Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particulates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

An Analysis of Degradation in Low-Cost Particulate Matter Sensors

Low-cost sensors (LCSs) are increasingly being used to measure fine particulate matter (PM 2.5 ) concentrations in cities around the world. One of the most commonly deployed LCSs is PurpleAir with ∼15 000 sensors deployed in the United States, alone. PurpleAir measurements are widely used by the public to evaluate PM 2.5 levels in their neighborhoods. PurpleAir measurements are also increasingly being integrated into models by researchers to develop large-scale estimates of PM 2.5 . However, the change in sensor performance over time has not been well studied. It is important to understand the lifespan of these sensors to determine when they should be serviced or replaced, and when measurements from these devices should or should not be used for various applications. This paper fills this gap by leveraging the fact that: (1) each PurpleAir sensor is composed of two identical sensors and the divergence between their measurements can be observed, and (2) there are numerous PurpleAir sensors within 50 meters of regulatory monitors allowing for the comparison of measurements between these instruments. We propose empirically-derived degradation outcomes for the PurpleAir sensors and evaluate how these outcomes change over time. On average, we find that the number of ‘flagged’ measurements, where the two sensors within each PurpleAir sensor disagree, increases with time to ∼4% after 4 years of operation. Approximately, 2 percent of all PurpleAir sensors were permanently degraded. The largest fraction of permanently degraded PurpleAir sensors appeared to be in the hot and humid climate zone, suggesting that sensors in these locations may need to be replaced more frequently. We also find that the bias of PurpleAir sensors, or the difference between corrected PM2.5 levels and the corresponding reference measurements, changed over time by −0.12 μg m −3 (95% CI: −0.13 μg m −3 , −0.10 μg m −3 ) per year. The average bias increases dramatically after 3.5 years. Further, climate zone is a significant modifier of the association between degradation outcomes and time.

Priyanka deSouza↗

Investigating Drivers of Particulate Matter Pollution Over India and the Implications for Radiative Forcing With GEOS-Chem-TOMAS15

Ambient fine particulate matter (PM 2.5 ) concentrations in India frequently exceed 100 μg/m 3 during fall and winter pollution episodes. We use the GEOS-Chem chemical transport model with the TwO-Moment Aerosol Sectional microphysics scheme with 15 size bins (TOMAS15) to assess PM 2.5 composition and impacts on radiation and cloud condensation nuclei (CCN) during pollution episodes as compared to the seasonal (October-December) average. We conduct high resolution (0.25° × 0.3125°) nested-domain simulations over India for short-duration, high-PM2.5 episodes in the fall of 2015 and 2017. The simulations capture the magnitude and spatial patterns of pollution episodes measured by surface monitors (r PM2.5 = 0.69) although aerosol optical depth is underestimated. During the episodes, near-surface organic matter (OM), black carbon (BC), and secondary inorganic aerosol concentrations increase from seasonal averages by up to 36, 7, and 7 μg/m 3 , respectively. Episodic aerosol increases enhance cooling by lowering the top-of-atmosphere clear-sky direct radiative effect (DRE TOA ) during the 2015 episode (−6 W/m 2 ), with a smaller impact during the 2017 episode (−1 W/m 2 ). Differences in DRE TOA reflect larger increases in scattering aerosols in the column during the 2015 episode (+17 mg/m 2 ) than in 2017 (+13 mg/m 2 ), while absorbing aerosol column enhancements are smaller (+3 mg/m2) in both years. Changes in shortwave radiation at the surface (SW sfc ) are spatially similar to DRE TOA and mostly negative during both episodes. CCN enhancements (0.2% supersaturation) during these episodes occur across the western Indo-Gangetic Plain, coincident with higher PM 2.5 concentrations. Changes in DRE TOA , SW sfc , and CCN during high-PM 2.5 episodes may have implications for crops, the hydrologic cycle, and surface temperature.

PM2.5↗

Contrails Measurement and Testing Capabilities in NASA's Particulate Aerosol Laboratory

The NASA Glenn Research Center Particulate Aerosol Laboratory (PAL) is a ground test facility for studying emissions and contrails at upper atmospheric conditions. The facility consists of a small-scale combustor that generates hot combustion gases and soot nanoparticles, which flow through a transition pipe into a jet nozzle, which exhausts into an altitude chamber. Thermodynamic conditions experienced in flight are matched in the altitude chamber, allowing the study of ice particle formation of simulated aircraft engine exhaust plumes. A non-intrusive optical diagnostic technique based on Mie scattering provides ice particle size, number density, and mass density. A suite of commercial extractive particle measurement instruments provides estimates of soot number density, size, and black carbon mass distributions. Measurements are presented for various fuels at chamber conditions covering an altitude range of 20,000 ft (6 km) to 45,000 ft (14 km) altitude and ambient temperatures from -48°C to -68°C. The data presented demonstrate the effect of soot number density, altitude, and fuel-to-air equivalence ratio on the contrail ice particle formation. Ice mass density measurements are compared to values predicted by a thermodynamic plume similarity solution.

