Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Used Fuel Cask Identification through Neutron Profile

Currently, most spent fuel is stored near reactors. An interim consolidated fuel storage facility would receive fuel from multiple sites and store it in casks on site for decades. For successful operation of such a facility there is need for a way to restore continuity of knowledge if lost as well as a method that will indicate state of fuel inside the cask. Used nuclear fuel is identifiable by its radiation emission, both gamma and neutron. Neutron emission from fission products, multiplication from remaining fissile material, and the unique distribution of both in each cask produce a unique neutron signature. If two signatures taken at different times do not match, either changes within the fuel content or misidentification of a cask occurred. It was found that identification of cask loadings works well through the profile of emitted neutrons in simulated real casks. Even casks with similar overall neutron emission or average counts around the circumference can be distinguished from each other by analyzing the profile. In conclusion, (1) identification of unaltered casks through neutron signature profile is viable; (2) collecting the profile provides insight to the condition and intactness of the fuel stored inside the cask; and (3) the signature profile is stable over time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to understanding how homes use energy. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, NREL researchers investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. This report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to 10 end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. NREL concludes that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Impact of Operational Strategies and Load Fluctuations on Anion Exchange Membrane Water Electrolyzer Degradation

This study reports on the durability of anion exchange membrane water electrolyzers (AEMWEs) at the cell level in a supporting electrolyte (1 M) and the impact of operational profiles on cell degradation. While constant load shows significant voltage loss, including a current hold at 1 A cm −2 and a potential hold at 2 V, it generally occurs in the first 70 h of testing. These losses are likely due to passivation altering site reactivity and cell kinetics, and are largely recoverable upon load cycling and diagnostics at the end of test. Furthermore, square and triangular-wave cycling do not show cell degradation and indicate that AEMWEs are not vulnerable to load cycling. When operating outside of this potential window (1.45–2 V), cell voltage decay rates markedly increase and the losses are not recoverable. This includes a current density hold at 4.0 A cm −2 with high cell voltages (>2.4 V for test duration) and cycling between 0 and 2 V to simulate start–stop, where more than a 50% loss in current density occurs over 50 h. The findings presented here demonstrate the high durability of AEMWEs, particularly when operating with load fluctuations, and may allow for durability advantages compared to iridium and proton exchange membrane systems.

08 HYDROGEN↗

Controlled Environmental Effects on Creep Test Data of Woven Fabric Webbings for Inflatable Space Modules

eveloping technologies for proposed lunar and Mars space exploration missions. Enhanced habitation sy g studied as potential habitats due to their inherent low mass and small launch volume. One goal of inflatable module research is quantification of the safe-life and end-of-life creep-strain spectrum. Full-scale pressurized inflatable modules are large, costly, and difficult to experimentally study. Therefore, material subcomponents are often studied as an alternative. An experimental thermally controlled long-term creep study of VectranTM webbings for application to inflatable modules is presented. Vectran fibers have high strength and low creep properties. High strength webbing materials are desirable for the load bearing restraint layer of inflatable modules because they are strong, flexible, and lightweight. Characterization of the creep behavior, safe-life, and end-of- life of webbing specimens will help quantify comparable life properties for inflatable modules. Several experimental multiple-year creep studies of webbing specimens in uncontrolled thermal environments have been conducted at NASA Langley Research Center. Experimental data obtained exhibits the classic creep-strain curve due to load, coupled with unique sinusoidal variation due to variation in temperature and humidity over daily and annual time periods. Results also have indicated that specimens fail within a year if the applied load is greater than 50 percent of the rated load. The primary goal of this study is to eliminate thermal effects from the creep data for a group of webbing specimens, and to allow uncontrolled thermal effects to influence the creep data of a second group of webbing specimens. Comparison of both sets of data will define how temperature influences creep data. A unique creep test facility was fabricated to facilitate the generation and comparison of the two sets of data. The facility consists of five creep test stands with an integrated heating and cooling system, and four creep test stands exposed to external environmental or ambient conditions. The facility contains displacement, temperature, humidity, and load sensors. Test specimens consist of one- inch wide, 48-inch long Vectran webbings rated at 12,500 pounds-per-inch. Experimental thermally controlled creep-strain data has been generated for two groups of webbing specimens. Applied load for all test stands was above 9000 lbs and greater than 50 percent of the rated load. Temperatures varied between 58˚F and 83˚F for the four test stands exposed to ambient conditions. Associated creep data exhibited the classic creep- strain profiles. The temperature was set to 72˚F for the five test stands in the controlled temperature environment. Creep data for tests with temperature control also exhibited the classic strain profiles. Data indicated that if the load is greater n thermal effects do not manifest. Therefore, creep tests with loads less than 50 percent of the rated load are planned for in the near future.

