Search NASA⌕ Search

SEARCH · Search NASA

Results for “Marginal Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

EUV and FUV observations of cataclysmic variables

Recent results from a continuing investigation of cataclysmic variables in the 500 to 1700 A region with the Voyager ultraviolet spectrometers are presented. Observations of outbursts show a substantial delay (of about 0.5 day) in the rise to maximum in the FUV (912-1200 A) with respect to optical wavelengths. Both FUV and optical light decline simultaneously. Flux distributions show a significant flattening in the FUV and with the possible exception of CPD-48 1577 no EUV flux has been observed in any cataclysmic variable. CPD-48 1577 shows a marginal, 2 sigma, EUV flux.

Polidan, R. S.↗

LOX/hydrogen coaxial injector atomization test program

Quantitative information about the atomization of injector sprays is needed to improve the accuracy of computational models that predict the performance and stability margin of liquid propellant rocket engines. To obtain this data, a facility for the study of spray atomization is being established at NASA-Lewis to determine the drop size and velocity distributions occurring in vaporizing liquid sprays at supercritical pressures. Hardware configuration and test conditions are selected to make the cold flow simulant testing correspond as closely as possible to conditions in liquid oxygen (LOX)/gaseous H2 rocket engines. Drop size correlations from the literature, developed for liquid/gas coaxial injector geometries, are used to make drop size predictions for LOX/H2 coaxial injectors. The mean drop size predictions for a single element coaxial injector range from 0.1 to 2000 microns, emphasizing the need for additional studies of the atomization process in LOX/H2 engines. Selection of cold flow simulants, measurement techniques, and hardware for LOX/H2 atomization simulations are discussed.

Zaller, M.↗

LOX/Hydrogen Coaxial Injector Atomization Test Program

Quantitative information about the atomization of injector sprays is needed to improve the accuracy of computational models that predict the performance and stability margin of liquid propellant rocket engines. To obtain this data, a facility for the study of spray atomization is being established at NASA-Lewis to determine the drop size and velocity distributions occurring in vaporizing liquid sprays at supercritical pressures. Hardware configuration and test conditions are selected to make the cold flow simulant testing correspond as closely as possible to conditions in liquid oxygen (LOX)/gaseous H2 rocket engines. Drop size correlations from the literature, developed for liquid/gas coaxial injector geometries, are used to make drop size predictions for LOX/H2 coaxial injectors. The mean drop size predictions for a single element coaxial injector range from 0.1 to 2000 microns, emphasizing the need for additional studies of the atomization process in LOX/H2 engines. Selection of cold flow simulants, measured techniques, and hardware for LOX/H2 atomization simulations are discussed.

Zaller, M.↗

Demonstration of a Probabilistic Technique for the Determination of Economic Viability of Very Large Transport Configurations

Over the past few years, modem aircraft design has experienced a paradigm shift from designing for performance to designing for affordability. This report contains a probabilistic approach that will allow traditional deterministic design methods to be extended to account for disciplinary, economic, and technological uncertainty. The probabilistic approach was facilitated by the Fast Probability Integration (FPI) technique; a technique which allows the designer to gather valuable information about the vehicle's behavior in the design space. This technique is efficient for assessing multi-attribute, multi-constraint problems in a more realistic fashion. For implementation purposes, this technique is applied to illustrate how both economic and technological uncertainty associated with a Very Large Transport aircraft concept may be assessed. The assessment is evaluated with the FPI technique to determine the cumulative probability distributions of the design space, as bound by economic objectives and performance constraints. These distributions were compared to established targets for a comparable large capacity aircraft, similar in size to the Boeing 747-400. The conventional baseline configuration design space was determined to be unfeasible and marginally viable, motivating the infusion of advanced technologies, including reductions in drag, specific fuel consumption, wing weight, and Research, Development, Testing, and Evaluation costs. The resulting system design space was qualitatively assessed with technology metric "k" factors. The infusion of technologies shifted the VLT design into regions of feasibility and greater viability. The study also demonstrated a method and relationship by which the impact of new technologies may be assessed in a more system focused approach.

