Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERMANENT MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Development of compact size penning ion source for compact neutron generator

For long-life operation, easy to mount and compact in size penning type ion sources are widely used in different fields of research such as neutron generators, material research, and surface etching. One penning type ion source has been developed in our laboratory. Applying high voltage of 2 kV between two oppositely biased electrodes and using permanent magnet of 500 gauss magnetic field along the axis, we had produced the glow discharge in the plasma region. The performance of this source was investigated using nitrogen gas. Deuterium ions were produced and extracted on the basis of chosen electrodes and the angle of extraction. Using a single aperture plasma electrode, the beam was extracted along the axial direction. The geometry of plasma electrode is an important factor for the efficient extraction of the ions from the plasma ion source. The extracted ion current depends upon the shape of the plasma meniscus. A concave shaped plasma meniscus produces converged ion beam. The convergence of extracted ions is related to the extraction electrode angle. The greater the angle, the more the beam converges. We had studied experimentally this effect with a compact size penning ion source. The detailed comparison among the different extraction geometry and different electrode angle are discussed in this paper.

43 PARTICLE ACCELERATORS↗

Cryogenic Field Measurement of Pr{sub 2}Fe{sub 14}B Undulator and Performance Enhancement Options at the NSLS-II

Short period (14.5mm) hybrid undulator arrays composed of Praseodymium Iron Boron (Pr{sub 2}Fe{sub 14}B) magnets (CR53, NEOMAX, Inc.) and vanadium permendur poles have been fabricated at Brookhaven National Laboratory. Unlike Neodymium Iron Boron (Nd{sub 2}Fe{sub 14}B) magnets which exhibit spin reorientation at a temperatures below 150 K, PrFeB arrays monotonically increase performance with lower operating temperature. It opens up the possibility for use in operating a cryo-permanent magnet undulator (CPMU) in the range of 40 K to 60 K where very efficient cryocoolers are available. Magnetic flux density profiles were measured at various temperature ranges from room temperature down to liquid helium (LHe) using the Vertical Testing Facility (VTF) at the National Synchrotron Light Source-II (NSLS-II). Temperature variations of phase error have been characterized. In addition, we examined the use of textured Dysprosium (Dy) poles to replace permendur poles to obtain further improvement in performance.

43 PARTICLE ACCELERATORS↗

High power l-band fast phase shifter

Following successful testing of a concept prototype of a waveguide-based high power phase shifter, a design of a fast, high power device has been developed. The shifter uses two magnetically biased blocks of Yttrium Iron Garnet (YIG) positioned along the side walls of a rectangular waveguide. The cross-section of the waveguide is chosen to suppress unwanted RF modes that could otherwise compromise performance of the phase shifter. Static bias field in the YIG blocks is created by employing permanent magnets. Low inductance coils in the same magnetic circuit excite fast component of the bias field. Design of the device ensures effective heat extraction from the YIG blocks and penetration of the fast magnetic field inside the waveguide with minimum delay. This paper summarizes main steps in this development and gives brief description of the system.

43 PARTICLE ACCELERATORS↗

Laser plasma in a magnetic field

Laser ion source (LIS) is a candidate among various heavy ion sources. A high density plasma produced by Nd:yttrium aluminum garnet laser with drift velocity realizes high current and high charge state ion beams. In order to obtain higher beam current, we made experiments using the LIS with a magnetic field by which a confinement effect can make higher beam current. We measured total current by Faraday cup and analyzed charge distribution by electrostatic ion analyzer. It is shown that the ion beam charge state is higher by a permanent magnet.

43 PARTICLE ACCELERATORS↗

Microstructural and magnetic property evolution with different heat-treatment conditions in an alnico alloy

Further property enhancement of alnico, an attractive near-term, non-rare-earth permanent magnet alloy system, primarily composed of Al, Ni, Co, and Fe, relies on improved morphology control and size refinement of its complex spinodally decomposed nanostructure that forms during heat-treatment. Using a combination of transmission electron microscopy and atom probe tomography techniques, this study evaluates the magnetic properties and microstructures of an isotropic 32.4Fe-38.1Co-12.9Ni-7.3Al-6.4Ti-3.0Cu (wt.%) alloy in terms of processing parameters such as annealing temperature, annealing time, application of an external magnetic field, as well as low-temperature “draw” annealing. Optimal spinodal morphology and spacing is formed within a narrow temperature and time range (~840 °C and 10 min) during thermal-magnetic annealing (MA). The ideal morphology is a mosaic structure consisting of periodically arrayed ~40 nm diameter (Fe-Co)-rich rods (α 1 phase) embedded in an (Al-Ni)-rich (α 2 phase) matrix. A Cu-enriched phase with a size of ~3–5 nm is located at the corners of two adjacent {110} facets of the α 1 phase. The MA process significantly increased remanence (B r ) (~40–70%) of the alloy due to biased elongation of the α 1 phase along the <100> crystallographic direction, which is closest in orientation to the applied magnetic field. As a result, the optimum magnetic properties of the alloy with an intrinsic coercivity (H cj ) of 1845 Oe and a maximum energy product (BH max ) of 5.9 MGOe were attributed to the uniformity of the mosaic structure.

