Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

High Z particle Apollo astronaut dosimetry with plastics

On Apollo missions, the individual astronauts' high Z particle exposure is measured by means of Lexan polycarbonate plastic. These layers form one component of the passive dosimetry packets worn in the constant wear garment. They serve as threshold type, high Z, charged particle track detectors, recording only the very highly ionizing particles. The detectors yield information on the particles' charge, energy, and direction of travel. This data, in turn, is used to obtain the track fluence, the stopping particle density as an integral Z distribution, and the particles' integral LET spectrum. Some of the data gathered on Apollo missions 8-13 is presented.

Benton, E. V.↗

Search for new particles in events with one lepton and missing transverse momentum in pp collisions at $ \sqrt{s} $ = 8 TeV with the ATLAS detector

This paper presents a search for new particles in events with one lepton (electron or muon) and missing transverse momentum using 20.3 fb -1 of proton-proton collision data at $ \sqrt{s} $ = 8 TeV recorded by the ATLAS experiment at the Large Hadron Collider. No significant excess beyond Standard Model expectations is observed. A W' with Sequential Standard Model couplings is excluded at the 95% confidence level for masses up to 3.24 TeV. Excited chiral bosons (W*) with equivalent coupling strengths are excluded for masses up to 3.21 TeV. In the framework of an effective field theory limits are also set on the dark matter-nucleon scattering cross-section as well as the mass scale M* of the unknown mediating interaction for dark matter pair production in association with a leptonically decaying W.[Figure not available: see fulltext.]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction And Identification Of Heavy Long-Lived Particles At The ATLAS Detector At The LHC

Long-lived charged particles are predicted by many models of physics beyond the Standard Model (SM). At the LHC, the common signature would be a heavy long-lived charged particle with velocity smaller than the speed of light, beta<1. This paper presents methods we developed for identifying slow particles and measuring their mass using the ATLAS muon spectrometer. The efficacy of these methods is demonstrated using two different models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of multi-particle azimuthal correlations in pp, p + Pb and low-multiplicity Pb + Pb collisions with the ATLAS detector

Multi-particle cumulants and corresponding Fourier harmonics are measured for azimuthal angle distributions of charged particles in pp collisions at $\sqrt{s}$ = 5.02 and 13 TeV and in p + Pb collisions at $\sqrt{s}$$_ {NN}$ = 5.02 TeV, and compared to the results obtained for low-multiplicity Pb + Pb collisions at $\sqrt{s}$$_ {NN}$ = 2.76 TeV. These measurements aim to assess the collective nature of particle production. The measurements of multi-particle cumulants confirm the evidence for collective phenomena in p + Pb and low-multiplicity Pb + Pb collisions. On the other hand, the pp results for four-particle cumulants do not demonstrate collective behaviour, indicating that they may be biased by contributions from non-flow correlations. A comparison of multi-particle cumulants and derived Fourier harmonics across different collision systems is presented as a function of the charged-particle multiplicity. For a given multiplicity, the measured Fourier harmonics are largest in Pb + Pb, smaller in p + Pb and smallest in pp collisions. Finally, the pp results show no dependence on the collision energy, nor on the multiplicity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Galactic cosmic ray exposure estimates for SAGE-3 mission in polar orbit

An analysis of the effects of galactic cosmic ray (GCR) exposures on charge-coupled devices (CCDs) was performed for the SAGE-III 5-year mission in sun-synchronous orbit between 1996 and 2001. A detailed environment model used in conjunction with a geomagnetic vertical cut-off code provides the predicted 5-year fluence of GCR ions. A computerized solid model of the spacecraft was used to define the effective shield thickness distribution around the CCD detector. The particle fluences at the detector location are calculated with the Langley heavy-ion transport code, and these fluences are used in conjunction with estimated nuclear stopping powers to evaluate dosimetric quantities related to the detector degradation. A previous study analyzing effects of trapped particle and solar flare protons indicated an approximate 20 percent reduction in detector sensitivity for the mission. The galactic cosmic ray contribution was thought to be relatively small and therefore was not previously analyzed. The present study provides quantification of the GCR effects, which are found to contribute less than 1 percent of the total environment degradation.

