Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Dynamic deformation and fracture of single crystal silicon: Fracture modes, damage laws, and anisotropy

Impact fracture of single-crystal Si is critical to long-term reliability of electronic devices and solar cells for its wide use as components or substrates in semiconductor industry. Single-crystal Si is loaded along two different crystallographic directions with a split Hopkinson pressure bar integrated with an in situ x-ray imaging and diffraction system. Bulk stress histories are measured, simultaneously with x-ray phase contrast imaging (XPCI) and Laue diffraction. Damage evolution is quantified with grayscale maps from XPCI. Single-crystal Si exhibits pronounced anisotropy in fracture modes, and thus fracture strengths and damage evolution. For loading along [11¯ 0] and viewing along [001], (1¯1¯0)[11¯ 0] cleavage is activated and induces horizontal primary cracks followed by perpendicular wing cracks. However, for loading along [011¯] and viewing along [111], random nucleation and growth of shear and tensile-splitting crack networks lead to catastrophic failure of materials with no cleavage. The primary-wing crack mode leads to a lower characteristic fracture strength due to predamage, but a more concentrated strength distribution, i.e., a higher Weibull modulus, compared to the second loading case. Furthermore, the sequential primary cracking, wing cracking and wing-crack coalescence processes result in a gradual increase of damage with time, deviating from theoretical predictions. Particle size and aspect ratios of fragments are discussed with postmortem fragment analysis, which verifies fracture modes observed in XPCI.

36 MATERIALS SCIENCE↗

Avalanching strain dynamics during the hydriding phase transformation in individual palladium nanoparticles

Phase transitions in reactive environments are crucially important in energy and information storage, catalysis and sensors. Nanostructuring active particles can yield faster charging/ discharging kinetics, increased lifespan and record catalytic activities. However, establishing the causal link between structure and function is challenging for nanoparticles, as ensemble measurements convolve intrinsic single-particle properties with sample diversity. Here we study the hydriding phase transformation in individual palladium nanocubes in situ using coherent X-ray diffractive imaging. The phase transformation dynamics, which involve the nucleation and propagation of a hydrogen-rich region, are dependent on absolute time (aging) and involve intermittent dynamics (avalanching). A hydrogen-rich surface layer dominates the crystal strain in the hydrogen-poor phase, while strain inversion occurs at the cube corners in the hydrogen-rich phase. A three-dimensional phase-field model is used to interpret the experimental results. In conclusion, our experimental and theoretical approach provides a general framework for designing and optimizing phase transformations for single nanocrystals in reactive environments.

36 MATERIALS SCIENCE↗

SU-E-J-189: Determination of Markerless Lung Tumor Position in Real Time: A Feasibility Study Using a Novel Tomo-Cinegraphy Imaging

Purpose: A Tomo-Cinegraphy (TC) is a method to generate a series of temporal tomographic images from projection images of the on-board imager (OBI) while gantry is moving. It is to test if this technique is useful to determine a lung tumor position during treatments. Methods: Tomographic image via background subtraction, TIBS uses a priori anatomical information from a previous CT scan to isolate a SOI from a planar kV image by factoring out the attenuations by tissues outside the SOI (background). This idea was extended to a TC, which enables to generate tomographic images of same geometry from the projection of different gantry angles and different breathing phases. Projection images of a lung patient for CBCT acquisition are used to generate TC images. A region of interest (ROI) is selected around a tumor adding 2cm margins. Center of mass (COM) of the ROI is traced to determine tumor position for every projection images. Results: Tumor is visible in the TC images while the OBI projections are not. The coordinates of the COMs represent the temporal tumor positions. While, it is not possible to trace the tumor motion using the projection images. A source of time delay is the time to acquire projection images, which is always less than a second. Conclusion: TC allows tracking the tumor positions without fiducial markers in real time for some lung patients, if the projection images are acquired during treatments. Partially supported by NIH R01CA133539.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-11: Feasibility of Super-Resolution Time-Resolved 4DMRI for Multi-Breath Volumetric Motion Simulation in Radiotherapy Planning

