Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Epid Dosimetry

Electronic portal imaging devices (EPIDs) were introduced originally for patient position verification. The idea of using EPIDs for dosimetry was realised in the 1980s. Little was published on the topic until the mid 1990's, when the interest in EPIDs for dosimetry increased rapidly and continues to grow. The increasing research on EPID dosimetry coincided with the introduction of intensity modulated radiation therapy (IMRT). EPIDs are well suited to IMRT dosimetry because they are high resolution, two-dimensional (2D) digital detectors. They are also pre-existing on almost all modern linear accelerators. They generally show a linear response to increasing dose. Different types of EPIDs have been clinically implemented, and these have been described in several review papers. The current generation of commercially available EPIDs are indirect detection active matrix flat panel imagers, also known as amorphous silicon (a-Si) EPIDs. Disadvantages of a-Si EPIDs for dosimetry include non-water equivalent construction materials, and the energy sensitivity and optical scatter of the phosphor scintillators used to create optical signal from the megavoltage beam. This report discusses current knowledge regarding a-Si EPIDs for dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rapid additive manufacturing of MR compatible multipinhole collimators with selective laser melting of tungsten powder

Purpose: The construction of complex collimators with a high number of oblique pinholes is very labor intensive, expensive or is sometimes impossible with the current available techniques (drilling, milling or electric discharge machining). All these techniques are subtractive: one starts from solid plates and the material at the position of the pinholes is removed. The authors used a novel technique for collimator construction, called metal additive manufacturing. This process starts with a solid piece of tungsten on which a first layer of tungsten powder is melted. Each subsequent layer is then melted on the previous layer. This melting is done by selective laser melting at the locations where the CAD design file defines solid material. Methods: A complex collimator with 20 loftholes with 500 {mu}m diameter pinhole opening was designed and produced (16 mm thick and 70 Multiplication-Sign 52 mm{sup 2} transverse size). The density was determined, the production accuracy was measured (GOM ATOS II Triple Scan, Nikon AZ100M microscope, Olympus IMT200 microscope). Point source measurements were done by mounting the collimator on a SPECT detector. Because there is increasing interest in dual-modality SPECT-MR imaging, the collimator was also positioned in a 7T MRI scanner (Bruker Pharmascan). A uniform phantom was acquired using T1, T2, and T2* sequences to check for artifacts or distortion of the phantom images due to the collimator presence. Additionally, three tungsten sample pieces (250, 500, and 750 {mu}m thick) were produced. The density, attenuation (140 keV beam), and uniformity (GE eXplore Locus SP micro-CT) of these samples were measured. Results: The density of the collimator was equal to 17.31 {+-} 0.10 g/cm{sup 3} (89.92% of pure tungsten). The production accuracy ranges from -260 to +650 {mu}m. The aperture positions have a mean deviation of 5 {mu}m, the maximum deviation was 174 {mu}m and the minimum deviation was -122 {mu}m. The mean aperture diameter is 464 {+-} 19 {mu}m. The calculated and measured sensitivity and resolution of point sources at different positions in the field-of-view agree well. The measured and expected attenuation of the three sample pieces are in a good agreement. There was no influence of the 7T magnetic field on the collimator (which is paramagnetic) and minimal distortion was noticed on the MR scan of the uniform phantom. Conclusions: Additive manufacturing is a very promising technique for the production of complex multipinhole collimators and may also be used for producing other complex collimators. The cost of this technique is only related to the amount of powder needed and the time it takes to have the collimator built. The timeframe from design to collimator production is significantly reduced.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Origin and characterization of single-electron events in Skipper-CCDs for light dark matter searches

This manuscript summarizes the work carried out within the SENSEI (Sub-Electron-Noise Skipper-CCD Experimental Instrument) collaboration, an effort focused on the search for light dark matter using Skipper-CCDs. Firstly, it presents the data acquisition and processing protocol developed to establish a selection criteria for events compatible with the dark matter signal. This protocol also enabled the structure and tools used for the study and characterization of phenomena that impact the quality of measurements made in the search for dark matter (measurement of the Fano factor, determination of the Compton background, and characterization of the high-energy surface background), which were carried out during this work. Secondly, it discusses the comprehensive study conducted on the origin of single-electron events in Skipper-CCDs, which allowed for the selection of detector operating parameters and improved the detection sensitivity in the search for dark matter. It is highlighted the characterization of the spatial correlation between single-electron events and high-energy events, among other developed event selection criteria, and the optimization of the output device to reduce sources of luminescence during its operation. As a result of this study, the lowest levels of dark current and spurious charge ever measured in a CCD are reported. Finally, the latest published results from SENSEI are presented. The obtained limits for the scattering of a light mediator are the best reported to date across the entire investigated mass range, while for the heavy mediator, they are the best for masses below 10 MeV. In terms of dark matter absorption, the most restringent limits below 10 eV are reported. These results, achieved with only a very small fraction of the total projected exposure for SENSEI, position Skipper-CCDs as leaders in the search for light dark matter worldwide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waste Characterization Methods Based on Gamma-ray Imaging Spectrometers - 19454

