Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microfluidic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Development of a Point of Care Technology for Military Medical Applications in Austere Environments

NASA, Lawrence Livermore National Laboratory (LLNL) and the Department of Defense (DoD) share a common interest in compact medical diagnostic technologies—also known as “point of care testing” (POCT) technologies. For NASA, the need is to take care of astronauts on deep space missions. For LLNL, the focus is on technologies needed to support homeland security applications. For DoD, the need is to support warfighters in military theaters of operation, especially for prolonged field care and en route care. A recently patented technology, “Portable Medical Diagnosis Instrument” (U.S. Patent 9824870), co-invented by NASA and LLNL, is being developed further in a partnership between NASA, LLNL and Travis Air Force Base, with a focus on military applications. This instrument, the NASA-LLNL Medical Tricorder, can be used for a wide range of clinical samples including breath, saliva and blood. One component of the Tricorder is the NASA E-Nose, a carbon nanotube-based chemical sensor, integrated into a hand-held smart phone, that can detect and measure “breath biomarkers” in the gas phase of exhaled breath. The response of the NASA E-Nose is rapid, which makes it possible to detect various gas-phase substances in real time. The NASA E-Nose, with modification, can also be used for breath condensate analysis. Another component of the Tricorder is a miniaturized microfluidic analyzer, under development by LLNL, that does not require any pumps. The microfluidic analyzer can detect and measure biomarkers in liquid samples, such as blood, saliva and breath condensate. This microfluidic system requires small quantities of liquid sample and can perform analysis very rapidly (seconds to minutes), which makes it possible to detect relevant biomarkers in near real time in the field. The Clinical Investigation Facility (CIF) at Travis Air Force Base is currently conducting research with the goal to develop improved field-able technologies and procedures for the emergency response to life threatening injuries soldiers may receive in theater. This work includes experimental large animal systems and comprehensive collection of clinical specimens and physiological data. NASA and LLNL are partnering with Travis to test and further develop the Tricorder technology for high priority military applications, initially focused on lung injury models and traumatic brain injury.

Loftus, David J.↗

Autonomous Measurement of Electrochemical Redox Couples for In-Situ Characterization of Enceladus Plume Samples

A 3D-printed microfluidic electrochemical cell with integrated electrodes was developed to demonstrate autonomous in-situ electrochemical characterization of terrestrial seawater samples. The system is designed to extend the capabilities of the 2008 Phoenix Lander’s Wet Chemistry Laboratory (WCL) that analyzed the soluble chemistry of the Martian soil, by miniaturizing its fluidic architecture for analysis of µL-volume samples as expected from an Enceladus fly-by mission. The microfluidic device has a total fluid volume of 48 µL and includes dual channels each populated with 7 electrodes. Measurement of pH was measured using an iridium oxide electrode. Cyclic voltammetry with Au, Pt, and glassy carbon working electrodes was used to measure redox couples in synthetic seawater that contained inorganic and bio-organic molecules. Glassy carbon was found to have minimal risk of interference from constituents of synthetic seawater when measuring molecular organic redox species; however, care must be used to prevent interference due to potential oxidation or dissolution in the case of Au working electrodes. A completely autonomous end-to-end run including sample delivery was performed, to demonstrate the feasibility of microfluidic-based cyclic voltammetry measurements for in-situ characterization of redox couples in Ocean World samples.

Planetary Instruments↗

Probing Aqueous Surfaces by ToF-SIMS

We report the first observations of aqueous surfaces by a time-of-flight secondary ion mass spectrometer (ToF-SIMS) via a self-contained microfluidic module compatible in vacuum. The interface uses a microfluidic channel with a 3 {micro}m diameter window into the flowing fluid beneath it. This window supports the liquid against the vacuum by the liquid's surface tension and limits the high-density vapor region traversed by the probe beams to only a few micrometers. We demonstrate detections of aqueous surfaces such as deuterium water and sodium iodide (NaI) solution through the small aperture by ToF-SIMS. Even more, molecular signals (M-H-) of glutamic acid (C5H8NO4-) are observed. ToF-SIMS coupled with the novel interface provides a molecular recognition capability, making it a great choice to detect short-lifetime reaction intermediates in aqueous solutions. This novel microfluidic interface makes multimodal vacuum based analysis of liquid surface possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Membraneless seawater desalination

Disclosed are microfluidic devices and systems for the desalination of water. The devices and systems can include an electrode configured to generate an electric field gradient in proximity to an intersection formed by the divergence of two microfluidic channels from an inlet channel. Under an applied bias and in the presence of a pressure driven flow of saltwater, the electric field gradient can preferentially direct ions in saltwater into one of the diverging microfluidic channels, while desalted water flows into second diverging channel. Also provided are methods of using the devices and systems described herein to decrease the salinity of water.

