Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

IN SITU ELLIPSOMETRY FOR SHOCK COMPRESSION MEASUREMENTS

Knowledge about the optical properties of materials at high pressure and high temperature is needed for EOS research. Ellipsometry measures the change in the polarization of a probe beam reflected from a surface. From the change in polarization, the real and imaginary parts of the time dependent complex index of refraction can be extracted. From the measured optical properties, fundamental physical properties of the material, such as emissivity, phase transitions, and electrical conductivity can be extracted. A dynamic ellipsometry measurement system with nanosecond resolution was built in order to measure all four stocks parameters. Gas gun was used to accelerate the impact flyer. Our experiments concentrated on the optical properties of 1020 steel targets with impact pressure range of 40-250 kbar. Although there are intrinsic difficulties with dynamic ellipsometric measurements, distinct changes were observed for 1020 steel under shock compression larger than 130 kbar, the alpha->epsilon phase transition.

36 MATERIALS SCIENCE↗

Mechanism of plasma-induced damage to low-k SiOCH films during plasma ashing of organic resists

Plasma-induced damage to porous SiOCH (p-SiOCH) films during organic resist film ashing using dual-frequency capacitively coupled O{sub 2} plasmas was investigated using the pallet for plasma evaluation method developed by our group. The damage was characterized by ellipsometry and Fourier-transform infrared spectroscopy. Individual and synergetic damage associated with vacuum ultraviolet (VUV) and UV radiation, radicals, and ions in the O{sub 2} plasma were clarified. It was found that the damage was caused not only by radicals but also by synergetic reactions of radicals with VUV and UV radiation emitted by the plasmas. It is noteworthy that the damage induced by plasma exposure without ion bombardment was larger than the damage with ion bombardment. These results differed from those obtained using an H{sub 2}/N{sub 2} plasma for resist ashing. Finally, the mechanism of damage to p-SiOCH caused by O{sub 2} and H{sub 2}/N{sub 2} plasma ashing of organic resist films is discussed. These results are very important in understanding the mechanism of plasma-induced damage to p-SiOCH films.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A strong magneto-optical activity in rare-earth La{sup 3+} substituted M-type strontium ferrites

M-type strontium ferrites with substitution of Sr{sup 2+} by rare-earth La{sup 3+} were prepared by conventional ceramic technology. The structure, magnetic properties, and magneto-optical Kerr activity of Sr{sub 1-x}La{sub x}Fe{sub 12}O{sub 19} (x = 0, 0.05, 0.10, 0.15, 0.20) were investigated by x-ray diffraction (XRD), vibrating sample magnetometer (VSM), and magneto-optical ellipsometry, respectively. X-ray diffraction showed that the samples sintered at 1290 deg. C for 3 h were single M-type hexagonal ferrites. The magnetic properties were remarkably changed due to the valence change of Fe ions induced by the substitution of La ions. Most significantly, an important magneto-optical activity was induced in the La{sup 3+} substituted M-type strontium ferrites around 3 eV.

36 MATERIALS SCIENCE↗

Laser mass-spectrometry for online diagnosis of reactive plasmas with many species

The purpose of this study is to design a diagnostic system for reactive plasma environment by combining molecular-beam time-of-flight (TOF) mass spectroscopy with laser spectroscopy technique. The combination of TOF mass spectrometers and pulsed lasers is favorable in the diagnosis of intermediate species distribution since they allow the simultaneous but separate recording of the spectra of different species. In the plasma system, the intermediate species in electronic ground state or low lying excited state is pumped to higher energy level with resonant laser excitation, and then, the ionization with a second laser system is possible which can readily be detected by the TOF analyzer. The ionization itself is only used as a detection mechanism for the observation of the excitation of these states. In this manner, the population distribution of intermediate species can be determined with state-selective and mass-selective feature. Also, in this article, a flexible data acquisition and automatic control system based on LABVIEW was designed to integrate all the stand-alone measurement instruments including a TOF spectrometer, a laser system, a high performance oscilloscope, and a digital delay generator into a single personal computer-based control unit. Moreover, a virtual Boxcar integrator with hundreds of channels has been developed to enhance the signal while filtering out the random noises. Finally, the many potentials of this technique in the application of plasma diagnosis will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparation of anti-adhesion surfaces on aluminium substrates of rubber plastic moulds using a coupling method of liquid plasma and electrochemical machining