Optical Instrumentation↗

A Dynamic Testing Approach for Particulate Erosion–Corrosion for Gas Turbine Coatings

Particle interactions in gas turbine engines can be multicomponent, complex phenomena leading to the degradation of thermal (TBCs) and environmental barrier coatings (EBCs) meant to protect engine components. Ingestion of particles into the engine can lead to recession of coatings due to particle erosion. Similarly, these same particles can become molten, adhere to coatings and result in thermochemical corrosion of coating materials. Particle erosion testing is often carried out where the particles are injected into a gas stream, accelerated within a nozzle, and impinge on sample. Conversely, most molten particle corrosion testing is often done in static laboratory furnaces, which does not capture the dynamic nature of deposition in application. Nevertheless, these damage mechanisms are often tested separately and no single standard exists to test both erosive and corrosive particle interactions with coating materials under relevant operating conditions for gas turbine engines. Understanding the synergies of particle interactions in engines is crucial in determining operating lifetimes of potential coating materials. Such considerations emphasize the need for realistic approaches in standardizing particle interaction testing in combustion environments. The current study outlines initial efforts at NASA Glenn’s Erosion Burner Rig Facility in improving dynamic erosion/corrosion testing methods by assessing the durability of state-of-the-art (SOA) TBC material 7 wt.% yttria stabilized zirconia (7YSZ) as a function of particle deposition rate, burner temperature, and particle size. Calibration data to determine particle deposition rate will be presented, and mass and optical profilometry measurements were utilized to estimate mass/volume loss versus deposition per increment of particulate used over time. Electron microscopy analyses were then carried out to assess coating damage after testing.

TBC↗

A Dynamic Testing Approach for Particulate Erosion–Corrosion for Gas Turbine Coatings

Particle interactions in gas turbine engines can be multicomponent, complex phenomena leading to the degradation of thermal (TBCs) and environmental barrier coatings (EBCs) meant to protect engine components. Ingestion of particles into the engine can lead to recession of coatings due to particle erosion. Similarly, these same particles can become molten, adhere to coatings and result in thermochemical corrosion of coating materials. Particle erosion testing is often carried out where the particles are injected into a gas stream, accelerated within a nozzle, and impinge on sample. Conversely, most molten particle corrosion testing is often done in static laboratory furnaces, which does not capture the dynamic nature of deposition in application. Nevertheless, these damage mechanisms are often tested separately and no single standard exists to test both erosive and corrosive particle interactions with coating materials under relevant operating conditions for gas turbine engines. Understanding the synergies of particle interactions in engines is crucial in determining operating lifetimes of potential coating materials. Such considerations emphasize the need for realistic approaches in standardizing particle interaction testing in combustion environments. The current study outlines initial efforts at NASA Glenn’s Erosion Burner Rig Facility in improving dynamic erosion/corrosion testing methods by assessing the durability of state-of-the-art (SOA) TBC material 7 wt.% yttria stabilized zirconia (7YSZ) as a function of particle deposition rate, burner temperature, and particle size. Calibration data to determine particle deposition rate will be presented, and mass and optical profilometry measurements were utilized to estimate mass/volume loss versus deposition per increment of particulate used over time. Electron microscopy analyses were then carried out to assess coating damage after testing.

