Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Luminescence and photosensitization properties of ensembles of silicon nanocrystals in terms of an exciton migration model

The relaxation processes that occur in ensembles of coupled silicon nanocrystals are described by a quantitative model that takes into account the energy transfer between them during exciton migration. This model is used to study the formation of singlet oxygen during the photoexcitation of silicon nanocrystals in porous silicon layers under various external conditions. It is experimentally found that, upon fine milling of as-deposited porous silicon films, the photoluminescence decay time increases despite an increase in the concentration of point defects. The photosensitized activity of ensembles of silicon nanocrystals degrades monotonically during their photostimulated oxidation. These experimental results agree completely with the conclusions of the model and are explained by a decrease in the number of exciton migration ways between nanocrystals when the granule size of a porous silicon powder decreases and by an increase in the efficiency of nonradiative recombination during the photostimulated oxidation of the nanocrystals. Our data indicate that nanocrystalline silicon is a promising material for the methods of nontoxic photodynamic therapy of oncological diseases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The first 3D malonate bridged copper [Cu(O{sub 2}C-CH{sub 2}-CO{sub 2}H){sub 2}{center_dot}2H{sub 2}O]: Structure, properties and electronic structure

A new inorganic-organic compound [Cu(O{sub 2}C-CH{sub 2}-CO{sub 2}H){sub 2}{center_dot}2H{sub 2}O] ([Cumal]) was hydrothermally synthesized and characterized by IR spectroscopy, thermal analysis and single crystal X-ray diffraction. [Cumal] is the first three-dimensional compound existing in the system Cu(II)-malonic acid-H{sub 2}O. Its framework is built up through carboxyl bridged copper where CuO{sub 6} octahedra are elongated with an almost D{sub 4h} symmetry (4+2) due to the Jahn-Teller effect. The magnetic properties were studied by measuring its magnetic susceptibility in the temperature range of 2-300 K indicating the existence of weak ferromagnetic interactions. The electronic structure of [Cumal] was calculated within the density functional theory (DFT) framework. Structural features are well reproduced using DFT structural optimizations and the optical spectra, calculated within the dielectric formalism, explain very well the light blue colour of the compound. It is shown that a GGA+U approach with a U{sub eff} value of about 6 eV is necessary for a better correlation with the experiment. - Graphical abstract: [Cu(O{sub 2}C-CH{sub 2}-CO{sub 2}H){sub 2}{center_dot}2H{sub 2}O]: the first 3D hybrid organic-inorganic compound built up carboxyl groups. The network presents a diamond-like structure achieved via carboxyl. Highlights: Black-Right-Pointing-Pointer A new organic-inorganic material with an unprecedented topology is synthesized. Black-Right-Pointing-Pointer Crystallographic structure is determined using single crystal X-ray diffraction. Black-Right-Pointing-Pointer Electronic structure is obtained from DFT, GGA+U calculation. Black-Right-Pointing-Pointer Framework can be described as formed from CuC{sub 4} tetrahedron sharing four corners. Black-Right-Pointing-Pointer This structure can be classified as an extended diamond structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anomalous properties and the liquid-liquid phase transition in gallium

A group of materials including water and silicon exhibit many anomalous behaviors, e.g., density anomaly and diffusivity anomaly (increase upon compression). These materials are hypothesized to have a liquid-liquid phase transition (LLPT) and the critical fluctuation in the vicinity of the liquid-liquid critical point is considered as the origin of different anomalies. Liquid gallium was also reported to have a LLPT, yet whether it shows similar water-like anomalies is not yet studied. Using molecular dynamics simulations on a modified embedded-atom model, we study the thermodynamic, dynamic, and structural properties of liquid gallium as well as its LLPT. We find that, similar to water-like materials predicted to have the LLPT, gallium also shows different anomalous behaviors (e.g., density anomaly, diffusivity anomaly, and structural anomaly). We also find that its thermodynamic and structural response functions are continuous and show maxima in the supercritical region, the loci of which asymptotically approach to the other and merge to the Widom line. These phenomena are consistent with the supercritical phenomenon in a category of materials with a liquid-liquid critical point, which could be common features in most materials with a LLPT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of annealing on the laser induced damage of polished and CO{sub 2} laser-processed fused silica surfaces