Characterization of LLW, ILW, U, NORM and TENORM is critical to the nuclear industry's bottom line. Accurate measurements enable the disposal of waste at the lowest possible cost. In the past the most accurate technology available involved using HPGe detectors and extensive system modeling to estimate the total source term given what the user knows about the geometry of the source and any shielding between the source and the detectors. Now there are a variety of imaging detectors that are available commercially, including CZT and HPGe detectors that achieve energy resolution ≤1% FWHM at 662 keV. These devices couple the traditional high resolution spectroscopic analysis with next generation gamma-ray imaging information to more accurately characterize the radiation source term. Uncertainties in the source location will result in significant error in the characterization of an object's radioactivity. It is helpful if the object can be spun, such as a barrel, so that any asymmetry in the source distribution is averaged out from the detector's point of view. Even in the case of a spinning barrel it is important to determine if the radiation is concentrated near the center of the barrel or distributed near the edge. The closer one measures to a barrel, which usually dictates the time required to acquire data, the more these spatial variations in the source distribution will affect the calculated activity of each isotope. This paper will focus on showing the use of CZT imaging spectrometers to characterize complicated radiation source terms. The radiation images are used to determine where the source term should be defined in a radiation transport model that calculates the expected number of photopeak counts for each isotope detected. This is used to calculate the activity of the source. The transport model is used to determine the attenuation of the radiation source term through distance and shielding material, but the detection efficiency is based solely on radiation measurement data. These measurements are taken with a robotic source positioning device that allows for detailed directional efficiency calibration. It is a fully automated system where a detector is loaded into the device and all of the efficiency curves are captured as a function of direction by creating new measurements for each location the robot positions the source. These measurements are tagged with the true source location and the efficiency curve is calculated for each measurement. This is used to create a response function matrix as a function of energy and incident direction which is used to convert the direction dependent flux on the detector head determined from the simulation model to the expected number of counts per unit activity of each isotope of interest. The results of these source term reconstructions in both the spatial and spectral domain will be shown. The impact of improper specification of the source term will be shown for a few standard waste characterization scenarios to demonstrate the importance of proper source location determination. Finally, the underlying calibration method and some sample efficiency curves as a function of direction will be shown to demonstrate the importance of calibrating out directional response functions in imaging devices (which often have a strong forward sensitivity bias). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Process for the Development of a New Truck Monitoring System - 13306

Canberra Industries, Inc. has designed a new truck monitoring system for a facility in Japan. The customer desires to separately quantify the Cs-137 and Cs-134 content of truck cargo entering and leaving a Waste Consolidation Area. The content of the trucks will be some combination of sand, soil, and vegetation with densities ranging from 0.3 g/cc - 1.6 g/cc. The typical weight of the trucks will be approximately 10 tons, but can vary between 4 and 20 tons. The system must be sensitive enough to detect 100 Bq/kg in 10 seconds (with less than 10% relative standard deviation) but still have enough dynamic range to measure 1,000,000 Bq/kg material. The system will be operated in an outdoor environment. Starting from these requirements, Canberra explored all aspects of the counting system in order to provide the customer with the optimized solution. The desire to separately quantify Cs-137 and Cs-134 favors the use of a spectroscopic system as a solution. Using the In Situ Object Counting System (ISOCS) mathematical efficiency calculation tool, we explored various detector types, number, and physical arrangement for maximum performance. Given the choice of detector, the ISOCS software was used to investigate which geometric parameters (fill height, material density, etc.) caused the most fluctuations in the efficiency results. Furthermore, these variations were used to obtain quantitative estimates of the uncertainties associated with the possible physical variations in the truck size, detector positioning, and material composition, density, and fill height. Various shielding options were also explored to ensure that any measured Cs content would be from the truck and not from the surrounding area. The details of the various calculations along with the final design are given. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fuel-rich oxidation of gasoline surrogate components in an atmospheric flow reactor