Mavris, Dimitri N.↗

Algorithm Development and Validation for Satellite-Derived Distributions of DOC and CDOM in the US Middle Atlantic Bight

In coastal ocean waters, distributions of dissolved organic carbon (DOC) and chromophoric dissolved organic matter (CDOM) vary seasonally and interannually due to multiple source inputs and removal processes. We conducted several oceanographic cruises within the continental margin of the U.S. Middle Atlantic Bight (MAB) to collect field measurements in order to develop algorithms to retrieve CDOM and DOC from NASA's MODIS-Aqua and SeaWiFS satellite sensors. In order to develop empirical algorithms for CDOM and DOC, we correlated the CDOM absorption coefficient (a(sub cdom)) with in situ radiometry (remote sensing reflectance, Rrs, band ratios) and then correlated DOC to Rrs band ratios through the CDOM to DOC relationships. Our validation analyses demonstrate successful retrieval of DOC and CDOM from coastal ocean waters using the MODIS-Aqua and SeaWiFS satellite sensors with mean absolute percent differences from field measurements of < 9 %for DOC, 20% for a(sub cdom)(355)1,6 % for a(sub cdom)(443), and 12% for the CDOM spectral slope. To our knowledge, the algorithms presented here represent the first validated algorithms for satellite retrieval of a(sub cdom) DOC, and CDOM spectral slope in the coastal ocean. The satellite-derived DOC and a(sub cdom) products demonstrate the seasonal net ecosystem production of DOC and photooxidation of CDOM from spring to fall. With accurate satellite retrievals of CDOM and DOC, we will be able to apply satellite observations to investigate interannual and decadal-scale variability in surface CDOM and DOC within continental margins and monitor impacts of climate change and anthropogenic activities on coastal ecosystems.

Mannino, Antonio↗

Cryogenic Vacuum Chamber Testing of A Conductively-Cooled, High Temperature Superconducting Rotor for a 1.4 MW Electric Machine for Aeronautics Applications

This paper presents the second ever demonstration of a superconducting rotor cooled only via conductive connection to a cryocooler, i.e., without pumped or solid cryogens. The fullscale rotor was operated statically in its intended environment – about 1e-3 torr vacuum with only conductive cooling through mechanical connections to a cryocooler contained on the rotor. Stable operation of the rotor in a representative magnetic environment was demonstrated up to its rated direct current (57.2 A) and the designed temperature limit for the superconductor (62 K). Additional electrical measurements increased confidence that the superconducting coils functioned as intended. A collection of steady state temperature distributions was measured at operating and non-operating conditions. In all but one case, the observed temperature gradient between the cold tip and superconducting coils satisfies the design but with little margin. Opportunities to reduce the gradient are identified.

Electrified aircraft propulsion↗

Cryogenic Vacuum Chamber Testing of A Conductively-Cooled, High Temperature Superconducting Rotor for a 1.4 MW Electric Machine for Aeronautics Applications

This paper presents the first ever demonstration of a superconducting rotor cooled conductively without a cryogenic fluid or solid. The full-scale rotor was operated statically in its intended environment – about 1e-3 torr vacuum with only conductive cooling through mechanical connections to a cryocooler contained on the rotor. Stable operation of the rotor in a representative magnetic environment was demonstrated up to its rated direct current (57.2 A) and the designed temperature limit for the superconductor (62 K). Additional electrical measurements increased confidence that the superconducting coils functioned as intended. A collection of steady state temperature distributions was measured at operating and non-operating conditions. In all but one case, the observed temperature gradient between the cold tip and superconducting coils satisfies the design but with little margin. Opportunities to reduce the gradient are identified.