Nealy, John E.↗

Radiation damage of germanium detectors

Energetic particles can produce interstitial-vacancy pairs in a crystal by knocking the atoms from their normal positions. Detectors are unique among semiconductor devices in depending on very low concentrations of electrically active impurities, and also on efficient transport of holes and electrons over relatively large distances. Because the dense regions of damage produced by energetic particles may result in donors and/or acceptors, and also provide trapping sites for holes and electrons, detectors are very sensitive to radiation damage. In addition to these effects occurring within the detector, radiation may also change the characteristics of the exposed surfaces causing unpredictable effects on the detector leakage current. Radiation-induced surface degradation has rarely, if ever, been observed for germanium detectors. The possibility of minimizing hole trapping in charge collection by the use of a high-purity germanium coaxial detector configured with the p (+) contact on the coaxial periphery is discussed.

Pehl, R. H.↗

ElectroMon Geometry Considerations: Simulations of Electron Transport to a Diamond-Based Detector

Particle-in-Cell simulations were performed to investigate the effects of electrode bias and pitch on the expected number of electrons arriving at a diamond-based detector at a set of relevant incident electron energies for electron cloud monitoring. Results of these simulations indicate that the pitch of the electrodes directly impacts the number of incident electrons based on complete opacity of the electrodes to the electrons; image charge does not play a role at any relevant electron energy. Positive bias on the incident electrodes directly increases the energy of the incident electrons, while negative bias reduces the energy and completely repels incoming electrons of energies lower than the applied bias. These results are intended to be used as input parameters for a solid-state simulation which will determine the collection efficiency of the electron-hole pairs produced within the diamond as a function of position and energy.

43 PARTICLE ACCELERATORS↗

Particulate and aerosol detector

Particulate detector which monitors emissions from solid propellant fuels can monitor air quality. High signal-to-noise ratio detector can count aerosols and particles efficiently. Detector can distinguish one particle from another with respect to both time and energy of impact. Detector consists of accelerator, capacitor sensor, and readout recording equipment.

Kinard, W. H.↗

On-chip probabilistic inference for charged-particle tracking at the sensor edge

Modern scientific instruments operate under increasingly extreme constraints on bandwidth, latency, and power. Inference at the sensor edge determines experimental data collection efficiency by deciding which information to save for further analysis. Particle tracking detectors at the Large Hadron Collider exemplify this challenge: pixelated silicon sensors generate rich spatiotemporal ionization patterns, yet most of this information is discarded due to data-rate limitations. Concurrently, advancements in co-design tools provide rapid turn-around for incorporating machine learning into application-specific integrated circuits, motivating designs for particle detectors with new integrated technologies. We demonstrate that neural networks embedded in the front-end electronics can infer charged-particle kinematic parameters from a single silicon layer. We regress hit positions and incident angles with calibrated uncertainties, while satisfying stringent constraints on numerical precision, latency, and silicon area. Our results establish a path toward probabilistic inference directly at the edge, opening new opportunities for intelligent sensing in high-rate scientific instruments.

Das, Arghya Ranjan [Purdue U.] (ORCID:000000018451↗

3D Integrated Sensing Solutions

We will present the proposed research project to develop 3D-integrated sensors using advanced manufacturing capability for novel sensors, heterogeneously integrated with energy efficient readout circuits. The lack of precision timing in particle tracking detectors and the absence of low power, high throughput communications solutions to read them out limits progress in multiple fields of fundamental science. The aim of the project is to develop technology to enable large-scale particle detectors with 3D-integrated ASIC designs to simultaneously achieve 10 μm position resolution and 10 ps precision timing, with low-power consumption and high throughput rates. This research program leverages the unique combination of facilities and cross-disciplinary expertise of scientists and engineers at SLAC, FNAL, and LLNL and industrial partners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle showers detected on ISS in Timepix pixel detectors

We detect regular particle showers in several compact pixel detectors, distributed over the International Space Station. These showers are caused by high energy galactic cosmic rays, with energies often in the 10 s of TeV or higher. We survey the frequency of these events, their dependence on location on ISS, and their independence of the location of ISS, on its orbit. The Timepix detectors used allow individual particle tracks to be resolved, providing a possibility to perform physical analysis of shower events, which we demonstrate. In terms of radiation dosimetry, these showers indicate certain possible limitations of traditional dosimetric measures, in that (a) the dose measured in small sensor may be less than that received in a larger distribution of matter, such as a human and (b) the spatial and temporal extent of these events represents a regime of poorly documented biological response.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for invisible particles produced in association with single-top-quarks in proton–proton collisions at √s = 8 TeV with the ATLAS detector