We investigate the effect of different heat treatments on the laser-induced damage probabilities of fused silica samples. Isothermal annealing in a furnace is applied, with different temperatures in the range 700–1100 °C and 12 h annealing time, to super-polished fused silica samples. The surface flatness and laser damage probabilities at 3 ns, 351 nm are measured before and after the different annealing procedures. We have found a significant improvement of the initial laser damage probabilities of the silica surface after annealing at 1050 °C for 12 h. A similar study has been conducted on CO{sub 2} laser-processed sites on the surface of the samples. Before and after annealing, we have studied the morphology of the sites, the evolution of residual stress, and the laser-induced damage threshold measured at 351 nm, 3 ns. In this case, we observe that the laser damage resistance of the laser created craters can reach the damage level of the bare fused silica surface after the annealing process, with a complete stress relieve. The obtained results are then compared to the case of local annealing process by CO{sub 2} laser irradiation during 1 s, and we found similar improvements in both cases. The different results obtained in the study are compared to numerical simulations made with a thermo-mechanical model based on finite-element method that allows the simulation of the isothermal or the local annealing process, the evolution of stress and fictive temperature. The simulation results were found to be very consistent with experimental observations for the stresses evolution after annealing and estimation of the heat affected area during laser-processing based on the density dependence with fictive temperature. Following this work, the temperature for local annealing should reach 1330–1470 °C for an optimized reduction of damage probability and be below the threshold for material removal, whereas furnace annealing should be kept below the annealing point to avoid sample deformation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic defects in monolayer titanium carbide (Ti 3 C 2 T x ) MXene

Here, the 2D transition metal carbides or nitrides, or MXenes, are emerging as a group of materials showing great promise in lithium ion batteries and supercapacitors. Until now, characterization and properties of single-layer MXenes have been scarcely reported. Here, using scanning transmission electron microscopy, we determined the atomic structure of freestanding monolayer Ti 3 C 2 T x flakes prepared via the minimally intensive layer delamination method and characterized different point defects that are prevalent in the monolayer flakes. We determine that the Ti vacancy concentration can be controlled by the etchant concentration during preparation. Density function theory-based calculations confirm the defect structures and predict that the defects can influence the surface morphology and termination groups, but do not strongly influence the metallic conductivity. Using devices fabricated from single- and few-layer Ti 3 C 2 T x MXene flakes, the effect of the number of layers in the flake on conductivity has been demonstrated.

36 MATERIALS SCIENCE↗

Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms

Purpose: This work presents the development of a phantom to verify the treatment planning system (TPS) algorithms used for high-dose-rate (HDR) brachytherapy. It is designed to measure the relative dose in a heterogeneous media. The experimental details used, simulation methods, and comparisons with a commercial TPS are also provided. Methods: To simulate heterogeneous conditions, four materials were used: Virtual Water™ (VM), BR50/50™, cork, and aluminum. The materials were arranged in 11 heterogeneity configurations. Three dosimeters were used to measure the relative response from a HDR {sup 192}Ir source: TLD-100™, Gafchromic{sup ®} EBT3 film, and an Exradin™ A1SL ionization chamber. To compare the results from the experimental measurements, the various configurations were modeled in the PENELOPE/penEasy Monte Carlo code. Images of each setup geometry were acquired from a CT scanner and imported into BrachyVision™ TPS software, which includes a grid-based Boltzmann solver Acuros™. The results of the measurements performed in the heterogeneous setups were normalized to the dose values measured in the homogeneous Virtual Water™ setup and the respective differences due to the heterogeneities were considered. Additionally, dose values calculated based on the American Association of Physicists in Medicine-Task Group 43 formalism were compared to dose values calculated with the Acuros™ algorithm in the phantom. Calculated doses were compared at the same points, where measurements have been performed. Results: Differences in the relative response as high as 11.5% were found from the homogeneous setup when the heterogeneous materials were inserted into the experimental phantom. The aluminum and cork materials produced larger differences than the plastic materials, with the BR50/50™ material producing results similar to the Virtual Water™ results. Our experimental methods agree with the PENELOPE/penEasy simulations for most setups and dosimeters. The TPS relative differences with the Acuros™ algorithm were similar in both experimental and simulated setups. The discrepancy between the BrachyVision™, Acuros™, and TG-43 dose responses in the phantom described by this work exceeded 12% for certain setups. Conclusions: The results derived from the phantom measurements show good agreement with the simulations and TPS calculations, using Acuros™ algorithm. Differences in the dose responses were evident in the experimental results when heterogeneous materials were introduced. These measurements prove the usefulness of the heterogeneous phantom for verification of HDR treatment planning systems based on model-based dose calculation algorithms.