42 ENGINEERING↗

Separation of Yeast Cells from MS2 Viruses Using Acoustic Radiation Force

We report a rapid and robust separation of Saccharomyces cerevisiae and MS2 bacteriophage using acoustic focusing in a microfluidic device. A piezoelectric transducer (PZT) generates acoustic standing waves in the microchannel. These standing waves induce acoustic radiation force fields that direct microparticles towards the nodes (i.e., pressure minima) or the anti-nodes (i.e., pressure maxima) of the standing waves depending on the relative compressidensity between the particle and the suspending liquid.[1] For particles larger than 2 {micro}m, the transverse velocities generated by these force fields enable continuous, high throughput separation. Extensive work in the last decade [2-4] has demonstrated acoustic focusing for manipulating microparticles or biological samples in microfluidic devices. This prior work has primarily focused on experimental realization of acoustic focusing without modeling or with limited one-dimensional modeling estimates. We recently developed a finite element modeling tool to predict the two-dimensional acoustic radiation force field perpendicular to the flow direction in microfluidic devices.[1] Here we compare results from this model with experimental parametric studies including variations of the PZT driving frequencies and voltages as well as various particle sizes and compressidensities. These experimental parametric studies also provide insight into the development of an adjustable 'virtual' pore-size filter as well as optimal operating conditions for various microparticle sizes. Figure 1 shows a typical experimental acoustic focusing result for microparticles (diameter = 2.0 {micro}m) in a 500 {micro}m wide by 200 {micro}m deep microchannel. In this case, the PZT driving frequency and voltage are, respectively, 1.459 MHz and 6.6 V. The microparticles tightly focus (full width half maximum (FWHM) {approx}30 {micro}m) less than 30 s after the initiation of the acoustic field. We simulated the same geometry and operating conditions for comparison. The surface plot in Figure 2 illustrates the two-dimensional pressure field orthogonal to the flow direction (x-direction) from the simulation. The superimposed vector plot shows the acoustic radiation force in this plane. The dark regions and the light regions respectively represent the nodes and anti-nodes of the acoustic pressure field. The corresponding force field predicts acoustic focusing at the center of the microchannel, which is confirmed by the experimental results shown in Figure 1. We demonstrated the separation of Saccharomyces cerevisiae (typical cell size of 4-6 {micro}m depending on the cell growth stage, measured using a Coulter counter) and MS2 bacteriophage (typical diameter {approx}30 nm [5]) using acoustic focusing (Figure 3). A mixture of S. cerevisiae and MS2 labeled with Ribogreen was prepared and injected into one inlet of the microchip (i.e., half of the microchannel was filled with the sample). We varied driving voltages from 1.96 to 4.76 V, while fixing the driving frequency at 1.459 MHz and flow rate at 20 {micro}l/min. The acoustic radiation force did not affect the MS2 viruses, and their concentration profile remained unchanged. Increased driving voltages enhanced the acoustic focusing of the yeast cells thereby achieving good separation. We are able to achieve yields of > 80% and sample purities of > 90% in this continuous-flow sample preparation device.

42 ENGINEERING↗

Adjustable virtual pore-size filter for automated sample preparation using acoustic radiation force

We present a rapid and robust size-based separation method for high throughput microfluidic devices using acoustic radiation force. We developed a finite element modeling tool to predict the two-dimensional acoustic radiation force field perpendicular to the flow direction in microfluidic devices. Here we compare the results from this model with experimental parametric studies including variations of the PZT driving frequencies and voltages as well as various particle sizes and compressidensities. These experimental parametric studies also provide insight into the development of an adjustable 'virtual' pore-size filter as well as optimal operating conditions for various microparticle sizes. We demonstrated the separation of Saccharomyces cerevisiae and MS2 bacteriophage using acoustic focusing. The acoustic radiation force did not affect the MS2 viruses, and their concentration profile remained unchanged. With optimized design of our microfluidic flow system we were able to achieve yields of > 90% for the MS2 with > 80% of the S. cerevisiae being removed in this continuous-flow sample preparation device.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical Techniques

