Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

MPACT Fast Neutron Multiplicity System Design Concepts

This report documents work performed by Idaho National Laboratory and the University of Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast-neutron multiplicity counting for assaying plutonium for materials protection, accountancy, and control purposes. This project seeks to develop a new type of neutron-measurement-based plutonium assay instrument suited for assaying advanced fuel cycle materials. Some current-concept advanced fuels contain high concentrations of plutonium; some of these concept fuels also contain other fissionable actinides besides plutonium. Because of these attributes the neutron emission rates of these new fuels may be much higher, and more difficult to interpret, than measurements made of plutonium-only materials. Fast neutron multiplicity analysis is one approach for assaying these advanced nuclear fuels. Studies have been performed to assess the conceptual performance capabilities of a fast-neutron multiplicity counter for assaying plutonium. Comparisons have been made to evaluate the potential improvements and benefits of fast-neutron multiplicity analyses versus traditional thermal-neutron counting systems. Fast-neutron instrumentation, using for example an array of liquid scintillators such as EJ-309, have the potential to either a) significantly reduce assay measurement times versus traditional approaches, for comparable measurement precision values, b) significantly improve assay precision values, for measurement durations comparable to current-generation technology, or c) moderating improve both measurement precision and measurement durations versus current-generation technology. Using the MCNPX-PoliMi Monte Carlo simulation code, studies have been performed to assess the doubles-detection efficiency for a variety of counter layouts of cylindrical liquid scintillator detector cells over one, two, and three rows. Ignoring other considerations, the best detector design is the one with the most detecting volume. However, operational limitations guide a) the maximum acceptable size of each detector cell (due to PSD performance and maximum-acceptable per-channel data throughput rates, limited by pulse pile-up and the processing rate of the electronics components of the system) and b) the affordability of a system due to the number of total channels of data to be collected and processed. As a first estimate, it appears that a system comprised of two rows of detectors 5" Ø $\times$ 3" would yield a working prototype system with excellent performance capabilities for assaying Pu-containing items and capable of handling high signal rates likely when measuring items with Pu and other actinides. However, it is still likely that gamma-ray shielding will be needed to reduce the total signal rate in the detectors. As a first step prior to working with these larger-sized detectors, it may be practical to perform scoping studies using small detectors, such as already-on-hand 3" Ø $\times$ 3" detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Gaussian Bayes classifier to differentiate chlorine-based chemical agents

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector. One of the difficult technical challenges is to discriminate the chlorine-based chemical agents. Especially, CN, CNB, CNS and CG have similar chemical compositions to make it hard to discriminate them with a higher confidence. Current identification algorithms for PINS systems with 252-Cf sources have been improved and updated continuously as more field data became available, and new algorithms was studied to complement the current algorithms by adopting the Gaussian Bayes classifier. These new algorithms were intended to be applied to a subset of chlorine-based chemical agents, and their main goal is discriminate CN, CNB, CNS and CG with their ratios of the chlorine neutron inelastic 1763keV peak to the chlorine thermal neutron capture 1959keV peak, which is referred to as the “Cl i/c” or “clic” ratio in this study. The Cl i/c ratios were assumed to follow Gaussian distributions with the means and the standard deviations unique to their corresponding chemical agents. The prior probabilities of these four chemical agents were optimized with a collection of field data to achieve the best performance in terms of precision or positive predictive value (PPV). Finally, their posterior probabilities as functions of the Cl i/c ratio were implemented in the current version of PINS analysis software in order to be tested with more field data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Melt Wire Analyses for the Colorado School of Mines (CSM 16-10584) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors and melt wires irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the Colorado School of Mines (CSM 16-10584) experiment which was conducted in position B5 of the ATR. Neutron fluence monitor results were reported in February 2021 in report Neutron Dosimetry for the Colorado School of Mines (CM 16-10584) Irradiation in ATR. This report presents the analyses of the melt wire capsules that were included along with the neutron fluence monitors. Each capsule was identified by the ID stamp on the bottom, then opened to assess the condition of the Pb and Zn-Al wires as well as the Bi powder. Pictures are included to illustrate the results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A high-temperature neutron diffraction study of Nb 2 AlC and TiNbAlC