07 ISOTOPE AND RADIATION SOURCES↗

Dynamic Contrast-Enhanced MRI of Cervical Cancers: Temporal Percentile Screening of Contrast Enhancement Identifies Parameters for Prediction of Chemoradioresistance

Purpose: To systematically screen the tumor contrast enhancement of locally advanced cervical cancers to assess the prognostic value of two descriptive parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Methods and Materials: This study included a prospectively collected cohort of 81 patients who underwent DCE-MRI with gadopentetate dimeglumine before chemoradiotherapy. The following descriptive DCE-MRI parameters were extracted voxel by voxel and presented as histograms for each time point in the dynamic series: normalized relative signal increase (nRSI) and normalized area under the curve (nAUC). The first to 100th percentiles of the histograms were included in a log-rank survival test, resulting in p value and relative risk maps of all percentile-time intervals for each DCE-MRI parameter. The maps were used to evaluate the robustness of the individual percentile-time pairs and to construct prognostic parameters. Clinical endpoints were locoregional control and progression-free survival. The study was approved by the institutional ethics committee. Results: The p value maps of nRSI and nAUC showed a large continuous region of percentile-time pairs that were significantly associated with locoregional control (p < 0.05). These parameters had prognostic impact independent of tumor stage, volume, and lymph node status on multivariate analysis. Only a small percentile-time interval of nRSI was associated with progression-free survival. Conclusions: The percentile-time screening identified DCE-MRI parameters that predict long-term locoregional control after chemoradiotherapy of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Power optics

By using the theory we developed in the early 1970s, a broad range of phenomena is considered for an optical surface of a solid body that is exposed to radiation arbitrarily varying in time and producing temperature fields, thermoelastic stresses and thermal deformations on the surface layer. The examination is based on the relations (which are similar to Duhamel's integral formula from the theory of heat conduction) between the quantities characterising the thermal stress state in any nonstationary regimes of energy input into a solid. A peculiar feature of the analysis of the thermal stress state in this case consists in the fact that this relation comprises time as a parameter, which in turn is a consequence of incoherence of the quasi-stationary problem of thermoelasticity. This phenomenon is particularly important for the optics of high-power, high-pulse repetition rate lasers, which are being actively developed. In the review, we have recently published in Laser Physics, the thermal stress state of a solid is analysed. In this state, time is treated as an independent variable used in differentiation. Such an approach greatly reduces the applicability of the method. The review published contains data on the use of capillary porous structures made of various materials with different degrees of the surface development. Moreover, such structures can be efficiently employed to increase the heat exchange at a temperature below the boiling point of the coolant. In the present review we discuss the dependences of the limiting laser intensities on the duration of a pulse or a pulse train, corresponding to the three stages of the state of the reflecting surface and leading to unacceptable elastic deformations of the surface, to the plastic yield of the material accompanied by the formation of residual stresses and to the melting of the surface layer. We also analyse the problem of heat exchange in the surface layer with a liquid metal coolant pumped through it. The theoretical estimates are compared with the experimental data. We discuss the issues related to the technology of fabrication of power optics elements based on materials with a porous structure, of lightweight highly stable large optics based on highly porous materials, multi-layer honeycomb structures and silicon carbide, as well as problems of application of physical and technical fundamentals of power optics in modern cutting-edge technology. (invited paper)