Hard anti-adhesion surfaces, with low roughness and wear resistance, on aluminium substrates of rubber plastic moulds were fabricated via a new coupling method of liquid plasma and electrochemical machining. With the aid of liquid plasma thermal polishing and electrochemical anodic dissolution, micro/nano-scale binary structures were prepared as the base of the anti-adhesion surfaces. The anti-adhesion behaviours of the resulting aluminium surfaces were analysed by a surface roughness measuring instrument, a scanning electron microscope (SEM), a Fourier-transform infrared spectrophotometer (FTIR), an X-ray diffractometer (XRD), an optical contact angle meter, a digital Vickers micro-hardness (Hv) tester, and electronic universal testing. The results show that, after the liquid plasma and electrochemical machining, micro/nano-scale binary structures composed of micro-scale pits and nano-scale elongated boss structures were present on the sample surfaces. As a result, the anti-adhesion surfaces fabricated by the above coupling method have good anti-adhesion properties, better wear resistance and lower roughness.

36 MATERIALS SCIENCE↗

Measurement of neutron capture cross section of Li-7 at J-PARC / MLF / ANNRI

We have measured the {sup 7}Li(n,γ){sup 8}Li reaction at Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) installed at the Material and Life science experimental Facility in the Japan Proton Accelerator Research Complex (J-PARC / MLF). In this experiment, we used intense pulsed neutron beam provided by J-PARC / MLF and high performance Ge spectrometer, which is one of the main detectors of the ANNRI. We clearly detected γ rays from the {sup 7}Li(n,γ){sup 8}Li reaction with sufficient signal-to-noise ratio.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Open ISEmeter: An open hardware high-impedance interface for potentiometric detection

In this work, a new open hardware interface based on Arduino to read electromotive force (emf) from potentiometric detectors is presented. The interface has been fully designed with the open code philosophy and all documentation will be accessible on web. The paper describes a comprehensive project including the electronic design, the firmware loaded on Arduino, and the Java-coded graphical user interface to load data in a computer (PC or Mac) for processing. The prototype was tested by measuring the calibration curve of a detector. As detection element, an active poly(vinyl chloride)-based membrane was used, doped with cetyltrimethylammonium dodecylsulphate (CTA{sup +}-DS{sup −}). The experimental measures of emf indicate Nernstian behaviour with the CTA{sup +} content of test solutions, as it was described in the literature, proving the validity of the developed prototype. A comparative analysis of performance was made by using the same chemical detector but changing the measurement instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise mitigation methods for ion detectors operating with a direct view of high temperature plasmas

In this work, we have developed an ion current measurement instrument with a direct view of a plasma that reduces the particle and radiation-induced noise current it detects by over three orders of magnitude, from tens of microamps to tens of nanoamps. This is accomplished using electric fields, magnetic fields, and physical shielding that limit the flux of particles and radiation into the instrument and suppress the secondary electrons produced within it by particle and radiation impact. Operation of this detector in various configurations, without an ion beam, has allowed identification of the sources of noise current. In our experimental setup, the largest noise contributors were found to be plasma ions and photoelectric emission due to UV radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics-based compact modeling of electro-thermal memristors: Negative differential resistance, local activity, and non-local dynamical bifurcations

