Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

SU-E-I-98: Dose Comparison for Pulmonary Embolism CT Studies: Single Energy Vs. Dual Energy

Purpose: The purpose of this study was to assess and compare the size specific dose estimate (SSDE), dose length product (DLP) and noise relationship for pulmonary embolism studies evaluated by single source dual energy computed tomography (DECT) against conventional CT (CCT) studies in a busy cancer center and to determine the dose savings provided by DECT. Methods: An IRB-approved retrospective study was performed to determine the CTDIvol and DLP from a subset of patients scanned with both DECT and CCT over the past five years. We were able to identify 30 breast cancer patients (6 male, 24 female, age range 24 to 81) who had both DECT and CCT studies performed. DECT scans were performed with a GE HD 750 scanner (140/80 kVp, 480 mAs and 40 mm) and CCT scans were performed with a GE Lightspeed 16 slice scanner (120 kVp, 352 mAs, 20 mm). Image noise was measured by placing an ROI and recording the standard deviation of the mean HU along the descending aorta. Results: The average DECT patient size specific dose estimate was to be 14.2 ± 1.7 mGy as compared to 22.4 ± 2.7 mGy from CCT PE studies, which is a 37% reduction in the SSDE. The average DECT DLP was 721.8 ± 84.6 mGy-cm as compared to 981.8 ± 106.1 mGy-cm for CCT, which is a 26% decrease. Compared to CCT the image noise was found to decrease by 19% when using DECT for PE studies. Conclusion: DECT SSDE and DLP measurements indicate dose savings and image noise reduction when compared to CCT. In an environment that heavily debates CT patient doses, this study confirms the effectiveness of DECT in PE imaging.

60 APPLIED LIFE SCIENCES↗

The first clinical treatment with kilovoltage intrafraction monitoring (KIM): A real-time image guidance method

Purpose: Kilovoltage intrafraction monitoring (KIM) is a real-time image guidance method that uses widely available radiotherapy technology, i.e., a gantry-mounted x-ray imager. The authors report on the geometric and dosimetric results of the first patient treatment using KIM which occurred on September 16, 2014. Methods: KIM uses current and prior 2D x-ray images to estimate the 3D target position during cancer radiotherapy treatment delivery. KIM software was written to process kilovoltage (kV) images streamed from a standard C-arm linear accelerator with a gantry-mounted kV x-ray imaging system. A 120° pretreatment kV imaging arc was acquired to build the patient-specific 2D to 3D motion correlation. The kV imager was activated during the megavoltage (MV) treatment, a dual arc VMAT prostate treatment, to estimate the 3D prostate position in real-time. All necessary ethics, legal, and regulatory requirements were met for this clinical study. The quality assurance processes were completed and peer reviewed. Results: During treatment, a prostate position offset of nearly 3 mm in the posterior direction was observed with KIM. This position offset did not trigger a gating event. After the treatment, the prostate motion was independently measured using kV/MV triangulation, resulting in a mean difference of less than 0.6 mm and standard deviation of less than 0.6 mm in each direction. The accuracy of the marker segmentation was visually assessed during and after treatment and found to be performing well. During treatment, there were no interruptions due to performance of the KIM software. Conclusions: For the first time, KIM has been used for real-time image guidance during cancer radiotherapy. The measured accuracy and precision were both submillimeter for the first treatment fraction. This clinical translational research milestone paves the way for the broad implementation of real-time image guidance to facilitate the detection and correction of geometric and dosimetric errors, and resultant improved clinical outcomes, in cancer radiotherapy.