36 MATERIALS SCIENCE↗

Cryogenic Undulator for a Table Top FEL

A laser plasma accelerator is under development at the Max-Planck-Institut fuer Quantenoptik in Garching. This accelerator will be part of an X-ray table top FEL in the future. The FEL radiation will be produced with a small period in-vacuum undulator. The coercivity of the magnetic material has to be sufficiently high in order to avoid demagnetization due to electron losses. The best performance can be achieved with a cryogenic permanent magnet undulator design. (Nd{sub 0.2}Pr{sub 0.8}){sub 2}Fe{sub 14}B magnets are suited for low temperatures since they do not suffer from a spin reorientation. A new (Nd{sub 0.2}Pr{sub 0.8}){sub 2}Fe{sub 14}B material has been characterized at various temperatures and the results are presented. Based on this material a 20 period prototype with a period length of 9 mm and a magnetic gap of 2.5 mm is currently under construction.

36 MATERIALS SCIENCE↗

A Far-infrared Undulator for Coherent Synchrotron Radiation and Free Electron Laser at Tohoku University

In order to develop an intense far-infrared radiation source, a high quality electron beam has been studied at Tohoku University, Sendai. The bunch length of the beam expected is very much shorter than terahertz (THz) wavelength, so that coherent spontaneous emission of synchrotron radiation will be a promising high brilliant far-infrared source. An undulator consisting of permanent magnets has been designed in which optional free electron laser (FEL) will be operated in free space mode. Consequently the minimum gap of the undulator is decided to be 54 mm for 0.36 mm radiation to avoid diffraction loss, and then the period length of 10 cm is employed. The undulator may cover a wavelength range from 0.18 to 0.36 mm with the beam energy of 17 MeV. Property of coherent THz radiation from the undulator and possibility of novel pre-bunched THz FEL is discussed.

43 PARTICLE ACCELERATORS↗

One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a low voltage, high current extraction system for the ITER Ion Source

A Test Facility is planned to be built in Padova to assemble and test the Neutral Beam Injector for ITER. In the same Test Facility the Ion Source will be tested in a dedicated facility planned to operate in parallel to the main 1 MV facility. Purpose of the full size Ion Source is to optimize the Ion Source performance by maximizing the extracted negative ion current density and its spatial uniformity and by minimizing the ratio of co-extracted electrons. In this contribution the design of the extractor and accelerator grids for a 100 kV, 60 A system is presented. The trajectories of the negative ions, calculated with the SLACCAD code [1], have been benchmarked by a new 2D code (BYPO [2]) which solves in a self consistent way the electric fields in presence of electric charge and magnetic fields. The energy flux intercepted by the grids is estimated by using the Montecarlo code EAMCC [3] and the grids designed according to the constraints set by the permanent magnets and by the cooling channels. The interaction of backstreaming ions due to the ionization process with the grids and the Ion Source backplate is investigated and its impact on the project and performance discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ab initio calculations of magnetic properties of the interstitially doped YFe{sub 11}Mo compound

The recent increase in the number of studies of RFe{sub 11–x}M{sub x} compounds is related to their promising application as permanent magnets. However, the insufficiently high value of the Curie temperature T{sub C} of these compounds is a barrier to their widespread use. The increase in the Curie temperature of these compounds is achieved by doping with the light nonmetallic atoms such as hydrogen, nitrogen, and carbon. In this paper, it is shown numerically that this doping leads to drastic changes of the electronic band dispersions in a wide energy region around the Fermi level. This in turn changes values of the magnetic moments of ions and Heisenberg exchange interaction parameters. The values of ab initio calculated magnetic moments and direct exchange interaction parameters make it possible to calculate the Curie temperatures for both parent and nitrogen-doped compounds within the mean-field approach to the Heisenberg model in the sample of YFe{sub 11}Mo, a typical representative of the R(Fe,M){sub 12}L class. Theoretical values of T{sub C} obtained for YFe{sub 11}Mo and YFe{sub 11}MoN (514 and 723 K respectively) are consistent with experimental ones (472 and 664 K) with an accuracy of 10%. Also, the calculated increase in T{sub C} upon nitrogenization (about 200 K) is in good agreement with the experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sm{sub 2}Fe{sub 17}N{sub x} nanoflakes prepared by surfactant assisted cryomilling