Purpose: To develop a novel super-resolution time-resolved 4DMRI technique to evaluate multi-breath, irregular and complex organ motion without respiratory surrogate for radiotherapy planning. Methods: The super-resolution time-resolved (TR) 4DMRI approach combines a series of low-resolution 3D cine MRI images acquired during free breathing (FB) with a high-resolution breath-hold (BH) 3DMRI via deformable image registration (DIR). Five volunteers participated in the study under an IRB-approved protocol. The 3D cine images with voxel size of 5×5×5 mm{sup 3} at two volumes per second (2Hz) were acquired coronally using a T1 fast field echo sequence, half-scan (0.8) acceleration, and SENSE (3) parallel imaging. Phase-encoding was set in the lateral direction to minimize motion artifacts. The BH image with voxel size of 2×2×2 mm{sup 3} was acquired using the same sequence within 10 seconds. A demons-based DIR program was employed to produce super-resolution 2Hz 4DMRI. Registration quality was visually assessed using difference images between TR 4DMRI and 3D cine and quantitatively assessed using average voxel correlation. The fidelity of the 3D cine images was assessed using a gel phantom and a 1D motion platform by comparing mobile and static images. Results: Owing to voxel intensity similarity using the same MRI scanning sequence, accurate DIR between FB and BH images is achieved. The voxel correlations between 3D cine and TR 4DMRI are greater than 0.92 in all cases and the difference images illustrate minimal residual error with little systematic patterns. The 3D cine images of the mobile gel phantom preserve object geometry with minimal scanning artifacts. Conclusion: The super-resolution time-resolved 4DMRI technique has been achieved via DIR, providing a potential solution for multi-breath motion assessment. Accurate DIR mapping has been achieved to map high-resolution BH images to low-resolution FB images, producing 2Hz volumetric high-resolution 4DMRI. Further validation and improvement are still required prior to clinical applications. This study is in part supported by the NIH (U54CA137788/U54CA132378).

60 APPLIED LIFE SCIENCES↗

Registration of interferometric SAR images

Interferometric synthetic aperture radar (INSAR) is a new way of performing topography mapping. Among the factors critical to mapping accuracy is the registration of the complex SAR images from repeated orbits. A new algorithm for registering interferometric SAR images is presented. A new figure of merit, the average fluctuation function of the phase difference image, is proposed to evaluate the fringe pattern quality. The process of adjusting the registration parameters according to the fringe pattern quality is optimized through a downhill simplex minimization algorithm. The results of applying the proposed algorithm to register two pairs of Seasat SAR images with a short baseline (75 m) and a long baseline (500 m) are shown. It is found that the average fluctuation function is a very stable measure of fringe pattern quality allowing very accurate registration.

Lin, Qian↗

Visualization of dynamic fiber-matrix interfacial shear debonding

To visualize the debonding event in real time for the study of dynamic crack initiation and propagation at the fiber–matrix interface, a modified tension Kolsky bar was integrated with a high-speed synchrotron X-ray phase-contrast imaging setup. In the gage section, the pull-out configuration was utilized to understand the behavior of interfacial debonding between SC-15 epoxy matrix and S-2 glass fiber, tungsten wire, steel wire, and carbon fiber composite Z-pin at pull-out velocities of 2.5 and 5.0 m s –1 . The load history and images of the debonding progression were simultaneously recorded. Both S-2 glass fiber and Z-pin experienced catastrophic interfacial debonding whereas tungsten and steel wire experienced both catastrophic debonding and stick–slip behavior. Even though S-2 glass fiber and Z-pin samples exhibited a slight increase and tungsten and steel wire samples exhibited a slight decrease in average peak force and average interfacial shear stress as the pull-out velocities were increased, no statistical difference was found for most properties when the velocity was increased. Furthermore, the debonding behavior for each fiber material is similar with increasing pull-out velocity. Thus, the debonding mechanism, peak force, and interfacial shear stress were rate insensitive as the pull-out velocity doubled from 2.5 to 5.0 m s –1 . In conclusion, scanning electron microscope imaging of recovered epoxy beads revealed a snap-back behavior around the meniscus region of the bead for S-2 glass, tungsten, and steel fiber materials at 5.0 m s –1 whereas those at 2.5 m s –1 exhibited no snap-back behavior.