In this paper, we report on the crystal structures of Nb 2 AlC and TiNbAlC actual composition (Ti 0.45 ,Nb 0.55 ) 2 AlC compounds determined from Rietveld analysis of neutron diffraction patterns in the 300-1173 K temperature range. The average linear thermal expansion coefficients of a Nb 2 AlC sample in the a and c directions are, respectively, 7.9(5)x10 -6 K -1 and 7.7(5)x10 -6 K -1 on one neutron diffractometer and 7.3(3)x10 -6 K -1 and 7.0(2)x10 -6 K -1 on a second diffractometer. The respective values for the (Ti 0.45 ,Nb 0.55 ) 2 AlC composition - only tested on one diffractometer - are 8.5(3)x10 -6 K -1 and 7.5(5)x10 -6 K -1 . These values are relatively low compared to other MAX phases. Like other MAX phases, however, the atomic displacement parameters show that the Al atoms vibrate with higher amplitudes than the Ti and C atoms, and 1 more along the basal planes than normal to them. In addition, when the predictions of the atomic displacement parameters obtained from density functional theory are compared to the experimental results, good quantitative agreement is found for the Al atoms. In case of the Nb and C atoms, the agreement was more qualitative.

36 MATERIALS SCIENCE↗

More Tools for Visualization and Analysis of Small-Angle Neutron Scattering Data: Descriptions and Examples

With the adoption of drtsans as the data reduction software for the GP-SANS, Bio-SANS and EQ-SANS instruments at ORNL, tools for data visualization and analysis that can be integrated into drtsans scripts are needed to further improve the user experience. New tools that do not need to be incorporated directly into data reduction scripts can also positively impact users during their experiments. In this report, a new set of tools is presented that complements the previous set released. The set includes tools for both fitting data and for visualizing data.

42 ENGINEERING↗

Technical Report: Toward a Scalable Algorithm to Compute High-Dimensional Integrals of Arbitrary Functions

Neutron experiments at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) frequently generate large amounts of data (on the order of 106-1012 data points). Hence, traditional data analysis tools run on a single CPU take too long to be practical and scientists are unable to efficiently analyze all data generated by experiments. Our goal is to develop a scalable algorithm to efficiently compute high-dimensional integrals of arbitrary functions. This algorithm can then be used to integrate the four-dimensional integrals that arise as part of modeling intensity from the experiments at the SNS. Here, three different one-dimensional numerical integration solvers from the GNU Scientific Library were modified and implemented to solve four-dimensional integrals. The results of these solvers on a final integrand provided by scientists at the SNS can be compared to the results of other methods, such as quasi-Monte Carlo methods, computing the same integral. A parallelized version of the most efficient method can allow scientists the opportunity to more effectively analyze all experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity Coefficients for Diffusion Coefficients and Other Reactor Physics Parameters using CE TSUNAMI-3D

The TSUNAMI (Tools for Sensitivity and Uncertainty Analysis Methodology Implementation) capabilities within the SCALE code system leverage sensitivity coefficients for many criticality safety applications, including quantifying the data-induced uncertainty in the eigenvalue of critical systems, quantifying computational biases, and selecting applicable benchmark experiments. TSUNAMI sensitivity and uncertainty analysis tools have traditionally been limited to criticality safety application spaces, but the introduction of Generalized Perturbation Theory (GPT) sensitivity methods by Jessee in 2009 and Perfetti in 2013 has extended the scope of SCALE adjoint-weighted sensitivity and uncertainty analysis to include reactor physics applications. The continuous-energy (CE) TSUNAMI-3D GPT sensitivity analysis methods were originally developed to calculate sensitivity coefficients for a limited number of reaction-rate responses using CE Monte Carlo methods. These tools were recently applied in an Oak Ridge National Laboratory (ORNL)-directed research and development project to improve the efficiency of {sup 252}Cf production in the High Flux Isotope Reactor (HFIR) by understanding the sensitivity of key heavy actinide capture-to- fission ratios to potential system design changes. This work further extends the applicability of the CE TSUNAMI- 3D GPT methods to reactor physics applications by enabling the calculation of sensitivity coefficients for an expanded set of reaction rate responses-including a first-ever capability for conducting sensitivity analysis of neutron diffusion coefficients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Interactive automated Bragg peak identification with 3D neutron scattering data

Neutron scattering experiments have undergone significant technological development through large area detectors with concurrent enhancements in neutron transport and electronic functionality. Data collected for neutron events include detector pixel location in 3D, time and associated metadata, such as, sample orientation, neutron wavelength, and environmental conditions. RadiaSoft and Oak Ridge National Laboratory personnel are considering single-crystal diffraction data from the TOPAZ instrument. We are leveraging a new method for rapid, interactive analysis of neutron data using NVIDIA’s IndeX 3D volumetric visualization framework. We have implemented machine learning techniques to automatically identify Bragg peaks and separate them from diffuse backgrounds and analyze the crystalline lattice parameters for further analysis. The implementation of automatic peak identification into IndeX allows scientists to visualize and analyze data in real-time. Our methods include a robust comparison with current analysis techniques which show improvement in a variety of aspects. These improvements will be incorporated into IndeX for visualization to allow scientists an interactive tool for crystal analysis.