60 APPLIED LIFE SCIENCES↗

Elemental analysis of slurry samples with laser induced breakdown spectroscopy

Direct analysis of wet slurry samples with laser induced breakdown spectroscopy (LIBS) is challenging due to problems of sedimentation, splashing, and surface turbulence. Also, water can quench the laser plasma and suppress the LIBS signal, resulting in poor sensitivity. The effect of water on LIBS spectra from slurries was investigated. As the water content decreased, the LIBS signal was enhanced and the standard deviation was reduced. To improve LIBS slurry analysis, dried slurry samples prepared by applying slurry on PVC coated slides were evaluated. Univariate and multivariate calibration was performed on the LIBS spectra of the dried slurry samples for elemental analysis of Mg, Si, and Fe. Calibration results show that the dried slurry samples give a good correlation between spectral intensity and elemental concentration.

54 ENVIRONMENTAL SCIENCES↗

The Physics of the Gas Attenuator for the Linac Coherent Light Source (LCLS)

A systematic assessment of a variety of physics issues affecting the performance of the LCLS X-ray beam attenuator is presented. Detailed analysis of the gas flow in the gas attenuator and in the apertures is performed. A lot of attention is directed towards the gas ionization and heating by intense X-ray pulses. The role of these phenomena in possible deviations of the attenuation coefficient from its “dialed in” value is evaluated and found small in most cases. Other sources of systematic and statistical errors are also discussed. The regimes where the errors may reach a few percent correspond to the lower X-ray energies (less than 2 keV) and highest beam intensities. Other effects discussed include chemical interaction of the gas with apertures, shock formation in the transonic flow in the apertures of the attenuator, generation of electromagnetic wakes in the gas, and head-to-tail variation of the attenuation caused by the ionization of gas or solid. Possible experimental tests of the consistency of the physics assumptions used in the concept of the gas attenuator are discussed. Interaction of X-rays with the solid attenuator (that will be used at higher X-ray energies, from 2.5 to 8 keV) is considered and thermo-mechanical effects caused by the beam heating are evaluated. Wave-front distortions induced by non-uniform heating of both the solid and the gas are found to be small. An overall conclusion drawn from the analysis presented is that the attenuator will be a reliable and highly versatile device, provided that some caution is exercised in its use for highest beam intensities at lowest X-ray energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Temperature Erosion Modeling in Particle Based CSP Systems