Fuel-rich oxidation of three typical gasoline surrogate components, toluene, isooctane, and n-heptane, was investigated in an atmospheric-pressure flow reactor at mean gas temperatures from 1050 to 1350 K, equivalence ratio of 9.0, and residence times of 0.45 and 1.2 s. Not only polycyclic aromatic hydrocarbons (PAHs) up to 3 ring structure but also small intermediate products from C 1 to C 5 were quantified by a gas chromatograph mass spectrometry coupled with photon ionization and gas chromatograph with flame ionization detector, respectively. The kinetic model recently developed by Lawrence Livermore National Laboratory was revised to reflect the results of many recent investigations. Basically, the updated model could satisfactorily reproduce the experimental mole fractions of many species. The experimental and simulated results showed that PAH mole fractions produced were in the order of toluene, isooctane, and n-heptane. The kinetic analysis using the model was carried out to explore PAH formation pathways, especially focusing on naphthalene, acenaphthylene, and phenanthrene. Through rate of production analysis, it was found that the main formation pathways of many PAHs were affected by the fuels. Although resonantly stabilized radicals, such as benzyl and fulvenallenyl radicals, played a crucial role in the formation pathways of many PAHs in every fuel, they were produced through hydrogen elimination of toluene in toluene fuel, while they were formed from small intermediate products in isooctane and n-heptane fuels. Sensitivity analysis revealed the difference and similarity of the reactions with large positive coefficients according to the fuels studied here. In conclusion, the molecular growth reactions of aromatic species were influential in PAH production in every fuel, whereas the ring formation reactions from small species and the reactions involving toluene had large positive sensitivity coefficients in isooctane/n-heptane and toluene fuels, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

THE MODULATION OF GALACTIC COSMIC-RAY ELECTRONS IN THE HELIOSHEATH

Voyager 1 has observed strong increases in the intensities of 2-160 MeV electrons since crossing the termination shock of the heliosphere in 2004 December. Before this time these intensities were submerged below the detector background, except for occasional transient events. These increases are large compared to the concurrent increases of positive ions such as H, He, and O. A significant part is probably due to temporal effects as the heliosphere was recovering to solar minimum conditions from 2005 to early 2010. The intensity observed by Voyager 2 since its crossing of the shock in 2007 September is 5-10 times lower than that observed by Voyager 1, which is so low that the electron intensity may still be below the background produced by high-energy protons in the detector. This points to a large north-south asymmetry in the properties of the heliosheath. It is shown that the observations suggest that these electrons are not freshly accelerated on the termination shock, but rather that they are of galactic origin-while they may be re-accelerated by that shock. In this paper, these intensities are modeled with numerical solutions of the cosmic-ray transport equation. It is shown that because they are relativistic, the electrons are much more sensitive to the form of the diffusion coefficient at low rigidities than ions, and that this can explain the asymmetry.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of GRETINA position resolution to hole mobility

The sensitivity of the position resolution of the gamma-ray tracking array GRETINA to the hole charge-carrier mobility parameter is investigated. The χ 2 results from a fit of averaged signal (“superpulse”) data exhibit a shallow minimum for hole mobilities 15% lower than the currently adopted values. Calibration data on position resolution is analyzed, together with simulations that isolate the hole mobility dependence of signal decomposition from other effects such as electronics cross-talk. Our results effectively exclude hole mobility as a dominant parameter for improving the position resolution for reconstruction of gamma-ray interaction points in GRETINA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NSLS-II Storage Ring Injection Using a Nonlinear Injection Kicker