36 MATERIALS SCIENCE↗

Directional shock diode behavior through the interaction of geometric voids in engineered polymer assemblies

With the advent of additive manufacturing (AM) techniques, a new class of shockwave mitigation and structural supports has been realized through the hierarchical assembly of polymer materials. To date, there have been a limited number of studies investigating the role of structure on shockwave localization and whether AM offers a means to tailor shockwave behavior. Of particular interest is whether the mesoscopic structure can be tailored to achieve shockwave properties in one direction of impact vs the other. In this work, we illustrate directional response in engineered polymer foams. In situ time-resolved x-ray phase contrast imaging at the Advanced Photon Source was used to characterize these diode-like structures. This work offers a breakthrough in materials technology for the development of protective structures that require augmentation of shock in one direction while diminishing transmission in the opposite direction.

42 ENGINEERING↗

In-situ X-ray observations of ultrasound-induced explosive decomposition

High-strain mechanical loading of polymer-bonded explosives can produce significant stress concentrations due to microstructural heterogeneities, resulting in localized thermal “hot spots”. Ultrasound produces similar effects and has been proposed as a tool to study the thermomechanical interactions related to explosive initiation. Detailed observations of the processes governing the generation of heat in these materials are severely lacking, yet they are vital for identifying salient physics, improving the modeling tools used to predict mechanical response, improving explosives safety, and providing insight into the initiation mechanisms of explosion. Here we discuss high-speed, high-resolution in-situ observations, obtained via synchrotron X-ray phase contrast imaging and diffraction, of the heating and decomposition of an explosive material under ultrasonic excitation. We demonstrate that interfacial friction is a dominant heating mechanism and can yield violent reaction of explosive particles. Moreover, sub-surface particle temperatures are estimated via diffraction.

36 MATERIALS SCIENCE↗

Use of synchrotron based diffraction enhanced imaging for visualization of soft tissues in invertebrates

Images of terrestrial and marine invertebrates (snails and bivalves) have been obtained by using an X-ray phase-contrast imaging technique, namely, synchrotron-based diffraction-enhanced imaging. Synchrotron X-rays of 20, 30 and 40 keV were used, which penetrate deep enough into animal soft tissues. The phase of X-ray photons shifts slightly as they traverse an object, such as animal soft tissue, and interact with its atoms. Biological features, such as shell morphology and animal physiology, have been visualized. The contrast of the images obtained at 40 keV is the best. This optimum energy provided a clear view of the internal structural organization of the soft tissue with better contrast. The contrast is higher at edges of internal soft-tissue structures. The image improvements achieved with the diffraction-enhanced imaging technique are due to extinction, i.e., elimination of ultra-small-angle scattering. They enabled us to identify a few embedded internal shell features, such as the origin of the apex, which is the firmly attached region of the soft tissue connecting the umbilicus to the external morphology. Diffraction-enhanced imaging can provide high-quality images of soft tissues valuable for biology.

43 PARTICLE ACCELERATORS↗

Hole number effect on spray dynamics of multi-hole diesel nozzles: An observation from three- to nine-hole nozzles

For the simplicity of optical diagnostics, studies on fuel spray and combustion characteristics of modern diesel engines have been conducted using the investigation nozzles having the reduced number of holes (two- or three-hole nozzles) compared to the production nozzles. However, the similarity of spray dynamics between the investigation nozzles and production nozzles has not been confirmed yet. Also, the hole number effect on spray dynamics has been investigated only in a limited range of hole number making it difficult to derive the clear trend and understandings of the hole number effect. In this study, the hole number effect on spray dynamics of multi-hole diesel nozzles has been investigated in a wide range of hole number with sufficient data points (three, five, six, eight, nine-hole) by using the X-ray Phase-Contrast Imaging technique. The non-linear trend in the spray structure, as well as the dynamics results, was observed as increasing the hole number regardless of injection pressure. Discussions were made accordingly to understand the observed result trend. In conclusion, the study suggests that great attention is needed when deciding the number of nozzle holes for the optimized engine combustion.

42 ENGINEERING↗

Quantitative phase retrieval with picosecond X-ray pulses from the ATF Inverse Compton Scattering source

Quantitative phase retrieval is experimentally demonstrated using the Inverse Compton Scattering X-ray source available at the Accelerator Test Facility (ATF) in the Brookhaven National Laboratory. Phase-contrast images are collected using in-line geometry, with a single X-ray pulse of approximate duration of one picosecond. The projected thickness of homogeneous samples of various polymers is recovered quantitatively from the time-averaged intensity of transmitted X-rays. The data are in good agreement with the expectations showing that ATF Inverse Compton Scattering source is suitable for performing phase-sensitive quantitative X-ray imaging on the picosecond scale. The method shows promise for quantitative imaging of fast dynamic phenomena.