1. Introduction. Wear and erosion damage of materials from solid particle and surface interactions is a major issue in various industries. Although more common in mining and oil and gas production, erosion is becoming a critical issue in renewable technologies as well such as particle based concentrated solar thermal power (CSP) systems. In particle based CSP systems, solid particles are used to absorb solar energy and as thermal storage. However, these particles may cause significant amount of wear to system components while through the system at high temperatures. This damage can be costly, and therefore, requires a greater understanding of solid particle erosion in CSP systems. Throughout the years, models and tools have been developed to predict and control erosion in industries such as oil and gas production. However, these erosion models and erosion prediction tools have been mainly developed based on erosion data for much higher velocities and lower temperatures, i.e. the operating conditions for which the existing models have been built are not pertinent to those expected in CSP system. It is known that erosion depends on many factors such as material properties, erodent particle properties, and particle impact speed and angle. However, the effect of temperature on erosion is not vastly investigated. In this work, a temperature-based correlation is introduced that will be used to modify the existing erosion models to predict erosion rates at velocities and temperatures relevant to Gen3 CSP systems. The existing models are first validated against erosion experiments run at low temperatures and low velocities. Subsequently, a temperature correction term is developed that can extend the existing models to high temperatures, based on the available experimental data showing the effect of temperature on impact erosion. 2. Erosion Models. Continuing sequence of impacts from solid particles on surfaces would result in loss of material due to mechanical interaction between solid surface and particles. Erosion equations have been developed to predict erosion under different conditions and erosion mechanism, including cutting and deformation erosion. These models are mainly either mechanistic, empirical, and semi-mechanistic models, when the latter combine the theory of the erosion mechanism and particle motion with the available experimental data. One of the first empirical correlation was introduced by American Petroleum Institute (API) Recommended Practice (RP) 14E [1]. This correlation was very conservative, and several improved empirical and semi-mechanistic equations were developed in the years following. More recently, the models introduced by Erosion/Corrosion Research Center (E/CRC) at the University of Tulsa and Arabnejad. et al. [2] are frequently used in the literature and industry, as they account for many parameters affecting erosion including particle impact speed and angle, material density and hardness, and particle size and shape. However, both these models were developed based on data at relatively high velocities and also do not take into account any mechanical changes in material associated with thermal cycling at high temperatures. 3. Erosion Prediction at High Temperatures. In this work, the accuracy of Arabnejad et al. model and E/CRC model is investigated to predict impact erosion at conditions relevant to Gen3 CSP systems. Two significant deviations expected in Gen3 systems compared to operating conditions used to build these models are particle impact velocities and system temperature. As a first step, the performance of these models was validated at low velocities and temperatures. Impact erosion experiments were conducted on SS316 coupons using HSP 40/70 ceramic particles. Assuming particle rate of 1 kg/s/m, 0.0254 m of particle curtain thickness, and particle velocity of 1.5 m/s in the system, an overall erosion of 0.59 mm/year was calculated. The experimental results were subsequently compared to those from computational simulations and erosion of 0.47 mm/year was obtained using the Arabnejad et al. model. The results indicated that the models work well at low velocities and low temperature conditions. To account for temperature effect, a mathematical correlation was developed using data published by DUCOM [3] for Inconel 600 eroded by alumina particles at high velocities. The correlation was applied to both Arabnejad et. al model and the E/CRC model. The prediction results from these modified models were within 20% of this experimental data. Predictions of of erosion by the modified E/CRC model at three different temperatures are made. Similar to the calculation at low temperature, a typical CSP system with 1 kg/s/m of particle flow rate per unit length of the particle curtain and a curtain thickness of 0.0254 m is assumed. The annual thickness loss calculations were run for different particle impact velocities, assuming a uniform particle impact area equal to the cross-sectional area of the curtain (particle-particle interactions and dispersion of particles are not considered in obtaining the results). It is observed that erosion increases exponentially as temperature increases. Furthermore, it is also noted that, erosion changes non-linearly with impact velocity. Currently, experiments are also being conducted to measure erosion of SS316 at 800 ºC with HSP 40/70 particles at low impact velocities. We expect to use the results from high temperature testing to further improve the temperature correlation function. Similar models are also being developed for abrasion erosion resulting from particle sliding along the surfaces as well as attrition from particle to particle and particle to surface interactions. References. [1] Institute, A. P. (1991). API Recommended Practice for Design and Installation of Offshore Production Platform Piping System, API RP 14E. [2] Arabnejad, H., Mansouri, A., Shirazi, S. A., and McLaury, B. S. (2015a). Development of mechanistic erosion equation for solid particles. Wear, 332–333, 1044–1050. http://doi.org/10.1016/j.wear.2015.01.031. [3] https://ducom.com/high-temperature-erosion-evaluating-sample-wear/

14 SOLAR ENERGY↗

Uncertainty in Annual Energy Resulting from Uncertain Irradiance Measurements

We report an analysis quantifying the contribution to uncertainty in annual energy projections from uncertainty in ground-measured irradiance. Uncertainty in measured irradiance is quantified for eight instruments by the difference from a well maintained, secondary standard pyranometer which is regarded as truthful. We construct a statistical model of irradiance uncertainty and apply the model to generate a sample of 100 annual time series of irradiance for each instrument. The sample is propagated through a common performance model for a reference photovoltaic system to quantify variation in annual energy. Although the measured irradiance varies from the reference by a few percent (standard deviation of 1-2%) the uncertainty in annual energy is on the order of a fraction of one percent. We propose a model for a factor that represents uncertainty in modeled annual energy that arises from uncertainty in ground-measured irradiance.