36 MATERIALS SCIENCE↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT 4

Purpose: This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and GEANT4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. Methods: A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within the Monaco treatment planning system to model dose for the Elekta™ magnetic resonance imaging (MRI) Linac, was compared against GEANT4 (v10.1). This was done in the presence or absence of a 1.5 T static magnetic field directed orthogonally to the radiation beam axis. Phantoms with material compositions of water, ICRU lung, ICRU compact-bone, and titanium were used for this purpose. Beams with 2 MeV monoenergetic photons as well as a 7 MV histogrammed spectrum representing the MRI Linac spectrum were emitted from a point source using a nominal source-to-surface distance of 142.5 cm. Field sizes ranged from 1.5 × 1.5 to 10 × 10 cm{sup 2}. Dose scoring was performed using a 3D grid comprising 1 mm{sup 3} voxels. The production thresholds were equivalent for both codes. Results were analyzed based upon a voxel by voxel dose difference between the two codes and also using a volumetric gamma analysis. Results: Comparisons were drawn from central axis depth doses, cross beam profiles, and isodose contours. Both in the presence and absence of a 1.5 T static magnetic field the relative differences in doses scored along the beam central axis were less than 1% for the homogeneous water phantom and all results matched within a maximum of ±2% for heterogeneous phantoms. Volumetric gamma analysis indicated that more than 99% of the examined volume passed gamma criteria of 2%—2 mm (dose difference and distance to agreement, respectively). These criteria were chosen because the minimum primary statistical uncertainty in dose scoring voxels was 0.5%. The presence of the magnetic field affects the dose at the interface depending upon the density of the material on either sides of the interface. This effect varies with the field size. For example, at the water-lung interface a 33.94% increase in dose was observed (relative to the D{sub max}), by both GPUMCD and GEANT4 for the field size of 2 × 2 cm{sup 2} (compared to no B-field case), which increased to 47.83% for the field size of 5 × 5 cm{sup 2} in the presence of the magnetic field. Similarly, at the lung-water interface, the dose decreased by 19.21% (relative to D{sub max}) for a field size of 2 × 2 cm{sup 2} and by 30.01% for 5 × 5 cm{sup 2} field size. For more complex combinations of materials the dose deposition also becomes more complex. Conclusions: The GPUMCD algorithm showed good agreement against GEANT4 both in the presence and absence of a 1.5 T external magnetic field. The application of 1.5 T magnetic field significantly alters the dose at the interfaces by either increasing or decreasing the dose depending upon the density of the material on either side of the interfaces.

61 RADIATION PROTECTION AND DOSIMETRY↗

Are State-Sponsored New Radiation Therapy Facilities Economically Viable in Low- and Middle-Income Countries?

Purpose: The economic viability of establishing a state-funded radiation therapy (RT) infrastructure in low- and middle-income countries (LMICs) in accordance with the World Bank definition has been assessed through computation of a return on investment (ROI). Methods and Materials: Of the 139 LMICs, 100 were evaluated according to their RT facilities, gross national income (GNI) per capita, and employment/population ratio. The assumption was an investment of US$5 million for a basic RT center able to treat 1000 patients annually. The national breakeven points and percentage of ROI (%ROI) were calculated according to the GNI per capita and patient survival rates of 10% to 50% at 2 years. It was assumed that 50% of these patients would be of working age and that, if employed and able to work after treatment, they would contribute to the country's GNI for at least 2 years. The cumulative GNI after attaining the breakeven point until the end of the 15-year lifespan of the teletherapy unit was calculated to estimate the %ROI. The recurring and overhead costs were assumed to vary from 5.5% to 15% of the capital investment. Results: The %ROI was dependent on the GNI per capita, employment/population ratio and 2-year patient survival (all P<.001). Accordingly, none of the low-income countries would attain an ROI. If 50% of the patients survived for 2 years, the %ROI in the lower-middle and upper-middle income countries could range from 0% to 159.9% and 11.2% to 844.7%, respectively. Patient user fees to offset recurring and overhead costs could vary from “nil” to US$750, depending on state subsidies. Conclusions: Countries with a greater GNI per capita, higher employment/population ratio, and better survival could achieve a faster breakeven point, resulting in a higher %ROI. Additional factors such as user fees have also been considered. These can be tailored to the patient's ability to pay to cover the recurring costs. Certain pragmatic steps that could be undertaken to address these issues are discussed in the present study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Lithium Diffusion in Silicon Encapsulated with Graphene

The model of a graphene (Gr) sheet putting on a silicon (Si) substrate is used to simulate the structures of Si microparticles wrapped up in a graphene cage, which may be the anode of lithium-ion batteries (LIBS) to improve the high-volume expansion of Si anode materials. The common low-energy defective graphene (d–Gr) structures of DV5–8–5, DV555–777 and SV are studied and compared with perfect graphene (p–Gr). First-principles calculations are performed to confirm the stable structures before and after Li penetrating through the Gr sheet or graphene/Si-substrate (Gr/Si) slab. The climbing image nudged elastic band (CI-NEB) method is performed to evaluate the diffusion barrier and seek the saddle point. The calculation results reveal that the d–Gr greatly reduces the energy barriers for Li diffusion in Gr or Gr/Si. The energy stability, structural configuration, bond length between the atoms and layer distances of these structures are also discussed in detail.