Leon Chua's Local Activity theory quantitatively relates the compact model of an isolated nonlinear circuit element, such as a memristor, to its potential for desired dynamical behaviors when externally coupled to passive elements in a circuit. However, the theory's use has often been limited to potentially unphysical toy models and analyses of small-signal linear circuits containing pseudo-elements (resistors, capacitors, and inductors), which provide little insight into required physical, material, and device properties. Furthermore, the Local Activity concept relies on a local analysis and must be complemented by examining dynamical behavior far away from the steady-states of a circuit. In this work, we review and study a class of generic and extended one-dimensional electro-thermal memristors (i.e., temperature is the sole state variable), re-framing the analysis in terms of physically motivated definitions and visualizations to derive intuitive compact models and simulate their dynamical behavior in terms of experimentally measurable properties, such as electrical and thermal conductance and capacitance and their derivatives with respect to voltage and temperature. Within this unified framework, we connect steady-state phenomena, such as negative differential resistance, and dynamical behaviors, such as instability, oscillations, and bifurcations, through a set of dimensionless nonlinearity parameters. In particular, we reveal that the reactance associated with electro-thermal memristors is the result of a phase shift between oscillating current and voltage induced by the dynamical delay and coupling between the electrical and thermal variables. We thus, demonstrate both the utility and limitations of local analyses to understand non-local dynamical behavior. Critically for future experimentation, the analyses show that external coupling of a memristor to impedances within modern sourcing and measurement instruments can dominate the response of the total circuit, making it impossible to characterize the response of an uncoupled circuit element for which a compact model is desired. However, these effects can be minimized by proper understanding of the Local Activity theory to design and utilize purpose-built instruments.

Brown, Timothy D. (ORCID:0000000347068355)↗

Contactless diagnostics of biophysical parameters of skin and blood on the basis of approximating functions for radiation fluxes scattered by skin

Approximating expressions are derived to calculate spectral and spatial characteristics of diffuse reflection of light from a two-layer medium mimicking human skin. The effectiveness of the use of these expressions in the optical diagnosis of skin biophysical parameters (tissue scattering parameters, concentration of melanin in the epidermis, concentration of total haemoglobin and bilirubin in the tissues of the dermis) and content of haemoglobin derivatives in blood (oxy-, deoxy-, met-, carboxy- and sulfhaemoglobin) is analysed numerically. The methods are proposed to determine in realtime these parameters without contact of the measuring instrument with the patient's body. (biophotonics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PROPERTIES OF A POLAR CORONAL HOLE DURING THE SOLAR MINIMUM IN 2007

We report measurements of a polar coronal hole during the recent solar minimum using the Extreme Ultraviolet Imaging Spectrometer on Hinode. Five observations are analyzed that span the polar coronal hole from the central meridian to the boundary with the quiet-Sun corona. We study the observations above the solar limb in the height range of 1.03-1.20 R{sub sun}. The electron temperature T{sub e} and emission measure (EM) are found using a geometric mean emission measure method. The EM derived from the elements Fe, Si, S, and Al are compared in order to measure relative coronal-to-photospheric abundance enhancement factors. We also studied the ion temperature T{sub i} and the non-thermal velocity v{sub nt} using the line profiles. All these measurements are compared to polar coronal hole observations from the previous (1996-1997) solar minimum and to model predictions for relative abundances. There are many similarities in the physical properties of the polar coronal holes between the two minima at these low heights. We find that the electron density, T{sub e}, and T{sub i} are comparable in both minima. T{sub e} shows a comparable gradient with height. Both minima show a decreasing T{sub i} with increasing charge-to-mass ratio q/M. A previously observed upturn of T{sub i} for ions above q/M>0.25 was not found here. We also compared relative coronal-to-photospheric elemental abundance enhancement factors for a number of elements. These ratios were {approx}1 for both the low first ionization potential (FIP) elements Si and Al and the marginally high FIP element S relative to the low FIP element Fe, as is expected based on earlier observations and models for a polar coronal hole. These results are consistent with no FIP effect in a polar coronal hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Autonomous x-ray scattering

Autonomous experimentation (AE) is an emerging paradigm that seeks to automate the entire workflow of an experiment, including—crucially—the decision-making step. Beyond mere automation and efficiency, AE aims to liberate scientists to tackle more challenging and complex problems. We describe our recent progress in the application of this concept at synchrotron x-ray scattering beamlines. We automate the measurement instrument, data analysis, and decision-making, and couple them into an autonomous loop. We exploit Gaussian process modeling to compute a surrogate model and associated uncertainty for the experimental problem, and define an objective function exploiting these. We provide example applications of AE to x-ray scattering, including imaging of samples, exploration of physical spaces through combinatorial methods, and coupling to in situ processing platforms These uses demonstrate how autonomous x-ray scattering can enhance efficiency, and discover new materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