A search for the production of single-top-quarks in association with missing energy is performed in proton–proton collisions at a centre-of-mass energy of √s=8 TeV with the ATLAS experiment at the large hadron collider using data collected in 2012, corresponding to an integrated luminosity of 20.3 fb -1 . In this study, the W boson from the top quark is required to decay into an electron or a muon and a neutrino. No deviation from the standard model prediction is observed, and upper limits are set on the production cross-section for resonant and non-resonant production of an invisible exotic state in association with a right-handed top quark. In the case of resonant production, for a spin-0 resonance with a mass of 500 GeV, an effective coupling strength above 0.15 is excluded at 95% confidence level for the top quark and an invisible spin-1/2 state with mass between 0 and 100 GeV. In the case of non-resonant production, an effective coupling strength above 0.2 is excluded at 95% confidence level for the top quark and an invisible spin-1 state with mass between 0 and 657 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-F-16A-04: Micro-Irradiator Treatment Verification with High-Resolution 3D-Printed Rodent-Morphic Dosimeters

Purpose: Pre-clinical micro-radiation therapy studies often utilize very small beams (∼0.5-5mm), and require accurate dose delivery in order to effectively investigate treatment efficacy. Here we present a novel high-resolution absolute 3D dosimetry procedure, capable of ∼100-micron isotopic dosimetry in anatomically accurate rodent-morphic phantoms Methods: Anatomically accurate rat-shaped 3D dosimeters were made using 3D printing techniques from outer body contours and spinal contours outlined on CT. The dosimeters were made from a radiochromic plastic material PRESAGE, and incorporated high-Z PRESASGE inserts mimicking the spine. A simulated 180-degree spinal arc treatment was delivered through a 2 step process: (i) cone-beam-CT image-guided positioning was performed to precisely position the rat-dosimeter for treatment on the XRad225 small animal irradiator, then (ii) treatment was delivered with a simulated spine-treatment with a 180-degree arc with 20mm x 10mm cone at 225 kVp. Dose distribution was determined from the optical density change using a high-resolution in-house optical-CT system. Absolute dosimetry was enabled through calibration against a novel nano-particle scintillation detector positioned in a channel in the center of the distribution. Results: Sufficient contrast between regular PRESAGE (tissue equivalent) and high-Z PRESAGE (spinal insert) was observed to enable highly accurate image-guided alignment and targeting. The PRESAGE was found to have linear optical density (OD) change sensitivity with respect to dose (R{sup 2} = 0.9993). Absolute dose for 360-second irradiation at isocenter was found to be 9.21Gy when measured with OD change, and 9.4Gy with nano-particle detector- an agreement within 2%. The 3D dose distribution was measured at 500-micron resolution Conclusion: This work demonstrates for the first time, the feasibility of accurate absolute 3D dose measurement in anatomically accurate rat phantoms containing variable density PRESAGE material (tissue equivalent and bone equivalent). This method enables precise treatment verification of micro-radiation therapies, and enhances the robustness of tumor radio-response studies. This work was supported by NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

Silicon Detectors-Tools for Discovery in Particle Physics

Since the first application of Silicon strip detectors in high energy physics in the early 1980ies these detectors have enabled the experiments to perform new challenging measurements. With these devices it became possible to determine the decay lengths of heavy quarks, for example in the fixed target experiment NA11 at CERN. In this experiment Silicon tracking detectors were used for the identification of particles containing a c-quark. Later on, the experiments at the Large Electron Positron collider at CERN used already larger and sophisticated assemblies of Silicon detectors to identify and study particles containing the b-quark. A very important contribution to the discovery of the last of the six quarks, the top quark, has been made by even larger Silicon vertex detectors inside the experiments CDF and D0 at Fermilab. Nowadays a mature detector technology, the use of Silicon detectors is no longer restricted to the vertex regions of collider experiments. The two multipurpose experiments ATLAS and CMS at the Large Hadron Collider at CERN contain large tracking detectors made of Silicon. The largest is the CMS Inner Tracker consisting of 200 m{sup 2} of Silicon sensor area. These detectors will be very important for a possible discovery of the Higgs boson or of Super Symmetric particles. This paper explains the first applications of Silicon sensors in particle physics and describes the continuous development of this technology up to the construction of the state of the art Silicon detector of CMS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Long-Lived Particles Decaying into Electron or Photon Pairs with the D0 Detector