TBC↗

The Impact of Decarbonization on Particulate Soiling of Solar Panels

Climate researchers have examined many impacts of climate change on energy supply and demand under various scenarios. However, the effect of changing particulate deposition onto solar panel surfaces on solar power production efficiency (i.e., soiling) has not been studied. We therefore characterize probabilistic outcomes across multiple climate models and scenarios. We find large current regional losses (up to 40% without manual cleaning, up to 20% with monthly cleaning and rain removal) in generation that grow slightly under a high-emission scenario, largely due to regional increases in windblown dust. In contrast, under a low-emissions scenario, potential production increases significantly (2–8% interquartile range with only rain removal) due to reduced soiling, especially in regions of Asia and Africa where anthropogenic aerosols are major contributors to soiling. Projected changes vary widely across models in many dusty areas outside of the Sahara and Arabia. Differences can also be large in regions dominated by anthropogenic aerosols, such as Nigeria, eastern China, and northern India, where the full range across modeled potential power production changes extends from −1 to +11% for the end of the century (without manual cleaning), underscoring the need to consider multiple climate models. With large increases in projected solar power deployment, the relatively small potential production increases reported here could nevertheless represent a large dividend in additional energy production. Hence, reductions in air pollution attributable to decarbonization could provide positive feedback under which a greater deployment of solar power (or other renewables) increases the production of solar power, facilitating the transition to renewable energy.

renewable energy↗

A Dynamic Testing Approach for Particulate Erosion–Corrosion for Gas Turbine Coatings

Particle interactions in gas turbine engines can be multicomponent, complex phenomena leading to the degradation of thermal (TBCs) and environmental barrier coatings (EBCs) meant to protect engine components. Ingestion of particles into the engine can lead to recession of coatings due to particle erosion. Similarly, these same particles can become molten, adhere to coatings and result in thermochemical corrosion of coating materials. Particle erosion testing is often carried out where the particles are injected into a gas stream, accelerated within a nozzle, and impinge on sample. Conversely, most molten particle corrosion testing is often done in static laboratory furnaces, which does not capture the dynamic nature of deposition in application. Nevertheless, these damage mechanisms are often tested separately and no single standard exists to test both erosive and corrosive particle interactions with coating materials under relevant operating conditions for gas turbine engines. Understanding the synergies of particle interactions in engines is crucial in determining operating lifetimes of potential coating materials. Such considerations emphasize the need for realistic approaches in standardizing particle interaction testing in combustion environments. The current study outlines initial efforts at NASA Glenn’s Erosion Burner Rig Facility in improving dynamic erosion/corrosion testing methods by assessing the durability of state-of-the-art (SOA) TBC material 7 wt.% yttria stabilized zirconia (7YSZ) as a function of particle deposition rate, burner temperature, and particle size. Calibration data to determine particle deposition rate will be presented, and mass and optical profilometry measurements were utilized to estimate mass/volume loss versus deposition per increment of particulate used over time. Electron microscopy analyses were then carried out to assess coating damage after testing.

burner rig↗

Influence of Processing Parameters on the Mechanical Properties of 3D Printed Borosilicate Particulate Reinforced Polymer Composites

Emerging composite materials are expanding the potential of additive manufacturing and enabling applications previously restricted by traditional manufacturing methods. The multi-phase nature of these composite materials combined with the complex in-ternal geometry of additively manufactured parts have enabled unique behavior, and potentially new applications. Additionally, these materials can be pyrolyzed to create dense metal, ceramic, and glass parts with geometries typically not achievable by tra-ditional processes. Additive manufacturing of borosilicate glass-based systems can open new applications in nuclear engineering, astronomy, and bone regrowth therapy. To elucidate the process-parameter relationship of borosilicate-polylactic acid (PLA) composites, mechanical testing was conducted and compared with a pure polylactic acid polymer baseline. Test specimens were fabricated by fused-filament fabrication with minimal post-processing. Yield strength, ultimate strength, and elastic modulus were calculated from stress-strain curves. Optical and scanning electron microscopy were conducted to observe the specimen microstructure before and after testing. The highest compressive yield strength for the composite was 28.22 MPa, and the highest compressive yield strength for PLA was 49.30 MPa. Print orientation was found to benefit the composite material but have a detrimental effect on the pure matrix material. An elastic modulus of 2.66 GPa was recorded for the borosilicate-PLA composite at 100% infill, 1 shell wall, and layer lines parallel to compression axis. Microscopy revealed that lower modulus composite specimens had the particulates re-distributed within the matrix. Tensile testing was done according to a polymer testing standard, which caused difficulties obtaining consistent fracture within the gauge length.

mechanical testing↗

Microwave mode shifting antenna system for regenerating particulate filters

A regeneration system comprises a particulate matter (PM) filter including a microwave energy absorbing surface, and an antenna system comprising N antennas and an antenna driver module that sequentially drives the antenna system in a plurality of transverse modes of the antenna system to heat selected portions of the microwave absorbing surface to regenerate the PM filter, where N is an integer greater than one. The transverse modes may include transverse electric (TE) and/or transverse magnetic (TM) modes.