The NSLS-II has been operating successfully with top off injection since September 2015. Measurements of the stored beam show a transient of 200 μm in the long straight sections during top off injections. This transient is not desirable for some users, particularly those who specialized in imaging or are otherwise sensitive to beam motion. Users are provided with a signal with which they can gate their detectors, but it is desirable to reduce or eliminate this motion all together. Studies have been performed to reduce the transients, and it is clear that the power supplies require more tunability in the pulse shape in order to reduce the transient across the entire bunch train. Other light sources have explored the possibility of using pulsed quadrupoles and sextupoles as the injection magnet. The stored beam receives no kick as the on-axis fields in these magnets is zero, but the injected beam would see a kick as it is off-center. One drawback of the pulsed quadrupole is that the stored beam experiences a size oscillation. Another issue with a nonlinear kicker is the gradient seen by the injected beam. The transport line needs to be tuned for this gradient, and depending on the strength of the nonlinearity, this gradient may change greatly with injected beam position. Therefore, other facilities have explored other magnet configurations that are nonlinear but have a gradient with less positional dependence. The prospect of using a sextupole kicker was investigated during the design phase of the NSLS-II. It was decided that the idea would not be pursued for several reasons. In particular, the design that was studied the most in depth was not compatible with the standard four bump injection design and the tolerances required were deemed too tight at the time. Other ideas were discussed as well and ultimately none were accepted into the design. In this report we discuss the possibility of placing a nonlinear kicker in the first straight section after the injection straight instead of using the injection bumps. The design of the kicker is based on a design that has been used successfully at BESSY and MAX IV. Our conceptual kicker design is compatible with the existing ring optics and power supply requirements. We show that the transport line is capable of being matched to the required optics. The design does not have restrictive tolerances and is a viable option for a facility upgrade.

36 MATERIALS SCIENCE↗

Dithering Strategies and Point-Source Photometry

The accuracy in the photometry of a point source depends on the point-spread function (PSF), detector pixelization, and observing strategy. The PSF and pixel response describe the spatial blurring of the source, the pixel scale describes the spatial sampling of a single exposure, and the observing strategy determines the set of dithered exposures with pointing offsets from which the source flux is inferred. In a wide-field imaging survey, sources of interest are randomly distributed within the field of view and hence are centered randomly within a pixel. A given hardware configuration and observing strategy therefore have a distribution of photometric uncertainty for sources of fixed flux that fall in the field. In this article we explore the ensemble behavior of photometric and position accuracies for different PSFs, pixel scales, and dithering patterns. We find that the average uncertainty in the flux determination depends slightly on dither strategy, whereas the position determination can be strongly dependent on the dithering. For cases with pixels much larger than the PSF, the uncertainty distributions can be non-Gaussian, with rms values that are particularly sensitive to the dither strategy. We also find that for these configurations with large pixels, pointings dithered by a fractional pixel amount do not always give minimal average uncertainties; this is in contrast to image reconstruction for which fractional dithers are optimal. When fractional pixel dithering is favored, a pointing accuracy of better than {approx}0.15 {approx}0.15 pixel width is required to maintain half the advantage over random dithers.

79 ASTRONOMY AND ASTROPHYSICS↗

Geo- and reactor antineutrino sensitivity at THEIA

We present the sensitivity of the THEIA experiment to low-energy geo- and reactor antineutrinos. For this study, we consider one of the possible proposed designs, a 17.8-ktonne fiducial volume THEIA-25 detector filled with water-based liquid scintillator placed at Sanford Underground Research Facility (SURF). We demonstrate THEIA’s sensitivity to measure the geo- and reactor antineutrinos via inverse-beta decay interactions after one year of data taking with $11.9 × 10^{32}$ free target protons. Considering all uncertainties on input throughout the whole analysis chain, the expected number of geo- and reactor antineutrinos is $220^{+30}_{–24}$ (stats+syst) and $168^{+26}_{–24}$ (stat+sys), respectively, after one year of data taking. The corresponding expected fit precision of a sole experiment is evaluated at 8.7% and 10.1%, respectively. We also demonstrate the sensitivity towards fitting individual Th and U contributions, with best fit values of $N_{\text{Th}} = 40^{+26}_{–22}$ (stat+sys) and $N_\text{U}=180^{+30}_{–24}$ (stat+sys). Finally, from the fit results of individual Th and U contributions, we evaluate the mantle signal to be $S_{\text{mantle}} = 9.3±[5.2,5.4]$ NIU (stat+sys). This was obtained assuming a full-range positive correlation $(ρ_c ϵ[0,1])$ between Th and U, and the projected uncertainties on the crust contributions of 8.3% (Th) and 7.0% (U).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A fully 3D approach for metal artifact reduction in computed tomography