14 SOLAR ENERGY↗

An Observational Study on Cloud Spectral Width in North China

Cloud droplet size distribution (CDSD) is a critical characteristic for a number of processes related to clouds, considering that cloud droplets are formed in different sizes above the cloud-base. This paper analyzes the in-situ aircraft measurements of CDSDs and aerosol concentration ( N a ) performed in stratiform clouds in Hebei, China, in 2015 to reveal the characteristics of cloud spectral width, commonly known as relative dispersion ( ε , ratio of standard deviation (σ) to mean radius (r) of the CDSD). A new algorithm is developed to calculate the contributions of droplets of different sizes to ε . It is found that small droplets with the size range of 1 to 5.5 μm and medium droplets with the size range of 5.5 to 10 μm are the major contributors to ε, and the medium droplets generally dominate the change of ε. The variation of ε with N a can be well explained by comparing the normalized changes of σ and r ( k σ /σ and k r /r ), rather than k σ and k r only ( k σ is Δσ/Δ N a and k r is Δr/Δ N a ). From the perspective of external factors affecting ε change, the effects of N a and condensation are examined. As a result, it is found that ε increases initially and decreases afterward as N a increases, and “condensational broadening” occurs up to 1 km above cloud-base, potentially providing observational evidence for recent numerical simulations in the literature.

54 ENVIRONMENTAL SCIENCES↗

A new method for inferring city emissions and lifetimes of nitrogen oxides from high-resolution nitrogen dioxide observations: a model study

We present a new method to infer emissions and lifetimes of nitrogen oxides (NO x ) based on tropospheric nitrogen dioxide (NO 2 ) observations together with reanalysis wind fields for cities located in polluted backgrounds. Since the accuracy of the method is difficult to assess due to lack of “true values” that can be used as a benchmark, we apply the method to synthetic NO 2 observations derived from the NASA-Unified Weather Research and Forecasting (NU-WRF) model at a high horizontal spatial resolution of 4 km × 4 km for cities over the continental United States. We compare the inferred emissions and lifetimes with the values given by the NU-WRF model to evaluate the method. The method is applicable to 26 US cities. The derived results are generally in good agreement with the values given by the model, with the relative differences of 2 % ± 17 % (mean ± standard deviation) and 15 % ± 25 % for lifetimes and emissions, respectively. Our investigation suggests that the use of wind data prior to the satellite overpass time improves the performance of the method. The correlation coefficients between inferred and NU-WRF lifetimes increase from 0.56 to 0.79 and for emissions increase from 0.88 to 0.96 when comparing results based on wind fields sampled simultaneously with satellite observations and averaged over 9 h data prior to satellite observations, respectively. We estimate that uncertainties in NO x lifetime and emissions arising from the method are approximately 15 % and 20 %, respectively, for typical (US) cities. The total uncertainties reach up to 43% (lifetimes) and 45% (emissions) by considering the additional uncertainties associated with satellite NO 2 observations and wind data. We expect this new method to be applicable to NO 2 observations from the TROPOspheric Monitoring Instrument (TROPOMI) and geostationary satellites, such as Geostationary Environment Monitoring Spectrometer (GEMS) or the Tropospheric Emissions: Monitoring Pollution (TEMPO) instrument, to estimate urban NO x emissions and lifetimes globally.

54 ENVIRONMENTAL SCIENCES↗

A second order yield-temperature relation for accurate inference of burn-averaged quantities in multi-species plasmas

Measured yields and ion temperatures inferred from the fusion product energy spectra can be used as metrics for the performance of an ICF implosion. This can be to infer species separation, thermal decoupling, flows or other effects that can cause the inferred ion temperatures to deviate from the true underlying thermal temperature and the yield ratio to deviate from the expected value. Direct inference of the impact of these effects on observed temperatures and yields can be difficult to uncover due to underlying dependence on the shape and time evolution of the temperature and density proles of the fusing plasma. Due to differences in the temperature dependence of the reactivities, different fusion products are emitted from different regions and times within the implosion. In order to properly account for this, a second order analytic expression relating the apparent temperatures and yield ratios is developed. This expression can be coupled to models of yield and/or temperature altering effects to infer their burn-averaged impact on an implosion. The second order expression shows significant improvement over lower order expressions in synthetic data studies. Demonstrations of its applications to synthetic data coupled with models of ion thermal decoupling and radial flows are presented. In the case of thermal decoupling both first and second order expressions show reasonable levels of accuracy. To consistently infer the amplitude of radial flow with <10% error the second order equation is required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental validation of 3D reconstructed pin-power distributions in full-scale BWR fuel assemblies with partial length rods