Hard magnetic Sm{sub 2}Fe{sub 17}N{sub x} nanoflakes were prepared by surfactant assisted ball milling (SABM) at low temperature using liquid nitrogen cooling (surfactant assisted cryomilling). 2-methyl pentane was used as a milling medium and oleylamine as a surfactant. The morphology, structure, and magnetic properties of Sm{sub 2}Fe{sub 17}N{sub x} were investigated using scanning electron microscopy, X-ray diffraction, and vibrating sample magnetometer, respectively. By comparing Sm{sub 2}Fe{sub 17}N{sub x} nanoflakes produced by SABM at low temperature and at room temperature, we found that the former has many interesting features: more homogeneous morphology, smaller size, especially markedly increased remanent magnetization (M{sub r}), saturation magnetization (M{sub s}), and remanent magnetization ratio (M{sub r}/M{sub s}). These Sm{sub 2}Fe{sub 17}N{sub x} nanoflakes have great potential to be used for preparing high performance bonded permanent magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Design of Motors for Increased Efficiency in Residential Commercial Buildings

Research progress on understanding magnetic steel core losses is presented in this report. Three major aspects have been thoroughly investigated: 1, experimental characterization of core losses, 2, fundamental physical understanding of core losses and development of core loss formulas, and 3, design of more efficient machine based on the new formulations. Considerable progress has been achieved during the four years of research and the main achievements are summarized in the following: For the experimental characterization, a specially designed advanced commercial test bench was commissioned in addition to the development of a laboratory system with advanced capabilities. The measured properties are core losses at low and higher frequencies, with sinusoidal and non-sinusoidal excitations, at different temperatures, with different measurement apparatus (Toroids, Epstein etc). An engineering-based core loss formula has been developed which considers skin effect. The formula can predict core losses for both sinusoidal and non-sinusoidal flux densities and frequencies up to 4000 Hz. The formula is further tested in electric machines. The formula error range is 1.1% - 7.6% while the standard formulas can have % errors between -8.5% {-+} 44.7%. Two general core loss formulas, valid for different frequencies and thickness, have been developed by analytically and numerically solving Maxwell's equations based on a physical investigation of the dynamic hysteresis effects of magnetic materials. To our knowledge, they are the first models that can offer accurate core loss prediction over a wide range of operating frequencies and lamination thicknesses without a massive experimental database of core losses. The engineering core loss formula has been used with commercial software. The formula performs better than the modified Steinmetz and Bertotti's model used in Cedrat/Magsoft Flux 2D/3D. The new formula shows good correlation with measured results under both sinusoidal and non-sinusoidal excitations. A permanent magnet synchronous motor has been designed with the use of the engineering formula with Flux2D. There was acceptable agreement between predictions and measurements. This was further tested on an induction motor with toroid results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of vanadium on phase composition and hard magnetic properties of as-solidified and heat-treated Sm–Fe–(Ti,V) alloys

Although the intrinsic magnetic properties of Ti-stabilized Sm(Fe,Co,Ti) 12 compounds exhibit potential of excellent rare-earth-lean permanent magnets, it has been much easier to realize large coercivities with the isostructural compounds stabilized by either V or by certain combinations of Ti and V. To elucidate the influence of V on the microstructure and magnetic properties, a series of Sm 8.1 Fe 78.4 (Ti 1-x V x ) 13.5 alloys was studied after arc-melting and annealing at 850–1000 °C. The alloys were found to fall into three groups. For x ≤ 0.2, solidification generates mostly the Sm(Fe,Ti,V) 12 phase, but annealing converts at least part of it into the non-magnetic Sm(Fe,Ti,V) 11 and the magnetically soft Sm 2 (Fe,Ti,V) 17 phases. For 0.2 < x < 0.6, the alloys solidify into a near-equilibrium mixture of the Sm(Fe,Ti,V) 12 , TiFe 2 and Sm-rich phases. For x ≥ 0.6, solidification generates large fractions of α-Fe solid solution and Sm-rich phases; an annealing step is necessary to complete the formation of Sm(Fe,Ti,V) 12 phase. Also, for x ≥ 0.6 the temperature below which the Sm(Fe,Ti,V) 12 phase is stable decreases with x, as does the fraction of this phase formed during solidification. Here, the differences between these three groups of alloys suggest different strategies for developing hard magnetic properties, with the likelihood of a success increasing with increasing x. For x ≥ 0.6, heat treatment alone is demonstrated to generate a microstructure of micron and submicron Sm(Fe,Ti 1-x V x ) 12 crystallites separated by a Sm-rich phase and exhibiting a coercivity with values up to 3.5 and 5.7 kOe for x = 0.8 and 1.0, respectively.