36 MATERIALS SCIENCE↗

Separation of Zirconium from Zircaloy-2 for Spent Nuclear Fuel Cladding Applications using a Chloride Volatility Process

The United States produces a large amount of cladding material from used nuclear fuel, expected to approach 1,000 MT/year for the next 50 years. The recovery of zirconium from the cladding material would represent a ∼50% savings on the geologic waste disposal requirement, and savings of >$40 M/year due to the cost of hafnium-free zirconium. Previous simulation studies have shown that in the irradiated cladding, the major activation products found are {sup 125}Sb, {sup 60}Co, and {sup 93m}Nb, and the major fission product found is {sup 137}Cs. These radioisotopes make it impossible to treat the cladding as low level waste. In a chlorination method, zirconium cladding reacts with Cl{sub 2} at 350-380 deg. C to produce mainly ZrCl{sub 4}. The zirconium tetrachloride has a relatively low boiling point (sublimes at 330 deg. C) which allows its separation from other products, and so it can be treated as low level waste for disposal or recycling. This chlorination approach has been proposed for the reprocessing of zirconium. However, previous work has observed element impurities (Fe, Sn, Cr, Cs, Sb, and Nb) in the recovered ZrCl{sub 4} meaning that additional steps are necessary in a chlorination process previous to the reduction of ZrCl{sub 4} to the metallic form. The chlorination process for zirconium reprocessing has been highly encouraged as it has proven more efficient than previous mechanical processes, redox processes, and other chemical methods such as iodination. The overall goal of this project is to develop the road map for a chlorination process that will yield high purity zirconium. The current study focuses on the recovery of ZrCl{sub 4} from non-irradiated alloys used as nuclear fuel cladding. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resistive switching phenomena in TiO{sub x} nanoparticle layers for memory applications

Electrical characteristics of a Co/ TiO{sub x}/Co resistive memory device, fabricated by two different methods, are reported. In addition to crystalline TiO{sub 2} layers fabricated via conventional atomic layer deposition (ALD), an alternative method has been examined, where TiO{sub x} nanoparticle layers were fabricated via sol-gel. The different devices have shown different hysteresis loops with a unique crossing point for the sol-gel devices. A simple qualitative model is introduced to describe the different current-voltage behaviours by suggesting only one active metal-oxide interface for the ALD devices and two active metal-oxide interfaces for the sol-gel devices. Furthermore, we show that the resistive switching behaviour could be easily tuned by proper interface engineering and that despite having a similar active material, different fabrication methods can lead to dissimilar resistive switching properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Conduction of the three-dimensional model of a composite with structural anisotropy

The electric conduction of the model of a structurally anisotropic composite that represents an isotropic matrix with disk-shaped inclusions (oblate spheroids) is analytically studied. The disks have the same orientation and their centers are randomly distributed in the composite volume. The cases of dielectric and ideally conducting inclusions are considered. The conduction of the model in a broad concentration range is described by the approximate effective medium method. Conduction in the critical region (in the vicinity of the metal–dielectric phase transition point) is studied using the similarity hypothesis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The hunt for LaFeSbO: Synthesis of La{sub 2}SbO{sub 2} and a case of mistaken identity

The phase La{sub 2}SbO{sub 2} has been identified and characterized in the course of our efforts to realize LaFeSbO, a composition of great interest to the superconductor community. The compound La{sub 2}SbO{sub 2} is a tetragonal layered oxypnictide containing La{sub 2}O{sub 2} layers similar to LaMPnO compositions (where M=transition metal, Pn=pnictide) separated by pnictide anion layers. In order to better understand why LaFeSbO has remained elusive, density functional theory calculations have been used to determine the ground state heats of formation for LaFeSbO, La{sub 2}SbO{sub 2}, and other competing phases within the La-Fe-Sb-O system, as well as the phonon spectrum for LaFeSbO. These efforts suggest that LaFeSbO is a potentially metastable composition. - Graphical abstract: The layered oxypnictide compounds La{sub 2}SbO{sub 2} and La{sub 1.9}Sr{sub 0.1}SbO{sub 2} have been synthesized and investigated. Both crystallize in a ThCr{sub 2}Si{sub 2} type configuration and are semiconducting. Stability of the unreported compound LaFeSbO has been investigated using density functional theory. A case of mistaken identity in the literature regarding the composition LaNiBiO is addressed. Highlights: Black-Right-Pointing-Pointer The composition La{sub 2}SbO{sub 2} has been identified. Black-Right-Pointing-Pointer La{sub 2}SbO{sub 2} belongs to an unusual group of materials containing Pn{sup 2-} anions. Black-Right-Pointing-Pointer La{sub 2}SbO{sub 2} and La{sub 1.9}Sr{sub 0.1}SbO{sub 2} are both found to be semiconducting. Black-Right-Pointing-Pointer DFT has been used to calculate heats of formation within the La-Fe-Sb-O system. Black-Right-Pointing-Pointer The phonon spectrum for LaFeSbO reveals no unstable lattice mode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of the pore size in multi-walled carbon nanotubes on the hydrogen storage behaviors