Total fission rate measurements have been performed on full-size BWR fuel assemblies of type SVEA-96 Optima2 in the framework of Phase III of the LWR-PROTEUS experimental program at the Paul Scherrer Inst.. This paper presents comparisons of calculated, nodal reconstructed, pin-wise total-fission rate distributions with experimental results. Radial comparisons have been performed for the three sections of the assembly (96, 92 and 84 fuel pins), while three-dimensional effects have been investigated at pellet-level for the two transition regions, i.e. the tips of the short (1/3) and long (2/3) partial length rods. The test zone has been modeled using two different code systems: HELIOS/PRESTO-2 and CASMO-5/SIMULATE-5. The first is presently used for core monitoring and design at the Leibstadt Nuclear Power Plant (KKL). The second represents the most recent generation of the widely applied CASMO/SIMULATE system. For representing the PROTEUS test-zone boundaries, Partial Current Ratios (PCRs) - derived from a 3D MCNPX model of the entire reactor - have been applied to the PRESTO-2 and SIMULATE-5 models in the form of 2- and 5-group diagonal albedo matrices, respectively. The MCNPX results have also served as a reference, high-order transport solution in the calculation/experiment comparisons. It is shown that the performance of the nodal methodologies in predicting the global distribution of the total-fission rate is very satisfactory. Considering the various radial comparisons, the standard deviations of the calculated/experimental (C/E) distributions do not exceed 1.9% for any of the three methodologies - PRESTO-2, SIMULATE-5 and MCNPX. For the three-dimensional comparisons at pellet-level, the corresponding standard deviations are 2.7%, 2.0% and 2.1%, respectively. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spatial resolution limits for synchrotron-based infrared spectromicroscopy

Detailed spatial resolution tests were performed on beamline 1.4.4 at the Advanced Light Source synchrotron facility in Berkeley, CA. The high-brightness synchrotron source is coupled at this beamline to a Thermo-Electron Continumum XL infrared microscope. Two types of resolution tests in both the mid-IR (using a KBr beamsplitter and an MCT-A* detector) and in the near-IR (using a CaF2 beamsplitter and an InGaAS detector) were performed and compared to a simple diffraction-limited spot size model. At the shorter wavelengths in the near-IR the experimental results begin to deviate from only diffraction-limited. The entire data set is fit using a combined diffraction-limit and demagnified electron beam source size model. This description experimentally verifies how the physical electron beam size of the synchrotron source demagnified to the sample stage on the endstation begins to dominate the focussed spot size and therefore spatial resolution at higher energies. We discuss how different facilities, beamlines, and microscopes will affect the achievable spatial resolution.

43 PARTICLE ACCELERATORS↗

Characterizing the Response of Commercial and Industrial Facilities to Dynamic Pricing Signals from the Utility

We describe a method to generate statistical models of electricity demand from Commercial and Industrial (C&I) facilities including their response to dynamic pricing signals. Models are built with historical electricity demand data. A facility model is the sum of a baseline demand model and a residual demand model; the latter quantifies deviations from the baseline model due to dynamic pricing signals from the utility. Three regression-based baseline computation methods were developed and analyzed. All methods performed similarly. To understand the diversity of facility responses to dynamic pricing signals, we have characterized the response of 44 C&I facilities participating in a Demand Response (DR) program using dynamic pricing in California (Pacific Gas and Electric's Critical Peak Pricing Program). In most cases, facilities shed load during DR events but there is significant heterogeneity in facility responses. Modeling facility response to dynamic price signals is beneficial to the Independent System Operator for scheduling supply to meet demand, to the utility for improving dynamic pricing programs, and to the customer for minimizing energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface Roughness Effects on Heat Transfer in Additively Manufactured sCO 2 Cycle Heat Exchangers