COSMIC ORIGINS SPECTROGRAPH OBSERVATIONS OF TRANSLUCENT CLOUDS: Cyg OB2 8A

Data from the Cosmic Origins Spectrograph (COS) are presented for the first highly reddened target (Cyg OB2 8A) under the COS Science Team's guaranteed time allocation. Column densities of ionic, atomic, and molecular species are reported and implications are discussed. Data from Cyg OB2 8A demonstrate the ability to analyze highly reddened interstellar sight lines with the COS that were unavailable to previous UV instruments. Measured column densities indicate that the Cyg OB2 8A line of sight contains multiple diffuse clouds rather than a dominant translucent cloud.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrared spectroscopy of nearby radio active early-type galaxies - II: spectral atlas

ABSTRACT We present a near-infrared spectroscopic atlas of nearby, bright early-type galaxies with radio emission, containing 163 galaxies observed by the Palomar 200″ TripleSpec instrument, measuring the emission line fluxes for H, He, [Fe ii], and H2 and determined the nuclear excitation mechanisms. By stacking spectra, we deduced the H2 excitation temperature (1957 ± 182 K) and dominant excitation mechanism (thermal and shock heating combined) from the K-band emission line sequence. Stacking also produces an ‘average’ spectrum of absorption features and spectral indices from the literature; the CO12 absorption line index versus J − K colour shows a trend of stronger nuclear activity producing a weaker CO12 index and a redder (flatter) continuum. The correlations between the radio and the emission-line luminosities finds a trend with radio power; however, the large scatter in the upper limits shows that the two are not directly coupled and the duty cycles of SF and AGN activity are not synchronized.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum metrology with imperfect states and detectors

Quantum enhancements of precision in metrology can be compromised by system imperfections. These may be mitigated by appropriate optimization of the input state to render it robust, at the expense of making the state difficult to prepare. In this paper, we identify the major sources of imperfection of an optical sensor: input state preparation inefficiency, sensor losses, and detector inefficiency. The second of these has received much attention; we show that it is the least damaging to surpassing the standard quantum limit in a optical interferometric sensor. Further, we show that photonic states that can be prepared in the laboratory using feasible resources allow a measurement strategy using photon-number-resolving detectors that not only attain the Heisenberg limit for phase estimation in the absence of losses, but also deliver close to the maximum possible precision in realistic scenarios including losses and inefficiencies. In particular, we give bounds for the tradeoff between the three sources of imperfection that will allow true quantum-enhanced optical metrology

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the W{sup +}W{sup -} Production Cross Section and Search for Anomalous WW{gamma} and WWZ Couplings in pp Collisions at {radical}(s)=1.96 TeV

This Letter describes the current most precise measurement of the W boson pair production cross section and most sensitive test of anomalous WW{gamma} and WWZ couplings in pp collisions at a center-of-mass energy of 1.96 TeV. The WW candidates are reconstructed from decays containing two charged leptons and two neutrinos. Using data collected by the CDF II detector from 3.6 fb{sup -1} of integrated luminosity, a total of 654 candidate events are observed with an expected background of 320{+-}47 events. The measured cross section is {sigma}(pp{yields}W{sup +}W{sup -}+X)=12.1{+-}0.9(stat){sub -1.4}{sup +1.6}(syst) pb, which is in good agreement with the standard model prediction. The same data sample is used to place constraints on anomalous WW{gamma} and WWZ couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Critical-Point Boundary for the Nuclear Quantum Phase Transition Near A=100 from Mass Measurements of {sup 96,97}Kr

Mass measurements of {sup 96,97}Kr using the ISOLTRAP Penning-trap spectrometer at CERN-ISOLDE are reported, extending the mass surface beyond N=60 for Z=36. These new results show behavior in sharp contrast to the heavier neighbors where a sudden and intense deformation is present. We interpret this as the establishment of a nuclear quantum phase transition critical-point boundary. The new masses confirm findings from nuclear mean-square charge-radius measurements up to N=60 but are at variance with conclusions from recent gamma-ray spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