Sensitive and selective detection techniques are of crucial importance for capillary electrophoresis (CE), microfluidic chips, and other microfluidic systems. Electrochemical detectors have attracted considerable interest for microfluidic systems with features that include high sensitivity, inherent miniaturization of both the detection and control instrumentation, low cost and power demands, and high compatibility with microfabrication technology. The commonly used electrochemical detectors can be classified into three general modes: conductimetry, potentiometry, and amperometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetohydrodynamic pump with a system for promoting flow of fluid in one direction

A magnetohydrodynamic pump for pumping a fluid. The pump includes a microfluidic channel for channeling the fluid, a MHD electrode/magnet system operatively connected to the microfluidic channel, and a system for promoting flow of the fluid in one direction in the microfluidic channel. The pump has uses in the medical and biotechnology industries for blood-cell-separation equipment, biochemical assays, chemical synthesis, genetic analysis, drug screening, an array of antigen-antibody reactions, combinatorial chemistry, drug testing, medical and biological diagnostics, and combinatorial chemistry. The pump also has uses in electrochromatography, surface micromachining, laser ablation, inkjet printers, and mechanical micromilling.

42 ENGINEERING↗

In situ SEM and ToF-SIMS analysis of IgG conjugated gold nanoparticles at aqueous surfaces

In this study, we report new results of in situ study of 5 nm goat anti-mouse IgG gold nanoparticles in a novel portable vacuum compatible microfluidic device using scanning electron microscope (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The unique feature of the liquid flow cell is that the detection window is open to the vacuum allowing direct probing of the liquid surface. The flow cell is composed of a silicon nitride (SiN) membrane and polydimethylsiloxane (PDMS), and it is fully compatible with vacuum operations for surface analysis. The aperture can be drilled through the 100 nm SiN membrane using a focused ion beam. Characteristic signals of the conjugated gold nanoparticles were successfully observed through the aperture by both energy-dispersive X-ray spectroscopy (EDX) in SEM and ToF-SIMS. Comparison was also made among wet samples, dry samples, and liquid sample in the flow cell using SEM/EDX. Stronger gold signal can be observed in our novel portable device by SEM/EDX compared with the wet or dry samples, respectively. Our results indicate that analyses of the nanoparticle components are better made in their native liquid environment. This is made possible using our unique microfluidic flow cell.

aqueous surface↗

Development of field-based separations for the rapid identification of uranium and plutonium

The development of rapid, radioanalytical techniques to separate uranium and plutonium from complex, field samples are needed for the timely and accurate determination of nuclear material origin, and processing activities. Widespread use of nuclear power and technology in the world has increased demands on analytical laboratories from the monitoring of numerous low-level, environmental samples with variable compositions. Environmental sampling has proven to be one of the strongest technical measures for detecting nuclear material and activities. With the increase in sampling demands, new technologies must offer improvements such as automation, high throughput, reproducible chemical separations, short analysis times, and reduced costs to be effective. We have been developing a portable, separations system for uranium (U) and plutonium (Pu) separations based upon selective extraction of target elements using an extraction chromatographic resin which would allow for simple and fast identifcation when coupled with the appropriate sample digestor and detection systems. The microfluidic design minimizes elution volumes and concentrates the elements of interest in a purified stream. Flowsheet development and testing was demonstrated on a single, micro-column system with an acidified, iron, uranium, and plutonium nitrate stream. The recovery of Pu was optimized by examining various reducing agents at different concentrations for rapid, quantitative recovery from the flow-through design. Quantitative recovery and high selectivity of U and Pu was achieved in the appropriate stripping stages and provided purified and concentrated U and Pu streams. The microfluidic system suggests automation in a small, footprint unit while exploiting the in-line processing of extraction chromatographic resins as the primary means of concentrating the radionuclides from the raw acidic feed and separating the elements into purified streams.

