., can be derived so as to optimize the sensor response to aerosol properties of practical interest. A key feature of the design is the potential embodiment as an extremely compact, integrated microsensor package. This is of fundamental importance, as it enables numerous previously inaccessible applications. The embodiment of these sensors is inherently low maintenance and high reliability by design. The novel and unique features include the underlying computational underpinning that allows the optimization for specific applications, and the physical embodiment that affords the construction of a compact, durable, and reliable integrated package. The advantage appears in the form of increased accuracy relative to existing instruments, and the applications enabled by the physical attributes of the resulting configuration

Greenberg, Paul S.↗