An experimental study was performed to consider the impact of surface roughness on heat transfer and pressure drop to supercritical carbon dioxide (sCO 2 ) in additively manufactured channels. All tests were performed in the Heat Exchange and Experimental Testing (HEET) rig at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia. Four test articles were considered. The first was a hydrodynamically smooth, drawn tube. The other three were additively manufactured channels with square and rectangular cross sections, which were characterized by sand-grain roughness to hydraulic diameter ratios spanning 0.0029 to 0.0073. Friction factors were determined by measuring the tube mass flow rate and pressure drop. The tube side heat transfer coefficient was measured using the Wilson plot technique. It was found that the friction factor results were 8% greater than the Colebrook correlation. Greater deviation was observed between the heat transfer results and the correlations. The Gnielinski correlation overpredicted the experimental points by nominally 30% and the Norris correlation overpredicting the experimental points by nominally 25%. A thermal performance factor was formed from the friction factor augmentation and Nusselt number augmentation results. These results indicated a 10% improvement in heat duty for a heat exchanger constructed utilizing a tube with ϵ/D_h =0.0073 relative to a heat exchanger utilizing a smooth, conventional tube.

36 MATERIALS SCIENCE↗

Investigation of a {sup 90}Sr/{sup 90}Y source for intra-ocular treatment of wet age-related macular degeneration

Purpose: The purpose of this study is to perform an extensive investigation of an approximately 2.5 mm long {sup 90}Sr/{sup 90}Y source designed for treating wet age-related macular degeneration. Methods: As part of this investigation, a NIST-traceable absorbed dose to water calibration technique was established, and a source deployment verification test was developed. The influence of treatment cannula construction tolerance on the measurements as well as the dose delivered to the patient was investigated using the Monte Carlo code MCNP5. Variation between production cannulae was quantified experimentally using a well-type ionization chamber, and additional measurements along with Monte Carlo calculations of the collimating insert used for source deployment verification were performed to validate the model. Results: Maximum variation in the integrated target dose was seen when the source was shifted laterally within the treatment cannula. For the well chamber measurements, the observed standard deviation in ionization current for a single source placed in different reference cannulae was {+-}0.3%, with a maximum observed range of less than {+-}0.5%. Clinical cannulae in the collimating insert showed an average of 17.8%{+-}0.4% of the reference signal when sources were fully deployed compared to 18.5% predicted by Monte Carlo calculations. This discrepancy has been attributed primarily to construction of the collimator since the collimation gap was observed to be approximately 0.025-0.075 mm smaller than specified. Construction tolerance of the well chamber insert as well as position tolerance of the cannula tip were both investigated, and their influence on the predicted signal was quantified. Additional measurements along with Monte Carlo based calculations of the collimating insert with polyethylene spacers added to the setup were performed to validate the Monte Carlo model. The shimmed Monte Carlo and measured data agree to within 1%, which is a magnitude difference of approximately 0.1% of the reference signal. Conclusions: This investigation confirms that the signal for an acceptably deployed source in the collimating insert is between 17.5% and 21.5% of the reference signal, as calculated using Monte Carlo models. Clinical cannulae for which the source deployment verification measurement falls outside the acceptable range should not be used to treat patients.