43 PARTICLE ACCELERATORS↗

Effect of the number and position of nozzle holes on in- and near-nozzle dynamic characteristics of diesel injection

Despite the fact that all modern diesel engines use multi-hole injectors, single-hole injectors are frequently used to understand the fundamental properties of high-pressure diesel injections due to their axisymmetric design of the injector nozzles. A multi-hole injector accommodates many holes around the nozzle axis to deliver adequate amount of fuel with small orifices. The off-axis arrangement of the multi-hole injectors significantly alters the inter- and near-nozzle flow patterns compared to those of the single-hole injectors. This study compares the transient needle motion and near-nozzle flow characteristics of the single- and multi-hole (3-hole and 6-hole) diesel injectors to understand how the difference in hole arrangement and number affects the initial flow development of the diesel injectors. A propagation-based X-ray phase-contrast imaging technique was applied to compare the transient needle motion and near-nozzle flow characteristics of the single- and multi-hole injectors. The comparisons were made by dividing the entire injection process by three sub-stages: opening-transient, quasi-steady and closing-transient. (C) 2015 Elsevier Ltd. All rights reserved.

42 ENGINEERING↗

The effect of loading direction on the fracture behaviors of cortical bone at a dynamic loading rate

Here, the dynamic cracking processes in porcine cortical bone were visualized in real-time using the high-speed synchrotron X-ray phase-contrast imaging (PCI) technique in three osteon orientations: in-plane transverse, out-of-plane transverse and in-plane longitudinal. The dynamic flexural loading applied on the pre-notched bone specimens was introduced by a modified Kolsky compression bar. High-speed X-ray images of the entire loading events were documented with a high-speed camera. Three-dimensional X-ray micro-computed tomography was conducted to examine the intact microstructures and obtain the basic material properties of the bone material used for mechanical characterizations. The onset location, where crack initiated, and the subsequent direction, along which the incipient crack propagated, were measured quantitatively using the high-speed X-ray images and the latter was found dependent on the osteon direction significantly. The crack propagation velocities were dependent on crack extension over the entire crack path significantly for all the three directions while the initial velocity for in-plane longitudinal direction was lower than the other two directions. Straight-through crack paths were observed for in-plane longitudinal specimens while the cracks were deflected and twisted in the in-plane transverse direction. For out-of-plane transverse direction, the cracks follow paths with tortuosity fall in between the other two directions, showing a mixed mode of fractures of the former two extreme cases. The toughening mechanisms, visualized by the high-speed X-ray images, and the corresponding fracture toughness, evaluated in terms of fracture initiation toughness and crack growth resistance curve (R-curve), were also found significantly different among the three osteon directions, suggesting an overall transition from brittle to ductile-like fracture behaviors at the dynamic displacement rate (5.4 m/s) as the osteon orientation varies from in-plane longitudinal to out-of-plane transverse, and to in-plane transverse eventually.

42 ENGINEERING↗

TU-F-12A-05: Sensitivity of Textural Features to 3D Vs. 4D FDG-PET/CT Imaging in NSCLC Patients

Purpose: Neighborhood Gray-level difference matrices (NGLDM) based texture parameters extracted from conventional (3D) 18F-FDG PET scans in patients with NSCLC have been previously shown to associate with response to chemoradiation and poorer patient outcome. However, the change in these parameters when utilizing respiratory-correlated (4D) FDG-PET scans has not yet been characterized for NSCLC. The Objectives: of this study was to assess the extent to which NGLDM-based texture parameters on 4D PET images vary with reference to values derived from 3D scans in NSCLC. Methods: Eight patients with newly diagnosed NSCLC treated with concomitant chemoradiotherapy were included in this study. 4D PET scans were reconstructed with OSEM-IR in 5 respiratory phase-binned images and corresponding CT data of each phase were employed for attenuation correction. NGLDM-based texture features, consisting of coarseness, contrast, busyness, complexity and strength, were evaluated for gross tumor volumes defined on 3D/4D PET scans by radiation oncologists. Variation of the obtained texture parameters over the respiratory cycle were examined with respect to values extracted from 3D scans. Results: Differences between texture parameters derived from 4D scans at different respiratory phases and those extracted from 3D scans ranged from −30% to 13% for coarseness, −12% to 40% for contrast, −5% to 50% for busyness, −7% to 38% for complexity, and −43% to 20% for strength. Furthermore, no evident correlations were observed between respiratory phase and 4D scan texture parameters. Conclusion: Results of the current study showed that NGLDM-based texture parameters varied considerably based on choice of 3D PET and 4D PET reconstruction of NSCLC patient images, indicating that standardized image acquisition and analysis protocols need to be established for clinical studies, especially multicenter clinical trials, intending to validate prognostic values of texture features for NSCLC.