42 ENGINEERING↗

Overlap zoned electrically heated particulate filter

A system includes a particulate matter (PM) filter that includes an upstream end for receiving exhaust gas and a downstream end. A zoned heater is arranged spaced from the upstream end and comprises N zones, where N is an integer greater than one, wherein each of the N zones comprises M sub-zones, where M is an integer greater than or equal to one, and wherein the N zones and the M sub-zones are arranged in P layers, where P is an integer greater than one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates non-selected ones of the N zones.

47 OTHER INSTRUMENTATION↗

Ash reduction system using electrically heated particulate matter filter

A control system for reducing ash comprises a temperature estimator module that estimates a temperature of an electrically heated particulate matter (PM) filter. A temperature and position estimator module estimates a position and temperature of an oxidation wave within the electrically heated PM filter. An ash reduction control module adjusts at least one of exhaust flow, fuel and oxygen levels in the electrically heated PM filter to adjust a position of the oxidation wave within the electrically heated PM filter based on the oxidation wave temperature and position.

47 OTHER INSTRUMENTATION↗

Wireless zoned particulate matter filter regeneration control system

An assembly includes a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas, a downstream end and multiple zones. An absorbing layer absorbs microwave energy in one of N frequency ranges and is arranged with the upstream end. N is an integer. A frequency selective filter has M frequency selective segments and receives microwave energy in the N frequency ranges. M is an integer. One of the M frequency selective segments permits passage of the microwave energy in one of the N frequency ranges and does not permit passage of microwave energy in the other of the N frequency ranges.

42 ENGINEERING↗

Zoned electrical heater arranged in spaced relationship from particulate filter

A system comprises a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas and a downstream end. A zoned heater is arranged spaced from the upstream end and comprises N zones, where N is an integer greater than one, wherein each of the N zones comprises M sub-zones, where M is an integer greater than one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates non-selected ones of the N zones.

42 ENGINEERING↗

Radiant zone heated particulate filter

A system includes a particulate matter (PM) filter including an upstream end for receiving exhaust gas and a downstream end. A radiant zoned heater includes N zones, where N is an integer greater than one, wherein each of the N zones includes M sub-zones, where M is an integer greater than or equal to one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones, restricts exhaust gas flow in a portion of the PM filter that corresponds to the selected one of the N zones, and deactivates non-selected ones of the N zones.

47 OTHER INSTRUMENTATION↗

Electrically heated particulate matter filter with recessed inlet end plugs

A particulate matter (PM) filter includes filter walls having inlet ends and outlet ends. First adjacent pairs of the filter walls define inlet channels. Second adjacent pairs of the filter walls define outlet channels. Outlet end plugs are arranged in the inlet channels adjacent to the output ends. Inlet end plugs arranged in the outlet channels spaced from the inlet ends.

47 OTHER INSTRUMENTATION↗

Low exhaust temperature electrically heated particulate matter filter system

A system includes a particulate matter (PM) filter, a sensor, a heating element, and a control module. The PM filter includes with an upstream end that receives exhaust gas, a downstream end and multiple zones. The sensor detects a temperature of the exhaust gas. The control module controls current to the heating element to convection heat one of the zones and initiate a regeneration process. The control module selectively increases current to the heating element relative to a reference regeneration current level when the temperature is less than a predetermined temperature.

47 OTHER INSTRUMENTATION↗

Electrically resistive coating for remediation (regeneration) of a diesel particulate filter and method

A resistively heated diesel particulate filter (DPF). The resistively heated DPF includes a DPF having an inlet surface and at least one resistive coating on the inlet surface. The at least one resistive coating is configured to substantially maintain its resistance in an operating range of the DPF. The at least one resistive coating has a first terminal and a second terminal for applying electrical power to resistively heat up the at least one resistive coating in order to increase the temperature of the DPF to a regeneration temperature. The at least one resistive coating includes metal and semiconductor constituents.

36 MATERIALS SCIENCE↗

Elevated exhaust temperature, zoned, electrically-heated particulate matter filter

A system includes an electrical heater and a particulate matter (PM) filter that is arranged one of adjacent to and in contact with the electrical heater. A control module selectively increases an exhaust gas temperature of an engine to a first temperature and that initiates regeneration of the PM filter using the electrical heater while the exhaust gas temperature is above the first temperature. The first temperature is greater than a maximum exhaust gas temperature at the PM filter during non-regeneration operation and is less than an oxidation temperature of the PM.

47 OTHER INSTRUMENTATION↗