In this Letter we report on a search for long-lived particles that decay into final states with two electrons or photons. Such long-lived particles arise in a variety of theoretical models, such as hidden valleys and supersymmetry with gauge-mediated breaking. By precisely reconstructing the direction of the electromagnetic shower we are able to probe much longer lifetimes than previously explored. We see no evidence of the existence of such long-lived particles and interpret this search as a quasi model-independent limit on their production cross section, as well as a limit on a long-lived fourth generation quark.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for heavy charged long-lived particles in the ATLAS detector in 31.6 fb &#x2212; 1 of proton-proton collision data at s = 13 TeV

CERN-LHC. Search for heavy charged long-lived particles in the ATLAS detector in 36.1/fb of proton-proton collision data at sqrt(s) = 13 TeV. A search for heavy charged long-lived particles is performed using a data sample of 36.1/fb of proton-proton collisions at sqrt(s) = 13 TeV collected by the ATLAS experiment at the Large Hadron Collider. The search is based on observables related to ionization energy loss and time of flight, which are sensitive to the velocity of heavy charged particles traveling significantly slower than the speed of light. Multiple search strategies for a wide range of lifetimes, corresponding to path lengths of a few meters, are defined as model-independently as possible, by referencing several representative physics cases that yield long-lived particles within supersymmetric models, such as gluinos/squarks (R-hadrons), charginos and staus. No significant deviations from the expected Standard Model background are observed. Upper limits at 95% confidence level are provided on the production cross sections of long-lived R-hadrons as well as directly pair-produced staus and charginos. These results translate into lower limits on the masses of long-lived gluino, sbottom and stop R-hadrons, as well as staus and charginos of 2000 GeV, 1250 GeV, 1340 GeV, 430 GeV and 1090 GeV, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Constraints on Axionlike Particles with the NEON Detector at a Nuclear Reactor

We report new constraints on axionlike particles (ALPs) using data from the NEON experiment, which features 16.7 kg of NaI(Tl) target located 23.7 m from a 2.8 GW thermal power nuclear reactor. Analyzing a total exposure of 3063 kg · day , with 1596 kg · day during reactor-on and 1467 kg · day during reactor-off periods, we compared energy spectra to search for ALP-induced signals. No significant signal was observed, enabling us to set exclusion limits at the 95% confidence level. These limits probe previously unexplored regions of the ALP parameter space, particularly for axion masses ( m a ) near 1 MeV / c 2 . For ALP-photon coupling ( g a γ ), limits reach as low as 6.24 × 10 − 6 GeV − 1 at m a = 3.0 MeV / c 2 , while for ALP-electron coupling ( g a e ), limits reach 4.95 × 10 − 8 at m a = 1.02 MeV / c 2 . This Letter demonstrates the potential for future reactor experiments to probe unexplored ALP parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Testing MeV dark matter with neutrino detectors

MeV particles have been advocated as dark matter (DM) candidates in different contexts. This hypothesis can be tested indirectly by searching for the standard model (SM) products of DM self-annihilations. As the signal from DM self-annihilations depends on the square of the DM density, we might expect a sizable flux of annihilation products from our galaxy. Neutrinos are the least detectable particles in the SM and a null signal in this channel would allow to set the most conservative bound on the total annihilation cross section. Here, we show that neutrino detectors with good energy resolution and low energy thresholds can not only set bounds on the annihilation cross section but actually test the hypothesis of the possible existence of MeV DM, i.e. test the values of the cross section required to explain the observed DM density. At present, the data in the (positron) energy interval [18-82] MeV of the Super-Kamiokande experiment is already able to put a very stringent bound on the annihilation cross section for masses between {approx}15-130 MeV. Future large experiments, like megaton water-Cerenkov or large scintillator detectors, will improve the present limits and, if MeV DM exists, would be able to detect it.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