07 ISOTOPE AND RADIATION SOURCES↗

Prospective Evaluation of Pretreatment Executive Cognitive Impairment and Depression in Patients Referred for Radiotherapy

Purpose: Cancer patients are at risk of cognitive impairment and depression. We sought to ascertain the prevalence of executive, visuospatial, memory, and general cognitive performance deficits before radiotherapy in a radiation oncology clinic referral population and correlate the neurocognitive measures with the depression symptom burden. Methods and Materials: A total of 122 sequential patients referred for radiotherapy evaluation were administered a test battery composed of the Executive Interview (EXIT25), Executive Clock Drawing Task (CLOX1 and CLOX2), Mini Mental State Examination (MMSE), Memory Impairment Screen (MIS), and Geriatric Depression Scale (GDS). The mean age {+-} standard deviation was 58 {+-} 17 years. Of 122 patients, 24 (20%) had been referred for breast cancer, 21 (17%) for gastrointestinal cancer, 17 (14%) for genitourinary disease, and 8 (7%) for brain lesions; the rest were a variety of tumor sites. The cognitive performance among the tumor cohorts was compared using Bonferroni-corrected analysis of variance and Tukey-Kramer tests. Pearson correlation coefficients were determined between each cognitive instrument and the GDS. Results: Of the 122 patients, 52 (43%) exhibited a detectable executive cognition decrement on one or more test measures. Five percent had poor memory performance (MIS), 18% had poor visuospatial performance (CLOX2), and 13% had poor global cognition (MMSE). Patients with brain tumors performed substantially worse on the EXIT25. No between-group differences were found for CLOX1, CLOX2, MIS, or GDS performance. The EXIT25 scores correlated significantly with the GDS scores (r = 0.26, p = 0.005). Conclusions: The results of this study have shown that patients referred for radiotherapy exhibit cognitive impairment profiles comparable to those observed in acutely ill medical inpatients. Executive control impairment appears more prevalent than global cognitive deficits, visuospatial impairment, or depression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the HAE activity in the TJ-II stellarator using a Landau closure model

The aim of this study is to analyze the stability of helical Alfvén eigenmodes (HAEs) in TJ-II discharges and the stabilizing effect of the energetic particles generated by the neutral beam injector (NBI) on pressure gradient-driven modes (PGDMs). HAE and PGDM stability is studied using the linear version of the gyro-fluid code FAR3d and the continuous structure by the STELLGAP code. First, Alfvén eigenmode (AE) and PGDM activity observed in the experiments is reproduced by the simulations, identifying unstable m/n = 4/7 − 2/3 and 7/12 − 5/8 HAEs triggered around ρ = 0.66 showing a frequency of 209 and 204 kHz, respectively, as well as 5/3 PGDM. Next, a parametric study is performed with respect to the thermal ion density and iota profile in the middle-outer plasma region to verify the robustness of the simulation results with respect to the uncertainty of experimental profiles. The analysis confirms that experimental uncertainty does not cause large deviations in the simulation results, showing the destabilization of the same HAEs for all the configurations tested. The simulations also indicate the decay of the 5/3 PGDM growth rate as the energetic particle (EP) population in the plasma increases, consistent with the experiment. Stability analysis of the n = 3, 7, 11, n = 5, 9, 13, n = 6, 10, 14, and n = 8, 12 helical families is performed with respect to the NBI operational regime for different EP energies, β as well as deposition profiles. The most unstable configuration is the radially localized on-axis NBI operation (stiff EP density profile gradients nearby the magnetic axis). Using the simulation model that reproduces the observed Alfvén activity, we extend the study to analyze NBI performance within a theoretical framework. It shows that increasing NBI voltage (which raises EP energy) leads to a degradation in NBI performance for a given power (related to EP β and their density). To achieve better NBI operation, higher voltage must be balanced with lower injection power, ensuring stable AEs while keeping the same EP β.