Extraction Chromatography↗

Dynamic fatigue measurement of human erythrocytes using dielectrophoresis

Erythrocytes must undergo severe deformation to pass through narrow capillaries and submicronic splenic slits for several hundred thousand times in their normal lifespan. Studies of erythrocyte biomechanics have been mainly focused on cell deformability and rheology measured from a single application of stress and mostly under a static or quasi-static state using classical biomechanical techniques, such as optical tweezers and micropipette aspiration. Dynamic behavior of erythrocytes in response to cyclic stresses that contributes to the membrane failure in blood circulation is not fully understood. This article presents a new experimental method for dynamic fatigue analysis of erythrocytes, using amplitude modulated electrokinetic force field in a microfluidic platform. Here, we demonstrate the capability of this new technique using a low cycle fatigue analysis of normal human erythrocytes and ATP-depleted erythrocytes. Cyclic tensile stresses are generated to induce repeated uniaxial stretching and extensional recovery of single erythrocytes. Results of morphological and biomechanical parameters of individually tracked erythrocytes show strong correlations with the number of the loading cycles. Under a same strength of electric field, after 180 stress cycles, for normal erythrocytes, maximum stretch ratio decreases from 3.80 to 2.86, characteristic time of cellular extensional recovery increases from 0.16 s to 0.37 s, membrane shear viscosity increases from 1.0 (µN/m) s to 1.6 (µN/m) s. Membrane deformation in a small number of erythrocytes becomes irreversible after large deformation for about 200 cyclic loads. ATP-depleted cells show similar trends in decreased deformation and increased characteristic time with the loading cycles. Lastly, these results show proof of concept of the new microfluidics technique for dynamic fatigue analysis of human erythrocytes.

60 APPLIED LIFE SCIENCES↗

Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries

This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. Further, a custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10–40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r 2 ≥ 0.95).

42 ENGINEERING↗

Review of methods to probe single cell metabolism and bioenergetics

The sampling and manipulation of cells down to the individual has been of substantial interest since the very beginning of Life Sciences. Herein, our objective is to highlight the most recent developments in single cell manipulation, as well as pioneering ones. First, flow-through methods will be discussed, namely methods in which the single cells flow continuously in an ordered manner during their analysis. This section will be followed by confinement techniques that enable cell isolation and confinement in one, two- or three-dimensions. Flow cytometry and droplet microfluidics are the two most common methods of flow-through analysis. While both are high-throughput techniques, their difference lays in the fact that the droplet encapsulated cells experience a restricted and personal microenvironment, while in flow cytometry cells experience similar nutrient and stimuli initial concentrations. These methods are rather well established; however, they recently enabled immense strides in single cell phenotypic analysis, namely the identification and analysis of metabolically distinct individuals from an isogenic population using both droplet microfluidics and flow cytometry.

59 BASIC BIOLOGICAL SCIENCES↗

Worming Their Way into Shape: Toroidal Formations in Micellar Solutions

We report the formation of nanostructured toroidal micellar bundles (nTMB) from a semidilute wormlike micellar solution, evidenced by both cryogenicelectron microscopy and transmission electron microscopy images. Our strategy for creating nTMB involves a two-step protocol consisting of a simple prestraining process followed by flow through a microfluidic device containing an array of microposts, producing strain rates in the wormlike micelles on the order of 105 s^1. In combination with microfluidic confinement, these unusually large strain rates allow for the formation of stable nTMB. Electron microscopy images reveal a variety of nTMB morphologies and provide the size distribution of the nTMB. Small-angle neutron scattering indicates the underlying microstructural transition from wormlike micelles to nTMB. We also show that other flow-induced approaches such as sonication can induce and control the emergence of onion-like and nTMB structures, which may provide a useful tool for nanotemplating.

Environmental Molecular Sciences Laboratory↗

An optimized microfabricated platform for the optical generation and detection of hyperpolarized 129 Xe