Electrified aircraft propulsion↗

Multispectral mapping of the Apollo 15-Apennine region - The identification and distribution of regional pyroclastic deposits

Multispectral mapping of the Apollo 15-Apennine region has allowed the identification of numerous dark mantle deposits of probable pyroclastic origin. The deposits display a low albedo, appear to mantle and slightly subdue subjacent terrain, are spectrally distinct on the multispectral maps (high in the infrared but low in the ultraviolet) and generally exhibit a weak depolarized 3.8 cm radar echo. These characteristics are consistent with an origin by pyroclastic eruption. The regional dark mantle deposits are commonly associated with vents along marginal fractures and faults near the base of the Apennines, thereby emphasizing the role of basin-controlled weaknesses in providing channels for the upward migration of magma generated at depth. The spectral properties of the pyroclastic deposits are incompatible with those of Apollo 15 green glass but the deposits may be composed of material similar to the Apollo 15 brown or yellow glass. If so, the widespread distribution of the deposits suggest that mare basalts genetically related to the brown or yellow glass may occur in the Apollo 15 region. Moreover, pyroclastic volcanic activity has apparently been a more important and widespread process in the Apollo 15-Apennine region than has previously been thought.

Hawke, B. R.↗

The C-5A active lift distribution control system

The ALDCS development and design tasks, ALDCS functional configuration, and resulting challenges encountered while accomplishing the first phase of the program are described. These tasks are establishing system requirements and criteria and synthesizing a system mechanization to meet the desired load alleviation, stability margins, flight safety, and flying qualities performance. Results of the ALDCS development and prototype system flight simulation programs, and control law optimization including system stability, handling qualities and structural load analyses are presented, along with concluding remarks relative to the system design integration.

Hargrove, W. J.↗

SU-E-J-55: Dosimetric Evaluation of Centrally Located Lung Tumors: A Monte Carlo (MC) Study of Lung SBRT Planning

Purpose: To compare dose distributions calculated using the iPlan XVMC algorithm and heterogeneities corrected/uncorrected Pencil Beam (PB-hete/PB-homo) algorithms for SBRT treatments of lung tumors. Methods: Ten patients with centrally located solitary lung tumors were treated using MC-based SBRT to 60Gy in 5 fractions for PTVV100%=95%. ITV was delineated on MIP-images based on 4D-CT scans. PTVs(ITV+5mm margins) ranged from 10.1–106.5cc(mean=48.6cc). MC-SBRT plans were generated with a combination of non-coplanar conformal arcs/beams using iPlan-XVMC-algorithm (BrainLABiPlan ver.4.1.2) for Novalis-TX consisting of HD-MLCs and 6MV-SRS(1000MU/min) mode, following RTOG 0813 dosimetric criteria. For comparison, PB-hete/PB-homo algorithms were used to re-calculate dose distributions using same beam configurations, MLCs/monitor units. Plans were evaluated with isocenter/maximal/mean doses to PTV. Normal lung doses were evaluated with V5/V10/V20 and mean-lung-dose(MLD), excluding PTV. Other OAR doses such as maximal spinal cord/2cc-esophagus/max bronchial tree (BT/maximal heart doses were tabulated. Results: Maximal/mean/isocenter doses to PTV calculated by PB-hete were uniformly larger than MC plans by a factors of 1.09/1.13/1.07, on average, whereas they were consistently lower by PB-homo by a factors of 0.9/0.84/0.9, respectively. The volume covered by 5Gy/10Gy/20Gy isodose-lines of the lung were comparable (average within±3%) when calculated by PB-hete compared to XVMC, but, consistently lower by PB-homo by a factors of 0.90/0.88/0.85, respectively. MLD was higher with PB-hete by 1.05, but, lower by PB-homo by 0.9, on average, compared to XVMC. XVMC max-cord/max-BT/max-heart and 2cc of esophagus doses were comparable to PB-hete; however, PB-homo underestimates by a factors of 0.82/0.89/0.88/0.86, on average, respectively. Conclusion: PB-hete significantly overestimates dose to PTV relative to XVMC -hence underdosing the target. MC is more complex and accurate with tissue-heterogeneities.The magnitude of variation significantly varies with ‘small-island-tumor’ surrounded by low-density lung tissues -PB algorithms lacks later electron scattering. Dose calculation with XVMC for lung SBRT is routinely performed in our clinic, its performance for head'neck/sinus cases will also be investigated.