Purpose: In computed tomography imaging metal objects in the region of interest introduce inconsistencies during data acquisition. Reconstructing these data leads to an image in spatial domain including star-shaped or stripe-like artifacts. In order to enhance the quality of the resulting image the influence of the metal objects can be reduced. Here, a metal artifact reduction (MAR) approach is proposed that is based on a recomputation of the inconsistent projection data using a fully three-dimensional Fourier-based interpolation. The success of the projection space restoration depends sensitively on a sensible continuation of neighboring structures into the recomputed area. Fortunately, structural information of the entire data is inherently included in the Fourier space of the data. This can be used for a reasonable recomputation of the inconsistent projection data. Methods: The key step of the proposed MAR strategy is the recomputation of the inconsistent projection data based on an interpolation using nonequispaced fast Fourier transforms (NFFT). The NFFT interpolation can be applied in arbitrary dimension. The approach overcomes the problem of adequate neighborhood definitions on irregular grids, since this is inherently given through the usage of higher dimensional Fourier transforms. Here, applications up to the third interpolation dimension are presented and validated. Furthermore, prior knowledge may be included by an appropriate damping of the transform during the interpolation step. This MAR method is applicable on each angular view of a detector row, on two-dimensional projection data as well as on three-dimensional projection data, e.g., a set of sequential acquisitions at different spatial positions, projection data of a spiral acquisition, or cone-beam projection data. Results: Results of the novel MAR scheme based on one-, two-, and three-dimensional NFFT interpolations are presented. All results are compared in projection data space and spatial domain with the well-known one-dimensional linear interpolation strategy. Conclusions: In conclusion, it is recommended to include as much spatial information into the recomputation step as possible. This is realized by increasing the dimension of the NFFT. The resulting image quality can be enhanced considerably.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 07: Simultaneous reconstruction of both true and scattered coincidences using a Generalized Scatter reconstruction algorithm in PET

Introduction: Scattered coincidences in PET are generally taken as noise, which reduces image contrast and compromises quantification. We have developed a method, with promising results, to reconstruct activity distribution from scattered PET events instead of simply correcting for them. The implementation of this method on clinical PET scanners is however limited by the currently available detector energy resolution. With low energy resolution we lose the ability to distinguish scattered coincidences from true events based on the measured photon energy. In addition the two circular arcs used to confine the source position for a scattered event cannot be accurately defined. Method: This paper presents a modification to this approach which accounts for limited energy resolution. A measured event is split into a true and a scattered component each with different probabilities based on the position of the pair of photon energies in the energy spectrum. For the scattered component, we model the photon energy with a Gaussian distribution and the upper and lower energy limits can be estimated and used to define inner and outer circular arcs to confine the source position. The true and scattered components for each measured event were reconstructed using our Generalized Scatter reconstruction algorithm. Results and Conclusion: The results show that the contrast and noise properties were improved by 6–9% and 2–4% respectively. This demonstrates that the performance of the algorithm is less sensitive to the energy resolution and that incorporating scattered photons into reconstruction brings more benefits than simply rejecting them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The impact of MLC transmitted radiation on EPID dosimetry for dynamic MLC beams

The purpose of this study was to experimentally quantify the change in response of an amorphous silicon (a-Si) electronic portal imaging device (EPID) to dynamic multileaf collimator (dMLC) beams with varying MLC-transmitted dose components and incorporate the response into a commercial treatment planning system (TPS) EPID prediction model. A combination of uniform intensity dMLC beams and static beams were designed to quantify the effect of MLC transmission on EPID response at the central axis of 10x10 cm{sup 2} beams, at off-axis positions using wide dMLC beam profiles, and at different field sizes. The EPID response to MLC transmitted radiation was 0.79{+-}0.02 of the response to open beam radiation at the central axis of a 10x10 cm{sup 2} field. The EPID response to MLC transmitted radiation was further reduced relative to the open beam response with off-axis distance. The EPID response was more sensitive to field size changes for MLC transmitted radiation compared to open beam radiation by a factor of up to 1.17 at large field sizes. The results were used to create EPID response correction factors as a function of the fraction of MLC transmitted radiation, off-axis distance, and field size. Software was developed to apply the correction factors to each pixel in the TPS predicted EPID image. The corrected images agreed more closely with the measured EPID images in areas of intensity modulated fields with a large fraction of MLC transmission and, as a result the accuracy of portal dosimetry with a-Si EPIDs can be improved. Further investigation into the detector response function and the radiation source model are required to achieve improvements in accuracy for the general case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microsecond Time Resolution Optical Photometry using a H.E.S.S. Cherenkov Telescope