Activated multi-walled carbon nanotubes (A-MWCNTs) were prepared using a chemical activation method to obtain well-developed pore structures for use as hydrogen storage materials. The microstructure and crystallinity of the A-MWCNTs were evaluated by X-ray diffraction and Fourier transform Raman spectroscopy. The textural properties of the A-MWCNTs were investigated by nitrogen gas sorption analysis at 77 K. The hydrogen storage capacity of the A-MWCNTs was evaluated at 77 K and 1 bar. The results showed that the specific surface area of the MWCNTs increased from 327 to 495 m{sup 2}/g as the activation temperature was increased. The highest hydrogen storage capacity was observed in the A-MWCNTs sample activated at 900 Degree-Sign C (0.54 wt%). This was attributed to it having the narrowest microporosity, which is a factor closely related to the hydrogen storage capacity. This shows that the hydrogen storage behaviors depend on the pore volume. Although a high pore volume is desirable for hydrogen storage, it is also severely affected if the pore size in the A-MWCNTs for the hydrogen molecules is suitable for creating the activation process. Highlights: Black-Right-Pointing-Pointer The AT-800 and AT-900 samples were prepared by a chemical activation method at activation temperature of 800 and 900 Degree-Sign C, respectively. Black-Right-Pointing-Pointer The AT-900 sample has the narrowest peak in comparison with the AT-800 sample, resulting from the overlap of the two peaks (Peak I and Peak II). Black-Right-Pointing-Pointer This overlapping effect is due to the newly created micropores or shrinkages of pores in Peak II. So, these determining characteristics are essential for designing materials that are suitable for molecular hydrogen storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interfractional Reproducibility of Lung Tumor Location Using Various Methods of Respiratory Motion Mitigation

Purpose: To determine interfractional reproducibility of the location of lung tumors using respiratory motion mitigation. Methods and Materials: Free-breathing four-dimensional computed tomography (CT) data sets and CT data sets during breath hold were acquired weekly for 17 patients undergoing treatment for non-small-cell lung cancer. Distances between the center of the gross tumor volume (GTV) and a reproducible bony reference point under conditions of breath hold on end inspiration (EI) and end expiration (EE) and during free breathing on the 0% phase (corresponding to EI) and 50% phase (corresponding to EE) were analyzed for interfractional reproducibility. Systematic uncertainties in tumor location were determined as the difference in distance between the GTV center on the first CT data set and the mean location of GTV centers on the subsequent data sets. Random uncertainties in tumor location were determined as the standard deviation of the distances between the GTV centers and the bony reference points. Margins to account for systematic and random interfractional variations were estimated based on these uncertainties. Results: Mean values of interfractional setup uncertainties were as follows: systematic uncertainties-EI, 0.3 cm; EE, 0.2 cm; 0% phase, 0.3 cm; and 50% phase, 0.3 cm; and random uncertainties-EI, 0.3 cm; EE, 0.3 cm; 0% phase, 0.3 cm; and 50% phase, 0.3 cm. There does not appear to be any correlation between uncertainties and GTV size, but there appears to be a weak positive correlation between uncertainties and the magnitude of GTV excursion. Conclusions: Voluntary breath hold and gating on either EI or EE appear to be equally reliable methods of ensuring the reproducibility of lung tumor position. We recommend setup margins of 0.3 cm if using cone-beam CT or kilovoltage X-ray with fiducials and aligning directly to the tumor and 0.8 cm when aligning to a nearby bony surrogate using cone-beam CT or kilovoltage X-ray.

62 RADIOLOGY AND NUCLEAR MEDICINE↗