60 APPLIED LIFE SCIENCES↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

A Model Study of the Relative Influences of Scavenging and Circulation on 230Th and 231Pa in the Western North Atlantic

The oceanic cycles of thorium-230 and protactinium-231 are affected by a number of processes, such as removal by adsorption to settling particles and transport by ocean currents. Measurements obtained as part of GEOTRACES and earlier programs have shown that, in the North Atlantic, the activities of dissolved 230Th (230Thd) and 231Pa (231Pad) at abyssal depths are lower near the western margin than in the basin interior. At least two factors could explain the lower 230Thd and 231Pad near the margin: (i) intensified scavenging in benthic nepheloid layers (BNLs) extending a thousand meters or more above the seafloor; and (ii) ventilation by relatively 230Thd- and 231Pad-poor waters emanating from the Deep Western Boundary Current (DWBC).Here a regional ocean circulation model with ?eddy-permitting' resolution (1/4) that incorporates 230Th and 231Pa is used in an effort to reproduce the observed distributions of 230Th and 231Pa in the western North Atlantic. In this model, 230Th and 231Pa removal from solution is governed by a prescribed distribution of particulate matter that is derived from a recent synthesis of nephelometer and transmissometer data. The model simulates a meandering Gulf Stream and a DWBC along the continental slope and rise, although noticeable differences with physical observations also exist. A model solution is found that explains most of the variance of 230Thd measurements (85%) and 231Pad measurements (81%) from (pre-)GEOTRACES cruises. On the other hand, measurements of particulate 230Th (230Thp) and 231Pa (231Pap) are more difficult to reproduce, with the same solution accounting for only 49% (11%) of the 230Thp (231Pap) variance. Sensitivity experiments suggest that the low 230Thd and 231Pad activities observed near the western margin are due to enhanced removal rates of both nuclides in BNLs rather than to deep water ventilation from the western boundary. The radionuclide activities present in the DWBC at its inflow location are also found to strongly influence the basin-scale distributions of 230Th and 231Pa. Overall, our study points to BNLs as important sites of 230Th and 231Pa scavenging in the ocean and illustrates the difficulty to explain simultaneously radionuclide measurements in dissolved and particulate forms in the studied area.

Lerner, Paul↗

THE SLOAN DIGITAL SKY SURVEY QUASAR LENS SEARCH. VI. CONSTRAINTS ON DARK ENERGY AND THE EVOLUTION OF MASSIVE GALAXIES

We present a statistical analysis of the final lens sample from the Sloan Digital Sky Survey Quasar Lens Search (SQLS). The number distribution of a complete subsample of 19 lensed quasars selected from 50,836 source quasars is compared with theoretical expectations, with particular attention given to the selection function. Assuming that the velocity function of galaxies does not evolve with redshift, the SQLS sample constrains the cosmological constant to {Omega}{sub {Lambda}} = 0.79{sup +0.06}{sub -0.07}(stat.){sup +0.06}{sub -0.06}(syst.) for a flat universe. The dark energy equation of state is found to be consistent with w = -1 when the SQLS is combined with constraints from baryon acoustic oscillation (BAO) measurements or results from the Wilkinson Microwave Anisotropy Probe (WMAP). We also obtain simultaneous constraints on cosmological parameters and redshift evolution of the galaxy velocity function, finding no evidence for redshift evolution at z {approx}< 1 in any combinations of constraints. For instance, number density evolution quantified as {nu}{sub n} {identical_to} dln {phi}{sub *}/dln (1 + z) and the velocity dispersion evolution {nu}{sub {sigma}} {identical_to} dln {sigma}{sub *}/dln (1 + z) are constrained to {nu}{sub n} = 1.06{sup +1.36}{sub -1.39}(stat.){sup +0.33}{sub -0.64}(syst.) and {nu}{sub {sigma}} = -0.05{sup +0.19}{sub -0.16}(stat.){sup +0.03}{sub -0.03}(syst.), respectively, when the SQLS result is combined with BAO and WMAP for flat models with a cosmological constant. We find that a significant amount of dark energy is preferred even after fully marginalizing over the galaxy evolution parameters. Thus, the statistics of lensed quasars robustly confirm the accelerated cosmic expansion.