Kilpatrick, Matthew↗

Active interrogation of Special Nuclear Material containers using AmBe quasi-forward biased directional source and PGNAA

Special Nuclear Material (SNM) including 95% 235 U and 239 Pu is capable of being identified by utilizing a quasi-forward directional AmBe source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). HPGe and LaBr 3 detector arrays were used to identify and quantify the peak-to-background and peak-to-total ratios of the associated photon spectra from the SNM encased in a polyethylene shield. The conducted simulations varied the volume of the SNM and neutron source strength in the MCNP data card to conduct an uncertainty analysis. Photopeaks identified include K-shell X-rays from 235 U and 239 Pu, 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peak from the prompt gamma interaction from hydrogen. Relationships between peak-to-total and peak-to-background as a function of SNM and particle history were investigated to aid in the analysis. The capabilities of both detector systems to acquire well resolved photopeak with a 5% relative error or less, with a 1 Ci source activity, and a peak-to-background ratio of 1.15. Finally, this was determined to take 326 s for LaBr 3 and 163 s for HPGe which is comparable to current methods for material detection which take between 100 and 900 s to acquire.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nondestructive test method accurately sorts mixed bolts

Neutron activation analysis method sorts copper plated steel bolts from nickel plated steel bolts. Copper and nickel plated steel bolt specimens of the same configuration are irradiated with thermal neutrons in a test reactor for a short time. After thermal neutron irradiation, the bolts are analyzed using scintillation energy readout equipment.

Dezeih, C. J.↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Imaging at LANSCE—From Cold to Ultrafast

In recent years, neutron radiography and tomography have been applied at different beam lines at Los Alamos Neutron Science Center (LANSCE), covering a very wide neutron energy range. The field of energy-resolved neutron imaging with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as quantitative density measurements, was pioneered at the Target 1 (Lujan center), Flight Path 5 beam line and continues to be refined. Applications include: imaging of metallic and ceramic nuclear fuels, fission gas measurements, tomography of fossils and studies of dopants in scintillators. The technique provides the ability to characterize materials opaque to thermal neutrons and to utilize neutron resonance analysis codes to quantify isotopes to within 0.1 atom %. The latter also allows measuring fuel enrichment levels or the pressure of fission gas remotely. More recently, the cold neutron spectrum at the ASTERIX beam line, also located at Target 1, was used to demonstrate phase contrast imaging with pulsed neutrons. This extends the capabilities for imaging of thin and transparent materials at LANSCE. In contrast, high-energy neutron imaging at LANSCE, using unmoderated fast spallation neutrons from Target 4 [Weapons Neutron Research (WNR) facility] has been developed for applications in imaging of dense, thick objects. Using fast (ns), time-of-flight imaging, enables testing and developing imaging at specific, selected MeV neutron energies. The 4FP-60R beam line has been reconfigured with increased shielding and new, larger collimation dedicated to fast neutron imaging. The exploration of ways in which pulsed neutron beams and the time-of-flight method can provide additional benefits is continuing. We will describe the facilities and instruments, present application examples and recent results of all these efforts at LANSCE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dispersive optical model analysis of 208 Pb generating a neutron-skin prediction beyond the mean field

In this work, a nonlocal dispersive optical model analysis is carried out for neutrons and protons in 208 Pb. Elastic-scattering angular distributions, total and reaction cross sections, single-particle energies, neutron and proton numbers, the charge distribution, and the binding energy are fitted to extract the neutron and proton self-energies both above and below the Fermi energy. From the single-particle propagator derived from these self-energies, we determine the charge and matter distributions in 208 Pb. The predicted spectroscopic factors are consistent with results from the ($\textit{e,e}'\textit{p}$) reaction and inelastic-electron-scattering data to very high-spin states. Sensible results for the high-momentum content of neutrons and protons are obtained, with protons appearing more correlated, in agreement with experiment and ab initio calculations of asymmetric matter. A neutron skin of 0.25 ± 0.05 fm is deduced. An analysis of several nuclei leads to the conclusion that finite-size effects play a nonnegligible role in the formation of the neutron skin in finite nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