36 MATERIALS SCIENCE↗

Novel motor design for rotating anode x-ray tubes operating in the fringe field of a magnetic resonance imaging system

Purpose: Using hybrid x-ray/MR (XMR) systems for image guidance during interventional procedures could enhance the diagnosis and treatment of neurologic, oncologic, cardiovascular, and other disorders. The authors propose a close proximity hybrid system design in which a C-arm fluoroscopy unit is placed immediately adjacent to the solenoid magnet of a MR system with a minimum distance of 1.2 m between the x-ray and MR imaging fields of view. Existing rotating anode x-ray tube designs fail within MR fringe field environments because the magnetic fields alter the electron trajectories in the x-ray tube and act as a brake on the induction motor, reducing the rotation speed of the anode. In this study the authors propose a novel motor design that avoids the anode rotation speed reduction. Methods: The proposed design replaces the permanent magnet stator found in brushed dc motors with the radial component of the MR fringe field. The x-ray tube is oriented such that the radial component of the MR fringe field is orthogonal to the cathode-anode axis. Using a feedback position sensor and the support bearings as electrical slip rings, the authors use electrical commutation to eliminate the need for mechanical brushes and commutators. A vacuum compatible prototype of the proposed motor design was assembled, and its performance was evaluated at various operating conditions. The prototype consisted of a 3.1 in. diameter anode rated at 300 kHU with a ceramic rotor that was 5.6 in. in length and had a 2.9 in. diameter. The material chosen for all ceramic components was MACOR, a machineable glass ceramic developed by Corning Inc. The approximate weight of the entire assembly was 1750 g. The maximum rotation speed, angular acceleration, and acceleration time of the motor design were investigated, as well as the dependence of these parameters on rotor angular offset, magnetic field strength, and field orientation. The resonance properties of the authors' assembly were also evaluated to determine its stability during acceleration, and a pulse width modulation algorithm was implemented to control the rotation speed of the motor. Results: At a magnetic flux density of 41 mT orthogonal to the axis of rotation (on the lower end of the expected flux density in the MR suite) the maximum speed of the motor was found to be 5150 revolutions per minute (rpm). The acceleration time necessary to reach 3000 rpm was found to be approximately 10 s at 59 mT. The resonance frequency of the assembly with the anode attached was 1310 rpm (21.8 Hz) which is far below the desired operating speeds. Pulse width modulation provides an effective method to control the speed of the motor with a resolution of 100 rpm. Conclusions: The proposed design can serve as a direct replacement to the conventional induction motor used in rotating anode x-ray tubes. It does not suffer from a reduced rotation speed when operating in a MR environment. The presence of chromic steel bearings in the prototype prevented testing at the higher field strengths, and future iterations of the design could eliminate this shortcoming. The prototype assembly demonstrates proof of concept of the authors' design and overcomes one of the major obstacles for a MR compatible rotating anode x-ray tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and calibration of a Thomson parabola with microchannel plate for the detection of laser-accelerated MeV ions

This article reports on the development and application of a Thomson parabola (TP) equipped with a (90x70) mm{sup 2} microchannel-plate (MCP) for the analysis of laser-accelerated ions, produced by a high-energy, high-intensity laser system. The MCP allows an online measurement of the produced ions in every single laser shot. An electromagnet instead of permanent magnets is used that allows the tuning of the magnetic field to adapt the field strength to the analyzed ion species and energy. We describe recent experiments at the 100 TW laser facility at the Laboratoire d'Utilization des Lasers Intenses (LULI) in Palaiseau, France, where we have observed multiple ion species and charge states with ions accelerated up to 5 MeV/u (O{sup +6}), emitted from the rear surface of a laser-irradiated 50 {mu}m Au foil. Within the experiment the TP was calibrated for protons and for the first time conversion efficiencies of MeV protons (2-13 MeV) to primary electrons (electrons immediately generated by an ion impact onto a surface) in the MCP are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra High-Temperature Magnetic Bearing System for s-CO 2 Turbines/Expanders. Phase II Final Report