79 ASTRONOMY AND ASTROPHYSICS↗

A method of dose reconstruction for moving targets compatible with dynamic treatments

Purpose: To develop a method that allows a commercial treatment planning system (TPS) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (IMRT), volumetric arc therapy (VMAT), and dynamic multileaf collimator (DMLC) tracking. Methods: An in-house computer program was developed to manipulate Dicom treatment plans exported from a TPS (Eclipse, Varian Medical Systems) such that target motion during treatment delivery was incorporated into the plans. For each treatment, a motion including plan was generated by dividing the intratreatment target motion into 1 mm position bins and construct sub-beams that represented the parts of the treatment that were delivered, while the target was located within each position bin. For each sub-beam, the target shift was modeled by a corresponding isocenter shift. The motion incorporating Dicom plans were reimported into the TPS, where dose calculation resulted in motion including target dose distributions. For experimental validation of the dose reconstruction a thorax phantom with a moveable lung equivalent rod with a tumor insert of solid water was first CT scanned. The tumor insert was delineated as a gross tumor volume (GTV), and a planning target volume (PTV) was formed by adding margins. A conformal plan, two IMRT plans (step-and-shoot and sliding windows), and a VMAT plan were generated giving minimum target doses of 95% (GTV) and 67% (PTV) of the prescription dose (3 Gy). Two conformal fields with MLC leaves perpendicular and parallel to the tumor motion, respectively, were generated for DMLC tracking. All treatment plans were delivered to the thorax phantom without tumor motion and with a sinusoidal tumor motion. The two conformal fields were delivered with and without portal image guided DMLC tracking based on an embedded gold marker. The target dose distribution was measured with a radiochromic film in the moving rod and compared with the reconstructed doses using gamma tests. Results: Considerable interplay effects between machine motion and target motion were observed for the treatments without tracking. For nontracking experiments, the mean 2 mm/2% gamma pass rate over all investigated scenarios was 99.6% between calculated and measured doses. For tracking experiments, the mean gamma pass rate was 99.4%. Conclusions: A method for accurate dose reconstruction for moving targets with dynamic treatments was developed and experimentally validated in a variety of delivery scenarios. The method is suitable for integration into TPSs, e.g., for reconstruction of the dose delivered to moving tumors or calculation of target doses delivered with DMLC tracking.

60 APPLIED LIFE SCIENCES↗

SU-F-J-151: Evaluation of a Magnetic Resonance Image Gated Radiotherapy System Using a Motion Phantom and Radiochromic Film

Purpose: Magnetic resonance image (MRI) guided radiotherapy enables gating directly on target position for soft-tissue targets in the lung and abdomen. We present a dosimetric evaluation of a commercially-available FDA-approved MRI-guided radiotherapy system’s gating performance using a MRI-compatible respiratory motion phantom and radiochromic film. Methods: The MRI-compatible phantom was capable of one-dimensional motion. The phantom consisted of a target rod containing high-contrast target inserts which moved inside a body structure containing background contrast material. The target rod was equipped with a radiochromic film insert. Treatment plans were generated for a 3 cm diameter spherical target, and delivered to the phantom at rest and in motion with and without gating. Both sinusoidal and actual tumor trajectories (two free-breathing trajectories and one repeated-breath hold) were used. Gamma comparison at 5%/3mm was used to measure fidelity to the static target dose distribution. Results: Without gating, gamma pass rates were 24–47% depending on motion trajectory. Using our clinical standard of repeated breath holds and a gating window of 3 mm with 10% of the target allowed outside the gating boundary, the gamma pass rate was 99.6%. Relaxing the gating window to 5 mm resulted in gamma pass rate of 98.6% with repeated breath holds. For all motion trajectories gated with 3 mm margin and 10% allowed out, gamma pass rates were between 64–100% (mean:87.5%). For a 5 mm margin and 10% allowed out, gamma pass rates were between 57–98% (mean: 82.49%), significantly lower than for 3 mm by paired t-test (p=0.01). Conclusion: We validated the performance of respiratory gating based on real-time cine MRI images with the only FDA-approved MRI-guided radiotherapy system. Our results suggest that repeated breath hold gating should be used when possible for best accuracy. A 3 mm gating margin is statistically significantly more accurate than a 5 mm gating margin.