We have constructed an optical photometer with microsecond time resolution, which is currently being operated on one of the H.E.S.S. telescopes. H.E.S.S. is an array of four Cherenkov telescopes, each with a 107 m{sup 2} mirror, located in the Khomas highland in Namibia. In its normal mode of operation H.E.S.S. observes Cherenkov light from air showers generated by very high energy gamma-rays in the upper atmosphere. Our detector consists of seven photomultipliers, one in the center to record the lightcurve from the target and six concentric photomultipliers as a veto system to reject disturbing signals e.g. from meteorites or lightning at the horizon. The data acquisition system has been designed to continuously record the signals with zero deadtime. The Crab pulsar has been observed to verify the performance of the instrument and the GPS timing system. Compact galactic targets were observed to search for flares on timescales of a few microseconds to {approx}100 ms. The design and sensitivity of the instrument as well as the data analysis method are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

Establishing a Pure Sample of Side-Piercing Through-Going Cosmic-Ray Muons for LArTPC Calibration in MicroBooNE

Measuring detector properties and performing calibrations of a near-surface Liquid Argon Time Projection Chamber (LArTPC) require large samples of well-reconstructed tracks. Cosmic-ray muon tracks are an ideal calibration source for a surface TPC for these purposes, because they cover the detector volume roughly uniformly and enter the detector volume at a high rate. In order to calibrate the TPC’s position response, the reconstructed track for the 3D trajectory of each cosmic-ray muon must be available. Because of the slow electron drift velocity, reconstructed track information along the drift-coordinate is offset with respect to the true energy deposition location. This offset can be corrected only if the time at which the track enters the detector volume (t 0 ) is also reconstructed. In this note we present a method developed for reconstructing track t 0 for the subset of cosmic-ray tracks which hit either the TPC anode-plane or cathode-plane and are through-going. Over 97% of the t 0 -tagged tracks have their t 0 correctly reconstructed in both simuation in cosmic-ray data while maintaining yield values of 0.9 tracks per 4.8 ms exposure for cathode-piercing tracks and 1.7 tracks per 4.8 ms exposure for anode-piercing tracks in simulation. Coverage maps for an off-beam cosmicray data sample of t 0 -tagged tracks produced with this method show that t 0 -tagged track coverage is as expected given cosmic track geometries in the TPC, acceptance effects, and cut sensitivities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Heavy Neutral Leptons at the MINER$\nu$A detector

Heavy Neutral Leptons (HNL) are particles hypothesised to provide a mass generation mechanism for the active (observed) neutrino species, which are known to have nonzero mass from the definitive observation of neutrino oscillations. HNL are eigenstates of mass of the order $\mathcal{O}(0.1 − 1\,\,\mathrm{GeV}/c^{2})$, which mix into the active flavour eigenstates through the extended leptonic mixing matrix. Apart from neutrino mass, they could provide a natural dark matter candidate and a mechanism for matter-antimatter asymmetry in the early Universe, giving rise to today’s matter-dominated cosmos. Searches for HNL typically attempt to either confirm the existence of HNL through an excess in data that is most compatible with an HNL hypothesis, or by setting limits on the HNL parameter space $\left(M_{N4}, \left|U_{\alpha 4}\right|^{2}\right)$ in the case of statistically insignificant excess. Such searches are intensifying as part of a global research programme at both colliders and accelerator / atmospheric neutrino experiments. One such setting is the MINER$\nu$A experiment, located in the NuMI beamline at Fermilab. MINER$\nu$A has collected a large amount of data over seven years of operation to measure the cross-sections of neutrino-nucleus interactions necessary to drive systematic uncertainties down, in order for neutrino oscillation experiments to achieve sensitivity to CP violation in the neutrino sector. With the high-energy, high-intensity NuMI beam, and with good timing, position, and angular resolution leading to sensitivity to HNL decays, MINER$\nu$A is fertile ground for an HNL search, which is performed in this thesis. Specifically, a novel, experiment-agnostic and general simulation of HNL production and decay is presented and deployed; this simulation has been incorporated in the ubiquitous GENIE neutrino event generator for use with neutrino experiments in the future. The event selection and background characterisation is discussed in detail, including the primary background coming from charged-current coherent and diffractive pion production from neutrino-nucleus interactions, and constraints on the background using control regions from MINER$\nu$A data are derived. Finally, by means of a fake-data study given a background of $\mathcal{O}(500)$ events, the discovery potential and limit-setting capacity of MINER$\nu$A is demonstrated, and ways to improve this capacity are expounded upon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