Low thermal-equilibrium nuclear spin polarizations and the need for sophisticated instrumentation render conventional nuclear magnetic resonance (NMR) spectroscopy and imaging (MRI) incompatible with small-scale microfluidic devices. Hyperpolarized 129 Xe gas has found use in the study of many materials but has required very large and expensive instrumentation. Recently a microfabricated device with modest instrumentation demonstrated all-optical hyperpolarization and detection of 129 Xe gas. This device was limited by 129 Xe polarizations less than 1%, 129 Xe NMR signals smaller than 20 nT, and transport of hyperpolarized 129 Xe over millimeter lengths. Higher polarizations, versatile detection schemes, and flow of 129 Xe over larger distances are desirable for wider applications. Here we demonstrate an ultra-sensitive microfabricated platform that achieves 129 Xe polarizations reaching 7%, NMR signals exceeding 1 μT, lifetimes up to 6 s, and simultaneous two-mode detection, consisting of a high-sensitivity in situ channel with signal-to-noise of 10 5 and a lower-sensitivity ex situ detection channel which may be useful in a wider variety of conditions. 129 Xe is hyperpolarized and detected in locations more than 1 cm apart. Our versatile device is an optimal platform for microfluidic magnetic resonance in particular, but equally attractive for wider nuclear spin applications benefitting from ultra-sensitive detection, long coherences, and simple instrumentation.

36 MATERIALS SCIENCE↗

Probing Liquid Surfaces under Vacuum Using SEM and TOF-SIMS

Applying vacuum-based molecular probes of liquid surfaces would aid many environmental, biological, and industrial studies. However the high vapor pressure of water and most organic solvents largely prohibit this use. We report a newly developed versatile and self-contained vacuum interface for high-vapor pressure liquid surfaces, and its application in a time of flight secondary ion mass spectrometer (TOFSIMS) and scanning electron microscope (SEM). The self-contained module requires no wires or tubing connections to the outside of the instrument. It uses a microfluidic channel with a 3 micrometer diameter window into the flowing fluid beneath it. This window supports the liquid against the vacuum by the liquid’s surface tension, while limiting the high-density vapor region traversed by the probe beams to only a few microns. This aperture size also limits temperature and concentration changes due to evaporation of the solvent. The beam damage caused by the probe beams is largely negligible, as the flowing liquid surface self-renews. We demonstrate the performance of this microfluidic interface for in situ liquid surface TOFSIMS (ISLS-TOFSIMS) and SEM (ISLS-SEM) for chemical analysis of liquid surfaces. This device enables in situ liquid (ISL) studies in a wide range of vacuum analytical methods beyond SEM and TOFSIMS.

99 GENERAL AND MISCELLANEOUS↗

Advanced manufacturing provides tailor-made solutions for crystallography with x-ray free-electron lasers

Serial crystallography at large facilities, such as x-ray free-electron lasers and synchrotrons, evolved as a powerful method for the high-resolution structural investigation of proteins that are critical for human health, thus advancing drug discovery and novel therapies. However, a critical barrier to successful serial crystallography experiments lies in the efficient handling of the protein microcrystals and solutions at microscales. Microfluidics are the obvious approach for any high-throughput, nano-to-microliter sample handling, that also requires design flexibility and rapid prototyping to deal with the variable shapes, sizes, and density of crystals. Here, we discuss recent advances in polymer 3D printing for microfluidics-based serial crystallography research and present a demonstration of emerging, large-scale, nano-3D printing approaches leading into the future of 3D sample environment and delivery device fabrication from liquid jet gas-dynamic virtual nozzles devices to fixed-target sample environment technology.

36 MATERIALS SCIENCE↗

Ambient-temperature liquid jet targets for high-repetition-rate HED discovery science

High-power lasers can generate energetic particle beams and astrophysically relevant pressure and temperature states in the high-energy-density (HED) regime. Recently-commissioned high-repetition-rate (HRR) laser drivers are capable of producing these conditions at rates exceeding 1 Hz. However, experimental output from these systems is often limited by the difficulty of designing targets that match these repetition rates. To overcome this challenge, we have developed tungsten microfluidic nozzles, which produce a continuously replenishing jet that operates at flow speeds of approximately 10 m/s and can sustain shot frequencies up to 1 kHz. The ambient-temperature planar liquid jets produced by these nozzles can have thicknesses ranging from hundreds of nanometers to tens of micrometers. In this work, we illustrate the operational principle of the microfluidic nozzle and describe its implementation in a vacuum environment. Further, we provide evidence of successful laser-driven ion acceleration using this target and discuss the prospect of optimizing the ion acceleration performance through an in situ jet thickness scan. Future applications for the jet throughout HED science include shock compression and studies of strongly heated nonequilibrium plasmas. When fielded in concert with HRR-compatible laser, diagnostic, and active feedback technology, this target will facilitate advanced automated studies in HRR HED science, including machine learning-based optimization and high-dimensional statistical analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