Kenner, Winfred S.↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to our understanding of how homes use energy, and we cannot control what we do not understand. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, we have investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. The scope of this report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to ten end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. We conclude that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ascent structural wind loads for the National Space Transportation System (NSTS)

An aerospace vehicle must withstand the design ascent structural load or be within any flight constraint to safely reach orbit. For the NSTS an assessment for flight readiness is made for each mission. This assessment for ascent loads and performance parameters is stated in terms of launch probability derived from samples of Jimsphere wind profiles. For the day of launch operations an allowance is made for the ascent load variability due to the wind profile variability over a 3.5-hour period. This is the current time period required to obtain a Jimsphere measurement and perform a complete load simulation prior to launch time. The load variability is derived from a sample of 3.5-hour Jimsphere wind profile pairs. It is applied as a conditional percentile value given the wind load at 3.5 hours prior to launch time. Probability models are used for these analyses. Application of the univariate, bivariate and conditional forms of the extreme value (Gumbel) probability distribution to the analysis of extreme wind speeds, wind shears and vehicle loads is described.

Smith, O. E.↗

Quantification of storage required for preserving frequency security in wind‐integrated systems

Abstract The penetration of wind power generation into the power grid has been accelerated in recent times due to the aggressive emission targets set by governments and other regulatory authorities. Although wind power has the advantage of being environment‐friendly, wind as a resource is intermittent in nature. In addition, wind power contributes little inertia to the system as most wind turbines are connected to the grid via power electronic converters. These negative aspects of wind power pose serious challenges to the frequency security of power systems as penetration increases. In this work, an approach is proposed where an energy storage system (ESS) is used to mitigate frequency security issues of wind‐integrated systems. ESSs are well equipped to supply virtual inertia to the grid due to their fast‐acting nature, thus replenishing some of the energy storage capability of displaced inertial generation. In this work, a probabilistic approach is proposed to estimate the amount of inertia required by a system to ensure frequency security. Reduction in total system inertia due to the displacement of conventional synchronous generation by wind power generation is considered in this approach, while also taking into account the loss of inertia due to forced outages of conventional units. Monte Carlo simulation is employed for implementing the probabilistic estimation of system inertia. An ESS is then sized appropriately, using the system swing equation, to compensate for the lost inertia. The uncertainty associated with wind energy is modeled into the framework using an autoregressive moving average technique. Effects of increasing the system peak load and changing the wind profile on the expected system inertia are studied to illustrate various factors that might affect system frequency security. The proposed method is validated using the IEEE 39‐bus test system.

17 WIND ENERGY↗

Shock melting and the hcp-bcc phase boundary of Mg under dynamic loading

The high-temperature and high-pressure response of magnesium has been investigated through shock-release experiments performed up to shock melting. The longitudinal and bulk sound speeds of Mg are reported along the Hugoniot from 25 to 56 GPa and used to determine the elastic properties and Grüneisen parameter. The hexagonal close-packed (hcp)–body-centered cubic (bcc) phase transition is marked by a reduction in the determined shear wave speed. Thermal softening is observed to begin between 40 and 44 GPa, with incipient melt at 55.5 GPa, in close agreement with previous diffraction measurements under laser shock loading. Examination of the release profiles showed that two different responses were observed, depending on the peak stress. When plotted in a stress-energy phase diagram, the two responses are observed to form separate lines that intersect the static hcp-bcc phase transition and incipient melt. The results indicate that the hcp-bcc transition occurs on the Hugoniot at 28.4 GPa and place the hcp-bcc-liquid triple point ~20 GPa. In conclusion, a multiphase equation of state is developed which places the melt boundary below the previously reported static measurements.

36 MATERIALS SCIENCE↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Q3 Report for FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment

This report describes the work and activities carried out towards the completion of each of the following milestones in FY25 Q3: 1. Demonstrate workflow for generating self-consistent CESOL plasma profiles + first wall and divertor loading prediction and generate the CAT plasma and neutron loading needed for further engineering analysis. • Benchmark between two first wall heat flux mapping methods, identify importance of various heat flux sources and physics impact of using fully coupled CESOL vs post-analysis evaluation. 2. Generate medium fidelity parametrized CAD. • Generate parametrized CAD components for the CAT example case via either user-defined modules called within the geometry generation or by defeatured/parametrized CAD, including DCLL blanket matched to divertor boundary and magnets. Define materials, labels, and boundary conditions for passing the mesh to CFD tools. 3. Demonstrate multiphysics magnet analysis. • Demonstrate magnet analysis workflow called from the FREDA workflow, and 4. Demonstrate nuclear analysis. • Add model to OpenFOAM and/or other codes possibly including Diablo to account for tritium diffusion in solids.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Q2 Report for FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment

This report describes the work and activities carried out towards the completion of each of the following milestones in FY25 Q2: 1. Demonstrate workflow for generating self-consistent CESOL plasma profiles + first wall and divertor loading prediction and generate the CAT plasma and neutron loading needed for further engineering analysis: $\circ$ Run CESOL with BOUT++/Hermes-3 and immersed boundary condition to directly map to wall: • Run BOUT++/Hermes-3 through the IPS workflow to find radial particle and energy diffusivities to match either the Eich or the physics-based scaling of the SOL heat flux width, and • Expand source of first wall heat flux to include charged particles, neutrals, and radiation from the core+edge. 2. Generate medium fidelity parametrized CAD: $\circ$ Develop the TRACER tool to read an existing CAD, regenerate the geometry based on vertex location and connectivity information, define vertex translation and parameters needed for scaling the CAD, and $\circ$ Utilize the FreeGS code to determine CAT PF coil placement, including minimizing the number of coils, coil current, and electromechanical stresses. 3. Utilize plasma loading for engineering analysis: $\circ$ Couple the plasma loading to input for OpenFOAM and demonstrate initial test of thermal analysis of CAT first wall loading with typical DCLL blanket component cooling boundary conditions. 4. Demonstrate nuclear analysis: $\circ$ Apply initial analysis of tritium transport in DCLL blanket by evaluating spatially resolved tritium generation rates, tritium diffusion and convection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Q1 Report for FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment

This report describes the work and activities carried out towards the completion of each of the following milestones in FY25 Q1: 1. Demonstrate workflow for generating self-consistent CESOL plasma profiles + first wall and divertor loading prediction and generate the CAT plasma and neutron loading needed for further engineering analysis: $/circ$ Initially run CESOL with SOLPS and map heat flux using simple HEAT method: ▪ Generate SOLPS grid for CAT reference case, ▪ Implement and apply ‘lower’ fidelity method of using HEAT-like analytic method to map SOLPS heat flux from charged particles to first wall, and ▪ Provide initial heat flux + neutron loading for further engineering analysis. 2. Demonstrate multiphysics magnet analysis: $/circ$ Demonstrate validation of the Elmer workflow by comparing induced stresses due to EM forces generated by TF coils using multiple codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Hybrid Energy System Workflow for Energy Portfolio Optimization

This manuscript develops a workflow, driven by data analytics algorithms, to support the optimization of the economic performance of an Integrated Energy System. The goal is to determine the optimum mix of capacities from a set of different energy producers (e.g., nuclear, gas, wind and solar). A stochastic-based optimizer is employed, based on Gaussian Process Modeling, which requires numerous samples for its training. Each sample represents a time series describing the demand, load, or other operational and economic profiles for various types of energy producers. These samples are synthetically generated using a reduced order modeling algorithm that reads a limited set of historical data, such as demand and load data from past years. Numerous data analysis methods are employed to construct the reduced order models, including, for example, the Auto Regressive Moving Average, Fourier series decomposition, and the peak detection algorithm. All these algorithms are designed to detrend the data and extract features that can be employed to generate synthetic time histories that preserve the statistical properties of the original limited historical data. The optimization cost function is based on an economic model that assesses the effective cost of energy based on two figures of merit: the specific cash flow stream for each energy producer and the total Net Present Value. An initial guess for the optimal capacities is obtained using the screening curve method. The results of the Gaussian Process model-based optimization are assessed using an exhaustive Monte Carlo search, with the results indicating reasonable optimization results. The workflow has been implemented inside the Idaho National Laboratory’s Risk Analysis and Virtual Environment (RAVEN) framework. The main contribution of this study addresses several challenges in the current optimization methods of the energy portfolios in IES: First, the feasibility of generating the synthetic time series of the periodic peak data; Second, the computational burden of the conventional stochastic optimization of the energy portfolio, associated with the need for repeated executions of system models; Third, the inadequacies of previous studies in terms of the comparisons of the impact of the economic parameters. The proposed workflow can provide a scientifically defendable strategy to support decision-making in the electricity market and to help energy distributors develop a better understanding of the performance of integrated energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

User's manual for the TRW gaspipe 2 program: A vapor-gas front analysis program for heat pipes containing non-condensible gas

A digital computer program for design and analysis of heat pipes which contain non-condensible gases, either for temperature control or to aid in start-up from the frozen state, is presented. Some of the calculations which are possible with the program are: (1) wall temperature profile along a gas-loaded heat pipe, (2) amount of gas loading necessary to obtain desired evaporator temperature at a desired heat load, (3) heat load versus evaporator temperature for a fixed amount of gas in the pipe, and (4) heat and mass transfer along the pipe, including the vapor-gas front region.

Edwards, D. K.↗

Wind-tunnel test results of a full-scale multicyclic controllable twist rotor

Results of wind tunnel testing of a multicyclic controllable twist rotor at several flight conditions and advance ratios of 0.22 and 0.33 are evaluated. It is found that blade flatwise bending moments and root control actuator loads (fixed system) can be reduced with multicyclic control. Flatwise bending moment reductions of 22-30% with concurrent 83% reductions in control loads were predicted. Analysis of profile power changes indicates a decrease in profile power coefficient of 0.00016, corresponding to a loss of 0.12 sq m of equivalent drag area.

Mccloud, J. L., III↗