60 APPLIED LIFE SCIENCES↗

Evaluating design safety margins in the American Society of Mechanical Engineers graphite core components design-by-analysis assessments

Graphite is an important material being used for core components in next-generation high-temperature gas-cooled nuclear reactors. The selection of graphite grade for a specific Designer is a complex task, dependent on reactor conditions, component functionality, and required reliability. The American Society of Mechanical Engineers (ASME) provides two semi-probabilistic design-by-analysis assessments to evaluate graphite core components against design reliability targets. The simplified assessment uses a 2-parameter Weibull distribution to describe the graphite grade’s tensile-strength distribution to establish component stress limits. The full assessment uses the 3-parameter Weibull distribution and a modified Weakest-Link Theory approach to calculate a component design probability of failure. The paper defines recommended assessment rules, which are the as-written simplified assessment and the full assessment with parameter lower bounds, the modulus update with threshold reduction, and the 2027 grouping rules. Code rules are applied to three grades: 2114, IG-110, and NBG-18. The baseline margin calculation is developed using the experimental tensile dogbone specimen. Percent margin is defined as the percent reduction in the median experimental load to obtain the allowable load per ASME assessments. Under the recommended rules, the SRC–1 margin in the simplified assessment ranged from 40.2 % to 52.7 % among the grades in this study and from 36.1 % to 49.8 % in the full assessment. The full assessment only decreases the margins by 2.5–4.5 % for the SRC-1 components and 0–1.5 % for the SRC-2 components for this baseline case. Margin is inversely related to material median strength (i.e., the strongest grade, 2114, has the lowest margin).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TRAJECTORY SENSITIVITY ANALYSIS FOR DYNAMIC SECURITY ASSESSMENT AND OTHER APPLICATIONS IN POWER SYSTEMS

Real time stability evaluation and preventive scheduling in power systems offer many challenges in a stressed power system. Trajectory sensitivity analysis (TSA) is a useful tool for this and other applications in the emerging smart grid area. In this chapter we outline the basic approach of TSA, to extract suitable information from the data and develop reliable metrics or indices to evaluate proximity of the system to an unstable condition. Trajectory sensitivities can be used to compute critical parameters such as clearing time of circuit breakers, tie line flow, etc. in a power system by developing suitable norms for ease of interpretation. The TSA technique has the advantage that model complexity is not a limitation, and the sensitivities can be computed numerically. Suitable metrics are developed from these sensitivities. The TSA technique can be extended to do preventive rescheduling. A brief discussion of other applications of TSA in placement of distributed generation is indicated.

critical parameter computation↗

Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy

Purpose: To develop a method for dose reconstruction by incorporating the interplay effect between aperture modulation and target motion, and to assess the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy (VMAT). Methods and Materials: Clinical VMAT plans were delivered with the TrueBeam linac for 8 patients with prostate cancer. The real-time target motion during dose delivery was determined based on the 2-dimensional fiducial localization using an onboard electronic portal imaging device. The target shift in each image was correlated with the control point with the same gantry angle in the VMAT plan. An in-house-developed Monte Carlo simulation tool was used to calculate the 3-dimensional dose distribution for each control point individually, taking into account the corresponding real-time target motion (assuming a nondeformable target with no rotation). The delivered target dose was then estimated by accumulating the dose from all control points in the plan. On the basis of this information, dose–volume histograms and 3-dimensional dose distributions were calculated to assess their degradation from the planned dose caused by target motion. Thirty-two prostate motion trajectories were analyzed. Results: The minimum dose to 0.03 cm{sup 3} of the gross tumor volume (D{sub 0.03cc}) was only slightly degraded after taking motion into account, with a minimum value of 94.1% of the planned dose among all patients and fractions. However, the gross tumor volume receiving prescription dose (V{sub 100%}) could be largely affected by motion, dropping below 60% in 1 trajectory. We did not observe a correlation between motion magnitude and dose degradation. Conclusions: Prostate motion degrades the delivered dose to the target in an unpredictable way, although its effect is reduced over multiple fractions, and for most patients the degradation is small. Patients with greater prostate motion or those treated with stereotactic body radiation therapy would benefit from real-time prostate tracking to reduce the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