The goal of this project is to design and construct of a prototype of ultra-high temperature permanent magnet (UHT–PM), which provides the force to pull the spinning shaft towards the target position in the magnetic bearing (MB) clearance circle. This project will develop a PM biased MB system, that is actively cooled to the 550°C maximum operating temperature limit of PMs. The MB test environment will include 700°C, 40krpm and 4,000 psi requirements to advance the supercritical carbon dioxide (sCO 2 ) and other types of Brayton power cycle systems. The proposed novel MBs combine PMs for supplying the bias field and electromagnets for supplying the control field, both in UHT conditions. The choice of material is the UHT Sm-Co PMs (US patent 6,451,132) due to their significantly better thermal stability. The 6-pole homopolar design permits uninterrupted force delivery via a redundant control capability (US patent 7,429,811) even if 3 poles were to fail. The Phase I efforts was to focus on development and demonstration of component technologies and detailed design of full scale components and a demonstrator test rig for use in Phase II. UHT–PMs were produced and used in the MB actuator. The operating environment of the EEC-T550 Sm-Co magnet material could be extended by implementing active cooling. Electromagnetic coils imbedded in the MB provide forces to stabilize the shaft position at the target via sensing and control stages. Shaft position sensors enable to identify the present position of the spinning shaft relative to its desired target position in the MB clearance circle (air gap). Auxiliary bearings will be installed to provide a backup support system in the event that power to the MB fails or there is a fault in a device providing current to the MB coils. For control, reliability and safety reasons the sensors and auxiliary bearings are typically located as close as possible to the MBs, which exposes them to the same environmental conditions. Development of only the actuator for the UHT environment is an inadequate approach to complete integration of the MB system in the turbine/expander. Therefore the UHT sensor and auxiliary bearing were designed and developed along with the actively cooled, UHT-PM actuator development. Although shaft position sensors are commercially available (Kaman) they may cost up to $10k per channel, and a full 5 axis magnetic suspension is best implemented with up to 20 sensors. Once successfully completed, this project will significantly extend the operating environment capability for turbomachinery applications such as nuclear power, concentrated solar thermal, fossil fuel, geothermal, and shipboard propulsion. The further advancement of UHT-PM-MB will also strengthen the US position in PM technology, which is presently heavily dominated by China. The UHT Sm-Co magnet material that will be utilized in the proposed work has been developed exclusively by the project proposer. Many actuators, motors, generators and other MB applications will greatly benefit from the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of eddy currents due to a vacuum chamber wall in the airgap of a moving-magnet linear actuator

This paper discusses the effects of eddy currents induced in an electrically conducting plate which is placed in the airgap of a linear synchronous actuator with moving permanent magnets. The eddy currents induced in this plate, which is part of a controlled atmosphere chamber, cause not only damping but also deteriorate the actuator performance by disturbing the position measurement with Hall sensors. Furthermore, feed-forward controllers are less effective due to the suppression of high frequent armature fields. These effects are analyzed with an analytical model and verified with finite element simulations and measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On dysprosium utilisation in multi-main-phase Nd–Dy–Fe–B magnets with core–shell microstructures

The development of high-performance Nd–Dy–Fe–B magnets that minimise the consumption of the scarce rare earth (RE) element Dy remains a major global scientific and technological quest. Here, we designed an alloy microstructure comprising of a uniform Dy-lean core–Dy-rich shell in a series of multi-main-phase (MMP) Nd–Dy–Fe–B magnets. The resulting MMP Dy1 and Dy3 magnets with an overall Dy level of 1 and 3 wt.% possessed values of 0.48 and 0.29 T/wt.% of coercivity increment per unit weight percentage of the Dy addition, respectively. Most importantly, the resulting MMP Dy3 magnet exhibited a high coercivity (2.38 T), an excellent thermal stability of the coercivity (|β| = 0.531%/°C), a high squareness factor (> 95%), all with little diminishment in the remanent magnetisation (1.35 T) and maximum energy product (43.6 MGOe). These properties are superior to the currently available sintered Nd–Dy–Fe–B magnets which utilise higher levels of Dy of 5 wt.%. Via magnetic and multi-scale microstructural characterisation experiments and micromagnetic simulations, the formation of the Dy-lean core–Dy-rich shell microstructure is rationalised via solid-state-diffusion and solution reprecipitation during liquid-phase sintering. The Dy-lean core–Dy-rich shell microstructure and the non-ferromagnetic low-Fe RE-rich grain boundary phase led to the synergistic magnetic performance. This is significant in the context of the MMP Nd–Dy–Fe–B magnets being applied to large-scale production. The present work establishes a pathway for the more sustainable utilisation of Dy in permanent magnets via formation of a uniform core–shell microstructure.

36 MATERIALS SCIENCE↗