60 APPLIED LIFE SCIENCES↗

Assessment of Dynamic Fracture in Ultra-High Performance Concrete Using Synchrotron X-ray Source

Ultra-high-performance concretes (UHPCs) retain higher ultimate (compressive) strengths and greater durability relative to traditional concrete materials. As a result, they are enabling construction materials for blast resistant structures, where a higher capacity for energy absorption is required. In past investigations, the strength of UHPCs was shown to retain a dependency on strain rate. Still, the failure mechanisms which govern this rate dependency have yet to be completely elucidated. In the current study, the dynamic fracture behavior of Cor-tuf UHPC was assessed, in-situ, using a Synchrotron X-ray source in phase contrast imaging (PCI) mode. Prior to testing, the material’s morphology was characterized using X-ray computed tomography (CT) and scanning electron microscopy (SEM). A polychromatic pulsed X-ray source, high-speed camera and Kolsky bar apparatus were used in tandem, to observe the transient failure modes. A pin was placed at the end of the incident bar to control the location of damage initiation, and tests were performed at a constant velocity of ~6 m/s. These test conditions were observed to yield cracks with median and/or cone like geometries. Despite the variation in the crack paths, a significant difference in peak load was not observed. The failure mode was also observed to depend on the microstructure of the concrete samples.

Kolsky bar↗

Crack nucleation and growth during dynamic indentation of chemically-strengthened glass

Dynamic point impact loading is a primary cause of fracture of glass screens on mobile devices. An improved understanding of crack initiation and evolution under high-speed indentation could contribute to the development of materials with better performance, but experimental observations are challenging due to the short timescales and limited depth-of-field of optical microscopy. To address this need, we have observed fracture of a chemically-strengthened glass during dynamic indentation using in situ x-ray phase-contrast imaging (XPCI). Median cracks initiate below the surface of the glass, at a depth approximately corresponding to the depth at which the surface residual compressive stress diminishes to zero. These cracks initially propagate at ~10ms –1 , rapidly accelerating to > 100ms –1 . We also observe some evidence for rate-dependent behavior, in that indentation at the lowest rates studied here (below about ~0.15ms –1 ) fails to initiate cracks regardless of the depth of the indentation (up to 18μm), while indentation at higher rates produces median cracks that either arrest or cause complete fracture, depending on the depth of indentation.

36 MATERIALS SCIENCE↗

Low Temperature and Surfactant-Free Hydrothermal Synthesis of CoNi Nanoparticles: Structure, Microstructure, and Magnetic Properties

We report on the synthesis of Co{sub 30}Ni{sub 70} nanoparticles using hydrothermal method at low temperatures and short times (100 °C, 2 h) without any surfactant or external magnetic field. The effect of NaOH concentration on the crystal structure, microstructure, and magnetic properties of CoNi samples has been investigated by x-ray diffraction (XRD), scanning (SEM) and high-resolution transmission (HRTEM) electron microscopy, and vibrating sample magnetometry (VSM). From the Rietveld refinement of x-ray powder diffraction patterns, we have evidenced the coexistence of two phases with face-centered cubic (FCC) and hexagonal (HCP) crystal structures, being 12 nm and 3 nm, respectively, the values for the mean grain size of both phases. SEM images show that the basic microstructure is composed of quasi-spheres and a chain-like morphology appears with increasing the amount of NaOH. HRTEM images evidence the formation of such chains, and confirm the coexistence of FCC and HCP phases. The magnetic hysteresis loops show a clear dependence of the coercivity on the particle morphology indicating the role played by the magnetic shape anisotropy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