Plasma confinement↗

Superselective Particle Embolization Enhances Efficacy of Radiofrequency Ablation: Effects of Particle Size and Sequence of Action

Purpose. To evaluate the effects of particle size and course of action of superselective bland transcatheter arterial embolization (TAE) on the efficacy of radiofrequency ablation (RFA). Methods. Twenty pigs were divided into five groups: group 1a, 40-{mu}m bland TAE before RFA; group 1b, 40-{mu}m bland TAE after RFA; group 2a, 250-{mu}m bland TAE before RFA; group 2b, 250-{mu}m bland TAE after RFA and group 3, RFA alone. A total of 40 treatments were performed with a combined CT and angiography system. The sizes of the treated zones were measured from contrast-enhanced CTs on days 1 and 28. Animals were humanely killed, and the treated zones were examined pathologically. Results. There were no complications during procedures and follow-up. The short-axis diameter of the ablation zone in group 1a (mean {+-} standard deviation, 3.19 {+-} 0.39 cm) was significantly larger than in group 1b (2.44 {+-} 0.52 cm; P = 0.021), group 2a (2.51 {+-} 0.32 cm; P = 0.048), group 2b (2.19 {+-} 0.44 cm; P = 0.02), and group 3 (1.91 {+-} 0.55 cm; P < 0.001). The greatest volume of ablation was achieved by performing embolization with 40-{mu}m particles before RFA (group 1a; 20.97 {+-} 9.65 cm{sup 3}). At histology, 40-{mu}m microspheres were observed to occlude smaller and more distal arteries than 250-{mu}m microspheres. Conclusion. Bland TAE is more effective before RFA than postablation embolization. The use of very small 40-{mu}m microspheres enhances the efficacy of RFA more than the use of larger particles.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iterative image-domain decomposition for dual-energy CT

Purpose: Dual energy CT (DECT) imaging plays an important role in advanced imaging applications due to its capability of material decomposition. Direct decomposition via matrix inversion suffers from significant degradation of image signal-to-noise ratios, which reduces clinical values of DECT. Existing denoising algorithms achieve suboptimal performance since they suppress image noise either before or after the decomposition and do not fully explore the noise statistical properties of the decomposition process. In this work, the authors propose an iterative image-domain decomposition method for noise suppression in DECT, using the full variance-covariance matrix of the decomposed images. Methods: The proposed algorithm is formulated in the form of least-square estimation with smoothness regularization. Based on the design principles of a best linear unbiased estimator, the authors include the inverse of the estimated variance-covariance matrix of the decomposed images as the penalty weight in the least-square term. The regularization term enforces the image smoothness by calculating the square sum of neighboring pixel value differences. To retain the boundary sharpness of the decomposed images, the authors detect the edges in the CT images before decomposition. These edge pixels have small weights in the calculation of the regularization term. Distinct from the existing denoising algorithms applied on the images before or after decomposition, the method has an iterative process for noise suppression, with decomposition performed in each iteration. The authors implement the proposed algorithm using a standard conjugate gradient algorithm. The method performance is evaluated using an evaluation phantom (Catphan©600) and an anthropomorphic head phantom. The results are compared with those generated using direct matrix inversion with no noise suppression, a denoising method applied on the decomposed images, and an existing algorithm with similar formulation as the proposed method but with an edge-preserving regularization term. Results: On the Catphan phantom, the method maintains the same spatial resolution on the decomposed images as that of the CT images before decomposition (8 pairs/cm) while significantly reducing their noise standard deviation. Compared to that obtained by the direct matrix inversion, the noise standard deviation in the images decomposed by the proposed algorithm is reduced by over 98%. Without considering the noise correlation properties in the formulation, the denoising scheme degrades the spatial resolution to 6 pairs/cm for the same level of noise suppression. Compared to the edge-preserving algorithm, the method achieves better low-contrast detectability. A quantitative study is performed on the contrast-rod slice of Catphan phantom. The proposed method achieves lower electron density measurement error as compared to that by the direct matrix inversion, and significantly reduces the error variation by over 97%. On the head phantom, the method reduces the noise standard deviation of decomposed images by over 97% without blurring the sinus structures. Conclusions: The authors propose an iterative image-domain decomposition method for DECT. The method combines noise suppression and material decomposition into an iterative process and achieves both goals simultaneously. By exploring the full variance-covariance properties of the decomposed images and utilizing the edge predetection, the proposed algorithm shows superior performance on noise suppression with high image spatial resolution and low-contrast detectability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